3One data 7212 User manual

Category
Network switches
Type
User manual
Your Serial and Data Communications Expert
Shen zhen 3onedata Technology Co.,Ltd
MODEL7212
MODEL7212
MODEL7212
MODEL7212
10/100M
10/100M
10/100M
10/100M Ethernet
Ethernet
Ethernet
Ethernet to
to
to
to FE1
FE1
FE1
FE1 Bridge
Bridge
Bridge
Bridge User
User
User
User Manual
Manual
Manual
Manual
I
I
I
I ntroduction
ntroduction
ntroduction
ntroduction :
:
:
:
MODEL7212 bridge provides easy conversion from ITU-T G.703
E1 channel to Ethernet interface. Can used widely in connecting
between WAN and LAN, monitoring, etc. The Ethernet interface is
10/100Mbps auto negotiation and can be full/half duplex. The E1 is
transparent and in full rate, which can support the E1 unframed
mode, including fractional E1 per request.
A
pair of MODEL7212
offer a cost effective solution for using existing E1 leased lines for
transparent Ethernet service. Local management of the
MODEL7212 Converter is provided via DIP switches. Front panel
LEDs monitor the G.703 link, Ethernet LAN and serial ports for
status and Loss of Sync. MODEL7212 compact G.703 Access
Converter provides E1/2.048 Mbps Network Termination as well as
serial or Ethernet LAN interface conversion in a standalone or rack
mount package. MODEL7212 terminates the G.703 Telco interface
and converts the data for transmission to a user-oriented
10/100BaseT(X) interface.
Packing
Packing
Packing
Packing L
L
L
L ist
ist
ist
ist :
:
:
:
MODEL7212 is shipped with following items.
1. MODEL7212
×
1
2. 220V power line
×
1
3. User manual
×
1
F
F
F
F eatures:
eatures:
eatures:
eatures:
1. Using E1 line transparent transfer Ethernet data
2. Support N × 64Kbps(N=1~32) rate
3. Support local clock and line clock
4. Support pretend random coding loop test
5. E1(G.703)interface support 120ohm(RJ-45)and 75ohm(BNC
double coaxial)
Your Serial and Data Communications Expert
Shen zhen 3onedata Technology Co.,Ltd
6. Ethernet MAC address percolate function
7. Support VLAN over length data bag
8. Ethernet port support 10M/100M full-duplex/half-duplex
Description
Description
Description
Description on
on
on
on Installation
Installation
Installation
Installation and
and
and
and Panels:
Panels:
Panels:
Panels:
1.
1.
1.
1. The
The
The
The product
product
product
product front
front
front
front panel
panel
panel
panel sketch
sketch
sketch
sketch map
map
map
map :
:
:
:
indicator
indicator
indicator
indicator define:
define:
define:
define:
P
P
P
P WR
WR
WR
WR Power indicator. Brightness if electrify.
LINK
LINK
LINK
LINK Ethernet connection constitute.
F/H
F/H
F/H
F/H Ethernet Fall/half duplex indicator, bright as full duplex.
100M
100M
100M
100M Ethernet port 100M indication.
10M
10M
10M
10M Ethernet port 10M indication.
LOS
LOS
LOS
LOS E1line cut alarm indicator light
SLOS
SLOS
SLOS
SLOS E1 line frame misstep indicator.
2.
2.
2.
2. The
The
The
The product
product
product
product back
back
back
back panel
panel
panel
panel sketch
sketch
sketch
sketch map:
map:
map:
map:
POWER
POWER
POWER
POWER -48VDC/220VAC input choice
ON/OFF
ON/OFF
ON/OFF
ON/OFF power switch
Rx/75
Rx/75
Rx/75
Rx/75 o
o
o
o hm
hm
hm
hm E1-75 Ω input
Tx/75
Tx/75
Tx/75
Tx/75 o
o
o
o hm
hm
hm
hm E1-75 Ω output
10/100M
10/100M
10/100M
10/100M Ethernet interface(input and output)
Definition
Definition
Definition
Definition of
of
of
of balanced
balanced
balanced
balanced Twisted
Twisted
Twisted
Twisted Pair(120
Pair(120
Pair(120
Pair(120 ohm)
ohm)
ohm)
ohm) wire
wire
wire
wire
sequence
sequence
sequence
sequence for
for
for
for E1
E1
E1
E1 and
and
and
and Ethernet
Ethernet
Ethernet
Ethernet interface:
interface:
interface:
interface:
1.
1.
1.
1. Ethernet
Ethernet
Ethernet
Ethernet RJ-45
RJ-45
RJ-45
RJ-45 interface
interface
interface
interface define
define
define
define
Your Serial and Data Communications Expert
Shen zhen 3onedata Technology Co.,Ltd
NO.
NO.
NO.
NO. Function
Function
Function
Function define
define
define
define I/O
I/O
I/O
I/O
1 TX+ (send data +) output
2 TX- (send data -) output
3 RX+( receive data +) input
4 NC(null)
5 NC(null)
6 RX-(receive data -) input
78 NC(null)
2.
2.
2.
2. E1
E1
E1
E1 interface
interface
interface
interface 120
120
120
120 Ω/RJ-45
/RJ-45
/RJ-45
/RJ-45 define
define
define
define
NO.
NO.
NO.
NO. Function
Function
Function
Function define
define
define
define I/O
I/O
I/O
I/O
1 NC(null)
2 RX+(receive data +) input
3 RX-(receive data -) input
4 GND(ground)
5 GND(ground)
6 TX+(send data +) output
7 TX-(send data -) output
8 NC(null)
DIP
DIP
DIP
DIP switch
switch
switch
switch setup
setup
setup
setup (
(
(
(Function
Function
Function
Function setup
setup
setup
setup switch
switch
switch
switch SW1
SW1
SW1
SW1 )
)
)
) :
:
:
:
There have a range of DIP switch in the 7212 panel,
Time Slot is used to choose E1 time slot SW1 is used to
function setup.
1.
1.
1.
1. C
C
C
C lock
lock
lock
lock choice
choice
choice
choice
NO.1 NO.2
O N O FF inside clock (from Model 7212 panel)
O FF O FF comeback clock (from E1 interface)
2.
2.
2.
2. Ethernet
Ethernet
Ethernet
Ethernet mode
mode
mode
mode choice
choice
choice
choice
NO.3 NO.4 NO.5 Ethernet mode
O FF O FF OFF 10/100M
full/half duplex
auto-negotiation
O FF O N OFF 10/100M auto-negotiation
half duplex
Your Serial and Data Communications Expert
Shen zhen 3onedata Technology Co.,Ltd
O FF O FF ON 10M
full/half duplex
auto-negotiation
O FF O N ON 10M
half duplex
O N O FF OFF 100M
full duplex
O N O N OFF 100M
half duplex
O N O FF ON 10M
full duplex
O N O N ON 10M
half duplex
3.
3.
3.
3. Impedance
Impedance
Impedance
Impedance setup
setup
setup
setup
NO.6 NO.7 NO.8
O N O N ON 75ohm
O FF O FF OFF 120ohm
4.
4.
4.
4. E1
E1
E1
E1 time
time
time
time slot
slot
slot
slot choice
choice
choice
choice
Time Slot has 32 switch from left to right, delegate 0-31 time slot.if
one switch is ON, it means choice this time
slot . A ll 32 time slots are OFF, it means non-frame format . I f the
zero time slot is ON, adopt PCM30, OFF, adopt PCM3 1.
Specification
Specification
Specification
Specification s:
s:
s:
s:
E1
E1
E1
E1 interface
interface
interface
interface
S tandard : Comply with ITU-T G.703
Output tingle displace: accord ITU-TG.735 advice
Input tingle limit: accord ITU-TG.823 advice
Output tingle: accord ITU-T G.823 advice
Fra me format: framed
I nterface rate : N × 64Kbps(N=1~32) rate
CRC checkout: no
P ort coding : HDB3
P ort transmission : 2KM
P ort protection : 1500V electromagnetism isolate
P ort connector : 120 Ohm(RJ-45) and 75 ohm(BNC double coaxial)
E
E
E
E t
t
t
t hernet
hernet
hernet
hernet port
port
port
port
Inte r f a c e T y pe s: 10/ 1 00 B as e T , full/half duplex
Sta n da r d s Com p li anc e: IEE E 80 2 .3
B i t R a t e: 10/ 1 00 B as e T l i m i te d t o M a x 2 . 0 4 8 M bps
C onne c to r s: R J 4 5 ( 10 / 1 0 0 Ba s e- T E l e c t ri c a l )
Line code: Manchester Encoding
Your Serial and Data Communications Expert
Shen zhen 3onedata Technology Co.,Ltd
Inte
Inte
Inte
Inte rn
rn
rn
rn a
a
a
a l
l
l
l a
a
a
a n
n
n
n d
d
d
d recover
recover
recover
recover c
c
c
c l
l
l
l ock
ock
ock
ock
Environment
Environment
Environment
Environment ,
,
,
, Power
Power
Power
Power and
and
and
and Dimension
Dimension
Dimension
Dimension
Working temperature : -25 to 70 ° C
Storage temperature : -40 to 85 ° C
Humidity : Relative humidity 5% to 95%
Input power : 220V AC or -48VDC
Consumption: 2W
Power protection: From high voltage/short circuit
L × W × H: 227 .4 mm × 14 6.3 mm × 42 .7 mm
Shell : Plastic
Weight : 260g
Warranty:
Warranty:
Warranty:
Warranty: 5
5
5
5 years
years
years
years
Certifications:
Certifications:
Certifications:
Certifications:
Shenzhen
Shenzhen
Shenzhen
Shenzhen 3onedata
3onedata
3onedata
3onedata Technology
Technology
Technology
Technology Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Tel : +86-755-26702688 Fax : +86-755-26703485
www.3onedata.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

3One data 7212 User manual

Category
Network switches
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI