Installaon
Installaon Manual
3. Neutralizer kit: 9007607005 (TH-NT01)
The neutralizer assembly neutralizes the condensate (acidic water) that forms in the
secondary heat exchanger of the water heater.
It connects to the condensate drain port of the water heater by using connectors
includedwiththeneutralizerkit.(Refertop.29.)
The temperature remote controller
has two functions. It allows the
output temperature from the water
heater to be adjusted within the range
of100°Fto185°F,anditalsoworks
as a diagnostic tool that will give a
concise error code whenever there is
a problem with the unit.
1. Temperature remote controller:
9008172005 (TM-RE40)
5. 3" PVC concentric termination: 9007611005 (TH-CVPVC33)
Used when terminating direct-vent (sealed combustion)
systems,withIndoormodelsthatrequirea3in.(76mm)intake
anda3in.(76mm)exhaust.
The pipe cover protects the plumbing pipes to
the water heater from unexpected adjustments.
This pipe cover is fixed to the bottom of the water
heater, which hides the plumbing and improves
the visual aspects of the whole installation for
the water heater.
2. Pipe cover: 9008331005 (TH-PC03)
4. Sidewall vent terminator (Hood) and Wall thimble:
They are used when venting out through the wall. These terminations are special stainless steel vents
for gas appliances and are UL listed as Category II, III and IV. For different wall thicknesses, there
are two ranges of lengths available. (Refer to the NovaVent brochure for details.) Install these vent
terminations in accordance with their installation instructions and any applicable local codes.
Covering wall thicknesses Part#
Terminator Hood 9007999005
Wall Thimble 4 - 7 in. 9008345005
WallThimble5-10in. 9008346005
Termination + Thimble 4 - 7 in. 9008004005
Termination+Thimble5-10in. 9008005005
Wall Thimble
Terminator Hood
6. Non-return valve: 9008847005
It is a must-have item for common venting system. It prevents
the escape of combustion gas through non-operating appliances.
(Refertop.20and21.)
The temperature options are 100 °F, 105 °F, 110
°F,115°F,120°F,125°F,130°F,135°F,140°F,145
°F,150°F,155°F,160°F165°F,175°Fand185°F.
See the Troubleshooting Section for information on
possible error codes.
This concentric termination provides the convenience of only having to make one penetration through a
sidewall instead of two separate penetrations for the intake and exhaust piping. The termination includes
a bird screen, restricting small animals, pests, and foreign objects from entering into the vent system.