  • Hello! I am an AI chatbot trained to assist you with the Kingspan Insulation 100000050515 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
R-Value
Climate
Zone
Wood Frame Wall
R-Value
Basement
Wall
b
R-Value
Slab
c
R-Value
& Depth
Crawl Space
b
Wall R-Value
1 13 0 0 0
2 13 0 0 0
3 20 or 13 + 5
a
5 / 13 0 5 / 13
4
d
20 or 13 + 5
a
10 / 13 10 / 2 ft 10 / 13
5
e
20 or 13 + 5
a
15 / 19 10 / 2 ft 15 / 19
6 20 + 5
a
or 13 + 10
a
15 / 19 10 / 4 ft 15 / 19
7 20 + 5
a
or 13 + 10
a
15 / 19 10 / 4 ft 15 / 19
8 20 + 5
a
or 13 + 10
a
15 / 19 10 / 4 ft 15 / 19
Recommended Home Insulation R-Values
CLIMATE ZONE R-VALUE REFERENCE GUIDE FOR XPS
Determine Your R-Value and Thickness
2
Determine Your Location
1
a. Therestvalueiscavityinsulation,thesecondvalueiscontinuousinsulation.Therefore,asanexample,“13+5”meansR-13cavity
insulationplusR-5continuousinsulation
b. “10/13”meansR-10continuousinsulationontheinteriororexteriorofthehomeorR-13cavityinsulationontheinteriorofthe
basementwall.
“15/19”meansR-10continuousinsulationontheinteriororexteriorofthehomeorR-13cavityinsulationattheinteriorofthebasement
wall.Alternatively,compliancewith“15/19”shallbeR-13cavityinsulationontheinteriorofthebasementwallplusR-5continuous
insulationontheinteriororexteriorofthehome.
c. R-5insulationshallbeprovidedunderthefullslabareaofaheatedslabinadditiontotherequiredslabedgeinsulationR-valuefor
slabs,asindicatedinthetable.Theslabedgeinsulationforheatedslabsshallnotberequiredtoextendbelowtheslab.
d. exceptMarine
e. andMarine4
®
Kingspan, the G Device and the Lion Device are Registered Trademarks of the Kingspan Group plc in the US, Canada and other
countries. All rights reserved.
®
GreenGuard is a Registered Trademarks of the Kingspan Group plc in the US. All rights reserved.
2018 IECC - International Energy Conservation Code
GreenGuard XPS has an R-Value of R-5 per inch
AllofAlaskaisinZone7exceptforthefollowingboroughsinZone8:Bethel,NorthwestArtic,Dellingham,
SoutheastFairbanks,FairbanksN.Star,WadeHampton,Nome,Yukon-Koyukuk,NorthSlope
Zone1IncludesHawaii,Guam,PuertoRico,andtheVirginIslands
U.S. Department of Energy R-value per zone recommendations are based
on estimated future energy savings to the current cost of insulation.
/