Features
Wiring
Environmental limitations
Cautions
Settings and connections
1. Output Current Level Settings
‧
‧
‧
‧
‧
‧
‧
180~295VAC input only
Built-in active PFC
Output current level selectable by DIP switch
Built-in DALI interface and push dimming function (DA version)
Built-in 0~10Vdc a nd PWM signal dimming function (Non-DA version)
Power supply synchronization function up to 10 units
Temperature compensation function by external NTC
‧
‧
‧
‧
‧
‧
‧
Clas s po wer un it, ungrounded
Buil t-in 12V/50mA auxiliary output
Full plastic case enclos ed
No load power consumption <1W (1.2W for DA version)
Protection s: Short circuit / Over voltage / Over temperature
3 year warranty
Suit able for intell igent LED lighting
Ⅱ
‧
‧
‧
‧
Hous ing with cabl e clamp for re mote installation
Use wires with an adequate cro ss-section (see 5)
Use suitable mounting to ols to do the wiring and mounting (see 5)
MCB circuit breaker) with an adequate current rating to protect the lighting system (see 6)
Use a (miniature
‧
‧
‧
Maximum ambient temperature must not exceed 60
Always allow adequate ventilation clearances, 50mm, aro und the unit in use to prevent it from overheating
Only install the unit in interior environments
℃
‧
‧
This unit must be installed by a qualified electrician
This unit is not suitable for applications that DC/DC converters are connected befor e LED lamps
The LCM can prov ide various output currents by se tting the DIP switch. The settings of the DIP switch are shown in the tables below.
LCM-40(DA ) LCM-60(DA)
Note : 1.Fac tory d efault setting is 700mA.
2.Out put voltag e a nd ou tp ut wa ttage must not exc eed th e rate d val ues.
Voltage
ran ge
Voltage
ran ge
1 12 23 34 45 56 6
Sel ectabl e
Current
Sel ectabl e
Current
2-100V 2-90V- -- - ----- ---- -- - ----- - --- -- - ----- ---
--- ---- -- ------ ---- -- - ----- ---
- -- - ----- ---
--- ---
- -- - --
- -- - --
- -- - --
--- ---
O N O N
O N O NON ON
O N O NON ONO N O NON O N
O N ONON ONO N ONON ONON ON
O N ONON ONO N O NON ONON O NON ON
350mA 50 0mA
2-80V 2-90V50 0mA 60 0mA
2-67V 2-86V60 0mA 70 0mA*
2-57V 2-67V70 0mA* 90 0mA
2-4 5V 2-57V90 0mA 10 50mA
2-4 0V 2-42V10 50mA 14 00mA
LCM-40(DA), LCM-60(DA) installation manual
ON
6 5 4 3 2 1
-Vo
+Vo
SY N.
+
-NT C
+DI M
-DI M
+NT C
-FAN
+FAN
+
DA-
DA+
PUS H
AC / N
AC / L
Terminal blocks assignment for LCM
2. Connection of LED Lamps
Press down the "push bu tton" by a slo tted screw driver to insert or rem ove the cable .
Vo-
Vo+
AC/N
AC/L
NEU TRAL (Blue o r whit e)
LIVE (Br ow n or bl ack )
http: //www.meanwell.c om
123.5mm 23mm