Amana DRY 093Gxxx series XXX User manual

Type
User manual

This manual is also suitable for

SS-DPTAC www.amana-ptac.com 2/13
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.
Supersedes 12/12
Packaged Terminal air condiTioner
with
35% More DehuMiDification
than the aMana® branD
DigiSMart™ Ptac
Features
• Superior35%Dehumidication — Amana® brand ActivDRY
PTACs remove up to 35% more water from the air than our
standard PTAC – as much as 2.8 pints per hour, depending
on the model
• SeacoastCorrosion-ResistantCoil — Our optional Seacoast
corrosion-resistant coil is available by order for locations
where coil corrosion is a problem
• Energy Efciency — EER of up to 11.2 to keep energy
consumption to a minimum
• On-board Energy Management System — Amana® brand
units are equipped with EMS technology to better control
room temperature and save energy dollars
• DigiSmart™ ControlBoard — Ready for wireless or wired
operation
• Programmable Set-back Program — Settings allow auto-
matic temperature setback when unit is idle
• DigiSmart™ Suite of Peripherals — Remote occupancy
sensor, remote thermostat, RF antennas, and RF platform
controller provide everything you need to reduce energy
costs by 35%
First-Year Warranty: Parts & Labor
Second through Fifth Year: Parts & Labor on certain sealed system components
Second through Fifth Year: on certain functional parts only
* Complete warranty details available at www.amana-ptac.com.
SS-DRYPTAC www.amana-ptac.com 3
2 www.amana-ptac.com SS-DRYPTAC
P
roduct
S
PecificationS
P
roduct
S
PecificationS
brings together our best PTAC ever with our best Energy Management Software and now integration with Property
Management and Front Desk Management Software. Reduce PTAC energy consumption by 35% OR MORE* through the power of
the in-unit Energy Management System, programmable temperature set-back and limits combined. Reduce PTAC maintenance cost
through our automated maintenance notication system. Improved maintenance sustains energy efciency (EER) and prolongs
PTAC life, keeping equipment running at its designed efciency level and room guests more comfortable.
The amana Brand digiSmarT SoluTion
in-room: “Self-inSTallaBle” WireleSS PeriPheralS
The DigiSmart Occupancy Sensor completes the in-room equipment. This infrared sensor can
determine if the room is occupied or empty, and when empty signals the PTAC to adjust the
temperature to save energy based on programmable setbacks.
The DigiSmart Wireless Remote Thermostat can mount on the wall anywhere in the guest room.
Battery powered and with its own wireless ability to communicate with the PTAC to maintain
room temperature. Best of all, no wires to run. The PTAC and Thermostat connect at the press of
a button and are permanently linked. The thermostat and PTAC work in-sync to display accurate
temperature.
The DigiSmart Wireless Antenna installs inside the PTAC with a snap-in connector. Installing the antenna allows the PTAC to
communicate wirelessly with other devices in the room and to the DigiSmart network.
> 45,000+ rooms have had wireless installations since 2005
> Total wireless devices deployed to date: 120,000+
The Amana brand DigiSmart PTAC with antenna, combined with the self-installable, wireless Thermostat and Occupancy Sensor
give the property owner complete control over the equipment settings and can reduce PTAC energy usage by 35% OR MORE.*
SS-DRYPTAC www.amana-ptac.com 3
2 www.amana-ptac.com SS-DRYPTAC
P
roduct
S
PecificationS
P
roduct
S
PecificationS
WeB-BaSed, real-Time moniToring
amana® Brand digiSmarTconTroller:
All of the PTACs in the building can be managed through a single interface on a PC.
FEATURES INCLUDE: Full unit details for every PTAC, visible from the front desk or home ofce, automatic emails for PTAC
maintenance, ability to change all settings on the unit, and enhanced diagnostics. Monitor up to 170 PTACs, WIRELESSLY, with one
controller. Additional controllers can expand the network for additional rooms/properties.
> System Verication
> Global Setbacks
> EMS Conguration
> Site Statistics
> Battery Notices
> Email Reporting
> Unit Health
> Unit Code Alerts
Temp Limiting – Each PTAC
can be congured with a heat-
ing and cooling temperature
set-point limit.
Setbacks – Once a room is declared unoccupied by the occupancy sensor, the PTAC progresses through three different temperature
setbacks, congured as three degree and time pairs (An example conguration is listed below).
1st: 2°, 30 mins – Setback the temp 2 degrees after 30 minutes
2nd: 4°, 1 hr – Setback the temp 2 more degrees after 30 more minutes
3rd: 8°, 3 hrs – Setback the temp 4 more degrees after 2 more hours
Unrented Set-Points – By integrating with your property's Front Desk System, the PTACs will adjust to specic set-points when no
longer identied as rented in the system.
SS-DRYPTAC www.amana-ptac.com 5
4 www.amana-ptac.com SS-DRYPTAC
P
roduct
S
PecificationS
P
roduct
S
PecificationS
nomenclaTure
BasicModelType Engineering
  
CoolingCapacity FeaturesCode
 



RatedVoltage 
 
 

DesignSeries 
 

HeaterSize 
   
  
  
DRY
09
3
G
35
AXXX


AA
1,2,3
4
5
6
7,8,9
10,11,12,13
14
SS-DRYPTAC www.amana-ptac.com 5
4 www.amana-ptac.com SS-DRYPTAC
P
roduct
S
PecificationS
P
roduct
S
PecificationS
ProducT SPecificaTionS

¹ MCA(MinimumCircuitAmpacity)rangsconformtotheNaonalElectricCode;however,localcodesshouldapply.
² Minimumvoltageon230/208-voltmodelsis197volts;maximumis253volts.
³ Overcurrentproteconforallunitswithoutelectricheatersis15amps.SeeheaterperformancefortotalMCA.
⁴ Heangcapacityandeciencybasedonunitoperaonwithoutcondensatepump;unitautomacallyswitchestoelectricheatatapproximately24°F
outdoorambient.
⁵ Totalwasfor12,000BTU/hmodels.
⁶ Specifytwo-digitheaterkWsizetocompletemodelnumber.
⁷ Totalampsfor12,000BTU/hmodels.
⁸ R-410Arefrigerantusedinallsystems.
⁹ AllunitsmeetorexceedASHRAE90.1standards.
¹⁰ Allunitslessthan250voltshaveaLeakCurrentDetectorInterrupter(LCDI)powercordandmeetUL484standards.
¹¹ RefertoelectricheatperformancedatafortotalMCAandrecommendedovercurrentprotecon.AmpsandWasnotaonreferstocompressoronly.
DRY
093G***XXX
DRY
094G***XXX
Voltage 230/208 265

Capacity(BTU/h) 8,800/8,600 8,800
Amps 4.6/4.7 4.3
Was 785/770 785
EER 11.2/11.2 11.2
CFM(Cool/
WetCoil)
High 290 290
Low 264 264
Dehumidicaon* 2.8 2.8

Min.CircuitAmps 5.5 5.0
Was
BTU/h
CFM(DryCoil) High 310 310
Low 282 282
FreshAir,CFM(FanOnly) 65* 65*
NetWeight(lbs.) 98 102
ShipWeight(lbs.) 113 117
*(Pints/Hr.@High/LowSpeed)
^ Approximately95CFMwithoponalpowerventkit.ActualventCFMperformancewill
varyduetoapplicaonandinstallaoncondions.
SS-DRYPTAC www.amana-ptac.com 7
6 www.amana-ptac.com SS-DRYPTAC
P
roduct
S
PecificationS
P
roduct
S
PecificationS
elecTric heaT Performance daTa

















 
230/208V 2.5/2.0 1 8,500 6,800 2,650/2,140 11.5/10.2 14.2 15 6-15P
230/208V 3.5/2.9 1 12,000 9,900 3,650/3,040 15.8/14.5 19.6 20 6-20P

¹ MinimumbranchcircuitampacityrangsconformtotheNaonalElectricCode;however,localcodesshouldapply.
² Minimumvoltageon230/208-voltmodelsis197volts;maximumis253volts.
³ Overcurrentproteconforallunitswithoutelectricheatersis15amps.
4
Heangcapacityandeciencybasedonunitoperaonwithoutcondensatepump;unitautomacallyswitchestoelectricheatatapproximately24°F
outdoorambient.
5
Totalwasfor12,000BTU/hmodels;subtract70wasforPT07/09*B**A*
6
Specifytwo-digitheaterkWsizetocompletemodelnumber.
7
Totalampsfor12,000BTU/hmodels;subtract0.2ampsforPT07/09*B*A*.
8
R-410Arefrigerantusedinallsystems.
9
AllunitsmeetorexceedASHRAE90.1standards.
10
Allunitslessthan250voltshaveaLeakCurrentDetectorInterrupter(LCDI)powercordandmeetUL484standards.
All units come with factory-installed power cords.
Allunitslessthan250voltscomewithLCDIdevice.
Power recePtacle configuration
NEMA6-30R; 250V receptacle,
used on 230/208V units
G
NEMA7-30R; 277V receptacle,
used on 265V units
G
NEMA6-15R; 250V receptacle,
used on 230/208V units
G
NEMA6-20R; 250V receptacle,
used on 230/208V units
G
W
NEMA7-20R; 277V receptacle,
used on 265V units
G
250V Rating Power Cord Plugs with LCDI Device
NEMA 6 Configuration
Power cord Plugs
15 amp
20 amp
30 amp
PoWer cord configuraTion
conTracT Bid SPecificaTionS
Please visit www.amana-ptac.com to download the contractor bid specications information.
SS-DRYPTAC www.amana-ptac.com 7
6 www.amana-ptac.com SS-DRYPTAC
P
roduct
S
PecificationS
P
roduct
S
PecificationS
uniT WiTh acceSSory Wall Sleeve and SuB-BaSe acceSSory
3 "
1"
1"
6-1/8"
9-9/16"
24 -5 /16"
40"
42"
Location of external drain holes
on bottom flange of Wall Sleeve
3" Clearance
to side walls
Air
Flow
Air
Flow
Air
Flow
Air Discharge Grille
Control
Door



58”LCDICORDSET—230V/208VUNIT*
SS-DRYPTAC www.amana-ptac.com PB
8 www.amana-ptac.com SS-DRYPTAC
P
roduct
S
PecificationS
P
roduct
S
PecificationS
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commitment
to quality products may mean a change in specications without notice. © 2013 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.
FINISHED FLOOR
42 1/4"
16 1/4"
MIN
MAIN STUD
JACK STUDS
HEADER - 4" x 4" OR
DOUBLE 2"x 4" ON EDGE
SUB-FLOOR
CRIPPLE
JACK STUD
ADJUST FRAMING TO
SECURE THIS DIMENSION
framing for acceSSory Wall Sleeve (WS900d)



H = 16¼"
W = 42¼"

Wheninstalledinanopening,theWallSleevemustbehorizontallylevel(side-to-side)andpitchedtotheoutside.(Toensure
unit’smaximumeciency,over-orunder-pitch.)

1. If(PTSB***E)isinstalled,allowminimum3¼”heightclearanceandmaximum5”heightclearancebetweenwallsleeveand
oor;allowminimum2¾”protrusionfromanishedwall.See Note 4 if using hydronic units.
 (DK900D)shippedseparately.Canbemountedeitherrightside,lesideorboomofsleeve.Ifmountedtoboomofsleeve,
allow2”heightclearancefromoortoboomofsleeve.
3. ForULapproval,265VunitsmustuseAmana
®
brand(PTSB***E)orAmana
®
brand(PTPWHWK4).Overcurrent
proteconon265Vunitsmustbebycartridge-stylemedelayfuses,
®


4. If(HWK03orHVK03)isinstalled,mustextendexactly3"intotheroomfromthenishedinteriorwall.Ifusing
theAmana
®
brand(PTSB***E),onlytheminimum3¼”heightclearancebetweenwallsleeveandoorispermissible.Unit
mustalsobeoperatedwitharemote-mountedthermostat.
5. If(MDK02B)isinstalled,allowaminimumof2⅜”intotheroomfromthenishedinteriorwall.
WallSleevemustextendaminimumof¼”beyondoutsidewalltoallowforpropercaulking.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8