Fadini Elpro 10F Owner's manual

Type
Owner's manual
Drwg. No. 3339
GB
ELECTRONIC PROGRAMMER
FOR SLIDING GATES. PEDESTRIAN OPENING.
HOLD ON SWITCHED CONTROL AND
ELECTRONIC BRAKE.
Elpro 10 F
SLIDING GATES
THREE-PHASE / SINGLE-PHASE
N.W.: should more pairs of photocells be required than the
recommended quantity, fit an auxiliary transformer outside the
control box.
N.W.:
for special application, ie. to switch on lights - CCTV etc...,
SOLID STATE RELAYS are recommended to be used only. Standard
relays would affect the micro-processor.
N.W.:
THIS PANEL IS TESTED TO OPERATE GATES ONLY THROUGH
FADINI ACCESSORIES, NO GUARANTEE FOR ACCESSORIES OF OTHER
MAKE OR SPECIAL APPLICATIONS.
37
ALL OPERA
TIONS
OPEN, CLOSE &
REVERSE
RADIO CONTACT
26
27
28
TERMINALS FOR THE
CONNECTION OF THE
PUSH BUTTONS PULIN 3
RADIO CONTROL
PLUG-IN CARD SUPPORT
24V OUTPUT
1
st
CHANNEL
OPEN
CLOSE MAINS
1A
FUSE
LOGIC CARD
5A
FUSES
HIGH VOLTAGE
EARTH
CONNECTION
24V OUTPUT max permitted load:
2 pairs photocells
1 radio receiver
24V INDICATOR - 3W max
1
74
10
11
12
13
2
85
3
96
N.C. CONTACT. STOP
COMMON
N.O. CONTACT. OPEN
N.O. CONTACT. CLOSE
N.C. CONTACT.
PHOTOCELLS
RADIO CONTACT
LIMIT SWITCH. CLOSE. N.C.
LIMIT SWITCH. OPEN. N.C.
COMMON
ELECTRIC LOCK
POWER OUTPUT
19
18
16
17
COMMON
M
SINGLE-PHASE
ELECTRIC
MOTOR
230V FLASHING LAMP - 25W max
20
NEUTRAL
LIVE
2221
SUPPLY VOLTAGE
230V
SINGLE-PHASE
19
M
23
SUPPLY VOLTAGE
230-400V
THREE-PHASE
21 22 23
14
15
N.C. SAFETY
CONTACT
12 3 456 78
5 4 3 2 1
+
-
BRAKE
CONTROL
STEP SWITCH
BRAKE
CONNECTOR
Optional
Code 5578
34
1 PULSE: PEDESTRIAN OPENING
2 PULSES: FULL OPENING
PEDESTRIAN OPERATOR
THREE-PHASE
ELECTRIC
MOTOR
MICRO-PROCESSOR
ELPRO 10 F
-
+
DWELL
TIME
-
+
MOTOR RUN TIME
OPEN/CLOSE
400V
VOLTAGE
CHANGE-OVER SWITCH
230V
630mA
FUSE
FLASHING LAMP
1A FUSE
24V OUTPUT
TERMINALS 12-13
ON
OFF
12 345678
B
DIP-SWITCH
ON
80VA TRANSFORMER
400V - 24Vac
MOD. E010F
COMELIT
POT. 80VA 50/60Hz
PRI: 400-230V
SEC: 24V - 1A
Made in Italy
276/25/06/C
Drwg. No. 3339
GB
Elpro 10 F
FUNCTIONS OF THE ELECTRONIC PROGRAMMER FOR SLIDING GATES
All the electrical connections are to be made as per the following instructions and diagrams. Supply the terminals
21-22-23 with 230/400 V / 50 Hz, three-phase voltage. The "red led" No.1 switches on and stays on as long as the
board is properly supplied. Set the timer "MOTOR RUN. OPEN & CLOSE" so that the running time of the motor is longer
than the actual travel of the gate. Set the timer "DWELL" - i.e. the interval between open and re-close- so that you
can meet the required interval of time.
LOGIC OF THE ELECTRONIC PROGRAMMER: when a pulse is given, the flashing light switches on. After three seconds
the motor starts. During the interval before re-closing, the light stays on. When the gate has fully re-closed, the light
keeps on flashing for three more seconds and the switches off automatically. The 3 second interval (pre-flashing)
which precedes the actual start of the motor can be eliminated by means of the DIP-SWITCH B No. 4.
LED No. 1: It switches on when voltage is supplied.
LED No. 2: Photocells. Normally on. It switches off when the photocells are obstructed.
LED No. 3:  Open. It switches on when the respective switch is activated.
LED No. 4: Close. It switches on when the respective switch is activated.
LED No. 5: Stop. Normally on. It switches off when the respective switch is activated.
LED No. 6: Radio. It switches on whenever a pulse is given, either through remote control, keyswitch or push buttons.
LED No. 7: Limit switch. Close. It switches off when the gate is fully closed.
LED No. 8: Limit switch. Open. It switches off when the gate is fully open.
ELECTRONIC BRAKE TO FIT
ELPRO 10 F PROGRAMMER
- BRAKE FORCE ADJUSTMENT.
Force can be adjusted by means of a step
switch from one to five steps. (Optional)
B
DIP-SWITCH
1 2345678
ON
ON
OFF
GENERAL DIAGRAM. DIP-switches No. 1  2  3  4  5  6
No. 1 ON = PHOTOCELLS. STOP DURING "OPEN" CYCLE
No. 1 OFF = PHOTOCELLS. NO STOP DURING "OPEN" CYCLE. REVERSE ON CLOSING.
No. 2 ON = REMOTE CONTROL. NO REVERSE TRAVEL ON OPENING
No. 2 OFF = REMOTE CONTROL. REVERSE TRAVEL
No. 3 ON = AUTOMATIC RE-CLOSING
No. 3 OFF = NO AUTOMATIC RE-CLOSING
No. 4 ON = PRE-FLASHING
No. 4 OFF = NO PRE-FLASHING
No. 5 ON = REMOTE CONTROL. STEP BY STEP. STOP IN BETWEEN
No. 5 OFF = REMOTE CONTROL. GATE CAN BE REVERSED WHILE TRAVELLING
No. 6 ON = "DEADMAN CONTROL" (HOLD-ON SWITCHED). SET No.3 TO OFF
No. 6 OFF = OUT OF SERVICE. NORMAL OPERATING MODE
"
HOLD ON SWITCHED CONTROL": any open or close operations require that the respective
switch button or key is hold on pressed or turned until
the end of the operation.
SETTING FOR PARTIAL PEDESTRIAN OPENING. Dip-switches No. 7  8
A first "OPEN" pulse to terminal No.4 opens the gate to the distance set through
the switchs 7 - 8 as explained below; a second pulse opens the gate full travel.
78
ON
full
opening
78
ON
1 meter opening
78
ON
1.5 meter opening
78
ON
2 meter opening
B
DIP-SWITCH
1 2345678
ON
ON
OFF
_
+
54 21
LESS POWER
MORE POWER
BRAKE CONTROL
STEP SWITCH
5 4 3 2 1
+
-
BRAKE CONNECTOR
Code 5578
Via Mantova 177/A - 37053 Cerea (VR) Italy
Tel. 0442 330422 - Fax 0442 331054
e-mail: [email protected] - www.fadini.net
meccanica
FADINI
F
AUTOMATIC GATE MANUFACTURERS
Made in Italy
the gate opener
  • Page 1 1
  • Page 2 2

Fadini Elpro 10F Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document