2 of 3
DocumentNumber:EI216697 09/16/2019
Subject:WaterValveKit
n
Caution
DANGER OF ELECTRICAL SHOCK
Disconnect and lock out all electrical power sourcesbefore
performingserviceormaintenanceonthismachine--except
whenelectricaltestsarebeingperformedbyqualifiedservice
personnel.
n
Caution
AdheretoallNationalandLocalPlumbingandElectrical
SafetyCodes.
n
Caution
Turn “off” incoming electrical service switches when
servicing,installing,orrepairingequipment.
n
Caution
Use caution when handling metal surface edges of all
equipment.
INSTALLATION OF FRONT DRAW TOWER
1. Turn“off”thepowerswitchonthedispensingtower.
2. Removetopcoverandrearcoverpanels.
3. Removewireharnessconnectingthefarleftdispensing
valve(labeled“#1”)totheelectronicportioncontrol
boardandthefront-mountedwaterswitch.
4. Connecttheleftdispensingvalvetotheportioncontrol
boardwiththenewharnessprovidedinthiskit.
5. Assemblethewatervalvetothemountingplatedirectly
behindtheleftdispensingvalve.Use1/2”spacersunder
thevalve.
6. Connectthewatervalvewireharnesstothevalveand
frontmountwaterswitchcommonandnormallyopen
terminals.
7. Inserttheplasticbushingintheholeadjacenttothe
watervalveandroutetheconnectorendofcorddown
throughthebushing.Disconnectone(1)ofthetower
powersupplycordsandreconnectinserieswiththe
watervalvecord.
8. Insertscribedendofthestainlesssteelspouttube
intotheoutletfittingofthewatervalvewiththespout
projectingdownthroughtheholelocatedinthesplash
panelbetweenthefirstandtheseconddispensing
valves.
9. Makeappropriatewatersupplyconnectiontothewater
inlettube.
10.Turnthewatersupply“on”andcheckforleaks.
11.Turn“on”thepowerswitchandtestinstallationby
pressingthefrontmountedwaterswitch.Watershould
dispense.
12.Replacetowerrearpanelandthetopcover.
INSTALLATION OF THE PASS-THRU TOWER
1. Turn“off”thepowerswitchonthedispensingtower.
2. Removethetopcover,“wide”stanchionaccesspanel,
andcoverplateconcealingthefamilyofholesinthe
frontedgeofstanchion.
3. Removewireharnessconnectingthedispensingvalve
(adjacenttothe“wide”stanchion)totheelectronic
portioncontrolboardandthestanchion-mountedwater
switch.
4. Connectthewatervalvewireharnesstothevalveand
frontmountwaterswitchcommonandnormallyopen
terminals.