PROOFING CABINET
INSTALLATION OPERATION AND CARE OF
PROOFING CABINET
MODEL: POA0001 R02
4-INS-POA0001 R02
LIMITED WARRANTY
All equipment which is sold under ANVIL trademark and used for
commercial purposes is warranted against defects in materials and
workmanship. The warranty runs for two years from the date of
original installation and is for the benet of the original purchaser
only. All other Warranties, expressed or implied, statutory or
otherwise, including without limitations any implied Warranty of
Merchantability or tness for purpose are excluded. The Seller shall
in no event be liable for direct, indirect or consequential damages in
connection with ANVIL commercial products.
The Sellers obligation under this Warranty is limited to the
repair of defects without charge. Defective units must be taken or
shipped,transportation charges prepaid, to ANVIL.
This Warranty is not eective if damage occurs because of accident,
carelessness, improper installation, lack of proper set-up,
supervision when required or if the equipment is installed or
operated in any manner contrary to the installation and
operating instructions. In these cases, repairs will be made at a
reasonable cost. Work performed by unauthorized personnel or
unauthorized service agencies using non Anvil spares voids this
Warranty.
THESE INSTRUCTIONS MUST BE FOLLOWED FOR US TO
GUARANTEE OUR FULL SUPPORT OF YOUR CLAIM FOR
PROTECTING AGAINST LOSS FROM CONCEALED
DAMAGE. THE FORM FOR FILING SUCH A CLAIM WILL BE
PROVIDED BY THE CARRIER.
UNPACKING
Unpack the product and check for any damage incurred during
transit. This should be reported to the responsible carrier, railway or
postal authority, and a request for a damage report should be made.
GENERAL INSTALLATION AND OPERATION INSTRUCTIONS
1. Set the control knob to the desired setting. Position 1.5
and 2 settings are for bread mixtures requiring temperatures
from 35ºC to 38ºC with humidity
2. The prover is equipped with the following :
• A pilot light that indicates the control action of the thermostat..
• A removable water tray that is positioned in the bottom of the
unit. This is to be lled with water to create a steamy, humid
environment.
• The ability to accommodate 600 X 400 baking trays.
• Adjustable legs so that it can stay level on uneven surfaces.
• Is built with a reinforced top so as too allow an oven to stand
on top for convenience.
1 10
WARNING
Burn Hazard.
Do not touch hot food,liquid or heating surfaces
while equipment is heating or operating
Hot surfaces and food can burn skin. Allow the hot surfaces to cool
before handling
CLEANING
1. Always ensure that the unit is disconnected from the mains
power supply before cleaning
2. This appliance should not be cleaned with a water jet or
immersed in water. Use only a damp cloth or sponge dipped in
soapy water.
3. Wipe o the unit with a dry cloth and wait at least half an hour
before re – connecting to the mains outlet.
THIS APPLIANCE SHOULD NOT BE CLEANED WITH
A WATER JET OR IMMERSED IN WATER. USE ONLY
A DAMP CLOTH OR SPONGE DIPPED IN SOAPY
WATER. DO NOT USE STEEL-WOOL WHICH WILL
MARK THE BRIGHT STAINLESS STEEL FINISH
29
SAFETY
WARNING
Electric Shock Hazard.
Keep water and other liquids from entering the inside
of the equipment. Liquid inside the equipment could
cause an electrical shock
Do not spray water or cleaning products. Liquid could contact the
electrical components and cause a short circuit or an electrical shock.
Do not use equipment if power cord is damaged or has been modied
1. When this appliance is to be positioned in close proximity
to a wall, partitions, kitchen furniture, decorative nishes, etc.
it is recommended that they be made of non-combustible
material. If not, they shall be clad with a suitable
non-combustible
heat insulating material, and the closest attention be paid to re
prevention regulations.
2. Use the appliance on an individual 15A mains outlet only.
DO NOT OVERLOAD THE CIRCUIT.
3. Ensure that the equipment and the power supply cord does not
come into contact with hot surfaces.
4. Supervision is necessary when the appliance is used in close
proximity to children.
5. If the supply cord is damaged, it must be replaced with a new
cord assembly available from the suppliers agent.
6. Use only earthed outlets matching the serial plate voltage.
7. Have equipment installed by a qualied personnel in accordance
with local codes and ordinances.
8. Use equipment in a at level position.
9. Do not operate unattended
10. The equipment may be hot, even though the pilot light is not on.
11. Do not operate if equipment has been damaged or is
malfunctioning in any way.
12. These appliances are designed to run only on alternating current
(A.C.) DO NOT CONNECT TO DIRECT CURRENT (D.C)
READ ALL INSTRUCTIONS BEFORE USE. FAILURE TO
FOLLOW THESE PRECAUTIONS COULD RESULT IN INJURY TO
YOURSELF AND OTHERS
3 8
Part
SCE BCE
No.
Part No. Part No.
1 BODY COMPLETE
2 4-BEZ-POA0001 BEZEL 1-6
3 3-KNOB-LEVER LEVER KNOB
4 4-DL-L-APEX APEX DOMED LABEL
5 1-EGO-50 THERMOSTAT
6 10-SR-POA01-L-1 LEFT SHELF RUNNER
7 82-PO-SS-DRASS DOOR HANDLE ASSEMBLY
8 10-GLA-POA0001 XPOA0002 PROVER GLASS DOORS
9 7-HINGE-CGA0008 GLASS DOOR HINGE
10 10-SR-POA01-R-1 RIGHT SHELF RUNNER
11 82-PO-SS-DTRAY DRIP TRAY
12 7-FOOT-FTA7016 PROVER ADJUSTABLE FEET
13 5-750W-SMOKER ELEMENT
14 3-CG-1.5 CABLE GRIP
15 2-PC-CE-CP POWER CORD
16 3-FF-CB TERMINAL BLOCK
17 4-BEZ-BADGE BADGE BEZEL
Description
MODEL:PROOFER OVEN
MODEL CODE : POA0001 R02
POSITIONING DIAGRAM
PROOFING CABINET
MODEL: POA0001 R02
860mm
995mm
591mm
4
EXPLODED DIAGRAM
PROOFING CABINET
MODEL: POA0001 R02
7
1
2
5
3
4
6
78
9
10
11
12
13
14
15
16
17
LEGEND DESCRIPTION PART NUMBER
B1 CONTROL THERMOSTAT 1-EGO-50
E1 230V/750W ELEMENT 5-750W-SMOKER
H1 PILOT LIGHT 1-PL-BMA0001
WIRING DIAGRAM
PROOFING CABINET
MODEL CODE: POA0001 R02
230V
H1
E1
E
N
L
B1
LEGEND DESCRIPTION PART NUMBER
B1 CONTROL THERMOSTAT 1-EGO-50
E1 230V/750W ELEMENT 5-750W-SMOKER
H1 PILOT LIGHT 1-PL-BMA0001
WIRING DIAGRAM
PROOFING CABINET
MODEL CODE: POA0001 R02
5
MODEL DESCRIPTION VOLTS
(V/Hz)
POWER
(W)
POA0001 PROOFING CABINET 230/60 750
IT IS ESSENTIAL TO MAKE SURE THAT THE INCOMING
VOLTAGE IS THE SAME AS THE RATED VOLTAGE OF
THE OF THE UNIT AS FOUND ON THE SERIAL PLATE.
THE SERIAL PLATE IS LOCATED AT THE REAR OF THE
UNIT ADJACENT TO THE INCOMING CABLE ENTRY.
6
/