Panamax P360-8 User manual

Type
User manual
TM
Instruction
Manual
for the
P360-8
This Package Includes:
(1) POWER360 Eight Outlet Surge Protector
(2) Modular USB charging stations
(2) 6’ micro-USB to USB cables
(to connect charging station to base unit)
(2) Rubber feet for charging modules
(1) User manual
POWER360 Features
8 AC Outlets
8 surge protected AC outlets.
2 Modular Dual-Port USB chargers
Each Charging Station can charge up to two
devices simultaneously (2.1A capacity).
Protect or Disconnect
Keeps electronics safe from power spikes by
disconnecting load in a catastrophic event.
SmartGuard
Protects against brownouts and dangerous
over-voltage conditions. Disconnects the
power when the incoming voltage falls below
95 Volts or rises above 140 Volts. Reconnects
when the voltage returns to a safe level.
Circle of Protection
LED indicator monitors the outlet wiring,
voltage and protection status.
Coax and Telco Protection
Protects from surges on coax and telephone
signal lines, while maintaining full bandwidth
for high denition video and high speed
internet cable/DSL connections.
Lifetime Warranty
Limited lifetime product warranty
plus $500,000 connected equipment
protection policy.
Características de POWER360
8 enchufes de corriente alterna
8 enchufes de corriente alterna protegidos
contra sobretensión.
2 cargadoresUSBmodulares de dos
puertos
Cada estación de carga puede cargar hasta dos
dispositivos al mismo tiempo (capacidad 2.1A).
Tecnología de protección
Protege los productos electrónicos de picos
de energía al desconectarlos en caso de que se
produzcan incidentes.
Protección inteligente
Protege contra caídas de tensión y condiciones
peligrosas de sobretensión. Desconecta la corriente
cuando la tensión entrante cae por debajo de los
95 voltios o sube por encima de los 140 voltios.
Se reconecta cuando la tensión vuelve a un nivel
seguro.
Círculo de protección
El indicador LED reeja el estado del cableado de
los enchufes, el voltaje y la protección.
Coaxial y Protección Telco
Protege de sobretensiones en líneas coaxiales y
de señal de teléfono, manteniendo un ancho de
banda completo para video de alta denición y
las conexiones de cable/DSL de alta velocidad de
Internet.
Garantía de por vida
Garantía de producto limitada de por vida, más
políticade protección de 500 000$ para equipos
conectados.
POWER360 Caractéristiques
8 prises AC
8 Protecteurs de surtensions pour prises AC
2 Chargeurs modulaires à double ports
USB
Chaque station de chargement peut charger jusqu’à
deux appareils simultanément (capacité de 2,1 A).
Protéger ou Déconnecter
Protège votre équipement électronique en le
connectant en cas de hausse de tension lors d’un
sinistre.
SmartGuard
Protège contre les baisses de tension et les
conditions de surtension dangereuses. Déconnecte
l’alimentation lorsque la tension d’entrée tombe
en dessous de 95 Volts ou s’élève au-dessus de 140
Volts, puis la reconnecte lorsque la tension retrouve
un niveau stable et sûr.
Cercle de protection
L’indicateur LED surveille l’état du câblage de sortie,
de la tension et de la protection.
Protection Coaxiale et téléphonique
Protège les lignes téléphoniques et les câbles
coaxiaux contre les surtensions tout en maintenant
la totalité de la bande passante de connexions
internet câble/ADSL pour vous assurer une vitesse
exceptionnelle et des vios en haute dénition.
Garantie à vie
Garantie limitée à vie du produit en complément
d’une politique de protection d’équipement
connecté de $ 500,000.
Este paquete incluye:
(1) Protector de sobretensión con ocho enchufes
POWER360
(2) Estación de carga por USB modular.
(2) Cable de 1,8 m de micro-USB a USB.
(Para conectar la estación de carga a la unidad
base)
(2) Pies de goma para el módulo de carga
(1) Manual del usuario
Ce pack comprend :
(1) Huit protections de surtension murales
POWER360
(2) Stations modulaires de chargement USB
(2) Câble micro-USB vers USB (6 pouces)
(pour connecter la station de charge à l'unité de
base)
(2) Les pieds en caoutchouc pour le module
(1) Guilde d'utilisateur
English
Properly Connecting Your
PANAMAX POWER360
To completely protect your equipment from surges, every wire leading
into or out of the equipment you want to protect must be connected
to the appropriate Panamax surge protector. Damaging lightning and
power surges can enter your system through any AC power or signal-line
(phone line, grounding wires, coax cables, modem cables, LAN cables,
etc.) connected to your electronic equipment.
The Panamax Connected Equipment Protection Policy is void if any
wire leading into or out of the equipment is not properly connected to
the appropriate Panamax surge protector. The surge protector must also
be plugged into a properly wired and grounded outlet. Please see the
warranty for details or contact the Panamax Tech Support Department
with questions.
Important Safety Points
Panamax POWER360 and the connected equipment must be indoors,
in a dry location and in the same building. Although your Panamax
POWER360 is very durable, its internal components are not isolated from
the environment. Do not install any Panamax product near heat emitting
appliances such as a radiator or heat register. Do not install this product
where excessive moisture is present; for example near a bathtub, sink,
pool, basement oor, sh tank, etc. It is not uncommon for a building to
be improperly grounded. In order to protect your equipment, Panamax
products must be plugged into a properly wired and grounded 3-wire
outlet. Additionally, building wiring and grounding must conform to
applicable NEC (USA) or CEC (Canada) codes for the Panamax protection
policy to be valid.
Circle of Protection
The CIRCLE OF PROTECTION provides peace of mind that your connected
equipment is safe. When all lights are blue, you can rest assured that
your electronics are protected.
1. PROTECTED
BLUE indicates that the POWER360 is functioning properly and that
all connected equipment is protected. OFF indicates that the power
is disconnected from the outlets. If this light is OFF and the VOLTAGE
light is illuminated BLUE, then the PROTECT OR DISCONNECT feature
in your POWER360 has protected your equipment from a catastrophic
surge event and disconnected power. Unplug all electronics from your
POWER360 and contact Panamax Tech Support for assistance.
2. WIRING
BLUE indicates that the wall outlet is properly wired and grounded.
RED indicates an open ground (no ground wire) or reverse wiring
(polarity) condition is detected. Unplug all electronics from your
POWER360 and contact Panamax Tech Support for assistance.
3. VOLTAGE
BLUE indicates that incoming voltage is within a safe range.
RED indicates an over-voltage or brownout condition and that
POWER360 has disconnected power to connected equipment to keep it
safe. POWER360 will automatically reset when voltage is back within a
safe range. If condition persists, it is advisable to contact an electrician
or your power company to determine the cause of the abnormal voltage
issue.
Installation
NOTE to TV ANTENNA, SATELLITE DISH and CATV INSTALLERS:
Articles 810.21 and 820.40 of the NEC provide specic guidelines for
proper grounding, and in particular, specify that the cable ground shall
be connected to the grounding system of the building, as close to the
point of cable entry as practical.
Installing (AC Power):
1. Turn OFF the power to all equipment that will be plugged into the
unit.
2. Make sure that the ON/OFF switch is in the OFF position. Plug the
unit into the wall outlet and then turn it ON.
3. Verify that the “Wiring” LED is BLUE, indicating that the wall outlet
is properly wired.
4. Plug the equipment to be protected into the POWER360 unit and,
one at a time, turn each piece of connected equipment ON and check
for correct operation.
5. Turn OFF the unit and all connected equipment before connecting
any signal lines.
Installing (Telephone Lines):
(Note: Telephone patch cables not included)
IMPORTANT: Note the position of the IN and OUT jacks on the
POWER360 unit. IN is for the line connection that comes from the
wall or oor jack. OUT is for the line connection to your connected
equipment. The protection circuit will only function if connected
properly. Reversed connections will pass the signal to the connected
equipment but will also prevent the protection circuitry from
working and will invalidate the Panamax Connected Equipment
Protection Policy.
1. Make sure the POWER360 and all connected equipment is turned
OFF.
2. Take the incoming telephone line and plug it into the appropriate
IN jack on the protector. The line should now be connected between
the wall and the POWER360 unit.
3. Plug a telephone line (not included) into the OUT jack and then
plug the other end into the equipment to be protected.
4. Turn On the protector and the connected equipment. Verify that
each piece of connected equipment is receiving power and signal.
Installing (Coaxial Lines):
(Coaxial patch cables not included)
Note the position of the IN and OUT jacks on the POWER360 unit. IN
is for the line connection that comes from the wall or oor jack. OUT
is for the line connection to your connected equipment.
The POWER360 coaxial protection circuits achieve optimum signal
quality from Panamax’s coaxial protectors that have the smallest
signal loss on the market – less than 0.5dB of attenuation from 0MHz
to 2.2GHz. Our coaxial protection has been specically designed to
virtually eliminate signal loss to ensure HD video and high speed
internet performance is not compromised. The clamping level of 75
volts will meet the demands of both cable and satellite voltage while
minimizing exposure to spikes and surges.
NOTE: The CATV/Sat/Antenna protection circuit in these models is
bi-directional and has been designed to work with cable TV systems
that send pay-per-view ordering information to the cable company
over the coaxial line.
Make sure that your equipment is connected to the proper jacks.
When used with diplexers, this protection circuit must be placed
between the diplexer and the Satellite receiver; it will not
protect the diplexer.
1. Make sure the Panamax protector and all connected equipment
is turned OFF.
2. Connect the coaxial cable from the CATV system, antenna, or
Satellite dish to the appropriate LINE connector on the POWER360.
3. Connect a coaxial cable from the EQUIP jack on the protector
to appropriate input jack on your TV, cable modem or Satellite
receiver.
USB Charging Station:
Your POWER360 includes two modular dual-port charging stations.
The unique, patent-pending design of these charging stations allows
them to be removed from the base unit and placed on a nearby desk
or table top for easy access.
The charging station must be tethered to, or plugged directly
into, your base unit to charge. A 6’ tether cable is included for each
charging station. If you require a longer cable, various lengths of
standard USB-to-Micro USB cables are commonly available. Rubber
feet are included for your charging stations. Applied on the bottom
and towards the front of your charging station, they will help keep
your charging stations in place. Each charging station can handle up
to 2.1A capacity, typically enough for 2 mobile devices or 1 tablet. The
USB charging ports are surge-protected.
Wall Mounting:
Your POWER360 may be axed to a wall or other at surface.
1. Determine the mounting location. Hold the POWER360 unit
up against the location and mark drilling positions using the
mounting guides on the sides of the unit. Note: You are marking
the center point where you would like the unit to be mounted.
2. Drive a #6 screw into each drilling position. Leave approximately
1/8” of space between the back of the screw head and the wall.
3. Position the POWER360 over the two screws and slide down to
lock into place.
4. Using the above procedure allows easy removal of the unit
by sliding up to disengage the unit from the screws.
Troubleshooting
The CIRCLE OF PROTECTION is not lit, there is no AC power
to my equipment, or my equipment doesn’t turn on.
- Make sure POWER360 is plugged into a working AC outlet.
- Verify the “VOLTAGE” indicator on the CIRCLE OF PROTECTION
is Blue. If Red, the incoming line voltage is either too high
or too low and has been disconnected from your connected
equipment.
- Make sure the switch/circuit breaker is in the ON position.
- If you still have no power, POWER360 may be damaged.
Contact Panamax Tech Support.
My mobile device is not charging.
- Some devices may be incompatible with this USB charging
port. Although the device may report that it is not charging,
it is most likely to be charging at a lower (0.5 Amp) current.
- When charging two devices it is possible that that USB
charging circuitry may be overloaded. Disconnect one of the
devices.
- Make sure the tether cable is connected between the
charging station and base unit, or the charging station is
completely plugged into the base unit.
There is no audio or video from my cable box and/or my
cable modem is not connecting.
- Check the coaxial connections, making sure they are correctly
and securely installed.
- Try a dierent coaxial cable.
- Bypass the coaxial connectors. If your picture returns, the
protector is damaged. Contact Panamax (website or Tech
Support Department) for replacement.
- If you still have no picture, a problem with your cable
provider’s signal may exist.
(Note: Coaxial patch cables not included)
My telephone, DSL modem or fax machine has AC power
but still does not work.
- Check to see if your connected equipment is receiving a dial
tone.
- Try a dierent telephone cable, or try the equipment with a
dierent telephone jack.
- Bypass the telephone connectors. If your dial tone returns,
the protector is damaged. Contact Panamax (website or Tech
Support Department) for replacement.
- If you still have no dial tone, a problem with the phone
company’s lines may exist.
The Panamax circuit breaker disconnects AC power from
the connected equipment.
- You have exceeded the ampere rating for your surge
protector. As a temporary x, disconnect one or more pieces
of equipment. Ask your Panamax dealer about additional
Panamax protectors that may be required.
PANAMAX TECH SUPPORT: 1-800-472-5555
www.panamax.com/POWER360
English
Warranty and Connected Equipment Policy Information
CAUTION!
All Panamax Warranties and Connected Equipment Policies are valid only in the United States and Canada.
CAUTION!
Audio/Video, computer and/or telephone system installations can be very complex systems, consisting of many interconnected components.
Due to the nature of electricity and surges, a single protector may not be able to completely protect complex installations. In those cases, a systematic approach using multiple protectors must be employed. Systematic protection
requires professional design. AC power, satellite cables, CATV cables, telephone/network lines, signal lines or any other electrical conductors, entering the system that do not pass through this surge protector may invalidate the
Panamax Connected Equipment Protection Policy. For additional information on how to protect your system, please contact Panamax before connecting your equipment to the surge protector.
CAUTION! WARRANTY LIMITATION FOR INTERNET PURCHASERS
Panamax products purchased through the Internet do not carry a valid Product Warranty or Connected Equipment Protection Policy unless purchased from an Authorized Panamax Internet Dealer and the original factory serial
numbers are intact (they must not have been removed, defaced or replaced in any way). Purchasing from an Authorized Panamax Internet Dealer insures that the product was intended for consumer use, has passed all quality
inspections and is safe. Buying through auction sites or unauthorized dealers may result in the purchase of salvaged, failed and/or products not intended for use in the US. In addition, Authorized Panamax Internet dealers have
demonstrated sucient expertise to insure warranty compliant installations. For a list of Authorized Panamax Internet Dealers go to www.panamax.com. If you have any questions regarding these requirements, please contact
Panamax Tech Support.
Product Upgrade Program
If your Panamax power conditioner sacrices itself
while protecting your connected equipment, you
have an option to upgrade to the latest technology.
Please go to our web site www.panamax.com or
contact Panamax Tech Support at 800-472-5555 for
details.
Panamax Surge Protector Lifetime Limited
Product Warranty
Panamax warrants to the purchaser of any standard
Panamax surge protector that the surge protector
shall be free of defects in design, material, or
workmanship, and Panamax will repair or replace
any defective unit. For product replacement see
“NOTIFICATION” (3).
Panamax Surge Protector Limited
Connected Equipment Protection Policy
It is the policy of Panamax that it will, at its election,
either replace, pay to replace at fair market value, or
pay to repair, up to the dollar amount specied below,
equipment that is damaged by an AC power, cable,
telephone, or lightning surge while connected to a
properly installed Panamax power conditioner. To be
eligible for compensation, repair and or replacement,
the power conditioner must shows signs of surge
damage or that it is operating outside of design
specications, relative to its surge protection
capability, and under all of the circumstances failed
to protect your connected equipment.
$500,000 CONNECTED EQUIPMENT POLICY
THE CONNECTED EQUIPMENT POLICY IS
SUBJECT TO THE FOLLOWING CONDITIONS
AND LIMITATIONS
1. ORIGINAL OWNERSHIP REQUIREMENT:
Panamax’s connected equipment policy extends to
the original purchaser of the Panamax product only
and is non-transferable. Original purchase receipts
must accompany any product return or claim for
connected equipment damage.
2. PROPER INSTALLATION:
Panamax AC protectors must be directly plugged
into a properly grounded 3-wire AC outlet. Extension
cords*, non-grounded two prong adapters, or other
non-Panamax surge products must not be used.
Building wiring and other connections to protected
equipment must conform to applicable codes (NEC
or CEC). No other ground wires or ground connections
may be used. All wires (including, e.g., AC power
lines, telephone lines, signal/data lines, coaxial
cable, antenna lead-ins) leading into the protected
equipment must rst pass through a single Panamax
protector designed for the particular application. The
protector and the equipment to be protected must be
indoors in a dry location, and in the same building.
Panamax installation instructions and diagrams must
be followed
3. NOTIFICATION:
You must notify Panamax within ten days of any
event precipitating request for product replacement
or payment for connected equipment damage.
A return authorization (RA) number must rst
be obtained from the Panamax Tech Support
Department at www.panamax.com** before
returning the protector Panamax. At this time,
you must notify Panamax if you believe you have a
claim for damaged connected equipment. Once you
obtain an RA number, please mark the number on the
bottom of the unit and pack it in a shipping carton/
box with enough packing material to protect it during
transit. The RA number must also be clearly marked
on the outside of the carton. Ship the unit Panamax.
Please note that you are responsible for any and all
charges related to shipping the unit to Panamax. If
connected equipment damage was indicated on your
RA request, Panamax will mail you claim kit to be
completed and returned within 30 days. A connection
diagram of your system will be required as part of
the claim kit. Be sure to note its conguration before
disconnecting your equipment.
4. DETERMINATION OF FAILURE:
Panamax will evaluate the protector for surge
damage. The Panamax protector must show signs of
surge damage or must be performing outside (>10%)
of design specications relative to its surge protection
capability. Opening the enclosure, tampering with,
or modifying the unit in any way shall be grounds
for an automatic denial your request for payment.
Panamax, after evaluating all information provided,
will determine whether or not your request is eligible
for payment. If the surge protector shows no signs
of AC power or signal line surge damage and is
working within design specications, Panamax will
return the unit to you with a letter explaining the
test results and notifying you of the rejection your
claim. Exceptions: If a dealer or installer replaces
the protector for the customer, replacement will be
returned to the dealer installer; or if the protector
is a pre-1996 model, it will be replaced; or, for a
Canadian customer, the protector will be replaced.
Panamax reserves the right to inspect the damaged
connected equipment, parts, or circuit boards. Please
note that you are responsible for any and all charges
related to shipping the damaged equipment to
Panamax. Panamax also reserves the right to inspect
the customer’s facility. Damaged equipment deemed
uneconomical to repair must remain available for
inspection by Panamax until the claim is nalized.
5. REQUEST PAYMENTS:
Once Panamax has determined that you are entitled
to compensation, Panamax will, at its election, either
pay you the present fair market value of the damaged
equipment, or pay for the cost of the repair, or send
you replacement equipment, or pay the equivalence
of replacement equipment.
6. OTHER INSURANCE/WARRANTIES:
This coverage is secondary to any existing
manufacturer’s warranty, implied or expressed, or
any insurance and/or service contract that may cover
the loss.
7. EXCLUSIONS:
THE PANAMAX CONNECTED EQUIPMENT
PROTECTION POLICY DOES NOT APPLY TO:
Service charges, installation costs, reinstallation
costs; setup cost; diagnostic charges; periodic
checkups; routine maintenance; loss of use of
the product; costs or expenses arising out of
reprogramming or loss of programming and/or data;
shipping charges or fees; service calls; loss or damage
occasioned by re, theft, ood, wind, accident, abuse
or misuse, and products subject to manufacturer’s
recall or similar event.
8. DISPUTE RESOLUTION:
Any controversy or claim arising out of or relating to
Panamax’s Connected Equipment Protection Policy,
or the alleged breach thereof, shall be settled by
arbitration administered by the American Arbitration
Association under its Commercial Arbitration Rules.
You may le for arbitration at any AAA location in
the United States upon the payment of the applicable
ling fee. The arbitration will be conducted before
a single arbitrator, and will be limited solely to the
dispute or controversy between you and Panamax.
The arbitration shall be held in any mutually
agreed upon location in person, by telephone, or
online. Any decision rendered in such arbitration
proceedings will be nal and binding on each of
the parties, and judgment may be entered thereon
in a court of competent jurisdiction. The arbitrator
shall not award either party special, exemplary,
consequential, punitive, incidental or indirect
damages, or attorney’s fees. The parties will share
the costs of arbitration (including the arbitrator’s
fees, if any) in the proportion that the nal award
bears to the amount of the initial claim.
9. GENERAL:
If you have any questions regarding the product
warranty or the connected equipment protection
policy, please contact the Panamax Tech Support
Department at www.panamax.com. The Limited
Product Warranty and Connected Equipment Policy
herein supersede all previous warranties and/or
Connected Equipment repair/replacement policies.
THE LIMITED PRODUCT WARRANTY IS THE ONLY
WARRANTY PROVIDED WITH THIS PANAMAX
PRODUCT AND ANY OTHER IMPLIED OR
EXPRESSED WARRANTIES ARE NON-EXISTENT.
This warranty may not be modied except in writing,
signed by an ocer of the Panamax Corporation.
* The use of a Panamax extension cord or equivalent
(UL or CSA listed, minimum 14AWG, 3-wire grounded)
will not invalidate the warranty.
** Forms are available on the Panamax web site for
requesting RAs and opening a claim for connected
equipment damage.
PROTECTED
PROTEGIDA
PROTÉGÉ
VOLTAGE
TENSIÓN
TENSION
WIRING
CABLEADO
CÂBLAGE
TM
Circle of Protection
PANAMAX TECH SUPPORT: 1-800-472-5555
www.panamax.com/POWER360
1.
2. 3.
©2014 Core Brands, LLC. All rights reserved. Panamax® and POWER360
TM
are
registered trademarks of Core Brands, LLC. Designed and Engineered in the USA.
Manufactured to Panamax quality specications in China.
P/N: 10002440 Rev-A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Panamax P360-8 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI