Aiphone GW-LE8 is an audio module, used with other components to make up a selective calling audio door station. Panels from two to eight stations can be created. The entrance panel can selectively call and communicate with open voice inside master stations. Use any of the listed master stations: C-ML/A, LEM-1DL/C, LEF, LAF-C, or LDF Masters.

Aiphone GW-LE8 is an audio module, used with other components to make up a selective calling audio door station. Panels from two to eight stations can be created. The entrance panel can selectively call and communicate with open voice inside master stations. Use any of the listed master stations: C-ML/A, LEM-1DL/C, LEF, LAF-C, or LDF Masters.

- INSTRUCTIONS -
The GW-LE8 is an audio module, used with other components to make up a selective calling audio
door station. Panels from two to eight stations can be created. The entrance panel can selectively call
and communicate with open voice inside master stations. Use any of the above listed master stations.
GW-LE8
Selective Call Audio Module for Open Voice Systems
Use with:
C-ML/A, LEM-1DL/C, LEF, LAF-C, or LDF Masters
Special
Order
Products
Pg. 1
2 Call Panel
1
1
1
1
GW-LE8
GW-DP
GW-2P
GW-2
3 Call Panel
1
1
1
1
GW-LE8
GW-DP
GW-3P
GW-2
4 Call Panel
1
1
1
1
GW-LE8
GW-DP
GW-4P
GW-2
7 Call Panel
1
1
1
1
1
GW-LE8
GW-DP
GW-3P
GW-4P
GW-3
6 Call Panel
1
1
1
1
1
GW-LE8
GW-DP
GW-2P
GW-4P
GW-3
5 Call Panel
1
1
1
1
1
GW-LE8
GW-DP
GW-1P
GW-4P
GW-3
8 Call Panel
1
1
2
1
GW-LE8
GW-DP
GW-4P
GW-3
8 Call Entrance Station
GW-LE8
w/ GW-DP
GW-4P
(x2)
GW-3
SEMI-FLUSH AND SURFACE MOUNTING BOXES:
COMPONENT MODELS AND DESCRIPTIONS
GW-LE8 Terminal Definitions:
D+ Common communication
D- Negative, common call signal
Yel Common Call signal
Blu (8 wires) Selective Call-in and
communication wires (1 per button)
*MODULAR ENTRANCE STATIONS
List of components for each entrance panel:
Model
GW-LE8
GW-DP
GW-1P
GW-2P
GW-3P
GW-4P
GW-2
GW-3
Description
Audio Module
Audio Module Front Panel
1 Button Panel
2 Button Panel
3 Button Panel
4 Button Panel
2 Panel Back Box
3 Panel Back Box
Model
GW-002H
GW-002HB
GW-003H
GW-003HB
Description
Semi-flush Mt. Hood for GW-2
Surface Mt. Hood for GW-2
Semi-flush Mt. Hood for GW-3
Surface Mt. Hood for GW-3
Component
Module*
AC Power
~
~
Door Strike
WIRING DIAGRAM:
Install jumper
between D+/D-
GW-LE8
GW-LE8 WITH GW-4P, USING C-ML/A MASTER STATIONS
NOTES:
1. * Install bare wire end to "1" terminal
(DAK-2S contains two component modules).
2. Only components of the entrance panel that include wire
connections are shown here.
3. See C-ML/A instructions for complete installation information.
C-ML/A
-
+
SKK-620
E
-
+
1
L
L
C-ML/A
-
+
SKK-620
C-ML/A
-
+
SKK-620
GW-4P
1
2
3
4
Component
Module*
Component
Module*
Component
Module*
E
-
+
1
L
L
E
-
+
1
L
L
C-ML/A
-
+
SKK-620
E
-
+
1
L
L
D+
D-
Yel
Blu
Blu
Blu
Blu
Blu
Blu
Blu
Blu
RY-PA
~
~
AC Power
Door Strike
BlkYel
LEF-3L #1
GW-LE8
-
+
PS-12C
Remove E/-
jumper on all
masters.
GW-LE8 WITH GW-4P & GW-2P, USING LEF-3L MASTER STATIONS
GW-4P
GW-2P
E
-
+
R
1
Brn
Wht
E
-
+
R
1
Brn
Wht
E
-
+
R
1
Brn
Wht
E
-
+
R
1
Brn
Wht
E
-
+
R
1
Brn
Wht
E
-
+
R
1
Brn
Wht
D+
D-
Yel
Blu
Blu
Blu
Blu
Blu
Blu
Blu
Blu
1
2
3
4
1
2
NOTES:
1. In this example, the door station rings in on station #1 of each master station.
It can be wired to any unused station number.
2. Only components of the entrance panel that include wire connections are shown here.
3. For complete wiring information, please see the LEF-3L instructions.
If additional master stations are to be installed in each office/suite, wire them per the standard instructions.
WIRING DIAGRAM:
LEF-3L #2 LEF-3L #3 LEF-3L #4 LEF-3L #5 LEF-3L #6
Pg. 2
WIRING DIAGRAM:
GW-LE8 WITH GW-4P, USING LEM-1DL/C MASTER STATIONS
AC Power
~
~
Door Strike
GW-LE8
GW-4P
1
2
3
4
D+
D-
Yel
Blu
Blu
Blu
Blu
Blu
Blu
Blu
Blu
E
-
+
R
1
EL
EL
LEM-1DL/C
~
~
PT-1210N
E
-
+
R
1
EL
EL
LEM-1DL/C
~
~
PT-1210N
E
-
+
R
1
EL
EL
LEM-1DL/C
~
~
PT-1210N
E
-
+
R
1
EL
EL
LEM-1DL/C
~
~
PT-1210N
RY-PA
~
~
AC Power
Door Strike
BlkYel
LEF-5 #1
GW-LE8
-
+
PS-12C
Remove D+/D-
jumper on all
masters.
GW-LE8 WITH GW-4P & GW-2P, USING LEF-5 MASTER STATIONS
LEF-5 #5 LEF-5 #6LEF-5 #4LEF-5 #3LEF-5 #2
GW-4P
GW-2P
E
-
+
R
1
K1
L
E
-
+
R
1
K1
L
E
-
+
R
1
K1
L
E
-
+
R
1
K1
L
E
-
+
R
1
K1
L
E
-
+
R
1
K1
L
D+
D-
Yel
Blu
Blu
Blu
Blu
Blu
Blu
Blu
Blu
1
2
3
4
1
2
NOTES:
1. In this example, the door station rings in on station #1 of each master station.
It can be wired to any unused station number.
2. Only components of the entrance panel that include wire connections are shown here.
3. For complete wiring information, please see the standard LEF instructions.
If additional master stations are to be installed in each office/suite, wire them per the standard instructions.
WIRING DIAGRAM:
Pg. 3
NOTES:
1. Only components of the entrance panel that include wire
connections are shown here.
2. For complete wiring information, please see the LEM-1DL/C
instructions.
Install jumper
between D+/D-
Pg. 4
GW-4P
1
2
3
4
RY-PA
~
~
AC Power
Door Strike
BlkYel
GW-LE8
+
-
PS-12C
GW-LE8 WITH GW-4P, USING LEF-3L MASTER STATIONS WITH COMMON AND INDIVIDUAL DOOR STATIONS
NOTES:
1. Remove D+/D- jumper on all masters.
2. Only components of the entrance panel that include wire connections are shown here.
3. For complete wiring information, please see the standard LEF instructions.
If additional master stations are to be installed in each office/suite, wire them per the standard instructions.
WIRING DIAGRAM:
LEF-3L #1
1
2
E
+
-
R
K2
L
K1
1
E
-
LE-D
To Indv. Door
Strike &
Power
RY-PA
BlkYel
LEF-3L #2
1
E
-
LE-D
To Indv. Door
Strike &
Power
RY-PA
BlkYel
LEF-3L #3
1
E
-
LE-D
To Indv. Door
Strike &
Power
RY-PA
BlkYel
LEF-3L #4
1
E
-
LE-D
To Indv. Door
Strike &
Power
RY-PA
BlkYel
Yel
Blu
Blu
Blu
Blu
Blu
Blu
Blu
Blu
D+
D-
1
2
E
+
-
R
K2
L
K1
1
2
E
+
-
R
K2
L
K1
1
2
E
+
-
R
K2
L
K1
MOUNTING:
1. Cut appropriate sized mounting hole into wall.
GW-2
8-1/8"
4-1/2"
Flush mount installation with weather hood:
GW-DP +
GW-LE8
(GW-LE8 mounts to GW-DP
with supplied screws)
GW-3
(Frame)
GW-4P
(Call switch panel)
GW-3
(Box)
GW-003H
(Weather hood)
Standard flush mount installation:
GW-3
(Box)
GW-DP +
GW-LE8
(GW-LE8 mounts to GW-DP
with supplied screws)
GW-3
(Frame)
GW-4P
(Call switch panel)
Surface mount installation with weather hood:
GW-DP +
GW-LE8
(GW-LE8 mounts to GW-DP
with supplied screws)
GW-3
(Frame)
GW-4P
(Call switch panel)
GW-003HB
(Weather hood)
GW-3
4-1/2"
11-3/4"
2. Assemble and mount entrance panel
1. Open a hole in the back box to pass cable through.
2. Mount the GW-LE8 to the GW-DP using the supplied screws.
3. Mount the components to the GW-2 or GW-3 frame.
4. Mount the frame to the back box.
5. Replace the two mounting screw covers.
Filling in resident names:
1. Remove protective cover using opener.
(Opener included with GW-2 and GW-3 frames)
Protective Cover
Opener
Pg. 5
OPERATION:
1. The entry station has multiple call buttons with an associated directory card. Press the button of the
person you wish to call.
2. The master station(s) will ring an electronic call tone as long as the call button on the entrance station
is being held. (A chime will be heard when using the C-ML/A room stations.)
3. With CM-L/A and LEM-1DL/C Master Stations: Press TALK button to answer the call.
With LEF Master Stations: Select the station button with the lit LED to answer. If the LED has gone out
(stays on for approx. 20 seconds), press the selector button assigned to the entry station.
4. At the inside station, press the TALK button to talk, and release to listen. The person at the entrance
station speaks hands free.
5. When finished with the call, press the OFF button on the master station.
6. NOTE: If the "Occupied" lamp is on, the system is in use. Wait until the LED goes out, or determine if
a master station has been left on unintentionally.
SPECIFICATIONS:
Power Source: Provided from master station.
C-ML/A: 1 SKK-620 or 4 "C" batteries per master.
LEM-1DL/C: 1 PT-1210N per master.
LEF: 1 PS-12C per system.
Impedance: 20 ohms
Communication: Hands free at entry station. Push-to-talk at master station.
Calling: C-ML/A: 4-Stroke chime
LEM-1DL/C: Momentary call tone
LEF: Momentary call tone and LED, remaining lit for approx. 20 seconds
Wiring: C-ML/A: 2 conductors homerun per station to entrance panel.
LEM-1DL/C: 2 conductors homerun per station to entrance panel.
LEF: 4 common (E, R, +, -) plus 1 individual per sub, looped; or 5 conductors homerun
to each master. Shielded cable is recommended.
Use Aiphone #822202 (2 conductor) or 822212 (12 conductor) for max. 8 station wiring.
Door Release Wiring: 2 conductors looped through stations to strike and strike power supply.
Wiring Distance: C-ML/A: 245' with 22AWG; 590' with 18AWG.
LEF/LEM: 650' with 22AWG; 1,600' with 18AWG.
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
TOLL FREE FAX LINE:
(800) 832-3765
Pg. 6
GW-LE8 Instr.
1001bkjd
NOTE:
Only information concerning the GW-LE8 is shown here.
For complete wiring information, please see the appropriate system instructions.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Aiphone GW-LE8 User manual

Type
User manual

Aiphone GW-LE8 is an audio module, used with other components to make up a selective calling audio door station. Panels from two to eight stations can be created. The entrance panel can selectively call and communicate with open voice inside master stations. Use any of the listed master stations: C-ML/A, LEM-1DL/C, LEF, LAF-C, or LDF Masters.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI