PREINSTALLATION
Changeout cart
The changeout cart is required for installing and removing the
customer changeable unit (CCU) containing the color dry ink. A
cart must also be used to store any CCUs not currently installed
in the printer. If you intend to print using more than one color
dry ink, you need to have one cart for each CCU.
Empty carts may be stored anywhere in your site that is
convenient and accessible. Carts should be stored in a
controlled environment, preferably in the same controlled
environment as the printer. This reduces the amount of time
required for the printer to set up the color developer housing
(inside the CCU) once it is installed, and reduces the amount of
time required for a change of dry ink color.
The dimensions of the cart are as follows:
• Width: 16.1 inches/409 mm
• Depth: 29.1 inches/739 mm
• Height: 36.9 inches/937 mm
• Weight: 130 pounds/59 kg (with CCU loaded).
Space planning guidelines
Placement of the LPS depends on the type and amount of
equipment used and the size and shape of the room used to
house the equipment. Some possible configurations for LPS
components include:
• Side-by-side
• L-shaped
• Face-to-face.
Equipment placement should optimize operator movements as
much as possible. Here are a few suggestions that may be
helpful:
• Place the system controller as close to the output end of the
printer as possible. This allows operators to simply reach
over to collect printed materials and check output.
• Consider the location of supplies in relation to the placement
of the equipment. For example, having paper as close to the
printer as possible will save time.
• Having the system controller as close to any offline interface
devices as possible will save time when monitoring tapes,
jobs, or other activities requiring operator intervention.
Clearance space requirements
Your LPS must be installed in a fixed location and have the
following space requirements available:
• 36 inches/914 mm of clearance on all sides of each
component
• 78 inches/1981 mm of vertical clearance (measured from the
floor to the lowest part of the ceiling or to the lowest
XEROX 4890 HIGHLIGHT COLOR LPS INSTALLATION PLANNING REFERENCE 1-11