Martin M2GO Installation guide

Type
Installation guide

This manual is also suitable for

www.martin.com Olof Palmes Allé 18 DK-8200 Aarhus N • Denmark
Tel. (+45) 8740 0000 • Fax (+45) 8740 0010
Martin M2GO™ / M2PC™
Firmware Installation Guide
Introduction
This document will guide you through the firmware update procedure for the Martin M2GO /
M2PC console.
When is it needed?
It is vital that the firmware is always up to date to the current M-Series software that is running
on your console. Not every M-Series software upgrade requires an additional firmware update
though. Please do not perform the firmware update during show time, as it stops running
services in the software and requires a reboot of the console.
www.martin.com Olof Palmes Allé 18 DK-8200 Aarhus N • Denmark
Tel. (+45) 8740 0000 • Fax (+45) 8740 0010
General firmware upgrade procedure
If new firmware is available, it will be copied in a folder on the solid state drive of your console
when the M-series software is being installed.
Installing new firmware will not delete any of your current or backed up show files on the
console. Nevertheless, it’s always a good idea to have copies of important show files.
Starting up the Firmware Update tool
Start up your console and load/continue a show
Go into the menu, select the System tab and go to the Tools section
In the bottom of the page, select the Diagnostic tab
In the Tools section, click on Firmware update
A popup saying that all services are being stopped, will show up and the Firmware
update tool is started
www.martin.com Olof Palmes Allé 18 DK-8200 Aarhus N • Denmark
Tel. (+45) 8740 0000 • Fax (+45) 8740 0010
Exploring the Firmware Update tool
There are two types of firmware that you might need to
update: USB firmware and IIC (I²C) firmware. The tool
has 3 main windows.
USB devices: Shows all detected USB devices
IIC devices: Shows all detected IIC devices
connected to the selected USB device in the
window above
Lower window: Shows the status of the
Firmware tool
Matching firmware name and device ID
To choose the correct firmware for the selected device, make sure that the firmware name and
device ID match. For example:
F100 Mx Programmer Module” = (F100) Programmer Module II (x.xx) USB.C2
70h F080h Digital Belt 01h 200h” = (70-F080-01) 4x DigiBelt (V3.40) IIC.hex
Selecting USB firmware
Select a USB device in the first window
Click on the Update USB Firmware button
A file browser opens. Select the folder of the product that the module belongs to.
Select the correct firmware file with *.C2 extension: look at the identifier in the tool and in
the folder and make sure they match. In this case F100.
Check if an update is needed by checking the version. In this case is v02.50 active and
in the folder is V3.40 so an upgrade is needed.
www.martin.com Olof Palmes Allé 18 DK-8200 Aarhus N • Denmark
Tel. (+45) 8740 0000 • Fax (+45) 8740 0010
Updating USB firmware
If you want to update the firmware or import the same version, click on the Open button
A popup will be seen that the current version is the same as the file version. Click Yes to
continue
The firmware is now being transferred to the PCB. Do not cut the power! Please note the
status window and progress bar
Don’t worry if the tool says (Not Responding). It will take a few seconds. Please wait.
The tool will verify the update and the result is shown in the status window
Repeat all the above steps for each USB device in the list
In the case below the same version v02.50 is being installed and a warning is given
www.martin.com Olof Palmes Allé 18 DK-8200 Aarhus N • Denmark
Tel. (+45) 8740 0000 • Fax (+45) 8740 0010
Selecting IIC firmware
Select a USB device in the first window
The tool will now scan for existing IIC devices on that particular USB device
After a few seconds the results are shown in the IIC devices window
Select a IIC device in the second window
Click on the Update IIC Firmware button
A browser window opens. Select the folder of the product that the module belongs to.
Select the correct firmware file with *.HEX extension: look at the identifier in the tool and
in the folder and make sure they match. In this case 70-F080-01.
Check if an update is needed by checking the version. In this case 0200h is active and
in the folder is V3.40 so an upgrade is needed.
www.martin.com Olof Palmes Allé 18 DK-8200 Aarhus N • Denmark
Tel. (+45) 8740 0000 • Fax (+45) 8740 0010
Updating IIC firmware
If you want to update the firmware or import the same version, click on the Open button
A popup will be seen that the current version is the same as the file version. Click Yes to
continue
The firmware is now being transferred to the PCB. Do not cut the power! Please note the
status window and progress bar
Don’t worry if the tool says (Not Responding). It will take a few seconds. Please wait.
The tool will verify the update and the result is shown in the status window
Repeat all the above steps for each IIC device in the list
Do not forget to check the IIC devices of the other USB devices by selecting the next
USB device in the first window
In the case below the same version v02.00 is being installed and a warning is given
Completing installation
The firmware update is complete after a full restart of the console. A popup will be shown when
closing down the Firmware update tool to execute the reboot.
www.martin.com Olof Palmes Allé 18 DK-8200 Aarhus N • Denmark
Tel. (+45) 8740 0000 • Fax (+45) 8740 0010
Instructions for M2GO / M2PC Console Version 3.52
Start up your console and load/continue a show
Start up the Firmware Update tool
Select the USB device row in the top of the window, then install every firmware one by one with
the correct files as shown below. Check them off in the right column to keep track of completed
items.
USB Firmware
Check
(F0AA) USB-DMX (V3.42) USB.C2 DIPS 77
www.martin.com Olof Palmes Allé 18 DK-8200 Aarhus N • Denmark
Tel. (+45) 8740 0000 • Fax (+45) 8740 0010
USB Firmware
Check
(F111) M2Go-PC Main Panel (V3.40) USB.C2
IIC Firmware
Check
(30-F111-11) M2GO-PC Programmer (V3.40) IIC.hex
(70-F111-11) M2GO-PC Encoders (V3.40) IIC.hex
(C0-F111-11) M2GO-PC Playbacks (V3.40) IIC.hex
www.martin.com Olof Palmes Allé 18 DK-8200 Aarhus N • Denmark
Tel. (+45) 8740 0000 • Fax (+45) 8740 0010
The firmware update is complete after a full restart of the console. A popup will be
shown when closing down the tool to execute the reboot.
Final Test
After reboot, open the firmware tool again and confirm all entries to match the checklist.
Close the firmware tool and open the console test application in the same menu screen and test
all buttons, faders and encoders for operation. Close the console tester once completed.
Test every DMX line for operation with a DMX tester or a lighting fixture to confirm operation.
Revision
Made by
Description
Approved by
718
Kris Van
Hullebusch
Updated for M-Series v3.52
Chris Foblets
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Martin M2GO Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI