Rubine RCF-LE800-5B User manual

Type
User manual
56"
Instruction Manual
SAFETY GUIDELINES AND INSTALLATION PROCEDURES
RCF-LE800-5B
REMOTE CONTROL CEILING FAN
2
1
8
3
4
7
13
5
6
HI
MED
LOW
OFF
1H
3H
6H
WHAT YOU HAVE
Please checkout following parts after opening the box:
COMPONENTS
PARTS
QUANTITY
1.DOWNROD
1
2.TOP CANOPY
1
4. FAN HOUSING & MOTOR
1
7. BLADE HOLDERS
3. COUPLING COVER
5. SWITCH COVER
6. SWITCH HOUSING
8. BLADES
9. BLADE DECORATIVE COVERS
1
1
5
5
5
SCREW PACKAGE
SCREW PACKAGE
13.BLADE H
O
LDER SCREWS
1
1
12. S BLADE DECORATIVE COVER CREWS
16
QUANTITY
14.EXPANSION J HOOK
10.
PARTS
QUANTITY
1
1
1
15.BALANCING KIT
1
10
9
15
10A
DIGITAL TOUCH SCREEN REMOTE
(COMES WITH 3V BATT X2)
12
11
14
11. RF RECEIVER 1
Page 1
10A. REMOTE HOLDER
WITH 2 MOUNTING SCREWS
FAN SIZE VOLTAGE
CARTON
WEIGHT
56” LE800 80W 250+-10% 8.13kg 9.13kg
MAX. FAN
POWER
MAX SPEED
(RPM)
PRODUCT
WEIGHT
220
240V/50Hz
Double pole single throw switch(Breaker Switch)
Earth
Ceiling Fan
Wall Switch (OFF/ON)
240VAC/50Hz
Power Supply
Page 2
1 ) Please do not install the ceiling fan at high humidity areas.
2 ) Distance between fan blades and ground must be at least 2.5 meter and above.
3 ) Do not touch fan blades with any objects when the ceiling fan is spinning.
4 ) To minimize the chances of electrical shock, power switch must be OFF before installing
or dismantling the ceiling fan or any electrical wiring connection.
5 ) All electrical connections must conform to the national electrical safety codes. To prevent
electrical shock, earth wire must be installed correctly (suitable for power supply of
240V AC/50Hz).
6 ) To ens
u
re your personal safety and optimize functions of the ceiling fan, assembly and
installation by qualified technician is highly recommended.
7 ) Only direct connection to wall switch is allowed. Please refer to diagram below.
WARNING
1 ) Do not bend the blade holders during installation, blades balancing or fan cleaning.
2 ) To prevent accidents, power switch must be OFF before ceiling fan installation.
3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in
accordance with all applicable codes and air conditioning engineers (ASHR
AE) or the
local qualified authorities.
4 ) Be cautious when drilling the wall to avoid damaging electrical wiring and other hidden
parts.
5 ) Ceiling fan must be hooked on concrete ceiling. Do not install the ceiling fan on plaster
ceiling or any types of drywall ceilings. During ceiling fan installation, all screws must be
tightened at all allocated parts.
8 ) This product is not provided with cord, plug or other means for disconnection from the
supply. Connecting or changing power cord or lead wire, must be done by qualified
personnel in order to avoid hazard.
9 ) This appliance is no
t i
ntended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
10 ) Children should be supervised to ensure that they do not play with the appliance.
11 ) The ceiling fan must be installed with means for disconnection incorporated in the fixed
wiring(wall switch) in accordance with the wiring rules.
A). TO ENSURE YOUR PERSONAL SAFETY, PLEASE READ THROUGH THE
INSTRUCTION MANUAL BEFORE USE
B). SAFETY GUIDELINES
Page 3
DIAGRAM 2
1 ) Remove 1st hex-head screw along
with the fixings (pin, metal nut, lock
washer and metal washer) from the
downrod.
2 ) Remove the pin on 2nd hex-head
screw and loosen the other fixings.
1 ) Lift the fan until the hanging wheel seat
on the mounted J hook.
2 ) Install the 1st hex-head screw
together with fixings.
3 ) Tighten up the 2nd hex-head screw
and fixing.
DIAGRAM 1
DIAGRAM 3
Safety Cable
Connector
Top Canopy
Coupling Cover
Screw x 2
Hex-head Screw
Motor Coupling
The 1st Hex-head Screw
Pin
Metal Nut
Metal Nut
Lock Washer
Metal Washer
The 2nd Hex-head Screw
Pin
Terminal Block
Fixings
Screw (Loosen)
(Tighten)
Hook
The 1st
Hex-head Screw
The 2nd
Hex-head Screw
1 ) Loosen 2 screws on the motor
coupling.
2 ) Insert the downrod through top canopy
and coupling cover.
3 ) Thread the safety cable through the
downrod.
4 ) Connect both connectors from the
downrod and fan motor.
5 ) Lock the downrod to the motor
coupling, tighten up with 2 hex-head
screws and fixings.
6 ) Tighten 2 screws on the motor
coupl
ing.
7 ) Slide down the coupling cover until it
rest on top of the fan housing.
Downrod
Installation without proper procedures as above mentioned might result to fan loosening or
falling.
INSTALLATION PROCEDURES
Before ceiling fan installation,please go through the procedures in detail
with picture diagram as reference.
STEP 1 (See Diagram 1)
STEP 2 (See Diagram 2)
STEP 3 (See Diagram 3)
WARNING:
Metal Washer
Pin
Metal Nut
Lock Washer
Fixings
Note:-
2.
Hook must be installed on concrete
ceiling.
(2.5 Nm torque for hex-head screws
and Metal Nut)
1. Remember to lock the pin after
tighten
i
ng hex-head screws.
Page 4
Fit the connected Receiver into top canopy.
Then, tighten the screw on downrod.
DIAGRAM 5
DIAGRAM 4
Receiver
NEUTRAL wire
(Black / Blue )
LIVE wire
(Red / Brown)
LN
LN
L
N
Receiver
Ceiling
Ceiling
Ceiling
Receiver
Receiver
Receiver
Brown Wire
(TO MOTOR L)
Blue Wire
(TO MOTOR N)
Red / Brown Wire
(Incoming LIVE Wire)
Black / Blue Wire
(Incoming NEUTRAL Wire)
Green Wire
(Incoming EARTH Wire)
Red Wire (AC in L)
Black Wire (AC in N)
Terminal Block (marked )
“L”
Terminal Block (marked )
“N”
FROM TO
!
Connect the Motor Wiring
to Receiver first!
Connect wiring as below:-
Downrod
Receiver
T
Screw
op Canopy
Terminal Block (marked
)
STEP 4 (See Diagram 4)
SUPPLY CIRCUIT
STEP 5 (See Diagram 5)
Brown
Blue
Green
EARTH wire
Page 5
Blade holder
Fan Blade
Decorative Cover
DIAGRAM 7
Switch Cover
Mounting Ring
Screw
Key Hole
Fan Motor
Fan Motor
Blade Holder
Fan Blade
Decorative Cover
Screw
ScrewX10
Plastic Block
(Must Remove)
Connector
(From Fan Motor)
Connector
(From Switch Housing)
Switch Housing
DIAGRAM 8
DIAGRAM 6
1 ) Screw the blade holder onto the fan
blade and decorative cover.
2 ) Repeat same step on all the
remaining fan blades.
1 ) Remove 1 screw from the mounting
ring and loosen the other 2 (Do not
remove).
2 ) Place the key hole of switch cover
through the 2 loosen screws and twist to
lock in place.
3 ) Tighten up all screws including the
one removed earlier.
4 ) Remove the 4 screws on the side of
the switch cover, and then connect both
connectors from fan motor and switch
housing.
5 ) Cover up with switch housing and
tighten all screws.
1 ) Remove all the plastic blocks and 10
screws from the motor housing.
2 ) Place assembled fan blades onto the
motor housing and tighten up all screws
removed previously.
Note:-
1. There are total of 10 screws holding
fan blad
es to the motor housing.
2. Plastic blocks must be removed and
discarded.
STEP 6 (See Diagram 6)
STEP 7 (See Diagram 7)
STEP 8 (See Diagram 8)
Page 6
WARNING!
FASTEN THE SAFETY CABLE TO THE MOUNTED J HOOK FOR
SAFETY PURPOSES.
Page 7
FLOOR
MIN 2.5m
SAFETY TIPS
Please ensure the distance between fan blade and ground must be at least 2.5
meter and above.
56"
RCF-LE800-5B
1
1
1
1
1
5
5
1
1
1 6
1
1
1
1
1.吊杆(吊管系统)
2. 吊盅
3.接头盖
4.风扇
5.
6.开关箱
7.叶
8.叶
.壁座带2个
11. 接
12
.叶片装饰盖螺丝
13
15 .平
1
14 .安
后,请
2
1
8
3
4
7
13
5
6
HI
MED
LOW
OFF
1H
3H
6H
10
9
15
10A
12
11
14
9.叶片装饰盖
5
10.遥控器附2颗3V电池
10A
1
尺寸 电压/频率
风扇最大功率 最大转速 净重 毛重
56”- LE800 80W 250+-10% 8.13kg 9.13kg
开关箱盖
.叶架安装备用螺丝
220 240V/50Hz
2
关(关/开
单掷路开
240V /50H z供电
A ) 为使
1. 在安,平,不
2. 安须关外。
3. 此接电
4. 注不要线件。
5. 吊扇悬挂,吊须锁
B)
1. 请不吊扇湿
2. 安装时,面2.3米以防
3. 吊扇,请,以
4. 为,安线时关
5. 所有电必准,吊扇线
于240V供
6. 为了的安使效果来安
7. 只,请
8. 本 其他线的时
9. 本产算由使用:上有
或缺
者。全负使的监
品)
10. 儿督以所有
11. 本极断置(过级III条下),线的固线
3
骤1(图1)
1)一个
(R销 和平
2)栓上的R销
骤2(图2)
1)头上的2颗
2)穿吊盅
3)穿过
4)接线线
5)马达
螺栓
6)开的
7)至马
骤3(图3)
1)已装
3)螺栓
2)下的
图1
图2
钢索
接头
线
图3
:-
2 .
1
.记得插上R销。
坚固
R销
华司
R销
第2个
第1个
(松
第2个
第1个
R销
华司
系统
x2
4
骤5(图5)
图5
图4
骤4(图4)
紅/棕线(入电的火线)
风扇
风扇
风扇
示為L
棕线(接至马达的 L 接点)
蓝线(接至马达的 N 接点)
绿入电的地线)
黑/藍线 (入电的中性线)
接收器
红线(交流电入电至 L)
黑线(交流电入电至 N)
示為N
接线终点
接线起点
螺丝
吊钟
管上
LN
LN
L
N
地线
中性线(黑/蓝色)
火线(红/棕色)
棕色
蓝色
绿色
!
连接线路如下表:
示為“ ”)
先把馬達的接線接到接收器!
5
图6
片装
图7
螺丝X10
图8
螺丝孔
叶架
片装
骤6(图6)
1)
上,
2)式安
骤8(图8
1)1颗
外2颗
2)
紧螺
3)
4)4颗
线线
5)
骤7(图7)
1)所有的阻动片和10颗螺丝
拆下来。
2)
锁紧
:-
1.总要10个叶架
2.阻拆下
强板
开关
线
少 2.5m
为了安全起见,请确保叶片距离地面至少2.5米或以上。
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Rubine RCF-LE800-5B User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages