H3C S5130S-10MS-UPWR-EI User manual

Category
Network switches
Type
User manual
i
Contents
Preparing for installation ················································································ 1
Safety recommendations ··································································································································· 3
Examining the installation site ···························································································································· 3
Temperature/humidity ································································································································ 3
Cleanliness ················································································································································· 3
EMI ····························································································································································· 4
Laser safety ················································································································································ 4
Installation tools ················································································································································· 5
Installing the switch ························································································ 6
Installing the switch in a 19-inch rack················································································································· 6
Mounting brackets ······································································································································ 6
Attaching the mounting brackets to the switch ··························································································· 8
Rack-mounting the switch ························································································································ 10
Mounting the switch on a workbench ··············································································································· 11
Mounting the switch on a wall ·························································································································· 12
Grounding the switch ······································································································································· 13
Grounding the switch with a grounding strip ···························································································· 14
Grounding the switch with a grounding conductor buried in the earth ground ········································· 15
Installing and removing power modules ··········································································································· 15
Installing a power module ························································································································ 16
Removing a power module ······················································································································ 17
Connecting the power cord ······························································································································ 17
Connecting the AC power cord for the fixed AC power module (method 1) ············································ 18
Connecting the AC power cord for the fixed AC power module (method 2) ············································ 19
Connecting the DC power cord for the fixed DC power module (method 1) ············································ 20
Connecting the DC power cord for the fixed DC power module (method 2) ············································ 21
Connecting the power cord for a PSR75-12A/PSR150-A1 power module ·············································· 22
Connecting the power cord for a PSR150-D1 power module ·································································· 23
Verifying the installation ··································································································································· 24
Accessing the switch for the first time ·························································· 25
Setting up the configuration environment ········································································································ 25
Connecting the serial console cable ················································································································ 26
Connecting the micro USB console cable ········································································································ 27
Setting terminal parameters ····························································································································· 29
Powering on the switch ···································································································································· 29
Setting up an IRF fabric ··············································································· 30
IRF fabric setup flowchart ································································································································ 30
Planning IRF fabric setup ································································································································· 31
Planning IRF fabric size and the installation site ······················································································ 31
Identifying the master switch and planning IRF member IDs ··································································· 31
Planning IRF topology and connections··································································································· 31
Identifying IRF physical ports on the member switches ··········································································· 32
Planning the cabling scheme ··················································································································· 34
Configuring basic IRF settings ························································································································· 35
Connecting the IRF physical ports ··················································································································· 35
Verifying the IRF fabric setup ··························································································································· 36
Maintenance and troubleshooting ································································ 37
Fixed power module failure ······························································································································ 37
Symptom ·················································································································································· 37
Solution ···················································································································································· 37
Removable power module failure ···················································································································· 38
Symptom ·················································································································································· 38
Solution ···················································································································································· 38
ii
Fan tray failure ················································································································································· 38
Symptom ·················································································································································· 38
Solution ···················································································································································· 38
Configuration terminal issues ··························································································································· 38
No display on the configuration terminal ·································································································· 38
Garbled display on the configuration terminal ·························································································· 39
Appendix A Chassis views and technical specifications ······························· 40
Chassis views ·················································································································································· 40
S5130S-10P-EI ········································································································································ 40
S5130S-12TP-EI ······································································································································ 41
S5130S-20P-EI ········································································································································ 41
S5130S-28P-EI/S5130S-28P-EI-M ·········································································································· 42
S5130S-28TP-EI ······································································································································ 43
S5130S-52P-EI/S5130S-52P-EI-M ·········································································································· 43
S5130S-52TP-EI ······································································································································ 44
S5130S-28S-EI/S5130S-28S-EI-M ·········································································································· 45
S5130S-52S-EI/S5130S-52S-EI-M ·········································································································· 45
S5130S-28F-EI ········································································································································ 46
S5130S-52F-EI ········································································································································ 47
S5130S-28MP-EI ····································································································································· 48
S5130S-52MP-EI ····································································································································· 49
S5130S-28PS-EI ······································································································································ 50
S5130S-28ST-EI ······································································································································ 51
S5130S-52ST-EI ······································································································································ 51
S5130S-10P-HPWR-EI ···························································································································· 52
S5130S-12TP-HPWR-EI ·························································································································· 53
S5130S-20P-PWR-EI ······························································································································· 53
S5130S-28P-PWR-EI ······························································································································· 54
S5130S-28P-HPWR-EI ···························································································································· 55
S5130S-52P-PWR-EI ······························································································································· 56
S5130S-16S-PWR-EI ······························································································································· 56
S5130S-28S-PWR-EI ······························································································································· 57
S5130S-28S-HPWR-EI ···························································································································· 58
S5130S-28S-HPWR-EI-Q ························································································································ 58
S5130S-52S-PWR-EI ······························································································································· 59
S5130S-28MP-HPWR-EI ························································································································· 60
S5130S-10MS-UPWR-EI ························································································································· 61
S5130S-28ST-PWR-EI ···························································································································· 62
S5130S-52ST-PWR-EI ···························································································································· 63
Technical specifications ··································································································································· 63
Appendix B FRUs ························································································ 76
Appendix C Ports and LEDs ········································································ 76
Ports ································································································································································· 76
Console port ············································································································································· 76
Management Ethernet port ······················································································································ 77
10/100/1000BASE-T autosensing Ethernet port ······················································································ 78
5G/2.5G/1000BASE-T autosensing Ethernet port ··················································································· 78
2.5G/1000/100BASE-T autosensing Ethernet port ·················································································· 78
10/5/2.5/1GBASE-T autosensing Ethernet port ······················································································· 79
SFP port ··················································································································································· 79
SFP+ port ················································································································································· 83
Combo interface ······································································································································· 85
LEDs ································································································································································ 85
System status LED ··································································································································· 85
Management Ethernet port LED ·············································································································· 86
Power module status LED ························································································································ 86
RPS status LED ······································································································································· 86
Mode LED (MODE) ·································································································································· 87
SFP/SFP+ port LED ································································································································· 87
iii
Ethernet port LEDs ··································································································································· 87
1
Preparing for installation
The S5130S-EI switch series includes the following models:
Model Product ID
Non-PoE switch models
S5130S-10P-EI
LS-5130S-10P-EI
LS-5130S-10P-EI-GL
S5130S-12TP-EI
LS-5130S-12TP-EI
LS-5130S-12TP-EI-GL
S5130S-20P-EI
LS-5130S-20P-EI
LS-5130S-20P-EI-GL
S5130S-28P-EI
LS-5130S-28P-EI
LS-5130S-28P-EI-GL
S5130S-28P-EI-M LS-5130S-28P-EI-M
S5130S-28TP-EI
LS-5130S-28TP-EI
LS-5130S-28TP-EI-GL
S5130S-52P-EI
LS-5130S-52P-EI
LS-5130S-52P-EI-GL
S5130S-52P-EI-M LS-5130S-52P-EI-M
S5130S-52TP-EI
LS-5130S-52TP-EI
LS-5130S-52TP-EI-GL
S5130S-28S-EI
LS-5130S-28S-EI
LS-5130S-28S-EI-GL
S5130S-28S-EI-M LS-5130S-28S-EI-M
S5130S-52S-EI
LS-5130S-52S-EI
LS-5130S-52S-EI-GL
S5130S-52S-EI-M LS-5130S-52S-EI-M
S5130S-28F-EI
LS-5130S-28F-EI
LS-5130S-28F-EI-GL
S5130S-52F-EI
LS-5130S-52F-EI
LS-5130S-52F-EI-GL
S5130S-28MP-EI
LS-5130S-28MP-EI
LS-5130S-28MP-EI-GL
S5130S-52MP-EI
LS-5130S-52MP-EI
LS-5130S-52MP-EI-GL
S5130S-28PS-EI LS-5130S-28PS-EI
S5130S-28ST-EI
LS-5130S-28ST-EI
LS-5130S-28ST-EI-GL
2
Model Product ID
S5130S-52ST-EI
LS-5130S-52ST-EI
LS-5130S-52ST-EI-GL
PoE switch models
S5130S-10P-HPWR-EI
LS-5130S-10P-HPWR-EI
LS-5130S-10P-HPWR-EI-GL
S5130S-12TP-HPWR-EI
LS-5130S-12TP-HPWR-EI
LS-5130S-12TP-HPWR-EI-GL
S5130S-20P-PWR-EI
LS-5130S-20P-PWR-EI
LS-5130S-20P-PWR-EI-GL
S5130S-28P-PWR-EI
LS-5130S-28P-PWR-EI
LS-5130S-28P-PWR-EI-GL
S5130S-28P-HPWR-EI
LS-5130S-28P-HPWR-EI
LS-5130S-28P-HPWR-EI-GL
S5130S-52P-PWR-EI
LS-5130S-52P-PWR-EI
LS-5130S-52P-PWR-EI-GL
S5130S-16S-PWR-EI
LS-5130S-16S-PWR-EI
LS-5130S-16S-PWR-EI-GL
S5130S-28S-PWR-EI
LS-5130S-28S-PWR-EI
LS-5130S-28S-PWR-EI-GL
S5130S-28S-HPWR-EI
LS-5130S-28S-HPWR-EI
LS-5130S-28S-HPWR-EI-GL
S5130S-28S-HPWR-EI-Q LS-5130S-28S-HPWR-EI-Q
S5130S-52S-PWR-EI
LS-5130S-52S-PWR-EI
LS-5130S-52S-PWR-EI-GL
S5130S-28MP-HPWR-EI
LS-5130S-28MP-HPWR-EI
LS-5130S-28MP-HPWR-EI-GL
S5130S-10MS-UPWR-EI
LS-5130S-10MS-UPWR-EI
LS-5130S-10MS-UPWR-EI-GL
S5130S-28ST-PWR-EI
LS-5130S-28ST-PWR-EI
LS-5130S-28ST-PWR-EI-GL
S5130S-52ST-PWR-EI
LS-5130S-52ST-PWR-EI
LS-5130S-52ST-PWR-EI-GL
NOTE:
The available chassis models and
accessories vary by country and region.
This document describes
only the preceding models. For the
chassis models and accessories available in your country or
region, contact the local H3C marketing personnel.
3
Safety recommendations
To avoid equipment damage or bodily injury, read the following safety recommendations before
installation. Note that the recommendations do not cover every possible hazardous condition.
•
Before cleaning the switch, remove all power cords from the switch. Do not clean the switch
with wet cloth or liquid.
•
Do not place the switch near water or in a damp environment. Prevent water or moisture from
entering the switch chassis.
•
Do not place the switch on an unstable case or desk.
•
Ensure good ventilation at the installation site and keep the air inlet and outlet vents of the
switch free of obstruction.
•
Connect the yellow-green protection grounding cable before power-on.
•
Make sure the power source voltage is as required.
•
To avoid electrical shocks, do not open the chassis while the switch is operating or when the
switch is just powered off.
•
To avoid ESD damage, wear an ESD wrist strap to hot-swap a power module.
Examining the installation site
The switch must be used indoors. You can mount your switch in a rack or on a workbench, but make
sure:
•
Adequate clearance is reserved at the air inlet and exhaust vents for ventilation.
•
The rack or workbench has a good ventilation system.
•
The rack is sturdy enough to support the switch and its accessories.
•
The rack or workbench is reliably grounded.
To ensure correct operation and long service life of your switch, install it in an environment that meets
the requirements described in the following subsections.
Temperature/humidity
Maintain temperature and humidity in the equipment room as described in "Technical specifications."
•
Lasting high relative humidity can cause poor insulation, electricity leakage, mechanical
property change of materials, and metal corrosion.
•
Lasting low relative humidity can cause washer contraction and ESD and cause problems
including loose mounting screws and circuit failure.
•
High temperature can accelerate the aging of insulation materials and significantly lower the
reliability and lifespan of the switch.
For the temperature and humidity requirements of different switch models, see "Appendix A Chassis
views and technical specifications."
Cleanliness
Dust buildup on the chassis might result in electrostatic adsorption, which causes poor contact of
metal components and contact points, especially when indoor relative humidity is low. In the worst
case, electrostatic adsorption can cause communication failure.
4
Table 1 Dust concentration limit in the equipment room
Substance Concentration limit (particles/m³)
Dust
≤ 3 x 10
4
(no visible dust on the tabletop over three days)
NOTE:
Dust diameter ≥ 5 μm
The equipment room must also meet strict limits on salts, acids, and sulfides to eliminate corrosion
and premature aging of components, as shown in Table 2.
Table 2 Harmful gas limits in the equipment room
Gas Maximum concentration (mg/m
3
)
SO
2
0.2
H
2
S 0.006
NH
3
0.05
Cl
2
0.01
EMI
All electromagnetic interference (EMI) sources, from outside or inside of the switch and application
system, adversely affect the switch in the following ways:
•
A conduction pattern of capacitance coupling.
•
Inductance coupling.
•
Electromagnetic wave radiation.
•
Common impedance (including the grounding system) coupling.
To prevent EMI, use the following guidelines:
•
If AC power is used, use a single-phase three-wire power receptacle with protective earth (PE)
to filter interference from the power grid.
•
Keep the switch far away from radio transmitting stations, radar stations, and high-frequency
devices to make sure the EMI levels do not exceed the compliant range.
•
Use electromagnetic shielding when necessary. For example, use shielded interface cables.
•
To prevent signal ports from getting damaged by overvoltage or overcurrent caused by lightning
strikes, only route interface cables indoors.
Laser safety
WARNING!
Disconnected optical fibers or
transceiver modules might emit invisible laser light. Do not stare into
beams or view directly with optical instruments when the switch is operating.
The switch is a Class 1 laser device.
5
Installation tools
No installation tools are provided with the switch. Prepare the following tools yourself as required.
•
Flat-blade screwdriver
•
Phillips screwdriver
•
ESD wrist strap
•
Needle-nose pliers
•
Diagonal pliers
•
Crimping tool
•
Marker
•
Heat gun
6
Installing the switch
CAUTION:
Keep the tamper
-
proof seal on a mounting screw on the chassis cover intact, and if you want to open
the chassis, contact H3C for permission. Otherwise, H3C shall not be liable for any consequence.
Figure 1 Hardware installation flow
Installing the switch in a 19-inch rack
Mounting brackets
Table 3 describes the mounting brackets applicable to the switch.
Ground the switch
Install the switch
Start
Connect power cords
Verify the installation
Turn on the circuit breakers
Select and install power
modules
Hot-swap power
modules?
Yes
No
Operating correctly?
Turn off the circuit
breakers
Troubleshoot the switch
No
Yes
End
Install interface connectors
and cables
7
Table 3 Mounting brackets applicable to the switch
Switch model Mounting brackets Views
S5130S-28P-EI
S5130S-28P-EI-M
S5130S-28TP-EI
S5130S-52P-EI
S5130S-52P-EI-M
S5130S-52TP-EI
S5130S-28S-EI
S5130S-28S-EI-M
S5130S-52S-EI
S5130S-52S-EI-M
S5130S-28P-PWR-EI
S5130S-28P-HPWR-EI
S5130S-52P-PWR-EI
S5130S-28S-PWR-EI
S5130S-28S-HPWR-EI
S5130S-28S-HPWR-EI-Q
S5130S-52S-PWR-EI
S5130S-28MP-EI
S5130S-28MP-HPWR-EI
S5130S-52MP-EI
Mounting brackets A (provided) See A in Figure 2.
S5130S-28F-EI
S5130S-52F-EI
S5130S-28PS-EI
S5130S-28ST-EI
S5130S-52ST-EI
S5130S-28ST-PWR-EI
S5130S-52ST-PWR-EI
Mounting brackets B (provided) See B in Figure 2.
S5130S-20P-EI
S5130S-10P-HPWR-EI
S5130S-12TP-HPWR-EI
S5130S-20P-PWR-EI
Mounting brackets C with product code
SOHO-SWITCH-FL-02
(optional)
See C in Figure 2.
S5130S-16S-PWR-EI
S5130S-10MS-UPWR-EI
Mounting brackets D with product code
LS5-FL-D
(optional)
See D in Figure 2.
S5130S-10P-EI
S5130S-12TP-EI
Mounting brackets E with product code
SOHO-SWITCH-FL-01
(optional)
See E in Figure 2.
8
Figure 2 Mounting brackets
(1) Screw hole for attaching the bracket to the switch
(2 ) Screw hole for attaching the bracket to the rack post
Attaching the mounting brackets to the switch
1. Determine the installation position for the mounting brackets.
ï‚¡ The S5130S-28F-EI, S5130S-52F-EI, S5130S-28PS-EI, S5130S-28ST-PWR-EI, and
S5130S-52ST-PWR-EI switches provide two installation positions for the mounting brackets:
port side mounting position and power module side mounting position.
ï‚¡ The other S5130S-EI switches provide only the port side mounting position for the mounting
brackets.
2. Align one mounting bracket with the screw holes at the mounting position. Use M4 screws to
attach the mounting bracket to the chassis. See Figure 3 for installing mounting bracket A,
Figure 4 and Figure 5 for installing mounting bracket B, and Figure 6 for installing mounting
bracket C, D, and E (C as an example).
M4 screws are provided only for switches shipped with mounting brackets.
An optional mounting bracket kit contains M4 screws.
1
2
(C)
1
2
(E)
(
D)
1
2
1
2
(B)
1
2
(A)
9
3. Repeat step 2 to attach the other mounting bracket to the chassis.
Figure 3 Attaching mounting bracket A (S5130S-28P-HPWR-EI switch)
Figure 4 Attaching mounting bracket B to the port side mounting position (S5130S-52F-EI
switch)
Figure 5 Attaching mounting bracket B to the power module side mounting position
(S5130S-52F-EI switch)
10
Figure 6 Attaching mounting bracket C (S5130S-20P-PWR-EI switch)
Rack-mounting the switch
This task requires two people. To mount the switch in the rack:
1. Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2. Verify that the mounting brackets have been securely attached to the switch chassis.
3. Install cage nuts in the mounting holes in the rack posts.
No cage nuts are provided with the switch. Prepare them yourself.
4. One person holds the switch chassis and aligns the mounting brackets with the mounting holes
in the rack posts, and the other person attaches the mounting brackets to the rack with M6
screws.
M6 screws are provided only for switches shipped with mounting brackets. For switches not
shipped with mounting brackets, prepare M6 screws yourself.
5. Verify that the switch chassis is horizontal and secure.
Figure 7 Mounting an S5130S-52F-EI switch in the rack (port side mounting position for the
mounting brackets)
11
Figure 8 Mounting an S5130S-52F-EI switch in the rack (power module side mounting
position for the mounting brackets)
Figure 9 Mounting an S5130S-20P-PWR-EI switch in the rack
Mounting the switch on a workbench
IMPORTANT:
•
Ensure 10 cm (3.9 in) of clearance around the chassis for heat dissipation.
• Do not place heavy objects on the switch.
If a standard 19-inch rack is not available, you can place you switch on a workbench.
To mount the switch on a workbench:
1. Verify that the workbench is sturdy and reliably grounded.
2. Place the switch with bottom up, and clean the round holes in the chassis bottom with dry cloth.
3. Attach the rubber feet to the four round holes in the chassis bottom.
4. Place the switch with upside up on the workbench.
12
Mounting the switch on a wall
CAUTION:
•
Before drilling holes in a wall, make sure no electrical lines exist in the wall.
• Leave a minimum clearance of 10 mm (0.39 in) around the chassis for heat dissipation.
Table 4 describes the switch models that support wall mounting and installation holes distances
required for wall-mounting the switch. Screw anchors and screws as shown in Figure 10 are
provided with these switches for wall-mounting.
Table 4 Installation hole distances for switch models that support wall mounting
Switch model Hole distance
S5130S-10P-EI
S5130S-12TP-EI
170 mm (6.69 in)
S5130S-20P-EI 176 mm (6.93 in)
S5130S-10P-HPWR-EI
S5130S-12TP-HPWR-EI
S5130S-16S-PWR-EI
S5130S-10MS-UPWR-EI
102 mm (4.02 in)
S5130S-20P-PWR-EI 116 mm (4.57 in)
Figure 10 Screw anchor and screw
To mount the switch on a wall:
1. Mark two installation holes on the wall. Make sure the two holes are on the same horizontal line.
See Table 4 for the distance requirement between the two holes.
Figure 11 Installing the switch on a wall (1)
13
2. Drill two holes with a diameter of 6 mm (0.24 in) (7 mm/0.28 in for an S5130S-16S-PWR-EI
switch) and a depth of 25 mm (0.98 in) at the marked locations. Hammer the screw anchors into
the wall and use a Phillips screwdriver to fasten the screw into the screw anchor. Leave 1.5 mm
(0.06 in) between the screw head and the wall for hanging the switch.
Figure 12 Installing the switch on a wall (2)
3. Align the installation holes in the switch rear with the screws on the wall and hang the switch on
the screws. Make sure the port side faces down and the left and right sides are perpendicular to
the ground.
Figure 13 Installing the switch on a wall (3)
Grounding the switch
WARNING
!
Correctly connecting the switch grounding cable is crucial to lightning protection and EMI protection.
The power input end of the switch has a noise filter, whose central ground is directly connected to the
chassis to form the chassis ground (commonly known as PGND). You must securely connect this
chassis ground to the earth to minimize the potential for system damage, maximize the safety at the
site, and minimize EMI susceptibility of the system.
You can ground the switch in one of the following ways, depending on the grounding conditions
available at the installation site:
•
Grounding the switch with a grounding strip
•
Grounding the switch with a grounding conductor buried in the earth ground
NOTE:
The
chassis views and power module and grounding terminal positions in the following figures are
for illustration only.
14
Grounding the switch with a grounding strip
WARNING
!
Connect the grounding cable to the grounding system in the equipment room. Do not connect it to a
fire main or lightning rod.
If a grounding strip is available at the installation site, use the grounding strip to ground the switch.
To ground the switch by using a grounding strip:
1. Attach the ring terminal end of the grounding cable to the grounding hole in the switch.
a. Remove the grounding screw from the grounding hole in the rear panel of the switch.
b. Attach the grounding screw to the ring terminal of the grounding cable.
c. Use a screwdriver to fasten the grounding screw into the grounding screw hole.
Figure 14 Attaching the grounding cable to the grounding hole of the switch
(S5130S-28P-HPWR-EI switch)
(1) Grounding screw
(3) Grounding sign
(5) Grounding cable
2. Connect the other end of the grounding cable to the grounding strip.
a. Cut the grounding cable to a length according to the distance between the switch and the
grounding strip.
b. Peel 20 mm (0.79 in) of insulation sheath by using a wire stripper.
c. Use the needle-nose pliers to bend the bare wire.
d. Hook the grounding cable to the post on the grounding strip, and use the hex nut to secure
the cable to the post.
5
1
2
3
4
15
Figure 15 Connecting the grounding cable to a grounding strip
(1) Grounding post
(2) Grounding strip
(3) Grounding cable
(4) Hex nut
Grounding the switch with a grounding conductor buried in
the earth ground
If the installation site has no grounding strips, but earth ground is available, hammer a 0.5 m (1.64 ft)
or longer angle iron or steel tube into the earth ground to serve as a grounding conductor.
The dimensions of the angle iron must be at least 50 × 50 × 5 mm (1.97 × 1.97 × 0.20 in). The steel
tube must be zinc-coated and its wall thickness must be at least 3.5 mm (0.14 in).
Weld the yellow-green grounding cable to the angel iron or steel tube and treat the joint for corrosion
protection.
Figure 16 Grounding the switch by burying the grounding conductor into the earth ground
(1) Grounding screw
(2) Grounding cable
(3) Earth
(4) Joint
(5) Grounding conductor
(6) Chassis rear panel
Installing and removing power modules
CAUTION:
Provide a circuit breaker for each power
module and make sure the circuit breaker is off before
installation.
1 2
3
4
1
2
5
4
3
6
16
This section applies only to the switch models that support removable power modules.
The S5130S-28F-EI and S5130S-52F-EI switches each provide two power module slots. They come
with power module slot 1 empty and power module slot 2 installed with a filler panel. You can install
one power module, or two power modules for redundancy. For information about power modules
available for the S5130S-52F-EI switch, see "Appendix B FRUs."
When two power modules are installed, you can hot-swap a power module. To avoid device damage
and bodily injury, follow the procedures in Figure 17 and Figure 18 to install and replace a power
module.
Figure 17 Installation procedure
Figure 18 Removal procedure
The installation and removal procedures are the same for power modules. This guide uses the
PSR150-A1 power module as an example.
Installing a power module
1. Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2. Unpack the power module and verify that the power module model is as required.
3. Remove the filler panel (if any) from the target slot.
If you require only one power module, install it in power module slot 1 and make sure a filler
panel is installed in power module slot 2.
4. Orient the power module with the upside up. Grasp the handle of the power module with one
hand and support its bottom with the other, and slide the power module slowly along the guide
rails into the slot. See callout 1 in Figure 19.
To prevent damage to the power module and the connector on the switch backplane, insert the
power module gently. If you encounter a hard resistance or the power module tilts while
inserting the power module, pull out the power module, realign it with the slot, and then insert it
again.
5. Fasten the captive screws on the power module with a Phillips screwdriver to secure the power
module in the chassis. See callout 2 in Figure 19.
If the captive screw cannot be tightly fastened, examine the installation of the power module.
Figure 19 Installing a power module
Install the power
module
Connect the power
cord
Turn on the circuit
breaker
Turn off the circuit
breaker
Remove the power
cord
Remove the power
module
1
2
2
17
Removing a power module
1. Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2. Power off the power module and remove the power cord.
3. Loosen the captive screws on the power module with a Phillips screwdriver until they are
completely disengaged from the chassis.
4. Grasp the handle of the power module with one hand and pull the module part way out. Support
the module bottom with the other hand, and pull the power module slowly along the guide rails
out of the slot.
5. Place the removed power module in an antistatic bag.
Figure 20 Removing a power module
Connecting the power cord
CAUTION:
•
Provide a circuit breaker for each power cord.
• Before connecting the power cord, make sure the circuit breaker on the power cord is turned off.
Table 5 Power cord connection procedures at a glance
Switch model Available power source Connection procedure reference
S5130S-28P-HPWR-EI
S5130S-52P-PWR-EI
S5130S-28S-HPWR-EI
S5130S-52S-PWR-EI
S5130S-28MP-HPWR-EI
AC power source
Connecting the AC power cord for the fixed
AC power module (method 1)
H3C RPS1600-A
Connecting the DC power cord for the fixed
DC power module (method 1)
S5130S-10MS-UPWR-EI
AC power source
Connecting the AC power cord for the fixed
AC power module (method 2)
H3C RPS1600-A
Connecting the DC power cord for the fixed
DC power module (method 1)
1
2
1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91

H3C S5130S-10MS-UPWR-EI User manual

Category
Network switches
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI