American Hearth ALS-18YK-1 is a gas log set for unvented gas log heaters or vented decorative appliances. It complies with ANSI Z21.11.2 Unvented Heaters and also complies with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. The log set features proper log placement, rock wool can be added to burners for a glowing ember effect, and decorative lava rock or small wood pieces should never be placed on the burner. Ceiling fans, portable fans, or logs installed near cold air returns can affect the performance of the log set and should be avoided.

American Hearth ALS-18YK-1 is a gas log set for unvented gas log heaters or vented decorative appliances. It complies with ANSI Z21.11.2 Unvented Heaters and also complies with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. The log set features proper log placement, rock wool can be added to burners for a glowing ember effect, and decorative lava rock or small wood pieces should never be placed on the burner. Ceiling fans, portable fans, or logs installed near cold air returns can affect the performance of the log set and should be avoided.

Page 1
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
LOG SET FOR UNVENTED
GAS LOG HEATER
OR
VENTED DECORATIVE APPLIANCE
MODELS
ALS-18YK-1
ALS-24YK-2
ALS-30YK-2
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
Log sets comply with ANSI Z21.11.2 Unvented Heaters
and also comply with ANSI Z21.60 Decorative Vented
Appliances for Solid Fuel Burning Fireplaces. State or
local codes may only allow operation of log sets in a
YHQWHGFRQ¿JXUDWLRQ&KHFN\RXUVWDWHRUORFDOFRGHV
YORKTOWN
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
LS-24YK-2 Shown
GAS-FIRED
WARNING: If the information in these instructions
DUHQRWIROORZHGH[DFWO\D¿UHRUH[SORVLRQPD\UH-
sult causing property damage, personal injury or
loss of life.
² 'RQRWVWRUHRUXVHJDVROLQHRURWKHUÀDPPDEOH
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
 'RQRWWU\WROLJKWDQ\DSSOLDQFH
 'R QRW WRXFK DQ\ HOHFWULFDO VZLWFK GR QRW
use any phone in your building.
 ,PPHGLDWHO\ FDOO \RXU JDV VXSSOLHU IURP D
neighbors phone. Follow the gas suppliers
instructions.
 ,I\RXFDQQRWUHDFK\RXUJDVVXSSOLHUFDOOWKH
¿UHGHSDUWPHQW
Installation and service must be performed by a
TXDOL¿HGLQVWDOOHUVHUYLFHDJHQF\RUWKHJDVVXS-
plier.
7KH 45 &RGH EHORZ SURYLGHV D OLQN WR RXU KHOSIXO
“how-to” video. To get started, scan the code with your
smart phone or tablet.
28190-2-1015Page 2
Section Page
Important Installation Guidelines ....................................................................................................3
General Information ........................................................................................................................3
Requirements for Canada ..............................................................................................................4
/RJ,GHQWL¿FDWLRQ/6<. .............................................................................................................5
/RJ3ODFHPHQW/6<. ...........................................................................................................6-12
/RJ,GHQWL¿FDWLRQ/6<. ...........................................................................................................13
Log Placement LS-24YK .........................................................................................................14-21
/RJ,GHQWL¿FDWLRQ/6<. ...........................................................................................................22
Log Placement LS-30YK .........................................................................................................23-31
(PEHU3ODFHPHQW/6<.3KRWRV .............................................................................................32
Ember Placement LS-24YK Photos .............................................................................................33
Ember Placement LS-30YK Photos .............................................................................................34
Master Parts Distributor List .........................................................................................................35
How to Order Repair Parts ...........................................................................................................35
Parts Lists and Parts Views ..........................................................................................................36
TABLE OF CONTENTS
28190-2-1015 Page 3
Proper Log Placement
Log placement is critical to proper burner performance. Logs must
be correctly positioned onto the burner. The photos in this manual
show the proper pinned position for logs on this set. Owners need
to be shown proper log placement and instructed not to move the
logs.
/RJVPXVW¿W¿UPO\RQWRWKHEXUQHUZKHQSRVLWLRQHGDVVKRZQLQ
the photos. Malformed logs or logs with sloppy pin holes must be
replaced.
3URSHU3ODFHPHQWRI5RFN:RRODQG'HFRUDWLYH/DYD5RFN
Rock wool can be added to burners for a glowing ember effect. It
must be positioned only on the front portion of the burner. The photos
in this manual show the proper placement of rock wool.
Decorative lava rock or small wood pieces should never be placed
RQWKHEXUQHU7KHVHLWHPVDUHRQO\IRUSODFHPHQWRQWKHÀRRURI
WKH¿UHSODFHRU¿UHER[
3URSHU3ULPDU\$LUÀRZLQWR%XUQHU
)RU SURSHU EXUQHU RSHUDWLRQ DQG ÀDPH DSSHDUDQFH WKH ÀRZ RI
SULPDU\DLULQWRWKHYHQWXULWXEHORFDWHGRQWKHUHDURIWKHEXUQHU
PXVWQRWEHUHGXFHG7KLVÀRZRIDLULVUHGXFHGLIGLUWOLQWRURWKHU
obstructions build-up around or inside the venturi. Any obstruction
LQWKHYHQWXULWXEHDUHDPXVWEHUHPRYHG7KHÀRZRIDLULQWRWKH
YHQWXULLVDOVRUHGXFHGLIWKHJDVRUL¿FHLVQ¶WFHQWHUHGLQWKHYHQWXUL
inlet and/or is not aligned with the venturi. Any misalignment of the
EXUQHURUL¿FHPD\EHFRUUHFWHGE\EHQGLQJWKHVKXWWHUFDSKROGLQJ
WKHRUL¿FHWRWKHLQOHWRIWKHYHQWXULWXEH
Ceiling Fans, Portable Fans or Logs Installed Near Cold Air
Returns
&HLOLQJ IDQV RU RVFLOODWLQJ ÀRRU W\SH IDQV QHHG WR EH PRQLWRUHG
during the operation of vent-free logs. If the air blows directly into
WKHÀDPHFDXVLQJLWWRLPSLQJHRQWKHORJVHWRU¿UHER[LWVKRXOGEH
turned off or redirected. Ceiling fans could be reversed to possibly
HOLPLQDWHÀDPHLPSLQJHPHQWDQGWKHÀRRUIDQFRXOGEHUHGLUHFWHG
8SRQLQVWDOODWLRQEHDZDUHRIDQ\FROGDLUUHWXUQVRUYHQWVLQWKH
SUR[LPLW\RIWKHORJVHW$Q\GUDIWFUHDWHGDURXQGDYHQWIUHHORJ
VHWFDQFDXVHWKHÀDPHWRLPSLQJHRQWKHORJDQGFUHDWHDVRRWLQJ
situation.
WARNING:'RQRWDOORZ IDQV WR EORZ GLUHFWO\ LQWR WKH ¿UHSODFH
$YRLGDQ\GUDIWVWKDWDOWHUEXUQHUÀDPHSDWWHUQV
WARNING: 'RQRWXVHDEORZHULQVHUWKHDWH[FKDQJHULQVHUWRU
other accessory not approved for use with this heater.
Candles
Avoid the use of scented or decorative candles while the log set is in
operation. Candles produce a residue in the air that creates a soot like
VXEVWDQFH%XUQLQJFDQGOHVZKLOHWKHORJVHWLVRSHUDWLQJPDJQL¿HV
WKHSUREOHP,WVKRXOGEHQRWHGWKDWFDQGOHVLQJHQHUDOSURGXFH
soot. The amount of time burned and the quantity of candles burned
will determine the amount of soot produced and deposited.
0DNH2ZQHUV$ZDUHRI3URSHU/RJ6HW2SHUDWLRQ
Properly installed and properly maintained log sets do not deposit
VRRWRQWKHORJV,IXVHUVVHHVRRWDSSHDURQDORJFDOOIRUVHUYLFH
Do not continue to operate the log set.
6XQNHQ)LUHSODFH
,ILQVWDOOLQJWKLVXQLWLQWRDVXQNHQ¿UHSODFH\RXPXVWUDLVHWKHÀRRU
WRLQVXUHDGHTXDWHDLUÀRZDQGJXDUGDJDLQVWVRRWLQJ5DLVH¿UHSODFH
ÀRRUXVLQJDQRQFRPEXVWLEOHPDWHULDOZKLFKLVVHFXUH
Glass Doors
Make sure that glass doors are open during all operations of the
logset. The opening of the glass door frame should be the dimension
XVHGIRUWKHPLQLPXPIURQWRSHQLQJRIWKH¿UHER[
Wood Burning Fireplaces
7KHLQWHULRURIWKH¿UHER[DQGWKHFKLPQH\VKRXOGEHFOHDQHGDQG
free of all creosote before installing a gas burning log set. Creosote
will soften when heated and can drop on the logset causing odors
and possibly sooting.
WARNING:%HIRUHLQVWDOOLQJLQDVROLGIXHOEXUQLQJ¿UHSODFHWKH
FKLPQH\ÀXHDQG¿UHER[PXVWEHFOHDQHGRIVRRWFUHRVRWHDVKHV
DQGORRVHSDLQWE\DTXDOL¿HGFKLPQH\FOHDQHU
4XDOL¿HG,QVWDOOLQJ$JHQF\
,QVWDOODWLRQ DQG UHSODFHPHQW RI JDV SLSLQJ JDV XWLOL]DWLRQ
equipment or accessories and repair and servicing of equip-
PHQWVKDOOEHSHUIRUPHGRQO\E\DTXDOL¿HGDJHQF\7KHWHUP
TXDOL¿HGDJHQF\PHDQVDQ\LQGLYLGXDO¿UPFRUSRUDWLRQ
or company that either in person or through a representa-
WLYHLVHQJDJHGLQDQGLVUHVSRQVLEOHIRUDWKHLQVWDOODWLRQ
WHVWLQJRUUHSODFHPHQWRIJDVSLSLQJRUEWKHFRQQHFWLRQ
LQVWDOODWLRQWHVWLQJUHSDLURUVHUYLFLQJRIHTXLSPHQWWKDWLV
H[SHULHQFHGLQVXFKZRUNWKDWLVIDPLOLDUZLWKDOOSUHFDXWLRQV
UHTXLUHGDQGWKDWKDVFRPSOLHGZLWKDOOWKHUHTXLUHPHQWVRI
the authority having jurisdiction.
7KHLQVWDOODWLRQPXVWFRQIRUPZLWKORFDOFRGHVRULQWKHDEVHQFH
RI ORFDO FRGHV ZLWK WKH National Fuel Gas Code, ANSI Z223.1/
NFPA54.*
*Available from the American National Standards Institute, Inc. 11 West
42nd St., New York, N.Y. 10018.
State of Massachusetts: The installation must be made
E\DOLFHQVHGSOXPEHURUJDV¿WWHULQWKH&RPPRQZHDOWK
of Massachusetts.
6HOOHUVRIXQYHQWHGSURSDQHRUQDWXUDO JDV¿UHGVXSSOH-
mental room heaters shall provide to each purchaser a
copy of 527 CMR 30 upon sale of the unit.
,Q WKH 6WDWH RI 0DVVDFKXVHWWV XQYHQWHG SURSDQH DQG
QDWXUDOJDV¿UHGVSDFHKHDWHUVVKDOOEHSURKLELWHGLQEHG-
rooms and bathrooms.
IMPORTANT INSTALLATION GUIDELINES
GENERAL INFORMATION
28190-2-1015Page 4
REQUIREMENTS FOR CANADA
This unit cannot EH LQVWDOOHG LQ D 819(17(' DSSOLFDWLRQ WKLV
unit can only be installed as a VENTED application with these
requirements.
IMPORTANT SAFETY INFORMATION
This unit complies with ANSI Z21.60and CGA 2.26 Decorative
Gas Appliances For Installation In Solid Fuel Burning Fireplaces.
'RQRWEXUQZRRGRUVROLGIXHOVLQD¿UHSODFHZKHUHDGHFRUDWLYH
gas log set is installed. This appliance is for installation only in
DVROLGIXHOEXUQLQJ¿UHSODFHPDVRQU\¿UHSODFHRUPDQXIDFWXUHG
¿UHSODFH
Warning: $Q\PRGL¿FDWLRQWRWKLVJDVORJVHWRUWRFRQWUROV FDQ
be dangerous. Improper installation or use of the gas log set can
FDXVHVHULRXVLQMXU\RUGHDWKIURP¿UHEXUQVH[SORVLRQRUFDUERQ
PRQR[LGHSRLVRQLQJ
 3OHDVHIROORZDOOORFDOFRGHVUHJDUGLQJLQVWDOODWLRQFRPEXV-
tion and ventilation air or in the absence of local codes follow
WKH1DWLRQDO)XHO*DV&RGH$16,=86LQVWDOODWLRQRU
&$1&*$%,QVWDOODWLRQ&RGH&DQDGDLQVWDOODWLRQ
 3URSHULQVWDOODWLRQEXUQHUSDQORFDWLRQDQGORJSODFHPHQWLV
important to achieve optimum look and performance of your
gas log set. The logs have been designed for easy location
and placement on the grate and must be followed for proper
operation.
3. Do not operate this log set with glass doors in the closed posi-
WLRQ$¿UHSODFHVFUHHQPXVWEHLQSODFHZKHQWKHORJVHWLV
burning. Adequate combustion air must be provided for proper
YHQWLQJ$OOÀDPHVVKRXOGJRXSDQGRXWWKHWRSRIWKH¿UHER[
LQWRWKHÀXHYHQW,IDQ\ÀDPHVÀRDWRUFXUOIRUZDUGLQWRWKH
URRPGRQRWRSHUDWHDSSOLDQFH&KHFNIRUDQRSHQÀXHDQG
adequate combustion air into the room. A damper clamp must
EHLQVWDOOHGRQWKH¿UHER[GDPSHUWRPDLQWDLQDQRSHQÀXH
YHQWFRQGLWLRQ6HH¿UHSODFHLQVWUXFWLRQVPDQXDOIRULQVWDOOLQJ
damper clamp.
4. Young children must be carefully supervised when they are in
the same room as the gas log while in operation. Do not place
VWRFNLQJVFORWKLQJRUDQ\ÀDPPDEOHPDWHULDODERYHRUQHDU
WKH¿UHSODFH
5. Do not substitute or use materials other than those supplied
for use with the log set.
6. Also refer to IMPORTANT SAFETY INFORMATION on page
3 of this manual
:$51,1* '2 127 23(5$7( 7+,6 *$6 /2* 6(7 :,7+
GLASS DOORS CLOSED
 &ORWKLQJRURWKHUÀDPPDEOHPDWHULDOVKRXOGQRWEHSODFHGRQ
or near the appliance.
 'RQRWSODFHWUDVKRURWKHUDUWLFOHVRQWKHORJVHWGXULQJRS-
eration.
 'XULQJPDQXIDFWXULQJIDEULFDWLQJDQGVKLSSLQJYDULRXVFRP-
SRQHQWVRIWKLVDSSOLDQFHDUHWUHDWHGZLWKFHUWDLQRLOV¿OPVRU
bonding agents. These bonding agents are not harmful but
may produce annoying smoke and smells as they are burned
off during initial operation of the appliance. This is a normal
temporary occurrence. A window should be opened during the
initial bake out period.
 .HHSEXUQHUDQGFRQWUROFRPSDUWPHQWFOHDQ
 WARNING: %HIRUHLQVWDOOLQJLQDVROLGIXHOEXUQLQJ¿UHSODFH
WKHFKLPQH\ÀXHDQG¿UHER[PXVWEHFOHDQHGRIVRRWFUHR-
VRWHDVKHVDQGORRVHSDLQWE\DTXDOL¿HGFKLPQH\FOHDQHU
 ,QVWDOODWLRQDQGUHSDLUVKRXOGEHGRQHE\DTXDOL¿HGVHUYLFH
person. The appliance should be inspected before use and
DWOHDVWDQQXDOO\E\DTXDOL¿HGVHUYLFHSHUVRQ0RUHIUHTXHQW
FOHDQLQJPD\EHUHTXLUHGGXHWRH[FHVVLYHOLQWIURPFDUSHWLQJ
EHGGLQJPDWHULDOVHWF,WLVLPSHUDWLYHWKDWFRQWUROFRPSDUW-
PHQWVEXUQHUVDQGFLUFXODWLQJDLUSDVVDJHZD\VRIWKHDSSOL-
ance be kept clean.
 Do notSXWDQ\WKLQJDURXQGWKH¿UHSODFHWKDWZLOOREVWUXFWWKH
ÀRZRIYHQWLODWLRQDLU
 Do keep the appliance area clear and free from combustible
PDWHULDOJDVROLQHDQGRWKHUÀDPPDEOHYDSRUVDQGOLTXLGV
 $\HDUO\H[DPLQDWLRQ DQG FOHDQLQJ RI WKH YHQWLQJ V\VWHPRI
WKHVROLGIXHOEXUQLQJ¿UHSODFHPXVWEHSHUIRUPHGE\DTXDOL-
¿HGDJHQF\
 Do make a periodic visual check of pilot and burners. Clean
and replace damaged parts.
 Do not use this appliance if any part has been under water.
,PPHGLDWHO\FDOODTXDOL¿HGVHUYLFHWHFKQLFLDQWRLQVSHFWWKH
appliance and to replace any part of the control system and
any gas control which has been under water.
 1HYHUEXUQVROLGIXHOVLQ¿UHSODFHZKHUHDJDVORJVHWLVLQ-
stalled.
 7KLVXQLWFRPSOLHVZLWK$16,='HFRUDWLYH9HQWHG$SSOL-
ances for Solid Fuel Burning Fireplaces. State or local codes
PD\RQO\DOORZRSHUDWLRQRIWKLVDSSOLDQFHLQDYHQWHGFRQ¿JX-
ration. Check your state or local codes.
28190-2-1015 Page 5
Log
Description
Part Number Front View Top View
Log A R10257
Log B 5
Log C R10260
Log D R10259
Log F R10262
Note: ALS-18YK does not contain a Log E and is not needed for assembly.
ALS-18YK LOG IDENTIFICATION
28190-2-1015Page 6
Ember Placement
Apply loose material (glowing embers) per appropriate Installation
Instructions and Owner's Manual. Replacement of loose material
(glowing embers) must be purchased from Empire Comfort Sys-
WHPV,QF$SSOLFDWLRQRIH[FHVVORRVHPDWHULDOJORZLQJHPEHUV
may adversely affect performance of the heater. WARNING: All
previously applied loose material must be removed prior to reap-
plication.
Note: A single layer of embers is to be used when applying Platinum
Bright Embers (alone or in combination with production embers)
to the burner.
%HIRUH\RXEHJLQ'RQRWKDQGOHWKHVHORJVZLWK\RXUEDUHKDQGV
$OZD\VZHDUJORYHVWRSUHYHQWVNLQLUULWDWLRQ$IWHUKDQGOLQJORJV
wash your hands gently with soap and water.
All Logs
The positioning of the logs is critical to the safe and clean operation
of this heater. Sooting and other problems may result if the logs are
QRWSURSHUO\DQG¿UPO\SRVLWLRQHGLQWKHDSSOLDQFH
A
B
D
C
E
F
Replacement Loose Material
(glowing embers)
Part Number
$/6<. 15999
Platinum Bright Embers PE-20-1
LOG PLACEMENT ALS-18YK
Scan this code to see the log assembly video.
WARNING
Failure to position the parts in accordance with this diagram or
IDLOXUHWRXVHRQO\SDUWVVSHFL¿FDOO\DSSURYHGZLWKWKLVDSSOLDQFH
may result in property damage or personal injury.
WARNING
This appliance is equipped for (natural or propane) gas. Field
conversion is not permitted.
Attention: Do not use Figure 1 to order replacement logs. Refer to
Page 35 Parts List and Parts View to order logs for your appropriate
model number.
Log Placement
LS-18YK Logs
Figure 1
Note: LS-18YK does not contain a Log E and is not needed
for assembly.
28190-2-1015 Page 7
1. Place Log C onto right rear pin on rear log support as shown below.
LOG PLACEMENT ALS-18YK
28190-2-10153DJH
2. Place Log D onto left rear pin on rear log support as shown below.
LOG PLACEMENT ALS-18YK
28190-2-1015 Page 9
3. Place Log A onto two front left burner pins as shown below.
LOG PLACEMENT ALS-18YK
28190-2-1015Page 10
4. Place Log B onto two front right burner pins as shown below.
LOG PLACEMENT ALS-18YK
28190-2-1015 Page 11
5. Insert boss on Log F into recess on right side of Log C and Log B as shown below.
LOG PLACEMENT ALS-18YK
28190-2-1015Page 12
6. Log placement is completed.
LOG PLACEMENT ALS-18YK
28190-2-1015 Page 13
Log
Description
Part Number Front View Top View
Log A R10264
Log B R10265
Log C R10267
Log D R10266
Log E 5
Log F R10262
ALS-24YK LOG IDENTIFICATION
28190-2-1015Page 14
Ember Placement
Apply loose material (glowing embers) per appropriate Installation
Instructions and Owner's Manual. Replacement of loose material
(glowing embers) must be purchased from Empire Comfort Sys-
WHPV,QF$SSOLFDWLRQRIH[FHVVORRVHPDWHULDOJORZLQJHPEHUV
may adversely affect performance of the heater. WARNING: All
previously applied loose material must be removed prior to reap-
plication.
Note: A single layer of embers is to be used when applying Platinum
Bright Embers (alone or in combination with production embers)
to the burner.
%HIRUH\RXEHJLQ'RQRWKDQGOHWKHVHORJVZLWK\RXUEDUHKDQGV
$OZD\VZHDUJORYHVWRSUHYHQWVNLQLUULWDWLRQ$IWHUKDQGOLQJORJV
wash your hands gently with soap and water.
All Logs
The positioning of the logs is critical to the safe and clean operation
of this heater. Sooting and other problems may result if the logs are
QRWSURSHUO\DQG¿UPO\SRVLWLRQHGLQWKHDSSOLDQFH
A
B
D
C
E
F
Replacement Loose Material
(glowing embers)
Part Number
ALS-24YK 15970
Platinum Bright Embers PE-20-1
LOG PLACEMENT ALS-24YK
Scan this code to see the log assembly video.
WARNING
Failure to position the parts in accordance with this diagram or
IDLOXUHWRXVHRQO\SDUWVVSHFL¿FDOO\DSSURYHGZLWKWKLVDSSOLDQFH
may result in property damage or personal injury.
WARNING
This appliance is equipped for (natural or propane) gas. Field
conversion is not permitted.
Attention: Do not use Figure 2 to order replacement logs. Refer to
Page 35 Parts List and Parts View to order logs for your appropriate
model number.
Log Placement
LS-24YK Logs
Figure 2
28190-2-1015 Page 15
1. Place Log C onto right rear pin on rear log support as shown below.
LOG PLACEMENT ALS-24YK
28190-2-1015Page 16
2. Place Log D onto left rear pin on rear log support as shown below.
LOG PLACEMENT ALS-24YK
28190-2-1015 Page 17
3. Place Log A onto two front left burner pins as shown below.
LOG PLACEMENT ALS-24YK
28190-2-10153DJH
4. Place Log B onto two front right burner pins as shown below.
LOG PLACEMENT ALS-24YK
28190-2-1015 Page 19
5. Insert boss on Log F into recess on right side of Log C and Log B. See image below.
LOG PLACEMENT ALS-24YK
28190-2-1015Page 20
6. Insert boss on Log E into recess on Log D and resting on Log A. See image below.
LOG PLACEMENT ALS-24YK
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

American Hearth ALS-18YK-1 Owner's manual

Type
Owner's manual
This manual is also suitable for

American Hearth ALS-18YK-1 is a gas log set for unvented gas log heaters or vented decorative appliances. It complies with ANSI Z21.11.2 Unvented Heaters and also complies with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. The log set features proper log placement, rock wool can be added to burners for a glowing ember effect, and decorative lava rock or small wood pieces should never be placed on the burner. Ceiling fans, portable fans, or logs installed near cold air returns can affect the performance of the log set and should be avoided.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI