J9856A

Hewlett Packard Enterprise J9856A, 2530-48G-2SFP+, J9853A, J9854A, J9855A Datasheet

  • Hello! I am an AI chatbot trained to assist you with the Hewlett Packard Enterprise J9856A Datasheet. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Key features
•Cost-eective,reliable,protectedandfullymanagedL2switches
•8,24,or48GigabitorFastEthernetportswithuptofourGigabitortwo10Gigabituplinkports
•PoE+modelsforvoice,video,andwirelessdeployments
•Accesscontrollists(ACLs),EEE,andIPv4/IPv6hostsupport
•LimitedLifetimeWarranty2.0with3years24x7phonesupport
Product overview
TheHP2530SwitchSeriesconsistsof16fullymanagedL2edgeswitchesthatdelivercost-
eective,reliable,protectedandeasy-to-useconnectivitytobusinessnetworks.Designedfor
entry-leveltomidsizeenterprisenetworks,theseGigabitandFastEthernetswitchesdeliver
fullL2capabilitieswithoptionalPoweroverEthernet(PoE),enhancedaccesssecurity,traic
prioritization,andIPv6hostsupport.
TheHP2530SwitchSeriesoersuplinkexibilitywitheitherfourGigabitortwo10Gigabit
Ethernetuplinksonsome24-and48-portmodels.TheGigabit24-and48-portmodels
haveeithertwosmallform-factorpluggableplus(SFP+)orfoursmallform-factorpluggable
(SFP)slotsforberconnectivity.TheFastEthernet24-and48-portmodelshavetwoSFPs
andtwoRJ-45Gigabituplinks.Thecompactandfan-less8-portswitchesoeradditional
exibilitywithtwodual-personalityportsthatcanbeusedaseitherRJ-45GigabitEthernet
orSFPports.Moreover,theHP2530SwitchSeriesPoE+SwitchesareIEEE802.3af-andIEEE
802.3at-compliantwithupto30Wperport,makingthemsuitableforvoice,video,orwireless
deploymentswithPoE+.
Data sheet
HP 2530 Switch Series
2
Datasheet|HP2530SwitchSeries
Theswitchseriesiseasytouse,deploy,andmanageviatheSNMP,CLI,andWebGUI.Itoers
exiblewall,table,andrackmountingoptions;quietoperationwithfan-lessandvariable-speed
fanmodels;andimprovedpowersavingswithfeaturessuchasIEEE802.3azenergy-eicient
Ethernet.AnditincludesLimitedLifetimeWarranty2.0with3years24x7phonesupportand
includesallsoftwarereleases.
Features and benets
Quality of Service
•Traicprioritization(IEEE802.1p)
Allowsreal-timetraicclassicationwithsupportforeightprioritylevelsmappedtoeither
twoorfourqueues,andusesweighteddecitround-robin(WDRR)orstrictpriority
•Simpliedqualityofservice(QoS)conguration
Port-based
Prioritizestraicbyspecifyingaportandprioritylevel
VLAN-based
PrioritizestraicbyspecifyingaVLANandprioritylevel
•ClassofService(CoS)
SetstheIEEE802.1pprioritytagbasedonIPaddress,IPTypeofService(ToS),Layer3
protocol,TCP/UDPportnumber,sourceport,andDiServ
•Ratelimiting
Establishesper-portingress-enforcedmaximumsforallingressedtraicorforbroadcast,
multicast,orunknowndestinationtraic
•Layer4prioritization
EnablesprioritizationbasedonTCP/UDPportnumbers
•Flowcontrol
Helpsdeliverreliablecommunicationduringfull-duplexoperation
Management
•Choiceofmanagementinterfaces
HTML-basedeasy-to-useWebGUI
AllowscongurationoftheswitchfromanyWebbrowser
RobustCLI
Providesadvancedcongurationanddiagnostics
Simplenetworkmanagementprotocol(SNMPv1/v2c/v3)
Allowstheswitchtobemanagedwithavarietyofthird-partynetworkmanagement
applications
•Virtualstacking
ProvidessingleIPaddressmanagementforupto16switches
•sFlow(RFC3176)
Deliverswire-speedtraicaccountingandmonitoring,conguredbySNMPandCLIwiththree
terminalencryptedreceivers
3
Datasheet|HP2530SwitchSeries
•IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)
Automatesdevicediscoveryprotocolforeasymappingbynetworkmanagementapplications
•Logging
ProvideslocalandremoteloggingofeventsviaSNMP(v2candv3)andsyslog;provideslog
throttlingandloglteringtoreducethenumberoflogeventsgenerated
•Portmirroring
Allowstraictobemirroredonanyportoranetworkanalyzertoassistwithdiagnosticsor
detectingnetworkattacks
•Remotemonitoring(RMON)
Providesadvancedmonitoringandreportingcapabilitiesforstatistics,history,alarms,and
events
•Find,x,andinform
Findsandxescommonnetworkproblemsautomatically,andtheninformstheadministrator
•Friendlyportnames
Allowsassignmentofdescriptivenamestoports
•Dualashimages
Providesindependentprimaryandsecondaryoperatingsystemlesforbackupwhile
upgrading
•Multiplecongurationles
Areeasilystoredwithaashimage
•Front-panelLEDs
LocatorLEDs
AllowsuserstosetthelocatorLEDonaspecicswitchtoturnon,blink,orturno;and
simpliestroubleshootingbymakingiteasytolocateaparticularswitchwithinarackof
similarswitches
Per-portLEDs
Providesanat-a-glanceviewofthestatus,activity,speed,andfull-duplexoperation
PowerandfaultLEDs
Displayissues,ifany
•HPComwareCLI
Comware-compatibleCLI
BridgestheexperienceofHPComwareCLIuserswhoareusingtheHPProVisionsoftware
CLI
DisplayandfundamentalComwareCLIcommands
AreembeddedintheswitchCLIasnativecommands;displayoutputisformattedason
Comware-basedswitches,andfundamentalcommandsprovideaComware-familiarinitial
switchsetup
CongurationComwareCLIcommands
WhenComwarecommandsareentered,CLIhelpselicittoformulatethecorrectProVision
softwareCLIcommand
•NEWDownloadsoftwareviaDHCP
AddstheoptiontospecifythelocationofswitchsoftwareviaDHCP
•NEWTR-069support
Enableszero-touchcongurationforswitches
4
Datasheet|HP2530SwitchSeries
Connectivity
•IPv6
IPv6host
AllowstheswitchtobedeployedandmanagedattheedgeofanIPv6network
Dualstack(IPv4/IPv6)
Supportsconnectivityforbothprotocols;providesatransitionmechanismfromIPv4toIPv6
MLDsnooping
ForwardsIPv6multicasttraictoappropriateinterface;preventsIPv6multicasttraicfrom
oodingthenetwork
IPv6ACL/QoS
SupportsACLandQoSforIPv6networktraiconGigabitand48port10/100models
Security
RAGuard,DHCPv6Protection,DynamicIPv6Lockdown(YAonly)
•IEEE802.3afPoweroverEthernet(PoE)
Providesupto15.4WperporttoIEEE802.3af-compliantPoE-powereddevicessuchasIP
phones,wirelessaccesspoints,andsecuritycameras
•IEEE802.3atPoE+
Providesupto30WperporttoIEEE802.3forPoE/PoE+-powereddevicessuchasvideoIP
phones,IEEE802.11nwirelessaccesspoints,andadvancedpan/tilt/zoomsecuritycameras
(refertotheproductspecicationsforthetotalPoEpoweravailability)
•Auto-MDIX
Adjustsautomaticallyforstraight-throughorcrossovercablesonallports
•Pre-standardPoEsupport
Detectsandprovidespowertopre-standardPoEdevices(refertothelistofsupporteddevices
intheproductFAQs,whichcanbeaccessedathp.com/networking/support)
•SFPslots
ProvidesberconnectivitysuchasGigabit-SX,LX,LH,andBXwithfourSFPslotsonall24-and
48-portGigabitEthernetmodels.FastEthernet24-and48-portmodelshavetwoSFPslots
andtwoRJ-45Gigabituplinks;8-portmodelshavetwodual-personalityportssupporting
eitherSFPorRJ-45Gigabituplinks
•Dual-personality(RJ-45orUSBmicro-B)serialconsoleport
GiveseasyaccesstoswitchCLIwithfront-of-switchlocationandtheexibilityofusingeither
anRJ-45orUSBmicro-Bserialconsoleport
5
Datasheet|HP2530SwitchSeries
Layer 2 switching
•VLANs
Providessupportfor512VLANsand4,094VLANIDs
•Jumbopacketsupport
Supportsupto9,220-byteframesizetoimprovetheperformanceoflargedatatransfers;
8-and24-portFastEthernetmodelsautomaticallysupportupto2,000-byteframeswithno
congurationneeded
•16KMACaddresstable
ProvidesaccesstomanyLayer2devices
•GARPVLANRegistrationProtocol
AllowsautomaticlearninganddynamicassignmentofVLANs
•NEWRapidPer-VLANSpanningTree(RPVST+)
AllowseachVLANtobuildaseparatespanningtreetoimprovelinkbandwidthusage;is
compatiblewithPVST+
Security
•ACLs
AccommodatesIPv4/IPv6portandVLAN-basedACLs(IPv6ACLissupportedonlyonGigabit
Ethernetand48-portmodels.)
•Source-portltering
Allowsonlyspeciedportstocommunicatewitheachother
•RADIUS/TACACS+
Easesswitchmanagementsecurityadministrationbyusingapasswordauthenticationserver
•SecureSocketsLayer(SSL)
EncryptsallHTTPtraic,allowingsecureaccesstothebrowser-basedmanagementGUIinthe
switch
•Portsecurity
AllowsaccessonlytospeciedMACaddresses,whichcanbelearnedorspeciedbythe
administrator
•MACaddresslockout
PreventsparticularconguredMACaddressesfromconnectingtothenetwork
6
Datasheet|HP2530SwitchSeries
•Multipleuserauthenticationmethods
IEEE802.1X
UsesanIEEE802.1XsupplicantontheclientinconjunctionwithaRADIUSserverto
authenticateinaccordancewithindustrystandards
Web-basedauthentication
Providesabrowser-basedenvironment,similartoIEEE802.1X,toauthenticateclientsthat
donotsupporttheIEEE802.1Xsupplicant
MAC-basedauthentication
AuthenticatestheclientwiththeRADIUSserverbasedontheclient’sMACaddress
•Secureshell(SSH)v2
EncryptsalltransmitteddataforsaferemoteCLIaccessoverIPnetworks
•Secureshell
EncryptsalltransmitteddataforsaferemoteCLIaccessoverIPnetworks
•STPBPDUportprotection
BlocksBridgeProtocolDataUnits(BPDUs)onportsthatdonotrequireBPDUs,preventing
forgedBPDUattacks
•STProotguard
Protectstherootbridgefrommaliciousattacksorcongurationmistakes
•Securemanagementaccess
Deliversprotectedencryptionofallaccessmethods(CLI,GUI,orMIB)throughSSHv2and
SNMPv3
•Custombanner
Displayssecuritypolicywhenuserslogintotheswitch
•SecureFTP
Allowssafeletransfertoandfromtheswitch;protectsagainstunwantedledownloadsor
unauthorizedcopyingofaswitchcongurationle
•ProtectedportsCLI
OersintuitiveCLItocongurethesource-portlterfeature,byallowingspeciedportstobe
isolatedfromallotherportsontheswitch;theprotectedportorportscancommunicateonly
withtheuplinkorsharedresources
7
Datasheet|HP2530SwitchSeries
•Authenticationexibility
MultipleIEEE802.1Xusersperport
Providesauthenticationforupto32IEEE802.1Xusersperport;preventsauserfrom
“piggybacking”onanotheruser’sIEEE802.1Xauthentication
ConcurrentIEEE802.1XandWeborMACauthenticationschemesperport
AllowsaswitchporttoacceptanyIEEE802.1XandeitherWeborMACauthentications
•Switchmanagementlogonsecurity
HelpssecureswitchCLIlogonbyoptionallyrequiringeitherRADIUSorTACACS+authentication
•NEWDHCPprotection
BlocksDHCPpacketsfromunauthorizedDHCPservers,preventingdenial-of-serviceattacks
•NEWDynamicARPprotection
BlocksARPbroadcastsfromunauthorizedhosts,preventingeavesdroppingortheftof
networkdata
•NEWDynamicIPlockdown
WorkswithDHCPprotectiontoblocktraicfromunauthorizedhosts,preventingIPsource
addressspoong
Convergence
•IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)
FacilitateseasymappingusingnetworkmanagementapplicationswithLLDPautomated
devicediscoveryprotocol
•LLDP-MED(MediaEndpointDiscovery)
DenesastandardextensionofLLDPthatstoresvaluesforparameterssuchasQoSandVLAN
toautomaticallycongurenetworkdevicessuchasIPphones
•IPmulticast(data-drivenIGMP)
PreventsoodingofIPmulticasttraic
•PoEandPoE+allocations
Supportmultiplemethodsautomatic,IEEE802.3atdynamic,LLDP-MEDnegrain,IEEE
802.3afdeviceclass,oruserspecied—toallocateandmanagePoE/PoE+powerformore
eicientenergyuse
•VoiceVLAN
UsesLLDP-MEDtoautomaticallycongureaVLANforIPphones
•IPmulticast(data-drivenIGMPv3)
PreventsoodingofIPmulticasttraic
•LLDP-CDPcompatibility
ReceivesandrecognizesCDPpacketsfromCisco’sIPphonesforseamlessinteroperation
•NEWLocalMACAuthentication
AssignsattributessuchasVLANandQoSusinglocallyconguredprolethatcanbealistof
MACprexesUniedWiredandWireless
•NEWHTTPredirectfunction
SupportsHPIntelligentManagementCenter(IMC)bringyourowndevice(BYOD)solution
8
Datasheet|HP2530SwitchSeries
Resiliency and high availability
•Porttrunkingandlinkaggregation
Trunking
Supportsuptoeightlinkspertrunktoincreasebandwidthandcreateredundant
connections;andsupportsL2,L3,andL4trunkload-balancingalgorithm(L4trunkload
balancingissupportedonlyonGigabitEthernetand48-portmodels.)
IEEE802.3adLinkAggregationControlProtocol(LACP)
Easescongurationoftrunksthroughautomaticconguration
•IEEE802.1sMultipleSpanningTree
ProvideshighlinkavailabilityinmultipleVLANenvironmentsbyallowingmultiplespanning
trees;provideslegacysupportforIEEE802.1dandIEEE802.1w
•NEWSmartLink
Provideseasy-to-congurelinkredundancyofactiveandstandbylinks
Product architecture
•Energy-eicientdesign
IEEE802.3az
ReducespowerconsumptionduringperiodsoflowdataactivityonGigabitEthernetswitches
Portlow-powermode
Enablestheporttoautomaticallygointolow-powermodetoconserveenergywhennolink
isdetected
Fan-lessandvariable-speedfans
Decreasespowerconsumptioninfan-less(all8-port,2530-24,and2530-48PoE+switches)
aswellasvariable-speedfanswitches
PortLEDs
ConservesenergybyoptionallyturningoportlinkandactivityLEDs
•Switchonachip
Providesahighlyintegrated,high-performanceswitchdesignwithanonblockingarchitecture
9
Datasheet|HP2530SwitchSeries
Flexibility
•Flexiblemounting
Rackmountable
Allowstheswitchtobemountedonastandard19-inchrack,withthehardwareincluded
Wallmountable
Allowstheswitchtobemountedonawall,usingthehardwareincluded
Surfacemountable
Allowstheswitchtobemountedaboveorbelowasurface(suchasadeskortable),using
thehardwareincluded
•Quietoperation
Lowersnoise,makingitsuitablefordeploymentsinacousticallysensitiveenvironmentssuch
asconferenceroomsandoicespaces
•Compactsize
Reducesspacerequirements(refertotheproductspecicationsfortheexactdimensions)
Warranty and support
•LimitedLifetimeWarranty2.0
Advancehardwarereplacementwithnext-business-daydelivery(availableinmostcountries).
Seehp.com/networking/warrantysummaryfordurationdetails
•Electronicandtelephonesupport(forLimitedLifetimeWarranty2.0)
Limited24x7telephonesupportisavailablefromHPfortherst3years;limitedelectronic
andbusinesshourstelephonesupportisavailablefromHPfortheentirewarrantyperiod;
toreachoursupportcenters,refertohp.com/networking/contact-support;fordetailson
thedurationofsupportprovidedwithyourproductpurchase,refertohp.com/networking/
warrantysummary
•Softwarereleases
Tondsoftwareforyourproduct,refertohp.com/networking/support;fordetailsonthe
softwarereleasesavailablewithyourproductpurchase,refertohp.com/networking/
warrantysummary
10
Datasheet|HP2530SwitchSeries
HP 2530 Switch Series
Specications
HP 2530-48G-PoE+ Switch (J9772A) HP 2530-24G-PoE+ Switch (J9773A) HP 2530-8G-PoE+ Switch (J9774A)
I/O ports and slots 48RJ-45autosensing10/100/1000PoE+
ports(IEEE802.3Type10BASE-T,IEEE
802.3uType100BASE-TX,IEEE802.3ab
Type1000BASE-T,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:10BASE-
T/100BASE-TX:halforfull;1000BASE-T:
fullonly
4xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
24RJ-45autosensing10/100/1000PoE+
ports(IEEE802.3Type10BASE-T,IEEE
802.3uType100BASE-TX,IEEE802.3ab
Type1000BASE-T,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:10BASE-
T/100BASE-TX:halforfull;1000BASE-T:
fullonly
4xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
8RJ-45autosensing10/100/1000PoE+
ports(IEEE802.3Type10BASE-T,IEEE
802.3uType100BASE-TX,IEEE802.3ab
Type1000BASE-T,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:10BASE-
T/100BASE-TX:halforfull;1000BASE-T:
fullonly
2dual-personalityports;eachportcan
beusedaseitheranRJ-4510/100/1000
port(IEEE802.3Type10BASE-T;IEEE
802.3uType100BASE-TX;IEEE802.3ab
1000BASE-TGigabitEthernet)orasaSFP
slot(forusewithSFPtransceivers)
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
Physical characteristics
Dimensions
Weight
17.44(w)x13.00(d)x1.75(h)in(44.3x
32.26x4.45cm)(1Uheight)
10.4lb(4.72kg)
17.44(w)x13.00(d)x1.75(h)in(44.3x
33.02x4.45cm)(1Uheight)
8.7lb(3.95kg)
10(w)x6.28(d)x1.75(h)in(25.4x15.95x
4.45cm)(1Uheight)
2.2lb(1kg)
Memory and processor
Processor ARM9E@800MHz,128MBash,256
MBDDR3DIMM;packetbuersize:3MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
Mounting and enclosure MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
Performance
100MbLatency
1000MbLatency
Throughput
Switchingcapacity
MACaddresstablesize
IPv6ReadyCertied
<7.4µs(LIFO64-bytepackets)
<2.3µs(LIFO64-bytepackets)
upto77.3millionpps(64-bytepackets)
104Gb/s
16000entries
IPv6ReadyCertied
<7.4µs(LIFO64-bytepackets)
<2.3µs(LIFO64-bytepackets)
upto41.6millionpps(64-bytepackets)
56Gb/s
16000entries
IPv6ReadyCertied
<7.4µs(LIFO64-bytepackets)
<2.6µs(LIFO64-bytepackets)
upto14.8millionpps(64-bytepackets)
20Gb/s
16000entries
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storage
temperature
Nonoperating/Storagerelative
humidity
Altitude
Acoustic
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),
noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),
noncondensing
upto10,000ft(3km)
Power:43.6dB,Pressure:33.6dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),
noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),
noncondensing
upto10,000ft(3km)
Power:43.9dB,Pressure:39.6dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),
noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),
noncondensing
upto10,000ft(3km)
Power:0dB,Pressure:0dB
11
Datasheet|HP2530SwitchSeries
HP 2530-48G-PoE+ Switch (J9772A) HP 2530-24G-PoE+ Switch (J9773A) HP 2530-8G-PoE+ Switch (J9774A)
Electrical characteristics
Frequency
Maximumheatdissipation
ACvoltage
Current
Maximumpowerrating
Idlepower
PoEpower
50/60Hz
236BTU/hr(248.98kJ/hr),(switchonly:
236BTU/hr;combinedswitch+max.PoE
devices:1624BTU/hr)
100-127/200-240VAC
5.8/2.9A
476W
40.1W
382W
Notes
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
PoEpoweristhetotalpowerbudget
availabletoallPoEports.
50/60Hz
135BTU/hr(142.42kJ/hr),(switchonly:
135BTU/hr;combinedswitch+max.PoE
devices:843BTU/hr)
100-127/200-240VAC
3.2/1.6A
247W
25.2W
195W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
PoEpoweristhetotalpowerbudget
availabletoallPoEports.
50/60Hz
65BTU/hr(68.58kJ/hr),(switchonly:
65BTU/hr;combinedswitch+max.PoE
devices:293BTU/hr)
100-127/200-240VAC
1.4A
86W
13.4W
67W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
PoEpoweristhetotalpowerbudget
availabletoallPoEports.
Safety UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
Emissions FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticeld
Voltagedipsandinterruptions
Harmonics
Flicker
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
Notes IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
Services
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
12
Datasheet|HP2530SwitchSeries
HP 2530 Switch Series (continued)
Specications (continued)
HP 2530-48-PoE+ Switch (J9778A) HP 2530-24-PoE+ Switch (J9779A) HP 2530-8-PoE+ Switch (J9780A)
I/O ports and slots 48RJ-45autosensing10/100PoE+ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:halforfull
2autosensing10/100/1000ports(IEEE
802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
2xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
24RJ-45autosensing10/100PoE+ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:halforfull
2autosensing10/100/1000ports(IEEE
802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
2xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
8RJ-45autosensing10/100PoE+ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:halforfull
2dual-personalityports;eachportcan
beusedaseitheranRJ-4510/100/1000
port(IEEE802.3Type10BASE-T;IEEE
802.3uType100BASE-TX;IEEE802.3ab
1000BASE-TGigabitEthernet)orasaSFP
slot(forusewithSFPtransceivers)ports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
Physical characteristics
Dimensions
Weight
17.4(w)x12.7(d)x1.75(h)in(44.2x32.26x
4.45cm)(1Uheight)
10.1lb(4.58kg)
17.4(w)x12.7(d)x1.75(h)in(44.2x32.26x
4.45cm)(1Uheight)
8.4lb(3.81kg)
10(w)x6.28(d)x1.75(h)in(25.4x15.95x
4.45cm)(1Uheight)
2.0lb(0.91kg)
Memory and processor
Processor ARM9E@800MHz,128MBash,256
MBDDR3DIMM;packetbuersize:3MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
Mounting and enclosure MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
Performance
100MbLatency
1000MbLatency
Throughput
Switchingcapacity
MACaddresstablesize
IPv6ReadyCertied
<6.6µs(LIFO64-bytepackets)
<2.2µs(LIFO64-bytepackets)
upto13millionpps(64-bytepackets)
17.6Gb/s
16000entries
IPv6ReadyCertied
<1.7µs(LIFO64-bytepackets)
<1.1µs(LIFO64-bytepackets)
upto9.5millionpps(64-bytepackets)
12.8Gb/s
16000entries
IPv6ReadyCertied
<1.3µs(LIFO64-bytepackets)
<2.3µs(LIFO64-bytepackets)
upto4.1millionpps(64-bytepackets)
5.6Gb/s
16000entries
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storage
temperature
Nonoperating/Storagerelative
humidity
Altitude
Acoustic
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:37.9dB,Pressure:31.8dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:40.4dB,Pressure:31.7dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:0dB,Pressure:0dB
13
Datasheet|HP2530SwitchSeries
HP 2530-48-PoE+ Switch (J9778A) HP 2530-24-PoE+ Switch (J9779A) HP 2530-8-PoE+ Switch (J9780A)
Electrical characteristics
Frequency
Maximumheatdissipation
ACvoltage
Current
Maximumpowerrating
Idlepower
PoEpower
50/60Hz
170BTU/hr(179.35kJ/hr),(switchonly:
170BTU/hr;combinedswitch+max.PoE
devices:1505BTU/hr)
100-127/200-240VAC
5.2/2.6A
441W
37.5W
382W
Notes
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
PoEpoweristhetotalpowerbudget
availabletoallPoEports.
50/60Hz
99BTU/hr(104.45kJ/hr),(switchonly:
99BTU/hr;combinedswitch+max.PoE
devices:809BTU/hr)
100-127/200-240VAC
2.8/1.4A
237W
21.8W
195W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
PoEpoweristhetotalpowerbudget
availabletoallPoEports.
50/60Hz
29BTU/hr(30.6kJ/hr),(switchonly:29
BTU/hr;combinedswitch+max.PoE
devices:262BTU/hr)
100-127/200-240VAC
1.4A
76.7W
5.8W
67W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
PoEpoweristhetotalpowerbudget
availabletoallPoEports.
Safety UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
Emissions FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticeld
Voltagedipsandinterruptions
Harmonics
Flicker
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
Notes IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
Services
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
14
Datasheet|HP2530SwitchSeries
HP 2530-48G Switch (J9775A) HP 2530-24G Switch (J9776A) HP 2530-8G Switch (J9777A)
I/O ports and slots 48RJ-45autosensing10/100/1000ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
4xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
24RJ-45autosensing10/100/1000ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
4xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
8RJ-45autosensing10/100/1000ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);MediaType:Auto-MDIX;
Duplex:10BASE-T/100BASE-TX:halfor
full;1000BASE-T:fullonly
2dual-personalityports;eachportcan
beusedaseitheranRJ-4510/100/1000
port(IEEE802.3Type10BASE-T;IEEE
802.3uType100BASE-TX;IEEE802.3ab
1000BASE-TGigabitEthernet)orasaSFP
slot(forusewithSFPtransceivers)ports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
Physical characteristics
Dimensions
Weight
17.44(w)x10.00(d)x1.75(h)in(44.3x25.4
x4.45cm)(1Uheight)
6.8lb(3.08kg)
17.44(w)x10.00(d)x1.75(h)in(44.3x25.4
x4.45cm)(1Uheight)
6.1lb(2.77kg)
10(w)x6.28(d)x1.75(h)in(25.4x15.95x
4.45cm)(1Uheight)
2.0lb(0.91kg)
Memory and processor
Processor ARM9E@800MHz,128MBash,256
MBDDR3DIMM;packetbuersize:3MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
Mounting and enclosure MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
Performance
100MbLatency
1000MbLatency
Throughput
Switchingcapacity
MACaddresstablesize
IPv6ReadyCertied
<7.4µs(LIFO64-bytepackets)
<2.3µs(LIFO64-bytepackets)
upto77.3millionpps(64-bytepackets)
104Gb/s
16000entries
IPv6ReadyCertied
<7.4µs(LIFO64-bytepackets)
<2.3µs(LIFO64-bytepackets)
upto41.6millionpps(64-bytepackets)
56Gb/s
16000entries
IPv6ReadyCertied
<7.4µs(LIFO64-bytepackets)
<2.6µs(LIFO64-bytepackets)
upto14.8millionpps(64-bytepackets)
20Gb/s
16000entries
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storage
temperature
Nonoperating/Storagerelative
humidity
Altitude
Acoustic
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:34.5dB,Pressure:31.0dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:34.0dB,Pressure:26.4dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:0dB,Pressure:0dB
HP 2530 Switch Series (continued)
Specications (continued)
15
Datasheet|HP2530SwitchSeries
HP 2530-48G Switch (J9775A) HP 2530-24G Switch (J9776A) HP 2530-8G Switch (J9777A)
Electrical characteristics
Frequency
Maximumheatdissipation
ACvoltage
Current
Maximumpowerrating
Idlepower
50/60Hz
AchievedMiercomCertiedGreenAward
203BTU/hr(214.17kJ/hr)
100-127/200-240VAC
1.2/0.7A
59.5W
29.5W
Notes
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
50/60Hz
164BTU/hr(173.02kJ/hr)
100-127/200-240VAC
.6/.4A
48.0W
28.8W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
50/60Hz
63BTU/hr(66.46kJ/hr),
(switchonly:63BTU/hr)
100-127/200-240VAC
0.5A
18.6W
13.6W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
Safety UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
Emissions FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticeld
Voltagedipsandinterruptions
Harmonics
Flicker
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
Notes IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
Services
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
16
Datasheet|HP2530SwitchSeries
HP 2530-48 Switch (J9781A) HP 2530-24 Switch (J9782A) HP 2530-8 Switch (J9783A)
I/O ports and slots 48RJ-45autosensing10/100ports(IEEE
802.3Type10BASE-T,IEEE802.3uType
100BASE-TX);Duplex:halforfull
2autosensing10/100/1000ports(IEEE
802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
2xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
24RJ-45autosensing10/100ports(IEEE
802.3Type10BASE-T,IEEE802.3uType
100BASE-TX);Duplex:halforfull
2autosensing10/100/1000ports(IEEE
802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
2xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
8RJ-45autosensing10/100ports(IEEE
802.3Type10BASE-T,IEEE802.3uType
100BASE-TX);MediaType:Auto-MDIX;
Duplex:halforfull
2dual-personalityports;eachportcan
beusedaseitheranRJ-4510/100/1000
port(IEEE802.3Type10BASE-T;IEEE
802.3uType100BASE-TX;IEEE802.3ab
1000BASE-TGigabitEthernet)orasaSFP
slot(forusewithSFPtransceivers)ports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
Physical characteristics
Dimensions
Weight
17.4(w)x9.7(d)x1.75(h)in(44.2x24.64x
4.45cm)(1Uheight)
6.3lb(2.86kg)
17.4(w)x9.7(d)x1.75(h)in(44.2x24.64x
4.45cm)(1Uheight)
5.7lb(2.59kg)
10(w)x6.28(d)x1.75(h)in(25.4x15.95x
4.45cm)(1Uheight)
1.8lb(0.82kg)
Memory and processor
Processor ARM9E@800MHz,128MBash,256
MBDDR3DIMM;packetbuersize:3MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
Mounting and enclosure MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
Performance
100MbLatency
1000MbLatency
Throughput
Switchingcapacity
MACaddresstablesize
IPv6ReadyCertied
<6.6µs(LIFO64-bytepackets)
<2.2µs(LIFO64-bytepackets)
upto13millionpps(64-bytepackets)
17.6Gb/s
16000entries
IPv6ReadyCertied
<1.7µs(LIFO64-bytepackets)
<1.1µs(LIFO64-bytepackets)
upto9.5millionpps(64-bytepackets)
12.8Gb/s
16000entries
IPv6ReadyCertied
<1.3µs(LIFO64-bytepackets)
<1.3µs(LIFO64-bytepackets)
upto4.1millionpps(64-bytepackets)
5.6Gb/s
16000entries
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storage
temperature
Nonoperating/Storagerelative
humidity
Altitude
Acoustic
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:0dB,Pressure:0dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:0dB,Pressure:0dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:0dB,Pressure:0dB
HP 2530 Switch Series (continued)
Specications (continued)
17
Datasheet|HP2530SwitchSeries
HP 2530-48 Switch (J9781A) HP 2530-24 Switch (J9782A) HP 2530-8 Switch (J9783A)
Electrical characteristics
Frequency
Maximumheatdissipation
ACvoltage
Current
Maximumpowerrating
Idlepower
50/60Hz
102BTU/hr(107.61kJ/hr)
100-127/200-240VAC
0.7/0.4A
29.9W
17.1W
Notes
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
50/60Hz
50BTU/hr(52.75kJ/hr)
100-127/200-240VAC
0.3/0.2A
14.7W
8.4W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
50/60Hz
25BTU/hr(26.38kJ/hr)
100-127/200-240VAC
0.5A
7.2W
4.5W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
Safety UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
Emissions FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticeld
Voltagedipsandinterruptions
Harmonics
Flicker
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
Notes IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
Services
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
18
Datasheet|HP2530SwitchSeries
HP 2530-48G-PoE+-2SFP+ Switch (J9853A) HP 2530-24G-PoE+-2SFP+ Switch (J9854A)
I/O ports and slots 48RJ-45autosensing10/100/1000PoE+ports(IEEE
802.3Type10BASE-T,IEEE802.3uType100BASE-TX,
IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:
halforfull;1000BASE-T:fullonly
2SFP+xed1000/10000SFP+ports
1dual-personality(RJ-45orUSBmicro-B)serialconsole
port
24RJ-45autosensing10/100/1000PoE+ports(IEEE
802.3Type10BASE-T,IEEE802.3uType100BASE-TX,
IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:
halforfull;1000BASE-T:fullonly
2SFP+xed1000/10000SFP+ports
1dual-personality(RJ-45orUSBmicro-B)serialconsole
port
Physical characteristics
Dimensions
Weight
17.44(w)x13.00(d)x1.75(h)in(44.3x32.26x4.45cm)
(1Uheight)
10.4lb(4.72kg)
17.44(w)x13.00(d)x1.75(h)in(44.3x33.02x4.45cm)
(1Uheight)
8.6lb(3.9kg)
Memory and processor
Processor ARM9E@800MHz,128MBash,256MBDDR3DIMM;
packetbuersize:3MBdynamicallyallocated
ARM9E@800MHz,128MBash,256MBDDR3DIMM;
packetbuersize:1.5MBdynamicallyallocated
Mounting and enclosure MountsinanEIA-standard19-inchtelcorackor
equipmentcabinet(rack-mountingkitavailable);
horizontalsurfacemounting;wallmounting
MountsinanEIA-standard19-inchtelcorackor
equipmentcabinet(rack-mountingkitavailable);
horizontalsurfacemounting;wallmounting
Performance
100MbLatency
1000MbLatency
10Gb/sLatency
Throughput
Switchingcapacity
MACaddresstablesize
IPv6ReadyCertied
<7.3µs(LIFO64-bytepackets)
<2.7µs(LIFO64-bytepackets)
<4.0µs(LIFO64-bytepackets)
101Mpps(64-bytepackets)
136Gb/s
16000entries
IPv6ReadyCertied
<7.3µs(LIFO64-bytepackets)
<2.7µs(LIFO64-bytepackets)
<2.2µs(LIFO64-bytepackets)
65.4Mpps(64-bytepackets)
88Gb/s
16000entries
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storagetemperature
Nonoperating/Storagerelativehumidity
Altitude
Acoustic
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:36.4dB,Pressure:30.1dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:31.3dB,Pressure:24dB
HP 2530 Switch Series (continued)
Specications (continued)
19
Datasheet|HP2530SwitchSeries
HP 2530-48G-PoE+-2SFP+ Switch (J9853A) HP 2530-24G-PoE+-2SFP+ Switch (J9854A)
Electrical characteristics
Frequency
Maximumheatdissipation
ACvoltage
Current
Maximumpowerrating
Idlepower
PoEpower
50/60Hz
215BTU/hr(226.83kJ/hr),(switchonly:215BTU/hr;
combinedswitch+max.PoEdevices:1499BTU/hr)
100-127/200-240VAC
5.6/2.8A
439W
40.2W
382W
Notes
Idlepoweristheactualpowerconsumptionofthe
devicewithnoportsconnected.Maximumpowerrating
andmaximumheatdissipationaretheworst-case
theoreticalmaximumnumbersprovidedforplanningthe
infrastructurewithfullyloadedPoE(ifequipped),100%
traic,allportspluggedin,andallmodulespopulated.
PoEpoweristhetotalpowerbudgetavailabletoallPoE
ports.
50/60Hz
118BTU/hr(124.49kJ/hr),(switchonly:118BTU/hr;
combinedswitch+max.PoEdevices:757BTU/hr)
100-127/200-240VAC
2.9/1.4A
222.2W
24.7W
195W
Idlepoweristheactualpowerconsumptionofthe
devicewithnoportsconnected.Maximumpowerrating
andmaximumheatdissipationaretheworst-case
theoreticalmaximumnumbersprovidedforplanningthe
infrastructurewithfullyloadedPoE(ifequipped),100%
traic,allportspluggedin,andallmodulespopulated.
PoEpoweristhetotalpowerbudgetavailabletoallPoE
ports.
Safety UL60950-1;CAN/CSA22.2No.60950-1;EN60825;IEC
60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;EN60825;IEC
60950-1;EN60950-1
Emissions FCCClassA;EN55022/CISPR-22ClassA;VCCIClassA FCCClassA;EN55022/CISPR-22ClassA;VCCIClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticeld
Voltagedipsandinterruptions
Harmonics
Flicker
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-line
interface;Webbrowser;congurationmenu;out-of-band
management(serialRS-232CorMicroUSB);IEEE802.3
EthernetMIB;RepeaterMIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;command-line
interface;Webbrowser;congurationmenu;out-of-band
management(serialRS-232CorMicroUSB);IEEE802.3
EthernetMIB;RepeaterMIB;EthernetInterfaceMIB
Notes IEEE802.3azappliestoGigabitmodelsonly;IEEE802.3at
andIEEE802.3afapplytoPoE+modelsonly.
SFPswithrevision“B”orlater(e.g.,J4858B,J4859C)are
requiredwiththisproduct.Thisproductsupportsonly1
GigabitSFP&10GigabitSFP+transceivers,aswellas10
GigabitDirectAttachCables.
IEEE802.3azappliestoGigabitmodelsonly;IEEE802.3at
andIEEE802.3afapplytoPoE+modelsonly.
SFPswithrevision“B”orlater(e.g.,J4858B,J4859C)are
requiredwiththisproduct.Thisproductsupportsonly1
GigabitSFP&10GigabitSFP+transceivers,aswellas10
GigabitDirectAttachCables.
Services
RefertotheHPwebsiteathp.com/networking/services
fordetailsontheservice-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesandresponsetimes
inyourarea,pleasecontactyourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/networking/services
fordetailsontheservice-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesandresponsetimes
inyourarea,pleasecontactyourlocalHPsalesoice.
20
Datasheet|HP2530SwitchSeries
HP 2530-48G-2SFP+ Switch (J9855A) HP 2530-24G-2SFP+ Switch (J9856A)
I/O ports and slots 48RJ-45autosensing10/100/1000ports(IEEE802.3
Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE
802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
2SFP+xed1000/10000SFP+ports
1dual-personality(RJ-45orUSBmicro-B)serialconsole
port
24RJ-45autosensing10/100/1000ports(IEEE802.3
Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE
802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
2SFP+xed1000/10000SFP+ports
1dual-personality(RJ-45orUSBmicro-B)serialconsole
port
Physical characteristics
Dimensions
Weight
17.44(w)x10.00(d)x1.75(h)in(44.3x25.4x4.45cm)(1U
height)
7.1lb(3.08kg)
17.44(w)x10.00(d)x1.75(h)in(44.3x25.4x4.45cm)
(1Uheight)
6.2lb(2.81kg)
Memory and processor
Processor ARM9E@800MHz,128MBash,256MBDDR3DIMM;
packetbuersize:3MBdynamicallyallocated
ARM9E@800MHz,128MBash,256MBDDR3DIMM;
packetbuersize:1.5MBdynamicallyallocated
Mounting and enclosure MountsinanEIA-standard19-inchtelcorackor
equipmentcabinet(rack-mountingkitavailable);
horizontalsurfacemounting;wallmounting
MountsinanEIA-standard19-inchtelcorackor
equipmentcabinet(rack-mountingkitavailable);
horizontalsurfacemounting;wallmounting
Performance
100MbLatency
1000MbLatency
10Gb/sLatency
Throughput
Switchingcapacity
MACaddresstablesize
IPv6ReadyCertied
<7.3µs(LIFO64-bytepackets)
<2.7µs(LIFO64-bytepackets)
<4.0µs(LIFO64-bytepackets)
101Mpps(64-bytepackets)
136Gb/s
16000entries
IPv6ReadyCertied
<7.3µs(LIFO64-bytepackets)
<2.7µs(LIFO64-bytepackets)
<2.2µs(LIFO64-bytepackets)
65.4Mpps(64-bytepackets)
88Gb/s
16000entries
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storagetemperature
Nonoperating/Storagerelativehumidity
Altitude
Acoustic
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:32.2dB,Pressure:25.6dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:29.4dB,Pressure:22.3dB
HP 2530 Switch Series (continued)
Specications (continued)
/