Microh NEO WASH ZM60TS User manual

Category
Stroboscopes & disco lights
Type
User manual

Microh NEO WASH ZM60TS is a professional-grade wash light designed for a wide range of applications. With its powerful 4 x 15W 4-in-1 QUAD (RGBW) LEDs, the NEO WASH ZM60TS delivers a bright and even wash of color over a wide area. The fixture's 10° - 60° zoom range makes it suitable for both short-throw and long-throw applications, while its pan and tilt capabilities allow for precise positioning of the light beam.

The NEO WASH ZM60TS offers multiple control options, including DMX-512, master/slave, and sound activation. The fixture's built-in microphone allows for sound-to-light effects, while its 10-channel DMX mode provides detailed control over all of the fixture's parameters.

Microh NEO WASH ZM60TS is a professional-grade wash light designed for a wide range of applications. With its powerful 4 x 15W 4-in-1 QUAD (RGBW) LEDs, the NEO WASH ZM60TS delivers a bright and even wash of color over a wide area. The fixture's 10° - 60° zoom range makes it suitable for both short-throw and long-throw applications, while its pan and tilt capabilities allow for precise positioning of the light beam.

The NEO WASH ZM60TS offers multiple control options, including DMX-512, master/slave, and sound activation. The fixture's built-in microphone allows for sound-to-light effects, while its 10-channel DMX mode provides detailed control over all of the fixture's parameters.

USER MANUAL
Please read this user manual before using this product
Introduction
Thank you for purchasing the MICROH DJ NEO WASH ZM60TS. For your own
safety and knowledge, please read this manual before installing or operating
this device. This manual covers the important information on installation and
applications. Please install and operate the xture according to instructions.
Meanwhile, please keep this manual for future reference.
Please carefully unpack the xture and check all areas to see if it was damaged
during transportation. Please check whether the following items are included in
the package:
Item Quantity
NEO WASH ZM60TS xture 1
Power cord 1
DMX Cable 1
Bracket 1
User manual 1
Notify the shipper immediately and retain packing material for inspection if any parts
appear damaged from shipping or the carton itself shows signs of mishandling.
Save the carton and all packing materials. In the event that a xture must be
returned to the factory, it is important that the xture be returned in the original
factory box and packing.
Safety Warning
• Every person involved with the installation, operation and maintenance of this
device must be qualied.
• User/installer must follow the instructions of this manual.
• Unqualied persons must not open the housing cover and operate the device,
or the dealer will not accept liability for any resulting defects or problems.
• Protect the device against rain and moisture device with other electrical equipment.
• During move and installation, make sure the device is not stored with metal
parts and other tough materials.
• Always disconnect from the main power sources. Do not install or dismantle
when the device is powered on.
• The minimum distance between light output and the Illuminated surface must
be more than 50cm.
• The device must only be installed on a non-ammable surface. In order to
safeguard sufcient ventilation, please leave 50cm of free space around the
device. Note that heat-sensitive objects may be deformed or damaged by the
emitted heat of this xture.
• During operation, the housing may become very hot! Do not operate the device
for 15 minutes after switching off.
• The maximum ambient temperature Ta = 45°( must never be exceeded). The
maximum housing temperature Tb = 80°( must never be exceeded).
• This xture is for indoor use.
• Replace any visible cracked protective shields, lters, and lenses.
• The protective shields, lters, and lenses will require weekly cleaning as
smoke “cuid” tends to build up residues, reducing the light output very quickly.
CAUTION!
Never touch the device during operation!
The housing may heat up!
CAUTION!
Never look directly into light source,
as sensitive persons may suffer from an epileptic shock.
Caution!
• Unqualied person involved with installation, operation and maintenance of
this device is prohibited.
• If any of the above mentioned problems happen, or unknown problems happen,
please contact manufacturer or distributor for assistance.
Operation
Press the function key Menu cycled out of eight different functional effects, digital
tube in which the rst two digits represent the current function (see menu). The
last two digits represent the kinds of functions which the address code, or speed
parameters. Press Down or UP key to modify its parameter values. Press the Enter
key to conrm.
Level 01 Menu Level 02 Menu
Addr (DMX Address) 001-512
Chnd (Channel Mode)
10CH
12CH
15CH
Slnd (Master/Slave Mode)
Master
Slave 01
Slave 02
Shnd (Show Mode) Show 01 - Show 04
Auto (Auto-run Mode)
Non-automatic
Automatic
Soud (Sound Control) On - Off
Soen (sound Sensitivity) 000-100
Blac (Pause Mode)
Stop
Start Up
LED (Backlit) On - Off
Disp (Display Flip) disp-dsip
Pan (X-axis Flip) Yes - No
Tilt (Y-axis Flip) Yes - No
Level 01 Menu Level 02 Menu
Menu (Menu Test)
Pan
Tilt
Zoom
Red
Green
Blue
White
Dimmer
Strobe
Test (Automatic Test) Test
Rest Reset
Features
• Built-in Microphone
• Pan/Tilt Inversion
• 10° - 60° Wash Zoom
Specications
Lamp/LED Zoom 4 x 15W 4 in QUAD (RGBW) LED WASH
LED Life: 50,000 hrs
Voltage: 95V-240VAC, 50/60Hz
Power Consumption: 70W
Power Connection: IEC In
Data Connection: 3 Pin XLR
Wash Angle: 10° - 60°
Strobe Pulse: 0-12Hz
Pan: 540°
Tilt: 270°
Modes: Auto, DMX, Master/Slave, Sound
DMX Channels: 10CH/ 12CH/ 15CH
Dimensions (mm): 470 x 310 x 305
Weight: 2.7 Kg
Operation (cont.)
Mounting And Installing
Caution: for added protection, mount the xture in areas outside walking paths,
seating areas, or in areas were the xture might be reached by unauthorized
personnel. Before mounting the xture to any surface, make sure that the
installation area can hold a minimum point load of 10 times the devices weight.
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable. Never stand directly below the device when
mounting, removing, or servicing the xture.
Whether installing inverted on a truss or ceiling, or set on a at level surface be
sure this xture is kept at least 0.5m (1.5ft) away from any ammable materials
(decorations, etc.). Always use and install the supplied safety cable as a safety
measure to prevent accidental damage and/or injury in the event the clamp fails.
Mounting Points: Overhead mounting requires extensive experience, including
calculating working load limits. A knowledge of the installation material being
used, and periodic safety inspection of all installation material and the xture are
all imperative and should only be performed by a qualied technician. Improper
installation can result in bodily injury or damage.
Clamp Mounting: The MICROH DJ NEO WASH ZM60TS provides a unique
mounting bracket assembly that integrates 2 brackets to be used to mount on
a truss or the oor. When mounting this xture to truss, be sure to secure an
appropriately rated clamp to the included bracket tted through the center hole.
As an added safety measure, be sure to attach at least one properly rated safety
cable to the xture.
Regardless of the rigging option you choose for your MICROH DJ NEO WASH
ZM60TS xture, always be sure to secure your xture with a safety cable. The
xture provides a built-in rigging point for a safety cable hanging bracket. Be sure
to only use the designated rigging point for the safety cable and never secure a
safety cable to a carrying handle.
DMX -512 Control Connections
This xture complies with international USITT DMX standards and can be used
with a 3 pin DMX connector. Plug in the 3 pin XLR cable to the female 3 pin XLR
output of your controller and the other side to the male 3 pin XLR input of the
xture. To connect the units to DMX, you must daisy chain the xtures together
as a referred in the diagram below. Always end your DMX-512 connection with at
DMX terminator.
For installations where the DMX cable has to run for a long distance, or as an
electrically noisy environment, it is recommended to use a DMX terminator. This
helps in preventing corruption of the digital control signal by electrical noise. The
DMX terminator is simply an XLR plug with a 120 resistor connected between pins
two and three, which is then plugged into the output XLR socket of the last xture
in the chain.
DMX Modes
CH Mode
10CH 12CH 15CH Value Function
1 1 1 000-255 Pan (0-100%)
2 2 2 000-255 Tilt (0-100%)
3 3 3 000-255 Zoom (0-100%)
4 000-255 Pan/Tilt (fast to slow)
4 4 5 000-255 Red Dimmer (0-100%)
5 5 6 000-255 Green Dimmer (0-100%)
6 6 7 000-255 Blue Dimmer (0-100%)
7 7 8 000-255 White Dimmer (0-100%)
8 8 9 000-255 Master Dimmer (0-100%)
9 9 10
000-007 Close
008-015 Open
016-131 Strobe (slow to fast)
132-139 Open
140-181 Fast close to slow open
182-189 Open
190-231 Fast open to slow close
232-239 Open
240-247 Random Strobe
248-255 Open
10 11
000-007 No Function
008-011 Colour 01
012-015 Colour 02
016-019 Colour 03
020-022 Colour 04
023-026 Colour 05
027-030 Colour 06
031-034 Colour 07
035-037 Colour 08
038-041 Colour 09
042-045 Colour 10
046-048 Colour 11
049-052 Colour 12
053-056 Colour 13
057-060 Colour 14
10
(cont)
11
(cont)
061-063 Colour 15
064-067 Colour 16
068-071 Colour 17
072-075 Colour 18
076-078 Colour 19
079-082 Colour 20
083-086 Colour 21
087-089 Colour 22
090-093 Colour 23
094-097 Colour 24
098-101 Colour 25
102-104 Colour 26
105-108 Colour 27
109-112 Colour 28
113-115 Colour 29
116-119 Colour 30
120-123 Colour 31
124-127 Colour 32
128-131 Colour Macro 01
132-135 Colour Macro 02
136-139 Colour Macro 03
140-143 Colour Macro 04
144-147 Colour Macro 05
148-151 Colour Macro 06
152-155 Colour Macro 07
156-159 Colour Macro 08
160-163 Colour Macro 09
164-167 Colour Macro 10
168-171 Colour Macro 11
172-175 Colour Macro 12
176-179 Colour Macro 13
180-183 Colour Macro 14
184-187 Colour Macro 15
188-191 Colour Macro 16
192-195 Colour Fade Macro 01
196-199 Colour Fade Macro 02
200-203 Colour Fade Macro 03
10
(cont)
11
(cont)
204-207 Colour Fade Macro 04
208-211 Colour Fade Macro 05
212-215 Colour Fade Macro 06
216-219 Colour Fade Macro 07
220-223 Colour Fade Macro 08
224-227 Colour Fade Macro 09
228-231 Colour Fade Macro 10
232-235 Colour Fade Macro 11
236-239 Colour Fade Macro 12
240-243 Colour Fade Macro 13
244-247 Colour Fade Macro 14
248-251 Colour Fade Macro 15
252-255 Colour Fade Macro 16
11 12 000-255 Colour Macro Speed (slow to fast)
13
000-015 No function
016-035 Macro 01
036-055 Macro 02
056-075 Macro 03
076-095 Macro 04
096-115 Macro 05
116-135 Macro 06
136-155 Macro 07
156-175 Macro 08
176-195 Macro 09
196-215 Macro 10
216-235 Macro 11
236-255 Macro 12
14 000-255 Pan/Tilt Speed (slow to fast)
10 12 15
000-069 No function
070-079 When Pan/Tilt axis moving, shut the lights
080-179 No function
180-189 Auto Run
190-199 No function
200-209 Reset
210-255 No function
PLEASE NOTE:
All information for this product is subject to change without notice!
Maintenance and Cleaning
The following points have to be considered during the inspection:
1. All screws for installing the device, or parts of the device must be tightly
connected, and must not be corroded.
2. There must not be any deformations on the housing, colour lenses, xations or
installation spots (ceiling, suspension, trussing).
3. Mechanically moved parts must not show any traces of wearing and must not
rotate with unbalances.
4. The electric power supply cables must not show any damage, material fatigue
or sediments.
Further instructions depending on the installation spot and usage must be handled
by a skilled installer or technician. Any safety issues must be resolved.
CAUTION!
Disconnect xture before servicing.
In order to keep the xture in good condition and extend the life, we suggest regular
cleaning to the xture.
1. Clean the inside and outside lens each week or 100 operation hours to prevent
the light output from darkening due to accumulation of dust, dirt, etc.
2. Clean the fan each week or 100 operation hours.
3. A detailed electrical check by an approved technician every three months is
advised. Ensure the circuit contacts are in good condition, and prevent from
overheating.
We recommend a frequent cleaning of the device. Please use a moist, lint-free
cloth. Never use alcohol solvents.
There are no serviceable parts inside the device. Please refer to the instructions
under “Installation Instructions.”
Should you need any spare parts, please order genuine MICROH DJ parts from
your local dealer.
CAUTION!
Take care using this equipment! High voltage risk of electric shock!
For more information please contact:
www.microhdj.com
905.428.9062
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Microh NEO WASH ZM60TS User manual

Category
Stroboscopes & disco lights
Type
User manual

Microh NEO WASH ZM60TS is a professional-grade wash light designed for a wide range of applications. With its powerful 4 x 15W 4-in-1 QUAD (RGBW) LEDs, the NEO WASH ZM60TS delivers a bright and even wash of color over a wide area. The fixture's 10° - 60° zoom range makes it suitable for both short-throw and long-throw applications, while its pan and tilt capabilities allow for precise positioning of the light beam.

The NEO WASH ZM60TS offers multiple control options, including DMX-512, master/slave, and sound activation. The fixture's built-in microphone allows for sound-to-light effects, while its 10-channel DMX mode provides detailed control over all of the fixture's parameters.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI