  • Hello! I am an AI chatbot trained to assist you with the Honeywell SL353 Series Micropower Omnipolar Digital Hall-Effect Sensor ICs Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation Instructions for the
SL353 Series Micropower Omnipolar
Digital Sensor ICs
50061206
Rev. B
CAUTION
ELECTROSTATIC
SENSITIVE
DEVICES
DO NOT OPEN OR HANDLE
EXCEPT AT A
STATIC FREE WORKSTATION
ESD SENSITIVITY:
CLASS 3A
CAUTION
ELECTROSTATIC DISCHARGE DAMAGE
This component is sensitive to electrostatic discharge (ESD). Take
normal ESD precautions in handling this product to prevent ESD-
induced damage and/or degradation.
Failure to comply with these instructions may result in
product damage.
CAUTION
PRODUCT DAMAGE
Ensure leads are adequately supported during any forming/
shearing operation so that they are not stressed inside the
plastic case.
• Limit exposure to high temperatures.
• Do not wave solder.
Failure to comply with these instructions may result in
product damage.
Characteristic Condition Min. TTyp. MMax. Unit
Supply voltage -0.5 6 V
Operating
temperature
ambient
-40
[-40]
150
[302]
°C
[°F]
Soldering
temperature
applied for
<10 s
265
[509]
°C
[°F]
Load current 5 mA
Table 1. Absolute Maximum Ratings
NOTICE
Absolute maximum ratings are the extreme limits that the device will
withstand without damage to the device. However, the electrical and
mechanical characteristics are not guaranteed as the maximum limits
(above recommended operating conditions) are approached, nor will
the device necessary operate at absolute maximum ratings.
Figure 1. Block/Electrical Diagram
Output
Flip
Flop
Clock
Counter
Decoder
Hall
+
-
Dual
Threshold
Comparator
Out
D
Q
0
V
GENERAL INFORMATION
SOLDERING/ASSEMBLY
Use an infrared reow process with temperatures of 245 °C [473 °F]
peak for 10 s max.
Sensing and Control
Table 2. Magnetic Characteristics for SL353 Series (2.2 V ≤ Vs ≤ 5.5 V, -40 °C [-40 °F] ≤ Ta ≤ 85 °C [185 °F])
Characteristic Condition Min. Typ. Max. Unit
Operate point:
positive
negative
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F]
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F
20
-110
60
-60
110
-20
Gauss
Release point:
positive
negative
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F]
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F
5
-95
45
-45
95
-5
Gauss
Hysteresis
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F]
3 15 60 Gauss
NOTICE
The magnetic eld strength (Gauss) required to cause the switch to change state (operate and release) will be as specied in the magnetic
characteristics. To test the switch against the specied magnetic characteristics, the switch must be placed in a uniform magnetic eld.
2 Honeywell Sensing and Control
SL353 Series Micropower Omnipolar
Digital Hall-Effect Sensor ICs
Rev. B
50061206
Characteristic
Condition
Min. Typ. Max. Unit
Supply voltage (Vs) Ta = -40 °C to 85 °C [-40 °F to 185 °F] 2.2 2.8 5.5 V
Active mode current
Vs = 2.8 V, Ta = 25 °C [77 °F]
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F]
2.5
2.5
4
9
mA
Sleep mode current
Vs = 2.8 V, Ta = 25 °C [77 °F]
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F]
1.5
1.5
2.5
8
μA
Average current:
SL353HT
SL353HT
SL353LT
SL353LT
Vs = 2.8 V, Ta = 25 °C [77 °F]
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F]
Vs = 2.8 V, Ta = 25 °C [77 °F]
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F]
0. 33
0.33
1.8
1.8
0.64
2.3
3
9
mA
mA
μA
μA
Active mode time
Vs = 2.8 V, Ta = 25 °C [77 °F]
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F]
3
3
6
6
9
30
μs
Period:
SL353HT
SL353HT
SL353LT
SL353LT
Vs = 2.8 V, Ta = 25 °C [77 °F]
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F]
Vs = 2.8 V, Ta = 25 °C [77 °F]
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F]
30
20
30
20
45
45
45
45
80
150
80
150
μs
μs
ms
ms
Duty cycle:
SL353HT
SL353HT
SL353LT
SL353LT
Vs = 2.8 V, Ta = 25 °C [77 °F]
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F]
Vs = 2.8 V, Ta = 25 °C [77 °F]
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F]
10
5
0.01
0.005
13
13
0.013
0.013
16
25
0.016
0.025
%
Vout:
high
high
low
low
Vs = 2.8 V, Ta = 25 °C [77 °F], load current = 100 μA
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F], load current = 100 μA
Vs = 2.8 V, Ta = 25 °C [77 °F], load current = 100 μA
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F], load current = 100 μA
Vs - 0.15
Vs - 0.25
Vs - 0.11
Vs - 0.11
0.11
0.11
0.15
0.25
V
Operating
temperature
Vs = 2.2 V to 5.5 V, Ta = -40 °C to 85 °C [-40 °F to 185 °F] -40 [-40] 85 [185] °C [°F]
Storage temperature -40 [-40] 150 [302] °C [°F]
Table 3. Electrical and Environmental Characteristics for SL353 Series
(At 2.2 V ≤ Vs ≤ 5.5 V, -40 °C [-40 °C] ≤ Ta ≤ 85 °C [185 °F] and Vs = 2.8 V, Ta = 25 °C [77 °F] unless otherwise specified.)
NOTICE
These Hall-effect sensors ICs may have an initial output in either the on or off state if powered up with an applied magnetic field in the
differential zone (applied magnetic field > Brp and < Bop). Honeywell recommends that the application circuit designer allow 10 μs after
apply voltage has reached its rated value for the output voltage to stabilize.
The sensor will turn LOW when the magnetic field is present and switch to HIGH when the field is removed. The sensor will latch and
hold the state during the sleep “mode”.
Honeywell Sensing and Control 3
SL353 Series Micropower Omnipolar
Digital Hall-Effect Sensor ICs
Rev. B
50061206
Figure 2. Typical Performance Characteristics
SL353HT and SL353LT Typical Magnetic Performance vs
Temperature
SL353HT and SL353LT Typical Period vs Temperature
SL353HT and SL353LT Typical Actve Mode Time vs
Temperature
SL353HT Typical Average Current vs Temperature
SL353LT Typical Average Current vs Temperature
Release Point (Neg.)
-40
[-40]
-100
-80
-60
-40
-20
0
20
40
60
80
100
Operate P oint (Neg.)
Operate Point (Pos.)
Release Point (Pos.)
Temperature (°C [°F])
Magnetic Sw itch Point (Gauss)
-20
[-4]
0
[32]
20
[68]
40
[104]
60
[140]
80
[176]
Vs = 5.5 V
Vs = 2.2 V
Period
s for SL353HT, ms for SL353LT)
0
20
40
60
80
100
Vs = 2.8 V
-40
[-40]
-20
[-4]
0
[32]
20
[68]
40
[104]
60
[140]
80
[176]
Temperature (°C [°F])
Active Mode Ti me s)
2
4
6
8
10
12
14
16
18
20
Vs = 5.5 V
Vs = 2.2 V
Vs = 2.8 V
-40
[-40]
Temperature (°C [°F])
-20
[-4]
0
[32]
20
[68]
40
[104]
60
[140]
80
[176]
Average Current (mA)
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
Vs = 5.5 V
Vs = 2.2 V
Vs = 2.8 V
-40
[-40]
Temperature (°C [°F])
-20
[-4]
0
[32]
20
[68]
40
[104]
60
[140]
80
[176]
Vs = 2.2 V
Average Current A)
0
1
2
3
4
5
6
7
8
Vs = 5.5 V
Vs = 2.8 V
-40
[-40]
Temperature (°C [°F])
-20
[-4]
0
[32]
20
[68]
40
[104]
60
[140]
80
[176]
4 Honeywell Sensing and Control
SL353 Series Micropower Omnipolar
Digital Hall-Effect Sensor ICs
Rev. B
50061206
Figure 3. Mounting and Tape/Reel Dimensions (For reference only. mm/[in].)
Sensor
Tape
Reel
3
GND
(-)
2,90
[0.114]
1
VCC
(+)
2
OUTPUT
1,40 Max.
[0.055]
1,20
[0.047]
0,77
[0.030]
0,60
[0.024]
0,787
[0.031]
0,413
[0.016]
1,90
[0.075]
0,95
[0.037]
3X 0,40 Ty p.
[0.016]
2,80
[0.110]
1,60
[0.063]
Nominal to IC
sensing
surface
Nominal to IC
center
6
1
1
6
0,20
[0.008]
1,40
[0.055]
0,061
[0.002]
3,15
[0.124]
3,20
[0.125]
1,50
[0.059]
2,00
[0.079]
4,00
[0.157]
4,00
[0.157]
8,00
[0.315]
1,75
[0.069]
3,50
[0.138]
1,00
[0.039]
To p
cover
tape
60,0
[2.362]
10,9
[0.429]
14,4
[0.567]
8,40
[0.331]
40,0
[1.57]
4,00
[0.157]
10
[0.394]
20,2
[0.795]
2,0
[0.079]
13,0
[0.512]
178
[7.000]
Measured at
hub
Measured at
hub
Measured at
outer edge
Min.
Max.
Sensor Showing Polarity
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
50061206-B-EN IL50
April 2015
© 2015 Honeywell International Inc. All rights reserved.
SL353 Series Macropower Omnipolar
Digital Hall-Effect Sensor ICs
Rev. B
50061206
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s stan-
dard product warranty applies unless agreed to otherwise by
Honeywell in writing; please refer to your order acknowledgement
or consult your local sales office for specific warranty details. If
warranted goods are returned to Honeywell during the period of
coverage, Honeywell will repair or replace, at its option, without
charge those items it finds defective. The foregoing is buyers
sole remedy and is in lieu of all other warranties, expressed
or implied, including those of merchantability and tness for
a particular purpose. In no event shall Honeywell be liable for
consequential, special, or indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
Honeywell serves its customers through a worldwide network of
sales offices, representatives and distributors. For application
assistance, current specifications, pricing or name of the nearest
Authorized Distributor, contact your local sales office or:
Internet: sensing.honeywell.com
Phone and Fax:
USA/Canada +1-800-537-6945
International +1-815-235-6847; +1-815-235-6545 Fax
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the product
could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
/