Installation Instructions
Specications RET1000MD
Operating Voltage 230Vac 50/60Hz
Output Volt free
Setting temp. range 5-30°C
Operating temp. range 0-45°C
Switch rating 3A (1) at 230Vac
Switch type 1 x SPDT Type 1B
IP rating IP20
On/o control Yes
Chrono-proportional control Yes
Delayed start Yes
Construction EN 60730-2-9
Control pollution situation Degree 2
Rated impulse voltage 2.5kV
Ball pressure test 75°C
Dimensions (mm) H84 x W84 x D37
Software Classication A
RET1000 MD
4
GB
Mounting
Fix at a height of 1.5m
approx from the oor,
away from draughts
or heat sources such
as radiators, open res
or direct sunlight.
Please Note:
This product should only be installed by a qualied electrician or
competent heating installer and should be in accordance with the
current edition of the IEEE wiring regulations.
Danfoss Heating
5
GB
Mounting (continued)
P
O
RET1000 MD
6
GB
Wiring
ELECTRONICS
N
L
N
L
1
2
3
COM
ON
OFF
230Vac
RET1000MD
Note: For RET1000 MD live supply is from the Time Control output.
Danfoss Heating
7
GB
DIL switch settings
Slide the DIL switches
to the settings required.
ON/OFF - boiler switches ON when below set temperature and OFF
when above.
CHRONO -
energy saving feature which res the boiler at regular
intervals to maintain a set temperature, achieving a constant
ambient environment for the user.
o
use 6 Cycles for radiator systems
o
use 3 Cycles for underoor heating
RET1000 MD
8
GB
DIL switch settings (continued)
1
2
3
4
CHRONO
6 CYCLES
3 CYCLES
DELAYED START ON
ON/OFF
3/12 CYCLES
12 CYCLES
DELAYED START OFF
DELAYED START -
energy saving feature which automatically
delays the heating start time, depending on how close to
set-point the ambient room temperature already is (see chart
opposite). For example during milder weather the heating start
time can be delayed to avoid wasting fuel by bringing rooms
up to temperature earlier than necessary.
Delayed start only operates when switched from a timer
control.
Danfoss Heating
9
GB
DIL switch settings (continued)
Time delay after time control
switch on, minutes
Temperature below thermostat setting, ⁰C
RET1000 MD
10
GB
Limiting - allowing the user to alter the temperature within
a predened range, which is less than the full range of the
product (i.e. between 18-22°).
Limiting
COL D
HOT
20
30
10
Danfoss Heating
11
GB
Part No 45044v01 04/15
Danfoss Ltd
Ampthill Road
Bedford MK42 9ER
Tel: 01234 364621
Fax: 01234 219705
Website: www.heating.danfoss.co.uk
VIJTE102
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Danfoss 087N645400 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI