Hewlett Packard Enterprise J9856A Datasheet

Category
Network switches
Type
Datasheet

This manual is also suitable for

Key features
•Cost-eective,reliable,protectedandfullymanagedL2switches
•8,24,or48GigabitorFastEthernetportswithuptofourGigabitortwo10Gigabituplinkports
•PoE+modelsforvoice,video,andwirelessdeployments
•Accesscontrollists(ACLs),EEE,andIPv4/IPv6hostsupport
•LimitedLifetimeWarranty2.0with3years24x7phonesupport
Product overview
TheHP2530SwitchSeriesconsistsof16fullymanagedL2edgeswitchesthatdelivercost-
eective,reliable,protectedandeasy-to-useconnectivitytobusinessnetworks.Designedfor
entry-leveltomidsizeenterprisenetworks,theseGigabitandFastEthernetswitchesdeliver
fullL2capabilitieswithoptionalPoweroverEthernet(PoE),enhancedaccesssecurity,traic
prioritization,andIPv6hostsupport.
TheHP2530SwitchSeriesoersuplinkexibilitywitheitherfourGigabitortwo10Gigabit
Ethernetuplinksonsome24-and48-portmodels.TheGigabit24-and48-portmodels
haveeithertwosmallform-factorpluggableplus(SFP+)orfoursmallform-factorpluggable
(SFP)slotsforberconnectivity.TheFastEthernet24-and48-portmodelshavetwoSFPs
andtwoRJ-45Gigabituplinks.Thecompactandfan-less8-portswitchesoeradditional
exibilitywithtwodual-personalityportsthatcanbeusedaseitherRJ-45GigabitEthernet
orSFPports.Moreover,theHP2530SwitchSeriesPoE+SwitchesareIEEE802.3af-andIEEE
802.3at-compliantwithupto30Wperport,makingthemsuitableforvoice,video,orwireless
deploymentswithPoE+.
Data sheet
HP 2530 Switch Series
2
Datasheet|HP2530SwitchSeries
Theswitchseriesiseasytouse,deploy,andmanageviatheSNMP,CLI,andWebGUI.Itoers
exiblewall,table,andrackmountingoptions;quietoperationwithfan-lessandvariable-speed
fanmodels;andimprovedpowersavingswithfeaturessuchasIEEE802.3azenergy-eicient
Ethernet.AnditincludesLimitedLifetimeWarranty2.0with3years24x7phonesupportand
includesallsoftwarereleases.
Features and benets
Quality of Service
•Traicprioritization(IEEE802.1p)
Allowsreal-timetraicclassicationwithsupportforeightprioritylevelsmappedtoeither
twoorfourqueues,andusesweighteddecitround-robin(WDRR)orstrictpriority
•Simpliedqualityofservice(QoS)conguration
Port-based
Prioritizestraicbyspecifyingaportandprioritylevel
VLAN-based
PrioritizestraicbyspecifyingaVLANandprioritylevel
•ClassofService(CoS)
SetstheIEEE802.1pprioritytagbasedonIPaddress,IPTypeofService(ToS),Layer3
protocol,TCP/UDPportnumber,sourceport,andDiServ
•Ratelimiting
Establishesper-portingress-enforcedmaximumsforallingressedtraicorforbroadcast,
multicast,orunknowndestinationtraic
•Layer4prioritization
EnablesprioritizationbasedonTCP/UDPportnumbers
•Flowcontrol
Helpsdeliverreliablecommunicationduringfull-duplexoperation
Management
•Choiceofmanagementinterfaces
HTML-basedeasy-to-useWebGUI
AllowscongurationoftheswitchfromanyWebbrowser
RobustCLI
Providesadvancedcongurationanddiagnostics
Simplenetworkmanagementprotocol(SNMPv1/v2c/v3)
Allowstheswitchtobemanagedwithavarietyofthird-partynetworkmanagement
applications
•Virtualstacking
ProvidessingleIPaddressmanagementforupto16switches
•sFlow(RFC3176)
Deliverswire-speedtraicaccountingandmonitoring,conguredbySNMPandCLIwiththree
terminalencryptedreceivers
3
Datasheet|HP2530SwitchSeries
•IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)
Automatesdevicediscoveryprotocolforeasymappingbynetworkmanagementapplications
•Logging
ProvideslocalandremoteloggingofeventsviaSNMP(v2candv3)andsyslog;provideslog
throttlingandloglteringtoreducethenumberoflogeventsgenerated
•Portmirroring
Allowstraictobemirroredonanyportoranetworkanalyzertoassistwithdiagnosticsor
detectingnetworkattacks
•Remotemonitoring(RMON)
Providesadvancedmonitoringandreportingcapabilitiesforstatistics,history,alarms,and
events
•Find,x,andinform
Findsandxescommonnetworkproblemsautomatically,andtheninformstheadministrator
•Friendlyportnames
Allowsassignmentofdescriptivenamestoports
•Dualashimages
Providesindependentprimaryandsecondaryoperatingsystemlesforbackupwhile
upgrading
•Multiplecongurationles
Areeasilystoredwithaashimage
•Front-panelLEDs
LocatorLEDs
AllowsuserstosetthelocatorLEDonaspecicswitchtoturnon,blink,orturno;and
simpliestroubleshootingbymakingiteasytolocateaparticularswitchwithinarackof
similarswitches
Per-portLEDs
Providesanat-a-glanceviewofthestatus,activity,speed,andfull-duplexoperation
PowerandfaultLEDs
Displayissues,ifany
•HPComwareCLI
Comware-compatibleCLI
BridgestheexperienceofHPComwareCLIuserswhoareusingtheHPProVisionsoftware
CLI
DisplayandfundamentalComwareCLIcommands
AreembeddedintheswitchCLIasnativecommands;displayoutputisformattedason
Comware-basedswitches,andfundamentalcommandsprovideaComware-familiarinitial
switchsetup
CongurationComwareCLIcommands
WhenComwarecommandsareentered,CLIhelpselicittoformulatethecorrectProVision
softwareCLIcommand
•NEWDownloadsoftwareviaDHCP
AddstheoptiontospecifythelocationofswitchsoftwareviaDHCP
•NEWTR-069support
Enableszero-touchcongurationforswitches
4
Datasheet|HP2530SwitchSeries
Connectivity
•IPv6
IPv6host
AllowstheswitchtobedeployedandmanagedattheedgeofanIPv6network
Dualstack(IPv4/IPv6)
Supportsconnectivityforbothprotocols;providesatransitionmechanismfromIPv4toIPv6
MLDsnooping
ForwardsIPv6multicasttraictoappropriateinterface;preventsIPv6multicasttraicfrom
oodingthenetwork
IPv6ACL/QoS
SupportsACLandQoSforIPv6networktraiconGigabitand48port10/100models
Security
RAGuard,DHCPv6Protection,DynamicIPv6Lockdown(YAonly)
•IEEE802.3afPoweroverEthernet(PoE)
Providesupto15.4WperporttoIEEE802.3af-compliantPoE-powereddevicessuchasIP
phones,wirelessaccesspoints,andsecuritycameras
•IEEE802.3atPoE+
Providesupto30WperporttoIEEE802.3forPoE/PoE+-powereddevicessuchasvideoIP
phones,IEEE802.11nwirelessaccesspoints,andadvancedpan/tilt/zoomsecuritycameras
(refertotheproductspecicationsforthetotalPoEpoweravailability)
•Auto-MDIX
Adjustsautomaticallyforstraight-throughorcrossovercablesonallports
•Pre-standardPoEsupport
Detectsandprovidespowertopre-standardPoEdevices(refertothelistofsupporteddevices
intheproductFAQs,whichcanbeaccessedathp.com/networking/support)
•SFPslots
ProvidesberconnectivitysuchasGigabit-SX,LX,LH,andBXwithfourSFPslotsonall24-and
48-portGigabitEthernetmodels.FastEthernet24-and48-portmodelshavetwoSFPslots
andtwoRJ-45Gigabituplinks;8-portmodelshavetwodual-personalityportssupporting
eitherSFPorRJ-45Gigabituplinks
•Dual-personality(RJ-45orUSBmicro-B)serialconsoleport
GiveseasyaccesstoswitchCLIwithfront-of-switchlocationandtheexibilityofusingeither
anRJ-45orUSBmicro-Bserialconsoleport
5
Datasheet|HP2530SwitchSeries
Layer 2 switching
•VLANs
Providessupportfor512VLANsand4,094VLANIDs
•Jumbopacketsupport
Supportsupto9,220-byteframesizetoimprovetheperformanceoflargedatatransfers;
8-and24-portFastEthernetmodelsautomaticallysupportupto2,000-byteframeswithno
congurationneeded
•16KMACaddresstable
ProvidesaccesstomanyLayer2devices
•GARPVLANRegistrationProtocol
AllowsautomaticlearninganddynamicassignmentofVLANs
•NEWRapidPer-VLANSpanningTree(RPVST+)
AllowseachVLANtobuildaseparatespanningtreetoimprovelinkbandwidthusage;is
compatiblewithPVST+
Security
•ACLs
AccommodatesIPv4/IPv6portandVLAN-basedACLs(IPv6ACLissupportedonlyonGigabit
Ethernetand48-portmodels.)
•Source-portltering
Allowsonlyspeciedportstocommunicatewitheachother
•RADIUS/TACACS+
Easesswitchmanagementsecurityadministrationbyusingapasswordauthenticationserver
•SecureSocketsLayer(SSL)
EncryptsallHTTPtraic,allowingsecureaccesstothebrowser-basedmanagementGUIinthe
switch
•Portsecurity
AllowsaccessonlytospeciedMACaddresses,whichcanbelearnedorspeciedbythe
administrator
•MACaddresslockout
PreventsparticularconguredMACaddressesfromconnectingtothenetwork
6
Datasheet|HP2530SwitchSeries
•Multipleuserauthenticationmethods
IEEE802.1X
UsesanIEEE802.1XsupplicantontheclientinconjunctionwithaRADIUSserverto
authenticateinaccordancewithindustrystandards
Web-basedauthentication
Providesabrowser-basedenvironment,similartoIEEE802.1X,toauthenticateclientsthat
donotsupporttheIEEE802.1Xsupplicant
MAC-basedauthentication
AuthenticatestheclientwiththeRADIUSserverbasedontheclient’sMACaddress
•Secureshell(SSH)v2
EncryptsalltransmitteddataforsaferemoteCLIaccessoverIPnetworks
•Secureshell
EncryptsalltransmitteddataforsaferemoteCLIaccessoverIPnetworks
•STPBPDUportprotection
BlocksBridgeProtocolDataUnits(BPDUs)onportsthatdonotrequireBPDUs,preventing
forgedBPDUattacks
•STProotguard
Protectstherootbridgefrommaliciousattacksorcongurationmistakes
•Securemanagementaccess
Deliversprotectedencryptionofallaccessmethods(CLI,GUI,orMIB)throughSSHv2and
SNMPv3
•Custombanner
Displayssecuritypolicywhenuserslogintotheswitch
•SecureFTP
Allowssafeletransfertoandfromtheswitch;protectsagainstunwantedledownloadsor
unauthorizedcopyingofaswitchcongurationle
•ProtectedportsCLI
OersintuitiveCLItocongurethesource-portlterfeature,byallowingspeciedportstobe
isolatedfromallotherportsontheswitch;theprotectedportorportscancommunicateonly
withtheuplinkorsharedresources
7
Datasheet|HP2530SwitchSeries
•Authenticationexibility
MultipleIEEE802.1Xusersperport
Providesauthenticationforupto32IEEE802.1Xusersperport;preventsauserfrom
“piggybacking”onanotheruser’sIEEE802.1Xauthentication
ConcurrentIEEE802.1XandWeborMACauthenticationschemesperport
AllowsaswitchporttoacceptanyIEEE802.1XandeitherWeborMACauthentications
•Switchmanagementlogonsecurity
HelpssecureswitchCLIlogonbyoptionallyrequiringeitherRADIUSorTACACS+authentication
•NEWDHCPprotection
BlocksDHCPpacketsfromunauthorizedDHCPservers,preventingdenial-of-serviceattacks
•NEWDynamicARPprotection
BlocksARPbroadcastsfromunauthorizedhosts,preventingeavesdroppingortheftof
networkdata
•NEWDynamicIPlockdown
WorkswithDHCPprotectiontoblocktraicfromunauthorizedhosts,preventingIPsource
addressspoong
Convergence
•IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)
FacilitateseasymappingusingnetworkmanagementapplicationswithLLDPautomated
devicediscoveryprotocol
•LLDP-MED(MediaEndpointDiscovery)
DenesastandardextensionofLLDPthatstoresvaluesforparameterssuchasQoSandVLAN
toautomaticallycongurenetworkdevicessuchasIPphones
•IPmulticast(data-drivenIGMP)
PreventsoodingofIPmulticasttraic
•PoEandPoE+allocations
Supportmultiplemethodsautomatic,IEEE802.3atdynamic,LLDP-MEDnegrain,IEEE
802.3afdeviceclass,oruserspecied—toallocateandmanagePoE/PoE+powerformore
eicientenergyuse
•VoiceVLAN
UsesLLDP-MEDtoautomaticallycongureaVLANforIPphones
•IPmulticast(data-drivenIGMPv3)
PreventsoodingofIPmulticasttraic
•LLDP-CDPcompatibility
ReceivesandrecognizesCDPpacketsfromCisco’sIPphonesforseamlessinteroperation
•NEWLocalMACAuthentication
AssignsattributessuchasVLANandQoSusinglocallyconguredprolethatcanbealistof
MACprexesUniedWiredandWireless
•NEWHTTPredirectfunction
SupportsHPIntelligentManagementCenter(IMC)bringyourowndevice(BYOD)solution
8
Datasheet|HP2530SwitchSeries
Resiliency and high availability
•Porttrunkingandlinkaggregation
Trunking
Supportsuptoeightlinkspertrunktoincreasebandwidthandcreateredundant
connections;andsupportsL2,L3,andL4trunkload-balancingalgorithm(L4trunkload
balancingissupportedonlyonGigabitEthernetand48-portmodels.)
IEEE802.3adLinkAggregationControlProtocol(LACP)
Easescongurationoftrunksthroughautomaticconguration
•IEEE802.1sMultipleSpanningTree
ProvideshighlinkavailabilityinmultipleVLANenvironmentsbyallowingmultiplespanning
trees;provideslegacysupportforIEEE802.1dandIEEE802.1w
•NEWSmartLink
Provideseasy-to-congurelinkredundancyofactiveandstandbylinks
Product architecture
•Energy-eicientdesign
IEEE802.3az
ReducespowerconsumptionduringperiodsoflowdataactivityonGigabitEthernetswitches
Portlow-powermode
Enablestheporttoautomaticallygointolow-powermodetoconserveenergywhennolink
isdetected
Fan-lessandvariable-speedfans
Decreasespowerconsumptioninfan-less(all8-port,2530-24,and2530-48PoE+switches)
aswellasvariable-speedfanswitches
PortLEDs
ConservesenergybyoptionallyturningoportlinkandactivityLEDs
•Switchonachip
Providesahighlyintegrated,high-performanceswitchdesignwithanonblockingarchitecture
9
Datasheet|HP2530SwitchSeries
Flexibility
•Flexiblemounting
Rackmountable
Allowstheswitchtobemountedonastandard19-inchrack,withthehardwareincluded
Wallmountable
Allowstheswitchtobemountedonawall,usingthehardwareincluded
Surfacemountable
Allowstheswitchtobemountedaboveorbelowasurface(suchasadeskortable),using
thehardwareincluded
•Quietoperation
Lowersnoise,makingitsuitablefordeploymentsinacousticallysensitiveenvironmentssuch
asconferenceroomsandoicespaces
•Compactsize
Reducesspacerequirements(refertotheproductspecicationsfortheexactdimensions)
Warranty and support
•LimitedLifetimeWarranty2.0
Advancehardwarereplacementwithnext-business-daydelivery(availableinmostcountries).
Seehp.com/networking/warrantysummaryfordurationdetails
•Electronicandtelephonesupport(forLimitedLifetimeWarranty2.0)
Limited24x7telephonesupportisavailablefromHPfortherst3years;limitedelectronic
andbusinesshourstelephonesupportisavailablefromHPfortheentirewarrantyperiod;
toreachoursupportcenters,refertohp.com/networking/contact-support;fordetailson
thedurationofsupportprovidedwithyourproductpurchase,refertohp.com/networking/
warrantysummary
•Softwarereleases
Tondsoftwareforyourproduct,refertohp.com/networking/support;fordetailsonthe
softwarereleasesavailablewithyourproductpurchase,refertohp.com/networking/
warrantysummary
10
Datasheet|HP2530SwitchSeries
HP 2530 Switch Series
Specications
HP 2530-48G-PoE+ Switch (J9772A) HP 2530-24G-PoE+ Switch (J9773A) HP 2530-8G-PoE+ Switch (J9774A)
I/O ports and slots 48RJ-45autosensing10/100/1000PoE+
ports(IEEE802.3Type10BASE-T,IEEE
802.3uType100BASE-TX,IEEE802.3ab
Type1000BASE-T,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:10BASE-
T/100BASE-TX:halforfull;1000BASE-T:
fullonly
4xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
24RJ-45autosensing10/100/1000PoE+
ports(IEEE802.3Type10BASE-T,IEEE
802.3uType100BASE-TX,IEEE802.3ab
Type1000BASE-T,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:10BASE-
T/100BASE-TX:halforfull;1000BASE-T:
fullonly
4xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
8RJ-45autosensing10/100/1000PoE+
ports(IEEE802.3Type10BASE-T,IEEE
802.3uType100BASE-TX,IEEE802.3ab
Type1000BASE-T,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:10BASE-
T/100BASE-TX:halforfull;1000BASE-T:
fullonly
2dual-personalityports;eachportcan
beusedaseitheranRJ-4510/100/1000
port(IEEE802.3Type10BASE-T;IEEE
802.3uType100BASE-TX;IEEE802.3ab
1000BASE-TGigabitEthernet)orasaSFP
slot(forusewithSFPtransceivers)
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
Physical characteristics
Dimensions
Weight
17.44(w)x13.00(d)x1.75(h)in(44.3x
32.26x4.45cm)(1Uheight)
10.4lb(4.72kg)
17.44(w)x13.00(d)x1.75(h)in(44.3x
33.02x4.45cm)(1Uheight)
8.7lb(3.95kg)
10(w)x6.28(d)x1.75(h)in(25.4x15.95x
4.45cm)(1Uheight)
2.2lb(1kg)
Memory and processor
Processor ARM9E@800MHz,128MBash,256
MBDDR3DIMM;packetbuersize:3MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
Mounting and enclosure MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
Performance
100MbLatency
1000MbLatency
Throughput
Switchingcapacity
MACaddresstablesize
IPv6ReadyCertied
<7.4µs(LIFO64-bytepackets)
<2.3µs(LIFO64-bytepackets)
upto77.3millionpps(64-bytepackets)
104Gb/s
16000entries
IPv6ReadyCertied
<7.4µs(LIFO64-bytepackets)
<2.3µs(LIFO64-bytepackets)
upto41.6millionpps(64-bytepackets)
56Gb/s
16000entries
IPv6ReadyCertied
<7.4µs(LIFO64-bytepackets)
<2.6µs(LIFO64-bytepackets)
upto14.8millionpps(64-bytepackets)
20Gb/s
16000entries
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storage
temperature
Nonoperating/Storagerelative
humidity
Altitude
Acoustic
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),
noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),
noncondensing
upto10,000ft(3km)
Power:43.6dB,Pressure:33.6dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),
noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),
noncondensing
upto10,000ft(3km)
Power:43.9dB,Pressure:39.6dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),
noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),
noncondensing
upto10,000ft(3km)
Power:0dB,Pressure:0dB
11
Datasheet|HP2530SwitchSeries
HP 2530-48G-PoE+ Switch (J9772A) HP 2530-24G-PoE+ Switch (J9773A) HP 2530-8G-PoE+ Switch (J9774A)
Electrical characteristics
Frequency
Maximumheatdissipation
ACvoltage
Current
Maximumpowerrating
Idlepower
PoEpower
50/60Hz
236BTU/hr(248.98kJ/hr),(switchonly:
236BTU/hr;combinedswitch+max.PoE
devices:1624BTU/hr)
100-127/200-240VAC
5.8/2.9A
476W
40.1W
382W
Notes
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
PoEpoweristhetotalpowerbudget
availabletoallPoEports.
50/60Hz
135BTU/hr(142.42kJ/hr),(switchonly:
135BTU/hr;combinedswitch+max.PoE
devices:843BTU/hr)
100-127/200-240VAC
3.2/1.6A
247W
25.2W
195W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
PoEpoweristhetotalpowerbudget
availabletoallPoEports.
50/60Hz
65BTU/hr(68.58kJ/hr),(switchonly:
65BTU/hr;combinedswitch+max.PoE
devices:293BTU/hr)
100-127/200-240VAC
1.4A
86W
13.4W
67W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
PoEpoweristhetotalpowerbudget
availabletoallPoEports.
Safety UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
Emissions FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticeld
Voltagedipsandinterruptions
Harmonics
Flicker
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
Notes IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
Services
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
12
Datasheet|HP2530SwitchSeries
HP 2530 Switch Series (continued)
Specications (continued)
HP 2530-48-PoE+ Switch (J9778A) HP 2530-24-PoE+ Switch (J9779A) HP 2530-8-PoE+ Switch (J9780A)
I/O ports and slots 48RJ-45autosensing10/100PoE+ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:halforfull
2autosensing10/100/1000ports(IEEE
802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
2xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
24RJ-45autosensing10/100PoE+ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:halforfull
2autosensing10/100/1000ports(IEEE
802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
2xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
8RJ-45autosensing10/100PoE+ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:halforfull
2dual-personalityports;eachportcan
beusedaseitheranRJ-4510/100/1000
port(IEEE802.3Type10BASE-T;IEEE
802.3uType100BASE-TX;IEEE802.3ab
1000BASE-TGigabitEthernet)orasaSFP
slot(forusewithSFPtransceivers)ports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
Physical characteristics
Dimensions
Weight
17.4(w)x12.7(d)x1.75(h)in(44.2x32.26x
4.45cm)(1Uheight)
10.1lb(4.58kg)
17.4(w)x12.7(d)x1.75(h)in(44.2x32.26x
4.45cm)(1Uheight)
8.4lb(3.81kg)
10(w)x6.28(d)x1.75(h)in(25.4x15.95x
4.45cm)(1Uheight)
2.0lb(0.91kg)
Memory and processor
Processor ARM9E@800MHz,128MBash,256
MBDDR3DIMM;packetbuersize:3MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
Mounting and enclosure MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
Performance
100MbLatency
1000MbLatency
Throughput
Switchingcapacity
MACaddresstablesize
IPv6ReadyCertied
<6.6µs(LIFO64-bytepackets)
<2.2µs(LIFO64-bytepackets)
upto13millionpps(64-bytepackets)
17.6Gb/s
16000entries
IPv6ReadyCertied
<1.7µs(LIFO64-bytepackets)
<1.1µs(LIFO64-bytepackets)
upto9.5millionpps(64-bytepackets)
12.8Gb/s
16000entries
IPv6ReadyCertied
<1.3µs(LIFO64-bytepackets)
<2.3µs(LIFO64-bytepackets)
upto4.1millionpps(64-bytepackets)
5.6Gb/s
16000entries
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storage
temperature
Nonoperating/Storagerelative
humidity
Altitude
Acoustic
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:37.9dB,Pressure:31.8dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:40.4dB,Pressure:31.7dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:0dB,Pressure:0dB
13
Datasheet|HP2530SwitchSeries
HP 2530-48-PoE+ Switch (J9778A) HP 2530-24-PoE+ Switch (J9779A) HP 2530-8-PoE+ Switch (J9780A)
Electrical characteristics
Frequency
Maximumheatdissipation
ACvoltage
Current
Maximumpowerrating
Idlepower
PoEpower
50/60Hz
170BTU/hr(179.35kJ/hr),(switchonly:
170BTU/hr;combinedswitch+max.PoE
devices:1505BTU/hr)
100-127/200-240VAC
5.2/2.6A
441W
37.5W
382W
Notes
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
PoEpoweristhetotalpowerbudget
availabletoallPoEports.
50/60Hz
99BTU/hr(104.45kJ/hr),(switchonly:
99BTU/hr;combinedswitch+max.PoE
devices:809BTU/hr)
100-127/200-240VAC
2.8/1.4A
237W
21.8W
195W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
PoEpoweristhetotalpowerbudget
availabletoallPoEports.
50/60Hz
29BTU/hr(30.6kJ/hr),(switchonly:29
BTU/hr;combinedswitch+max.PoE
devices:262BTU/hr)
100-127/200-240VAC
1.4A
76.7W
5.8W
67W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
PoEpoweristhetotalpowerbudget
availabletoallPoEports.
Safety UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
Emissions FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticeld
Voltagedipsandinterruptions
Harmonics
Flicker
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
Notes IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
Services
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
14
Datasheet|HP2530SwitchSeries
HP 2530-48G Switch (J9775A) HP 2530-24G Switch (J9776A) HP 2530-8G Switch (J9777A)
I/O ports and slots 48RJ-45autosensing10/100/1000ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
4xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
24RJ-45autosensing10/100/1000ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
4xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
8RJ-45autosensing10/100/1000ports
(IEEE802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);MediaType:Auto-MDIX;
Duplex:10BASE-T/100BASE-TX:halfor
full;1000BASE-T:fullonly
2dual-personalityports;eachportcan
beusedaseitheranRJ-4510/100/1000
port(IEEE802.3Type10BASE-T;IEEE
802.3uType100BASE-TX;IEEE802.3ab
1000BASE-TGigabitEthernet)orasaSFP
slot(forusewithSFPtransceivers)ports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
Physical characteristics
Dimensions
Weight
17.44(w)x10.00(d)x1.75(h)in(44.3x25.4
x4.45cm)(1Uheight)
6.8lb(3.08kg)
17.44(w)x10.00(d)x1.75(h)in(44.3x25.4
x4.45cm)(1Uheight)
6.1lb(2.77kg)
10(w)x6.28(d)x1.75(h)in(25.4x15.95x
4.45cm)(1Uheight)
2.0lb(0.91kg)
Memory and processor
Processor ARM9E@800MHz,128MBash,256
MBDDR3DIMM;packetbuersize:3MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
Mounting and enclosure MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
Performance
100MbLatency
1000MbLatency
Throughput
Switchingcapacity
MACaddresstablesize
IPv6ReadyCertied
<7.4µs(LIFO64-bytepackets)
<2.3µs(LIFO64-bytepackets)
upto77.3millionpps(64-bytepackets)
104Gb/s
16000entries
IPv6ReadyCertied
<7.4µs(LIFO64-bytepackets)
<2.3µs(LIFO64-bytepackets)
upto41.6millionpps(64-bytepackets)
56Gb/s
16000entries
IPv6ReadyCertied
<7.4µs(LIFO64-bytepackets)
<2.6µs(LIFO64-bytepackets)
upto14.8millionpps(64-bytepackets)
20Gb/s
16000entries
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storage
temperature
Nonoperating/Storagerelative
humidity
Altitude
Acoustic
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:34.5dB,Pressure:31.0dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:34.0dB,Pressure:26.4dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:0dB,Pressure:0dB
HP 2530 Switch Series (continued)
Specications (continued)
15
Datasheet|HP2530SwitchSeries
HP 2530-48G Switch (J9775A) HP 2530-24G Switch (J9776A) HP 2530-8G Switch (J9777A)
Electrical characteristics
Frequency
Maximumheatdissipation
ACvoltage
Current
Maximumpowerrating
Idlepower
50/60Hz
AchievedMiercomCertiedGreenAward
203BTU/hr(214.17kJ/hr)
100-127/200-240VAC
1.2/0.7A
59.5W
29.5W
Notes
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
50/60Hz
164BTU/hr(173.02kJ/hr)
100-127/200-240VAC
.6/.4A
48.0W
28.8W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
50/60Hz
63BTU/hr(66.46kJ/hr),
(switchonly:63BTU/hr)
100-127/200-240VAC
0.5A
18.6W
13.6W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
Safety UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
Emissions FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticeld
Voltagedipsandinterruptions
Harmonics
Flicker
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
Notes IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
Services
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
16
Datasheet|HP2530SwitchSeries
HP 2530-48 Switch (J9781A) HP 2530-24 Switch (J9782A) HP 2530-8 Switch (J9783A)
I/O ports and slots 48RJ-45autosensing10/100ports(IEEE
802.3Type10BASE-T,IEEE802.3uType
100BASE-TX);Duplex:halforfull
2autosensing10/100/1000ports(IEEE
802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
2xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
24RJ-45autosensing10/100ports(IEEE
802.3Type10BASE-T,IEEE802.3uType
100BASE-TX);Duplex:halforfull
2autosensing10/100/1000ports(IEEE
802.3Type10BASE-T,IEEE802.3u
Type100BASE-TX,IEEE802.3abType
1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
2xedGigabitEthernetSFPports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
8RJ-45autosensing10/100ports(IEEE
802.3Type10BASE-T,IEEE802.3uType
100BASE-TX);MediaType:Auto-MDIX;
Duplex:halforfull
2dual-personalityports;eachportcan
beusedaseitheranRJ-4510/100/1000
port(IEEE802.3Type10BASE-T;IEEE
802.3uType100BASE-TX;IEEE802.3ab
1000BASE-TGigabitEthernet)orasaSFP
slot(forusewithSFPtransceivers)ports
1dual-personality(RJ-45orUSBmicro-B)
serialconsoleport
Physical characteristics
Dimensions
Weight
17.4(w)x9.7(d)x1.75(h)in(44.2x24.64x
4.45cm)(1Uheight)
6.3lb(2.86kg)
17.4(w)x9.7(d)x1.75(h)in(44.2x24.64x
4.45cm)(1Uheight)
5.7lb(2.59kg)
10(w)x6.28(d)x1.75(h)in(25.4x15.95x
4.45cm)(1Uheight)
1.8lb(0.82kg)
Memory and processor
Processor ARM9E@800MHz,128MBash,256
MBDDR3DIMM;packetbuersize:3MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
ARM9E@800MHz,128MBash,256MB
DDR3DIMM;packetbuersize:1.5MB
dynamicallyallocated
Mounting and enclosure MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
MountsinanEIA-standard19-inchtelco
rackorequipmentcabinet(rack-mounting
kitavailable);horizontalsurfacemounting;
wallmounting
Performance
100MbLatency
1000MbLatency
Throughput
Switchingcapacity
MACaddresstablesize
IPv6ReadyCertied
<6.6µs(LIFO64-bytepackets)
<2.2µs(LIFO64-bytepackets)
upto13millionpps(64-bytepackets)
17.6Gb/s
16000entries
IPv6ReadyCertied
<1.7µs(LIFO64-bytepackets)
<1.1µs(LIFO64-bytepackets)
upto9.5millionpps(64-bytepackets)
12.8Gb/s
16000entries
IPv6ReadyCertied
<1.3µs(LIFO64-bytepackets)
<1.3µs(LIFO64-bytepackets)
upto4.1millionpps(64-bytepackets)
5.6Gb/s
16000entries
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storage
temperature
Nonoperating/Storagerelative
humidity
Altitude
Acoustic
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:0dB,Pressure:0dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:0dB,Pressure:0dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:0dB,Pressure:0dB
HP 2530 Switch Series (continued)
Specications (continued)
17
Datasheet|HP2530SwitchSeries
HP 2530-48 Switch (J9781A) HP 2530-24 Switch (J9782A) HP 2530-8 Switch (J9783A)
Electrical characteristics
Frequency
Maximumheatdissipation
ACvoltage
Current
Maximumpowerrating
Idlepower
50/60Hz
102BTU/hr(107.61kJ/hr)
100-127/200-240VAC
0.7/0.4A
29.9W
17.1W
Notes
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
50/60Hz
50BTU/hr(52.75kJ/hr)
100-127/200-240VAC
0.3/0.2A
14.7W
8.4W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
50/60Hz
25BTU/hr(26.38kJ/hr)
100-127/200-240VAC
0.5A
7.2W
4.5W
Idlepoweristheactualpowerconsumption
ofthedevicewithnoportsconnected.
Maximumpowerratingandmaximumheat
dissipationaretheworst-casetheoretical
maximumnumbersprovidedforplanning
theinfrastructurewithfullyloadedPoE(if
equipped),100%traic,allportsplugged
in,andallmodulespopulated.
Safety UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;
EN60825;IEC60950-1;EN60950-1
Emissions FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
FCCClassA;EN55022/CISPR-22ClassA;
VCCIClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticeld
Voltagedipsandinterruptions
Harmonics
Flicker
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;
command-lineinterface;Webbrowser;
congurationmenu;out-of-band
management(serialRS-232CorMicro
USB);IEEE802.3EthernetMIB;Repeater
MIB;EthernetInterfaceMIB
Notes IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
IEEE802.3azappliestoGigabitmodels
only;IEEE802.3atandIEEE802.3afapply
toPoE+modelsonly.WhenusingSFPswith
thisproduct,SFPswithrevision“B”orlater
(productnumberendswiththeletter“B”or
later,e.g.,J4858B,J4859C)arerequired.
Services
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/
networking/servicesfordetailsonthe
service-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesand
responsetimesinyourarea,pleasecontact
yourlocalHPsalesoice.
18
Datasheet|HP2530SwitchSeries
HP 2530-48G-PoE+-2SFP+ Switch (J9853A) HP 2530-24G-PoE+-2SFP+ Switch (J9854A)
I/O ports and slots 48RJ-45autosensing10/100/1000PoE+ports(IEEE
802.3Type10BASE-T,IEEE802.3uType100BASE-TX,
IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:
halforfull;1000BASE-T:fullonly
2SFP+xed1000/10000SFP+ports
1dual-personality(RJ-45orUSBmicro-B)serialconsole
port
24RJ-45autosensing10/100/1000PoE+ports(IEEE
802.3Type10BASE-T,IEEE802.3uType100BASE-TX,
IEEE802.3abType1000BASE-T,IEEE802.3atPoE+);
MediaType:Auto-MDIX;Duplex:10BASE-T/100BASE-TX:
halforfull;1000BASE-T:fullonly
2SFP+xed1000/10000SFP+ports
1dual-personality(RJ-45orUSBmicro-B)serialconsole
port
Physical characteristics
Dimensions
Weight
17.44(w)x13.00(d)x1.75(h)in(44.3x32.26x4.45cm)
(1Uheight)
10.4lb(4.72kg)
17.44(w)x13.00(d)x1.75(h)in(44.3x33.02x4.45cm)
(1Uheight)
8.6lb(3.9kg)
Memory and processor
Processor ARM9E@800MHz,128MBash,256MBDDR3DIMM;
packetbuersize:3MBdynamicallyallocated
ARM9E@800MHz,128MBash,256MBDDR3DIMM;
packetbuersize:1.5MBdynamicallyallocated
Mounting and enclosure MountsinanEIA-standard19-inchtelcorackor
equipmentcabinet(rack-mountingkitavailable);
horizontalsurfacemounting;wallmounting
MountsinanEIA-standard19-inchtelcorackor
equipmentcabinet(rack-mountingkitavailable);
horizontalsurfacemounting;wallmounting
Performance
100MbLatency
1000MbLatency
10Gb/sLatency
Throughput
Switchingcapacity
MACaddresstablesize
IPv6ReadyCertied
<7.3µs(LIFO64-bytepackets)
<2.7µs(LIFO64-bytepackets)
<4.0µs(LIFO64-bytepackets)
101Mpps(64-bytepackets)
136Gb/s
16000entries
IPv6ReadyCertied
<7.3µs(LIFO64-bytepackets)
<2.7µs(LIFO64-bytepackets)
<2.2µs(LIFO64-bytepackets)
65.4Mpps(64-bytepackets)
88Gb/s
16000entries
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storagetemperature
Nonoperating/Storagerelativehumidity
Altitude
Acoustic
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:36.4dB,Pressure:30.1dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:31.3dB,Pressure:24dB
HP 2530 Switch Series (continued)
Specications (continued)
19
Datasheet|HP2530SwitchSeries
HP 2530-48G-PoE+-2SFP+ Switch (J9853A) HP 2530-24G-PoE+-2SFP+ Switch (J9854A)
Electrical characteristics
Frequency
Maximumheatdissipation
ACvoltage
Current
Maximumpowerrating
Idlepower
PoEpower
50/60Hz
215BTU/hr(226.83kJ/hr),(switchonly:215BTU/hr;
combinedswitch+max.PoEdevices:1499BTU/hr)
100-127/200-240VAC
5.6/2.8A
439W
40.2W
382W
Notes
Idlepoweristheactualpowerconsumptionofthe
devicewithnoportsconnected.Maximumpowerrating
andmaximumheatdissipationaretheworst-case
theoreticalmaximumnumbersprovidedforplanningthe
infrastructurewithfullyloadedPoE(ifequipped),100%
traic,allportspluggedin,andallmodulespopulated.
PoEpoweristhetotalpowerbudgetavailabletoallPoE
ports.
50/60Hz
118BTU/hr(124.49kJ/hr),(switchonly:118BTU/hr;
combinedswitch+max.PoEdevices:757BTU/hr)
100-127/200-240VAC
2.9/1.4A
222.2W
24.7W
195W
Idlepoweristheactualpowerconsumptionofthe
devicewithnoportsconnected.Maximumpowerrating
andmaximumheatdissipationaretheworst-case
theoreticalmaximumnumbersprovidedforplanningthe
infrastructurewithfullyloadedPoE(ifequipped),100%
traic,allportspluggedin,andallmodulespopulated.
PoEpoweristhetotalpowerbudgetavailabletoallPoE
ports.
Safety UL60950-1;CAN/CSA22.2No.60950-1;EN60825;IEC
60950-1;EN60950-1
UL60950-1;CAN/CSA22.2No.60950-1;EN60825;IEC
60950-1;EN60950-1
Emissions FCCClassA;EN55022/CISPR-22ClassA;VCCIClassA FCCClassA;EN55022/CISPR-22ClassA;VCCIClassA
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Powerfrequencymagneticeld
Voltagedipsandinterruptions
Harmonics
Flicker
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
EN55024,CISPR24
EN55024,CISPR24
IEC61000-4-2
IEC61000-4-3
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
EN61000-3-2,IEC61000-3-2
EN61000-3-3,IEC61000-3-3
Management IMC—IntelligentManagementCenter;command-line
interface;Webbrowser;congurationmenu;out-of-band
management(serialRS-232CorMicroUSB);IEEE802.3
EthernetMIB;RepeaterMIB;EthernetInterfaceMIB
IMC—IntelligentManagementCenter;command-line
interface;Webbrowser;congurationmenu;out-of-band
management(serialRS-232CorMicroUSB);IEEE802.3
EthernetMIB;RepeaterMIB;EthernetInterfaceMIB
Notes IEEE802.3azappliestoGigabitmodelsonly;IEEE802.3at
andIEEE802.3afapplytoPoE+modelsonly.
SFPswithrevision“B”orlater(e.g.,J4858B,J4859C)are
requiredwiththisproduct.Thisproductsupportsonly1
GigabitSFP&10GigabitSFP+transceivers,aswellas10
GigabitDirectAttachCables.
IEEE802.3azappliestoGigabitmodelsonly;IEEE802.3at
andIEEE802.3afapplytoPoE+modelsonly.
SFPswithrevision“B”orlater(e.g.,J4858B,J4859C)are
requiredwiththisproduct.Thisproductsupportsonly1
GigabitSFP&10GigabitSFP+transceivers,aswellas10
GigabitDirectAttachCables.
Services
RefertotheHPwebsiteathp.com/networking/services
fordetailsontheservice-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesandresponsetimes
inyourarea,pleasecontactyourlocalHPsalesoice.
RefertotheHPwebsiteathp.com/networking/services
fordetailsontheservice-leveldescriptionsandproduct
numbers.Fordetailsaboutservicesandresponsetimes
inyourarea,pleasecontactyourlocalHPsalesoice.
20
Datasheet|HP2530SwitchSeries
HP 2530-48G-2SFP+ Switch (J9855A) HP 2530-24G-2SFP+ Switch (J9856A)
I/O ports and slots 48RJ-45autosensing10/100/1000ports(IEEE802.3
Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE
802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
2SFP+xed1000/10000SFP+ports
1dual-personality(RJ-45orUSBmicro-B)serialconsole
port
24RJ-45autosensing10/100/1000ports(IEEE802.3
Type10BASE-T,IEEE802.3uType100BASE-TX,IEEE
802.3abType1000BASE-T);Duplex:10BASE-T/100BASE-
TX:halforfull;1000BASE-T:fullonly
2SFP+xed1000/10000SFP+ports
1dual-personality(RJ-45orUSBmicro-B)serialconsole
port
Physical characteristics
Dimensions
Weight
17.44(w)x10.00(d)x1.75(h)in(44.3x25.4x4.45cm)(1U
height)
7.1lb(3.08kg)
17.44(w)x10.00(d)x1.75(h)in(44.3x25.4x4.45cm)
(1Uheight)
6.2lb(2.81kg)
Memory and processor
Processor ARM9E@800MHz,128MBash,256MBDDR3DIMM;
packetbuersize:3MBdynamicallyallocated
ARM9E@800MHz,128MBash,256MBDDR3DIMM;
packetbuersize:1.5MBdynamicallyallocated
Mounting and enclosure MountsinanEIA-standard19-inchtelcorackor
equipmentcabinet(rack-mountingkitavailable);
horizontalsurfacemounting;wallmounting
MountsinanEIA-standard19-inchtelcorackor
equipmentcabinet(rack-mountingkitavailable);
horizontalsurfacemounting;wallmounting
Performance
100MbLatency
1000MbLatency
10Gb/sLatency
Throughput
Switchingcapacity
MACaddresstablesize
IPv6ReadyCertied
<7.3µs(LIFO64-bytepackets)
<2.7µs(LIFO64-bytepackets)
<4.0µs(LIFO64-bytepackets)
101Mpps(64-bytepackets)
136Gb/s
16000entries
IPv6ReadyCertied
<7.3µs(LIFO64-bytepackets)
<2.7µs(LIFO64-bytepackets)
<2.2µs(LIFO64-bytepackets)
65.4Mpps(64-bytepackets)
88Gb/s
16000entries
Environment
Operatingtemperature
Operatingrelativehumidity
Nonoperating/Storagetemperature
Nonoperating/Storagerelativehumidity
Altitude
Acoustic
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:32.2dB,Pressure:25.6dB
32°Fto11F(0°Cto45°C)
15%to95%@104°F(4C),noncondensing
-40°Fto158°F(-40°Cto70°C)
15%to90%@149°F(65°C),noncondensing
upto10,000ft(3km)
Power:29.4dB,Pressure:22.3dB
HP 2530 Switch Series (continued)
Specications (continued)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Hewlett Packard Enterprise J9856A Datasheet

Category
Network switches
Type
Datasheet
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI