Contrive RadioControl-4 User manual

Type
User manual
DECLARATION OF CONFORMITY
Company identification:
Product identification:
We declare on our sole responsibility, that the product described above
is in compliance with the following Directives:
Manufacturer: Contrive, Srl
Via Enrico Fermi 18 24040 Suisio Italy
Brand: Contrive
Equipment name: RadioControl-4
Equipment type: Remote control receiver
99/05/CEE
73/23/CEE
89/336/CEE
92/31/CEE
93/68/CEE
and essential requirement of the following standards:
EN 60950
EN
EN
EN
EN 6
RADIO & TELECOMMUNICATIONS TERMINAL EQUIPMENT Directive
ELECTRICAL EQUIPMENT - Low Voltage Directive
ELECTROMAGNETIC COMPATIBILITY
ELECTROMAGNETIC COMPATIBILITY, AMENDMENT
Directives Amendment (LVD)
Suisio, Italy February 7, 2007
¡
¡
¡
¡
¡
¡
¡
¡
¡
¡
¡
-1:2001
300 220-3:v.1.1.1
301 489-1:v.1.4.1
301 489-3:v.1.4.1
1000-6-1:2001
EN 61000-6-3:2002
52
140
115
Process or appliance can be controlled by means of 4 SPDT
relay contacts. Two contacts are provided with onboard fuse.
It’s suitable to drive an external relay when controlling fluorescent
or discharge lamps and in general inductive or capacitive loads
when power is greater than 35W.
Rated current 8 A
Rated voltage 240 Vac
Max breaking capacity 2000 VA
Minimum contact load 100 mA, 12 V
Cadmium free contacts
Insulation 240/400 V (IEC60664 / VDE0110b - cat. III / a)
Surge voltage coil contacts: 4000V
Dielectric strength coil-contacts 5000V
open contact circuit 1000V
4 x 1.5 mm (AWG16) screw connector
Fuse protection 4A/250V 5x20mm (out2 / out3)
RMS
RMS
RMS
2
CONTRIVE RESERVES THE RIGHT TO MODIFY THE CHARACTERISTICS STATED
IN THIS INSTRUCTION MANUAL AT ANY TIME AND WITHOUT PRIOR NOTICE.
© COPYRIGHT 2002...2007 CONTRIVE SRL ITALY. ALL RIGHTS RESERVED.
Each output can be activated also by
means of optionals local push buttons
wired to specific connector.
Normally open push button
Contact voltage < 20 V
Contact current<2mA
5x1mm (AWG18) screw connector
DC
2
A wire, ¼ wave (17 cm) length (included) can be used like
simplified antenna. Connect this wire to terminal 15 and leave
the wire inside the plastic box.
This simplified antenna can be located remotely using a
coaxial cable with its braid stripped over the last 17 cm.
This length is that which has to extend outside the housing if
the latter is metallic.
Any 433 MHz antenna can be used instead of simple wire. Use shielded cable type
RG58 for theantenna connection. Shield must be connected to terminal 16.
CONTRIVE S.R.L.
Via Enrico Fermi 18 I-24040 SUISIO (Bergamo)
Tel. +39 (0)35 4948236 Fax +39 (0)35 4933759
B4001.EN / 0207 www.gsm-control.biz
Power supply connection at terminal 1 and 2.
An automatic switch having at least 3mm contact gap must be
installed on the power supply line.
Power supply: 230 V AC ±20%
Frequency: 50 Hz
Max current consumption: 28 mA
2 x 1.5 mm (AWG16) screw connector
2
This device should be installed only by qualified personnel. Carefully read the
instruction manual inits entirety and keep it safe for future reference.
It is essential to know the information and comply with the instructions given in the
manual to ensurethe fitting is installed, used and serviced correctly andsafely.
OEMs, Engineers and integrators must provide compliance with all applicable
standards. Disconnect power supply and follow all usual safety precautions before
carrying out any operation on the device. This unit is not user serviceable, a faulty
device must beput out of order and sent back for servicing.
This unit is not authorised for use as critical component in life-support devices or
systems unless aspecific written agreement has been given.
No complex softwareor hardware system is perfect.
Bugs are alwayspresent in a system of any size.
In order to prevent danger to life or property, it is the responsibility of the system
designer to incorporate redundant protective mechanism appropriate to the risk
involved.
All units are 100% functionally tested. Specifications are based on characterisation
of tested sampleunits rather than testing over temperature and voltage eachunit.
Contrive disclaims all liability for damage to the fitting or to other property or persons
deriving from installation, use and maintenance that have not been carried out in
conformity with thisinstruction manual, which must always accompanythe fitting.
SAFETY INFORMATION
INPUTS
ANTENNA
PRODUCT DESCRIPTION
r
If the device has been stored in a cold environment, then condensation can
occur. Before starting operations, the device must be absolutely dry.
Thus, an acclimatization period of at least three hours must be observed.
In order to avoid possible damage, we recommend that you only use the
specified accessories.
These have been tested and shown to work well with this unit.
POWER SUPPLY
OUTPUTS
INSTALLATION
The receiver positionis very important for the best operation of thesystem.
Place the receiver far from interference sources such as big magnetic fields or radio
emissions. The installation and the positioning of the antenna is very important as
well. Before to install the antennait is advisableto make some tests on the site.
DISCONNECT POWER SUPPLY AND FOLLOW ALL USUAL SAFETY
PRECAUTIONS BEFORE CARRYING OUT ANY OPERATION ON THE DEVICE
OR CONTROLLED LOADS.
Your RadioControl-4 is the product of advanced engineering, design and
craftmanship and should be treated with care. The suggestion below will help you to
enjoy this productfor many years.
¡
¡
¡
¡
¡
¡
Do not expose the unit to any extreme environment where the temperature or
humidity are outof operating range.
Do not usechemical cleaning agent on the unit.
Do not attemptto disassemble the unit or remove any part orlabel.
There are nouser serviceable parts inside.
Do not exposethe unit to water,rain or spilt beverages. It is not waterproof.
Do not abusethe unit by dropping, knocking orviolenty shaking it.
Rough handling candamage it.
This unit is under your responsibility. Please treat it with care respecting all local
regulations. It is not a toy. Therefore, keep it in a safe place at all times and out of
the reach ofchildren.
1.
2.
3.
4.
5.
6.
7.
TOP COVER SCREW
TOP COVER
ENCLOSURE
PROTECTION SCREEN
CABLE INLETS
SIMPLE WIRE ANTENNA
FITTING SCREWS
CARE AND MAINTENANCE
4001.00.01 RadioControl-4
4001.00.02 RadioControl-TX4
4001.00.03 RadioControl-TX999
AM/ASK 4 CHANNELS RADIO RECEIVER
4 CHANNELS REMOTE CONTROL
MULTI CHANNEL REMOTE CONTROL
USER GUIDE
RadioControl-4
REMOTE 4 OUT RADIO RECEIVER
RadioControl-4 is a superheterodyne receiver operating at the frequency 433,92
MHz. It’s a one-way system, controlling 4 power SPDT relays according to orders
sent by remotecontrols.
The link betweenremote control and receiver is onlyeffective after a learning phase.
Up to 80 different remote key can be associated to local outputs by means of simple
learning sequence.
Outputs can operatein toggle or pulse mode (output activated until keypressed).
The connections aresuitable for use in domestic andindustrial environments.
Receiver type: Superheterodyne
Demodulation: AM/ ASK
Operating frequency: 433,92 MHz
Sensitivity: -115 dBm
Command encoding: Keeloq hopping code
Input impedance: 50 Ohm
Temperature: operating -20 to 70°C
storage and transport –30 to 85°C
Overall dimensions: 140 x 115 x 52 mm.
Weight: 420 g
IP Protection Grade: IP 44 ( IEC 529) properly fittedEN-60529 /
128
104
OUTPUTS TERMINALS .
POWER SUPPLY TERMINALS .
INPUTS TERMINALS .
PUSH BUTTON .
ANTENNA TERMINALS .
MODE SELECTION DIPSWITCHES .
STATUS LEDS .
OUTPUT FUSE .
8
9
10
11
12
13
14
15
RadioControl-4 can store up to 80 different keys in the internal memory. Once the
memory is full,LD3 and LD4will blink.
Trying to store a new key when the memory is full, LD3 and LD4 will blink two times
and the operationis aborted.
To remove all the keys previously stored follow this procedure:
Hold the push-buttonP1 stroked for
2 seconds untilred led LD1will blink,
then release P1.
Stroke again P1 until LD3 and LD4
will blink three times to confirm that
the internal memory has been
completely erased.
To remove a single key previously stored follow this procedure:
Hold the push-buttonP1 stroked for
2 seconds untilred led LD1will blink,
then release P1.
Until LD1 is blinking push on the
RadioControl-TX4 the key previously
stored you want to delete from the
memory.
LD3 and LD4 will blink two times to
confirm the operation.
TX4 LEARNING PROCEDURE
OUTPUT MODE SELECTION
Follow this simplesequence to assign
local outputs tosome keys ofa new
RadioControl-TX4 remote controland
permanently store theassignment into
the RadioControl-4 memory.
Hold the push-button P1 stroked
for 2 seconds until red led LD1 will
blink, then releaseP1.
Until LD1 is blinking push the key on
the RadioControl-TX4 you want to
control output 1. Red led LD1 will turn
off for a while to acknowledge.
Skip this operation if you don’t want to
map a keyto this output.
If you want to store a new key, stroke
the push-button P1, red led LD2 will
blink.
Until LD2 is blinking push the key on
the RadioControl-TX4 you want to
control output 2. Red led LD2 will turn
off for a while to acknowledge.
Skip this operation if you don’t want to
map a keyto this output.
If you want to store a new key, stroke
the push-button P1, red led LD3 will
blink.
Until LD3 is blinking push the key on
the RadioControl-TX4 you want to
control output 3. Red led LD3 will turn
off for a while to acknowledge.
Skip this operation if you don’t want to
map a keyto this output.
If you want to store a new key, stroke
the push-button P1, green led LD4 will
blink.
Until LD4 is blinking push the key
on the RadioControl-TX4 you want to
control output 4. Green led LD4 will
turn off for a while toacknowledge.
Skip this operation if you don’t want to
map a keyto this output.
If you want to store a new key, stroke
the push-button P1,all led willturn on.
Until all leds are on push the key on
the RadioControl-TX4 you want to
use to turn al 4 outputs OFF in a
single touch.
All leds turns off to acknowledge.
Repeat the steps above for all the remote controls you may want to map inside this
RadioControl-4.
Operating mode of each relay can be configured by
means of dipswitches .
To operate in TOGGLE mode, set the switch to ON.
To operate in PULSE mode, set the switchto OFF.
Minimum pulse width:200ms.
While in normal operation the status of each output is
reported by ledindicators LD1 toLD4.
[13]
Follow this simplesequence to assign
local outputs tosome codes ofa
new RadioControl-TX999 remotecontrol
and permanently storethe assignment
into the RadioControl-4memory.
Hold the push-buttonP1 stroked for
2 seconds untilred led LD1will blink,
then release P1.
Until LD1 is blinking, enter
the number to be
assigned to output 1, then
confirm with key #.
Red led LD1 will turn off
for a while, to acknow-
ledge.
In this example output 1 is
linked to code1.
If you want to store a new code, stroke
the push-button P1, the red led LD2
will blink.
Until LD2 is blinking, enter
the number to be
assigned to output 2, then
confirm with key #.
Red led LD2 will turn off
for a while, to acknow-
ledge.
In this example output 2 is
linked to code2.
If you want to store a new code, stroke
the push-button P1, the red led LD3
will blink.
Until LD3 is blinking, enter
the number to be
assigned to output 3, then
confirm with key #.
Red led LD3 will turn off
for a while, to acknow-
ledge.
In this example output 3 is
linked to code3.
If you want to store a new code, stroke
the push-button P1, the green led LD4
will blink.
Until LD3 is blinking, enter
the number to be
assigned to output 4, then
confirm with key #.
Red led LD4 will turn off
for a while, to acknow-
ledge.
In this example output 4 is
linked to code4.
If you want to store a code to be used for single touch turn off of whole 4 outputs,
stroke P1 againand follow theprocedure shown forthe RadioControl-TX4.
In normal operation,to activate thespecific channel enterthe code andconfirm #.
TX999 LEARNING PROCEDURE DELETE A KEY FROM MEMORY MULTI CONTROL
DELETE ALL KEYS FROM MEMORY
WARNINGS
THE INFORMATION CONTAINED IN THIS DOCUMENT ARE SUBJECT TO CHANGE
WITHOUT NOTICE. PRODUCT NAMES, CORPORATE NAMES OR TITLES USED WITHIN
THIS DOCUMENT MAY BE TRADEMARKS OR REGISTERED TRADEMARKS OF OTHER
COMPANIES AND ARE MENTIONED ONLY IN AN EXPLANATORY MANNER TO THE
READERS’ BENEFIT, AND WITHOUT INTENTIONTOINFRINGE.
WHILE EVERY EFFORT HAS BEEN MADE TO MAKE SURE THE INFORMATION IN THIS
DOCUMENT IS CORRECT, CONTRIVE CAN NOT BE LIABLE FOR ANY DAMAGES
WHATSOEVER FOR LOSSRELATING TO THIS DOCUMENT.
WARRANTIES
CONTRIVE GUARANTEES FOR TWO YEARS FROM THE DATE OF MANUFACTURE OF
ITS PRODUCT TO REPLACE, OR, AT ITS OPTION, TO REPAIR ANY PRODUCT OR PART
THEREOF WHICH IS FOUND DEFECTIVE IN MATERIAL OR WORKMANSHIP OR WHICH
OTHERWISE FAILS TO CONFORM TO THEDESCRIPTION OF ITS SALESORDER.
CONTRIVE MAKES NO WARRANTY OF MERCHANTABILITY OR ANY OTHER
WARRANTY EXPRESS OR IMPLIED. IN NO EVENT SHALL CONTRIVE BE LIABLE FOR
CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY NATURE WHICH MAY ARISE IN
CONNECTION WITH SUCH PRODUCTS.
THE WARRANTY DOES NOT APPLY IN CASE OF IMPROPER USE
A typical applications of multiple RadioControl-4 can be the lighting technique
exhibition rooms that are normally structured in box, as shown in the figure
below. Each box can be equipped with a RadioControl-4 to run lighting fixtures
from a single RadioControl-TX999.
To operate without problems RadioControl-4 must be installed with a minimum
clearance of 1 m from any other radio receiver, including RadioControl-4.
RadioControl-4 can be used to control electrical devices and lights where a
traditional installation by wire is impossible.
EMERGENCY CONTROL
ELECTROMAGNETIC POLLUTION AND SCREENS
National standards and common sense recommend to implement local control by
means of push buttons connected to terminal to operate when the remote
control battery is completely discahrged or the remote control is lost. This local
control will behelpful in emergencysituations.
By the way, it’s suitable to store almost two remote control during the first
installation, one ofwich will beheld in adrawer and usedin emergency.
Following International Standards requirements, the frequency assigned to
remote radio controls is 433,92 MHz. Interference can be introduced by some
wireless devices like:
radio controlled burglaralarms
radio controlled PCmouse and keyboards
radio controlled TV or HiFi systems
radio remote controlsfor gates, shutters,vehicles
WalkieTalkies
Some of these devices are used for short periods an the interference will not lead
to a malfunction. For continuous transmitting units it’s better to choose systems
that operates ata different frequency (868 MHz).
A radio scanner can help in finding radio devices or, more simply, test the
RadioControl-4 in theenvironment before toinstall permanently.
Attenuation of radio signal can be introduced when the RadioControl-4 and remote
control are separatedby materials.
Indicative levels ofattenuation for different materials areshown:
[12]
¡
¡
¡
¡
¡
LD1
LD2
LD3
LD4
OUT1
OUT2
OUT3
OUT4
ON
OFF
Wood and Gypsum
10% signal attenuation
Solid or hollow brick
30% signal attenuation
Reinforced concrete
70% signal attenuation
Metallic grills, aluminium panels and similar materials will
introduce a signal attenuation from 90% to 100%.
90% 70% 30%
BOX
OFFICE
BOX6
BOX1
BOX6
BOX2
BOX4
BOX3
Using our RadioControl-TX remote controls the operating range, is
100 meters approx,open air.
WARNING