  • Hello! I am an AI chatbot trained to assist you with the Zurn ZEMS6003-WS1-YB-YC Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
®
AquaSense AV
ZEMS-IS Motor Actuator
Replacement
®
Step 1- Shut off water, remove old ZEMS-IS actuator and
carefully unplug the power chord.
STEP 2 - Check voltage at power chord with voltmeter.
Voltage MUST be between 7.0 and 9.0 volts DC.
Step 3- Place escutcheon on new ZEMS-IS motor
actuator, connect wires at plug connector, then attach new
ZEMS-IS actuator to valve with gasket provided. Set
escutcheon against wall and tighten set screw. Turn on
water.
Step 4- Check actuator to ensure sensor is working. Hold
manila folder at edge of the toilet for 10 seconds. Remove
and actuator should flush valve.