SAFETY GUIDELINES AND INSTALLATION PROCEDURES
RCF-ECO-5BL
(DC1725-501-BC)
(DC1725-501-WC)
(DC1725-501-MB)
COMPONENTS
SCREW PACKAGE
WHAT YOU HAVE
Please checkout following parts after opening the box
Page 1
PARTS
QUANTITY
SCREW PACKAGE
QUANTITY
2. TOP CANOPY
3. COUPLING COVER
5. DC MOTOR WITH RECEIVER
6. FLY WHEEL
7. LIGHT KIT PLATE WITH LED
8. GLASS SHADE
9. BLADES
1
1
1
1
1
1
1
1
COMPONENTS
SCREW PACKAGE
FAN SIZE
VOLTAGE
MAX. FAN
POWER
MAX SPEED
(RPM)
56"
9.08kgs 11.16kgs
160±10%
47.7W
220~240V/50Hz
1. DOWNROD
(WOBBLE-FREE ASSEMBLY)
PRODUCT
WEIGHT
CARTON
WEIGHT
4. TOP HOUSING COVER
10. TRANSMITTER WITH 12V
BATTERY, HOLDER AND
2 MOUNTING SCREWS
5
1
11. BLADE HOLDER SCREWS
12. BLADE ATTACHMENT SCREWS
14. EXPANSION J HOOK
21
2
1
13. HEX-HEAD SCREWS
6
1
2
3
4
5
7
8
9
11
12
13
14
6
10
17
16
15
15. MOUNTING RING
17. FLAT HEAD SCREWS
16. LOCK WASHER SCREWS
3
3
1
LED LIGHT
POWER
17W
Page 2
Double pole single throw switch(Breaker Switch)
Earth
Ceiling Fan
Wall Switch (OFF/ON)
240VAC/50Hz
Power Supply
8 ) This product is not provided with cord, plug or other means for disconnection from the
supply. Connecting or changing power cord or lead wire, must be done by qualified
personnel in order to avoid hazard.
9 ) This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
10 ) Children should be supervised to ensure that they do not play with the appliance.
11 ) The appliance is fitted with means for disconnection from the supply mains having a
contact separation in all poles that provide full disconnection under overvoltage category
III conditions, and these means must be incorporated in the fixed wiring in accordance
with the wiring rules.
B ). SAFETY GUIDELINES
1 ) Please do not install the ceiling fan at high humidity areas.
2 ) Distance between fan blades and ground must be at least 2.3 meter and above.
3 ) Do not touch fan blades with any objects when the ceiling fan is spinning.
4 ) To minimize the chances of electrical shock, power switch must be OFF before installing
or dismantling the ceiling fan or any electrical wiring connection.
5 ) All electrical connections must conform to the national electrical safety codes. To prevent
electrical shock, earth wire must be installed correctly (suitable for power supply of
240V AC/50Hz).
6 ) To ensure your personal safety and optimize functions of the ceiling fan, assembly and
installation by qualified technician is highly recommended.
7 ) Only direct connection to wall switch is allowed. Please refer to diagram below.
WARNING
A ). TO ENSURE YOUR PERSONAL SAFETY, PLEASE READ THROUGH THE
INSTRUCTION MANUAL BEFORE USE
1 ) Do not bend the blade holders during installation, blades balancing or fan cleaning.
2 ) To prevent accidents, power switch must be OFF before ceiling fan installation.
3 ) Ceiling fan installation and electrical wiring must be done by qualified technician in
accordance with all applicable codes and air conditioning engineers (ASHRAE) or the
local qualified authorities.
4 ) Be cautious when drilling the wall to avoid damaging electrical wiring and other hidden
parts.
5 ) Ceiling fan must be hooked on concrete ceiling. Do not install the ceiling fan on plaster
ceiling or any types of drywall ceilings. During ceiling fan installation, all screws must be
tightened at all allocated parts.
Page 3
INSTALLATION PROCEDURES
Before ceiling fan installation, please go through the procedures in
detail with picture diagrams as reference.
STEP 1 (See Diagram 1)
1) Attach the fly wheel to motor.
2) Align fly wheel screw holes with motor
screw holes.
3) Install blade holder screws in the screw
package.Tighten up all the screws.
STEP 2 (See Diagram 2)
1) Install fan blades to the fly wheel.
2) Align the screw holes on the fan blade
and fly wheel.
3) Tighten up 2 blade attachment screws on
the bottom of the fly wheel.
4) Then tighten up 2 blade attachment
screws on the top of the fly wheel.
5) Repeat same step on all the remaining
fan blades.
DIAGRAM 1
Screw
Motor
Fly Wheel
DIAGRAM 2
Fly Wheel
Fan Blade
Screw (Bottom)
Screw (Top)
STEP 3 (See Diagram 3)
1) Attach the top housing cover to the
motor coupling and align the 3 small screw
holes on the top housing cover.
2) Attach the mounting ring to the top
housing and align the 3 big screw holes on
the top housing cover.
3) After all the 6 screw holes are aligned,
tighten the top housing cover and mounting
ring and motor coupling by using the 3 flat
head screws and 3 x lock washer screws
provided in the hardware package.
DIAGRAM 3
Top Housing
Cover
Mounting Ring
Small Screw Hole x3
(Lock Washer Screw)
Motor
Coupling
Big Screw Hole x3
(Flat Head Screw)
Page 4
WARNING:
Installation without proper procedures as above mentioned might result to fan loosening and
falling.
STEP 4 (See Diagram 4)
1 ) Remove the 1st hex-head screw
along with the fixings (pin, metal nut,
lock washer and metal washer) from the
downrod.
2 ) Remove the pin on 2nd hex-head
screw and loosen the other fixings.
STEP 5 (See Diagram 5)
1 ) Loosen the screw on the top canopy.
2 ) Insert the downrod through top
canopy and coupling cover.
3 ) Thread the safety cable through the
downrod.
4 ) Connect both connectors from the
downrod and fan motor.
5 ) Lock the downrod to the motor
coupling, tighten up with 2 hex-head
screws and fixings.
6 ) Tighten 2 screws on the motor
coupling.
7 ) Slide down the coupling cover until it
rest on top housing cover.
DIAGRAM 4
DIAGRAM 6
STEP 6 (See Diagram 6)
1 ) Lift the wobble-free assembly onto
the mounted hook.
2 ) Install the 1st hex-head screw
together with fixings.
3 ) Tighten up the 2nd hex-head screw
and fixing.
4 ) Tighten the 2 screws in the middle of
wobble-free assembly.
Note:-
1. Remember to lock the pin after
tightening hex-head screws.
2. Hook must be installed on concrete
ceiling.
DIAGRAM 5
Safety Cable
Connector
Top Canopy
Coupling Cover
Screw x 2
Hex-head Screw
Motor Coupling
The 1st Hex-head Screw
Pin
Metal Nut
Lock Washer
Metal Washer
The 2nd Hex-head Screw
Pin
Terminal Block
Fixings
Screw (Loosen)
Wobble-free
Assembly
2 Screws in the middle
(Tighten)
Hook
The 1st
Hex-head Screw
The 2nd
Hex-head Screw
Metal Washer
Pin
Metal Nut
Lock Washer
Fixings
Downrod
STEP 7 (See Diagram 7)
DIAGRAM 7
Ceiling
Ceiling
Ceiling
Red / Brown Wire
(Incoming LIVE Wire)
Black / Blue Wire
(Incoming NEUTRAL Wire)
Green Wire
(Incoming EARTH Wire)
Terminal Block (marked )L
Terminal Block (marked )N
FROM TO
Connect wiring as below:-
Page 5
SUPPLY CIRCUIT
EARTH wire
(Green)
NEUTRAL wire
(Black / Blue )
LIVE wire
(Red / Brown)
L
N
Top Canopy
Screw
(Tighten up)
DIAGRAM 8
STEP 8 (See Diagram 8)
Tug the top canopy to ceiling and tighten
up the screw on down rod to secure the
top canopy.
L
N
L
N
Terminal Block (marked )
From Ceiling
From Ceiling
From Ceiling
Page 6
STEP 10 (See Diagram 10)
1)
and loosen the other 2 (Do not remove).
2) Place the key hole of light kit plate
through the 2 loosen screws and twist to
lock in place.
3) Tighten up all screws including the one
removed earlier.
4) Connect the white and black wire
connector from fan motor to connector from
LED .
5) Re-install the LED to the light kit plate.
Remove 1 screw from the mounting ring
STEP 9 (See Diagram 9)
Remove the LED by removing the 3 screws
from the light kit plate.
STEP 11 (See Diagram 11)
Install the glass shade by twisting tightly.
DIAGRAM 9
Light Kit Plate
LED
DIAGRAM 11
Glass Shade
DIAGRAM 10
Light Kit Plate
LED
Black Wire
Connector
Black Wire
Connector
Screw
Mounting Ring
White Wire
Connector
White Wire
Connector
Key Hole
SAFETY TIPS:
Please ensure the distance between fan blades and ground
must be at least 2.3 meter and above.
WARNING!
FA ST E N T H E S A F E T Y C A B L E TO T H E M O U N T E D
EXPANSION J HOOK FOR SAFETY PURPOSES.
Page 7
GROUND
MIN 2.3m
56"
安 装 手 册
RCF-ECO-5BL
(DC1725-501-BC)
(DC1725-501-WC)
(DC1725-501-MB)
56"
1
1
1
1
1
1
1
1
5
1
1
2
3
4
5
7
8
9
11
12
13
14
6
10
17
16
15
21
2
1
6
3
3
1
配 件 明 细
1. 吊
2. 吊
3. 接
5. DC马
6. 中
7. 灯 LED
8. 玻
9. 叶
10. 发附1粒池 ,壁
和2颗
4. 马
11. 叶
12. 叶
13. 螺
14. 安全J勾
15. 补
17. 伞
16. 带
配 件 包
压/频
1
9.08kgs 11.16kgs
160±10%
47.7W
220~240V/50Hz
LED
17W
2
关/开
240V/50Hz供
(断
A) 为使
1. 在
2. 安
3. 此
4. 注线
5. 吊
B)
1. 请湿
2. 安面2.3米
3. 吊
4. 为线
5. 所线
于240V供
6. 为使
7. 只
8. 本线
9. 本使
使
10. 儿
11. 本置(过级III条下),线线
3
骤1(图1)
1)
2)
3)
骤2(图2)
1)
2)
3)
4)
5)
图1
图2
骤3(图3)
1)使
的3个
2)使
的3个
的3个
3)
的3个和3个
图3
x3
x3
4
骤4(图4)
1)
(R销
2)的R销
骤5(图5)
1)的2颗
2)穿
3)穿
4)线线
5)
6)
7)
骤6(图6)
1)
3)
4)的2颗
2)
:-
1. 记上R销
2. 吊
图4
图6
第2个
第1个
R销
x 2
线
图5
R销
R销
第2个
第1个
5
L
N
骤8(图8)
使
骤7(图7)
色 / 棕线
L
绿线
色 / 蓝线
N
接 线
出 线
线:-
图7
红 / 棕线
线
黑 / 蓝线
线
绿
线
图8
L
N
L
N
“ ”
From Ceiling
From Ceiling
From Ceiling
6
骤10(图10)
1)下1颗
2颗
2)的2个
3)
4)线线
线线
5)把LED装
骤9(图9)
的3颗下LED灯
骤11(图11)
LED
图9
图11
图10
LED
线
线
线
7
少2.3米
少 2.3米
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Rubine RCF-ECO56-5BL User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages