ETC
®
Installation Guide
Unison Echo
®
Wall Mount Station Power Supply
Wall Mount Station Power Supply Page 1 of 3 Electronic Theatre Controls, Inc.
Corporate Headquarters
3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA
Tel +608 831 4116
Fax +608 836 1736
London, UK
Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK
Tel +44 (0)20 8896 1000
Fax +44 (0)20 8896 2000
Rome, IT
Via Pieve Torina, 48, 00156 Rome, Italy
Tel +39 (06) 32 111 683
Fax +44 (0) 20 8752 8486
Holzkirchen, DE
Ohmstrasse 3, 83607 Holzkirchen, Germany
Tel +49 (80 24) 47 00-0
Fax +49 (80 24) 47 00-3 00
Hong Kong
Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong
Tel +852 2799 1220
Fax +852 2799 9325
Service:
(UK) service@etceurope.com
(DE) techserv-hoki@etcconnect.com
Web:
www.etcconnect.com
Copyright © 2014 ETC. All Rights Reserved.
Product information and specifications subject to change.
7186M2100
Rev A
Released 2014-06
ETC intends this document to be provided in its entirety.
Overview
Wall Mount Enclosure Installation
Mount the Unit to the Wall
Step 1: Remove the front cover of the unit to
reveal the four mounting keyholes
from inside the unit.
Step 2: Align the unit to the wall and mark the
mounting keyholes. Alternatively, use
the measured keyhole dimensions
located in the graphic (right) to mark
the hole locations for the mounting
hardware.
Step 3: Drill the holes and install the mounting
hardware.
• Mounting hardware is not
supplied.
• Expose at least 1” (25mm) of
threads for mounting the unit.
Step 4: Attach the unit to the mounting
hardware, where the back side of the
unit is flush to the wall, then tighten the
mounting hardware.
Step 5: Insert a screw into the provided wall
anchor point, located between the left
side mounting keyholes of the unit. Populating this hole with a screw provides additional
security that the unit will not fall from the wall during a seismic condition.
The Echo Wall Mount Station Power Supply (E-SPM-WM) is
designed for use with the Echo control system to supply power
for up to 16 Echo control stations on the topology-free Echo
control network.
Note:
If you are using Cat5 (or Cat5e) wiring, an
external Echo Cat5 Termination Box (is
required. Contact ETC for ordering details.
Control wiring instructions between the
termination box and this Wall Mount Station
Power Supply will be provided with the Cat5
termination installation instructions.
10.5”
267mm
14”
356mm
insert seismic
condition screw
here
11.5”
292mm
8.7”
221mm
3.15” deep
80mm
as viewed from the back panel