Danfoss RET1000 Installation guide

Type
Installation guide

Danfoss RET1000 is a device designed to help you control the temperature in your home. It features an electronic dial setting thermostat, allowing you to set the desired temperature with precision. The device can operate in two modes: ON/OFF and chrono-proportional control. In ON/OFF mode, the boiler switches on when the temperature drops below the set value and switches off when the temperature rises above it. In chrono-proportional control mode, the boiler fires at regular intervals to maintain a constant ambient temperature, providing energy savings.

Danfoss RET1000 is a device designed to help you control the temperature in your home. It features an electronic dial setting thermostat, allowing you to set the desired temperature with precision. The device can operate in two modes: ON/OFF and chrono-proportional control. In ON/OFF mode, the boiler switches on when the temperature drops below the set value and switches off when the temperature rises above it. In chrono-proportional control mode, the boiler fires at regular intervals to maintain a constant ambient temperature, providing energy savings.

MAKING MODERN LIVING POSSIBLE
RET1000 B/M/MS
Electronic dial setting thermostat
Installation Guide
Danfoss Heating
RET1000
2
For a large print version of these instructions
please call Marketing on 0845 121 7400.
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other
printed material. All trademarks in this material are property of the respective companies.
Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss Heating
3
GB
Installation Instructions
Specifi cations RET1000MS RET1000M RET1000B
Operating Voltage 230Vac ±15%, 50/60Hz
2.5 - 3 VDC
(2xAA
batteries)
Output 230Vac Volt free
Setting temp. range 5-30°C
Operating temp. range 0-45°C
Switch rating 3A (1) at 230Vac
Switch type 1 x SPDT Type 1B
Battery lifetime N/A Min. 2 years
IP rating IP20
On/off control Yes
Chrono-proportional control Yes
Construction EN 60730-2-9
Control pollution situation Degree 2
Rated impulse voltage 2.5kV
Ball pressure test 75°C
Dimensions (mm) H84 x W84 x D37
Software Classifi cation A
RET1000
4
GB
Mounting
Fix at a height of 1.5m
approx from the fl oor,
away from draughts
or heat sources such
as radiators, open fi res
or direct sunlight.
Please Note:
This product should only be installed by a qualifi ed electrician or
competent heating installer and should be in accordance with the
current edition of the IEEE wiring regulations.
Danfoss Heating
5
GB
Wiring
1
2
3
COM
ON
OFF
RET1000B
RET1000
6
GB
Wiring
ELECTRONICS
N
L
N
L
1
2
3
COM
ON
OFF
230Vac
RET1000M
Danfoss Heating
7
GB
Wiring
ELECTRONICS
N
L
N
L
2
3
ON
OFF
230Vac
RET1000MS
RET1000
8
GB
DIL switch settings
Slide the DIL switches
to the settings required.
ON/OFF - boiler switches ON when below set temperature and OFF
when above.
CHRONO -
energy saving feature which fi res the boiler at regular
intervals to maintain a set temperature, achieving a constant
ambient environment for the user.
use 6 Cycles for radiator systems
use 3 Cycles for under oor heating
1
2
3
4
CHRONO
6 CYCLES
3 CYCLES
NOT USED
ON/OFF
3/12 CYCLES
12 CYCLES
NOT USED
Danfoss Heating
9
GB
Mounting (continued)
RET1000
10
GB
Limiting - allowing the user to alter the temperature within
a predefi ned range, which is less than the full range of the
product (i.e. between 18-22°).
Limiting
COLD
HOT
20
30
10
Danfoss Heating
11
GB
Part No 45026v01 01/14
Danfoss Ltd
Ampthill Road
Bedford MK42 9ER
Tel: 01234 364621
Fax: 01234 219705
Email: ukheating@danfoss.com
Website: www.heating.danfoss.co.uk
VIRKQ102
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Danfoss RET1000 Installation guide

Type
Installation guide

Danfoss RET1000 is a device designed to help you control the temperature in your home. It features an electronic dial setting thermostat, allowing you to set the desired temperature with precision. The device can operate in two modes: ON/OFF and chrono-proportional control. In ON/OFF mode, the boiler switches on when the temperature drops below the set value and switches off when the temperature rises above it. In chrono-proportional control mode, the boiler fires at regular intervals to maintain a constant ambient temperature, providing energy savings.

Ask a question and I''ll find the answer in the document