Fair-Play FAIR-PLAY GL-7248-WRD Wired LED Goal Light is a lighting system designed to enhance visibility and safety in sports arenas. It features multiple LED strips that can be easily installed on basketball goals, providing bright and even illumination. The light strips can be connected to a scoreboard or shot clock for synchronization with game events, such as the start and end of periods or when a goal is scored. Additionally, the goal light can be integrated with Fair-Play MP-70 or MP-80 controllers for seamless operation within existing sports facilities.

Fair-Play FAIR-PLAY GL-7248-WRD Wired LED Goal Light is a lighting system designed to enhance visibility and safety in sports arenas. It features multiple LED strips that can be easily installed on basketball goals, providing bright and even illumination. The light strips can be connected to a scoreboard or shot clock for synchronization with game events, such as the start and end of periods or when a goal is scored. Additionally, the goal light can be integrated with Fair-Play MP-70 or MP-80 controllers for seamless operation within existing sports facilities.

LED LIGHT STRIP - INSTALLATION INSTRUCTIONS
REAR-SIDE
OF GOAL
A
B
STEP 1
THOROGHLY CLEAN GLASS USING RUBBING
ALCOHOL TO REMOVE ANY GRIME OR RESIDUE
WHICH MAY IMPAIR THE BOND OF THE ADHESIVE.
STEP 3
CONTINUE AROUND PERIMETER
WITH NO GAP BETWEEN STRIPS.
REPEAT ON THE OTHER SIDE.
STEP 4
INSTALL SHORT STRIP CONNECTOR HARNESSES
BETWEEN 18” STRIPS AND 21” STRIPS AT CORNERS,
SIDES, AND TOP (*).
NOTE:
18” STRIP, 21” STRIP, AND STRIP CONNECTOR
HARNESSES ARE BI-DIRECTIONAL.
,
STEP 5
CONNECT THE LONG STRIP CONNECTOR
HARNESS TO THE LAST 21” STRIP.
STEP 6
REPEAT STEPS TO INSTALL GOAL LIGHT
TO 2ND BACKBOARD.
STEP 2
CENTER THE 21STRIP HORIZONTALLY TO THE GOAL,
AND 5/8" INCH BELOW THE GOAL BORDER TAPE.
18IN
21.5IN
23IN (approx.)
23IN (approx.)
21” STRIP 21” STRIP
21” STRIP 21” STRIP
21” STRIP
21.5IN
18” STRIP
18” STRIP
18” STRIP
18” STRIP
5/8IN (approx.)
21STRIPS
18STRIPS
DETAIL B
SHORT STRIPS OVERLAP
LONG STRIPS AT THE CORNERS
21STRIPS
18STRIPS
DETAIL A
SHORT STRIPS OVERLAP
LONG STRIPS AT THE CORNERS
PN 98-7248-WRD-01•REV 2020.11.11
GL-7248-WRD
WIRED LED GOAL LIGHT
TOOLS REQUIRED
* Verify that all parts are present.
• Rubbing Alcohol
• Cleaning Rags
• Screwdrivers
6110 Aviator Drive, Hazelwood, MO 63042
Toll Free: (800) 462-2716
ITEM PART # QTY
1 TRANSCEIVER (NO RADIO) 2
2 18” STRIP 8
8 LONG STRIP CONNECTOR HARNESS 2
9 4’ EXT POWER CABLE (CUT) 2
4 5-PIN CABLE, 8” 2
10 1/2” STRAIN RELIEF 2
6 18” EXTENSION CABLE 2
5 24VDC POWER SUPPLY 2
7 SHORT STRIP CONNECTOR HARNESS 16
3 21” STRIP 10
15VDC
POWER
SUPPLY
(EXISTING)
18” EXTENSION
CABLE
LONG STRIP
CONNECTOR
HARNESS
STEP 5
PLACE 24VDC POWER SUPPLY
ON BOTTOM OF SHOT CLOCK.
STEP 7
REMOVE EXISTING 7/8” HOLE PLUG OR
DRILL 7/8” DIAMETER HOLE THROUGH
CABINET. INSTALL STRAIN RELIEF.
CONNECT TO
GOAL LIGHT
DISCONNECT POWER
BEFORE INSTALLING
CAUTION
STEP 1
PN 98-7248-WRD-01•REV 2020.11.11
TRANSCEIVER
GOAL
LIGHT
24V
POWER 5-PIN
DATA IN
DRIVER BOARD
K28
DATA IN
K15
RADIO INPUT
SMOOTH
RIDGED
N L
120VAC
STEP 6
DO NOT DISCONNECT EXISTING WIRES.
LOOSEN NEUTRAL (N) AND HOT (L) TERMINALS AND
CONNECT THE RIDGED AND SMOOTH WIRES TO THEIR
CORRESPONDING TERMINALS:
L (HOT) - SMOOTH SIDE OF CORD
N (WHT) - RIDGE OR LINE SIDE OF CORD
TIGHTEN TERMINAL SCREWS.
STEP 2
INSTALL TRANSCEIVER WITHIN
REACH OF 18” EXTENSION
CABLE AND THE DATA INPUT
CABLE AND K15 DRIVER
BOARD RADIO INPUT.
STEP 3
UPLUG DATA CABLE FROM
DRIVER BOARD K28, THEN
CONNECT IT TO TRANSCEIVER
DATA IN.
AC PLUG
MALE
AC PLUG
FEMALE
STEP 4
CONNECT 5-PIN CABLE
TO K15.
GOAL LIGHT WIRED TO SHOT CLOCK
STEP 9
CONNECT LONG STRIP CONNECTOR
TO GOAL LIGHT AND 18” EXTENSION
CABLE.
STEP 8
ROUTE 18” EXTENSION CABLE
THROUGH STRAIN RELIEF.
LEAVE FEMALE END OUTSIDE
OF CABINET. CONNECT MALE
END TO GOAL LIGHT
TERMINAL OF TRANSCEIVER.
24VDC
POWER
SUPPLY
STRAIN
RELIEF
CABINET
GOAL LIGHT WIRED TO SCOREBOARD
CONNECT TO
GOAL LIGHT
24VDC
POWER
SUPPLY
AC PLUG
MALE
AC PLUG
FEMALE
DISCONNECT POWER
BEFORE INSTALLING
CAUTION
STEP 1
15VDC
POWER
SUPPLY
(EXISTING)
SMOOTH
RIDGED
N L
120VAC
TRANSCEIVER
GOAL
LIGHT
24V
POWER 5-PIN
DATA IN
DRIVER BOARD
K28
DATA IN
K15
RADIO INPUT
STRAIN
RELIEF
CABINET
STEP 5
PLACE 24VDC POWER SUPPLY
ON SHELF OF SCOREBOARD.
STEP 2
INSTALL TRANSCEIVER
WITHIN REACH OF THE
DATA INPUT CABLE AND
K15 DRIVER BOARD
RADIO INPUT.
STEP 3
UPLUG DATA CABLE
FROM DRIVER BOARD
K28, THEN CONNECT
IT TO TRANSCEIVER
DATA IN.
STEP 4
CONNECT 5-PIN INTERFACE
HARNESS TO K15.
STEP 7
LOOSEN NEUTRAL (N) AND HOT (L)
TERMINALS AND CONNECT WIRES TO
TERMINALS AS FOLLOWS:
L (HOT) - SMOOTH SIDE OF CORD
N (WHT) - RIDGE OR LINE SIDE OF CORD
DO NOT DISCONNECT EXISTING WIRES.
TIGHTEN TERMINAL SCREWS.
REMOVE
SLIDE UP, PULL
INSTALL
PUSH, SLIDE DOWN
STEP 8
PLACE THE POWER
SUPPLY ASSEMBLY
BACK TO THE BACK
PANEL AND REINSTALL
LOCKING SCREW.
STEP 6
REMOVE AND SAVE
LOCKING SCREW.
SLIDE THE ENTIRE
POWER SUPPLY
ASSEMBLY UP AND
REMOVE FROM THE
BACK PANEL.
STEP 9
REMOVE EXISTING 7/8” HOLE PLUG OR
DRILL 7/8” DIAMETER HOLE THROUGH
CABINET. INSTALL STRAIN RELIEF.
STEP 10
CONNECT CUSTOM LENGTH
LONG STRIP CONNECTOR
HARNESS TO GOAL LIGHT AND
TRANSCEIVER.
PN 98-7248-WRD-01•REV 2020.11.11
PN 98-7248-WRD-01•REV 2020.11.11
POWER UP & OPERATION
1. POWER UP THE GOAL LIGHTS IN THE FOLLOWING
ORDER:
• POWER UP THE SCOREBOARD,
• POWER UP THE SHOT CLOCK,
• POWER UP THE MP-70 OR MP-80 CONTROLLER.
THE GOAL LIGHTS WILL TURN ON FOR A FEW SECONDS
AND TURN OFF. THEN IT LOOKS FOR A DATA SIGNAL.
IF DATA SIGNAL IS FOUND, THEN THE GOAL
LIGHTS WILL REMAIN OFF.
IF DATA SIGNAL IS NOT FOUND, THEN THE GOAL
LIGHTS WILL FLASH CONTINUOUSLY AS FOLLOWS:
THE TOP BAR, A SIDE BAR, OFF FOR SEVERAL
SECONDS, THEN REPEAT.
2. START A NEW GAME (ON THE CONTROLLER), THEN
• START THE GAME CLOCK SWITCH (MP-80) OR
TIME IN (MP-70).
IF THE DATA SIGNAL IS LOST, THEN THE GOAL LIGHTS REMAIN
OFF UNTIL DATA SIGNAL IS FOUND. CHECK POWER AND DATA
FROM SCOREBOARD AND SHOT TIMER.
3. WHEN GAME CLOCK REACHES ZERO, THE GOAL LIGHT
TURNS ON.
TO TURN OFF THE GOAL LIGHTS:
PRESS STOP ON GAME CLOCK SWITCH (MP-80), OR
• PRESS TIME OUT (MP-70).
• GO TO STEP 2 ABOVE.
IF THE DATA SIGNAL IS LOST, THEN THE GOAL LIGHTS REMAIN
ON EXCEPT FOR BOTTOM HORIZONTAL BAR UNTIL DATA
SIGNAL IS FOUND. CHECK POWER AND DATA FROM
SCOREBOARD AND SHOT TIMER.
REAR-SIDE
OF GOAL
LONG STRIP CONNECTOR
HARNESS FROM SHOT TIMER
OR SCOREBOARD.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Fair-Play FAIR-PLAY GL-7248-WRD Wired LED Goal Light User manual

Type
User manual
This manual is also suitable for

Fair-Play FAIR-PLAY GL-7248-WRD Wired LED Goal Light is a lighting system designed to enhance visibility and safety in sports arenas. It features multiple LED strips that can be easily installed on basketball goals, providing bright and even illumination. The light strips can be connected to a scoreboard or shot clock for synchronization with game events, such as the start and end of periods or when a goal is scored. Additionally, the goal light can be integrated with Fair-Play MP-70 or MP-80 controllers for seamless operation within existing sports facilities.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI