DIAGNOSTIC
CODES
CODE
STATUS
DISPLAY
ERROR
SUGGESTED
ACTION
UGHT
Freeze Protection
Engaged,
The
room
temperature
No
Action
required, This setting will disengage when
the
FP
measured by the wireless remote thermostat
or
indoor ambient
Y N
room
temperature rises above 43'F,
thermistor active sensor falls
below
40'F,
Fd
Front Desk swlch
is
closed. All outputs are swlched
off,
Y
Open front desk switch to allow occupant unit operation,
Eo
Un-Configured Service Board -
Y
Y
Enter Configuration
Menu
and
set "C3" to
"c"
All operation held awaling configuration
forcoolers with electric heat or
"H"
for heat pumps.
EH
Emeregency Hydronic
Engaged,
The
EHH
switch is closed.
Y
N
Open
front emergency hydroni: switch to allow
Compressor is switched off,
unit operation,
LS
load
Shedding Engaged.
The
lS
switch is closed,
Y
N
Open bad shedding switch
Com
pressor and Electric heat is switched
off.
to allow occupant unit operation.
On
Control is configured
to
respond to a wired thermostat Y N
No action If a wired thermostat
is
being
used,
Otherwise, see Configuration Settings,
Indoor Ambient Thermistor reeds outside the
range -20"F to 200°F
& the wireless thermostat is not
F1
communi:ating
to
the Lrlit control or
Y Y
Replace black Indoor Ambient Thermistor or
Wireless Remote Thermostat,
Indoor Ambient Thermistor (IAT)
wlhout
a wireless remote
thermostat reads outsile the range
-zooF
to
ZOO°F,
F2
Wireless
Rem
ote
Thermostat failure N
N Replace Wireless Thermostat.
F3
Indoor
Am
bient Thermistor reeds
Y N
Replace black Indoor Ambient Thermistor.
outsile the range -20"F to 200°F
F4
Indoor
Col
Thermistor either above
N
Y Replace
Red
Indoor Coil Thermistor .
or
below operating tolerances,
F5
Wireless Thermostat failure, N Y
Attempt to rebind Wireless Thermostat
or
Replace Wireless Thermostat
F6
Indoor Discharge Thermistor either above
N Y
Replace Yellow Indoor
or
below operating tolerances.
Discharge Thermistor,
Fb
Low
Remote Battery Warning. N Y
Replace Batteries in Wireless Devices,
H1
High Voitage Protection engaged,
N
Check for incoming power at correct voltage.
Power supply voltage
is
to
high.
br
Brown Out Protection engaged.
N N
Check for Incoming power
at
correct voltage.
Power was lost or voltage
is
low.
L6
Discharge Air Too
Hot.
N Y
Clean Filter or Remove Air Blockage,
LC
Outdoor Coil Thermistor temperature high. N Y
Clean Condenser Coils, Check
Fan
for
faull Code will reset after cleaning,
C2
Indoor Air Recirculation, Large
dela
between thermostat
and
N
Y
Clean
Filter or Remove Air Blockage or Close
return,
Vent Door
or
Improve indoor to outdoor seal.
C5
Outdoor Coil temperature too high for outdoor ambient
N Y Check for Bbcked Outdoor Air or
Clean
Coil.
temperature.
Clean
filer. Check for fan and blower operatkm.
C3
Indoor
Col
is freezing
up,
N Y
Check for Refrigerant loss
or
Restricted
capiDary
tube,
Clean filter, Check for fan
and
blower operation.
C4
Indoor con froze up, N
Y Check for Refrigerant loss
or
Restricted capillary tube,
C6
Poor Unit Performance.
N
Y
Check
for
bbwer motor. compressor,
or
electri:
heat
operation.
17