2 – Battery management system UPS / Rev.A 0.1
1. General
1.1 Document information
The UPS battery management systems are to be exclusively
used for the control of compatible drives and control systems
in dry areas.
The UPS battery management systems may only be used to
power equipment that do not exceed the manufacturer’s
given maximum values.
The installer and the user must ensure that all applicable
legal and ofcial requirements regarding the use of the
products, in particular the current EMC guideline concerning
installation and operation, are observed.
1.2 Installation
Information:
− The mains cable must not be exchanged with the output
cable.
− The neutral conductor (N) and the outer conductor (L)
on the input side must not be connected to the neutral
conductor (N) and the outer conductor (L) on the output
side.
− For three-phase current, a clockwise rotating eld is
required.
− The cable for the door control must always be 3-wire or
5-wire at 1x230 or 3x400V.
Connection:
☞ Plug the supply line (A) into the socket of the on-site power
supply.
☞ Plug the control system’s supply line into the appropriate
socket (B)
☞ Switch the battery management system to the ON position
with the key switch (C)
☞ Fix the casing with plugs and screws in the desired position.
The mounting holes are located in the back wall of the
cabinet.
Meaning of signals and buttons:
BAT / POWER = battery OK
ON = battery management system is switched on
UPS = battery operation mode (power failure)
ON = switch on
OFF = switch off
REFERENCE
All technical data can be found in the separate data sheets.