GW Instek AFG-303x User manual

Category
Power generators
Type
User manual
Arbitrary Function Generator
AFG-3021, 3022, 3031 & AFG-3032
USER MANUAL
ISO-9001 CERTIFIED MANUFACTURER
April 2021 edition
This manual contains proprietary information, which is protected by
copyright. All rights are reserved. No part of this manual may be
photocopied, reproduced or translated to another language without
prior written consent of Good Will Corporation.
The information in this manual was correct at the time of printing.
However, Good Will continues to improve its products and therefore
reserves the right to change the specifications, equipment, and
maintenance procedures at any time without notice.
Good Will Instrument Co., Ltd.
No. 7-1, Jhongsing Rd., Tucheng Dist., New Taipei City 236, Taiwan.
TABLE OF CONTENTS
3
Table of Contents
SAFETY INSTRUCTIONS .................................. 7
Safety Symbols ........................................................... 7
Safety Guidelines ........................................................ 8
GETTING STARTED ....................................... 13
Main Features ........................................................... 13
Panel Overview ......................................................... 16
Setting up the Function Generator ............................ 23
QUICK REFERENCE ....................................... 25
How to use the Digital Inputs ................................... 27
How to use the Help Menu ....................................... 28
Selecting a Waveform ............................................... 31
Modulation ............................................................... 35
Sweep ....................................................................... 42
Burst ........................................................................ 43
ARB .......................................................................... 44
Utility Menu ............................................................. 49
IQ Waveform ............................................................ 52
Menu Tree ................................................................ 53
Default Settings ........................................................ 75
OPERATION .................................................. 77
Select a Channel ....................................................... 78
Select a Waveform .................................................... 79
MODULATION............................................... 95
Amplitude Modulation (AM & AM(DSB-SC)) ............ 98
Frequency Modulation (FM) ................................... 109
Frequency Shift Keying (FSK) Modulation ............... 117
Phase Modulation (PM) .......................................... 124
AFG-3021/3022/3031/3032 User Manual
4
Phase Shift Keying (PSK) Modulation ..................... 130
SUM Modulation .................................................... 136
Pulse Width Modulation ......................................... 143
Sweep ..................................................................... 150
Burst Mode ............................................................. 161
SECONDARY SYSTEM FUNCTION SETTINGS
.................................................................... 172
Save, Recall or Delete ............................................. 173
Selecting the Remote Interface ............................... 177
System and Settings ............................................... 182
DUAL CHANNEL & MULTI-UNIT OPERATION
.................................................................... 190
Dual Channel Settings ............................................ 191
Multi-Unit Syncing .................................................. 200
ARBITRARY WAVEFORMS ............................ 204
Inserting Built-In Waveforms .................................. 205
Display an Arbitrary Waveform ................................ 212
Editing an Arbitrary Waveform ................................ 219
Output an Arbitrary Waveform ................................ 228
Saving/Loading an Arbitrary Waveform ................... 235
IQ WAVEFORMS .......................................... 243
IQ Waveforms Output ............................................. 244
REMOTE INTERFACE ................................... 257
Establishing a Remote Connection .......................... 258
Web Browser Control Interface ............................... 264
Command Syntax .................................................... 267
Command List ........................................................ 272
488.2 Common Commands ..................................... 277
Status Register Commands ..................................... 280
TABLE OF CONTENTS
5
System Commands ................................................. 286
Apply Commands ................................................... 288
Output Commands ................................................. 296
Pulse Configuration Commands ............................. 305
Harmonic Commands ............................................. 310
Amplitude Modulation (AM) Commands ................ 313
AM Overview .......................................................... 313
Amplitude Modulation (DSB-SC) Commands ......... 318
AM (DSB-SC) Overview .......................................... 318
Frequency Modulation (FM) Commands ................. 323
FM Overview .......................................................... 323
Frequency-Shift Keying (FSK) Commands ............... 328
FSK Overview ......................................................... 328
Phase Modulation (PM) Commands ....................... 332
PM Overview .......................................................... 332
Phase-Shift Keying (PSK) Commands...................... 336
PSK Overview ......................................................... 336
Additive Modulation (SUM) Commands ................. 339
SUM Overview ........................................................ 339
Pulse Width Modulation (PWM) Commands........... 344
PWM Overview ....................................................... 344
Frequency Sweep Commands .................................. 349
Sweep Overview ...................................................... 349
Burst Mode Commands .......................................... 360
Burst Mode Overview ............................................. 360
Arbitrary Waveform Commands .............................. 369
Arbitrary Waveform Overview ................................. 369
IQ Waveform Command.......................................... 383
IQ Waveform Overview ........................................... 383
Tracking Commands ............................................... 399
Reference Commands ............................................. 404
Save and Recall Commands .................................... 405
Error Messages ....................................................... 407
SCPI Status Registers ............................................. 419
AFG-3021/3022/3031/3032 User Manual
6
APPENDIX ................................................... 425
Fuse Replacement ................................................... 425
AFG-3021, AFG-3022, AFG-3031 & AFG-3032
Specifications ......................................................... 426
Declaration of Conformity ....................................... 434
ARB Built-In Waveforms .......................................... 435
IQ Waveform Mapping ............................................ 447
INDEX ......................................................... 455
TABLE OF CONTENTS
7
SAFETY INSTRUCTIONS
This chapter contains important safety instructions
that should be followed when operating and
storing the function generator. Read the following
before any operation to ensure your safety and to
keep the function generator in the best condition.
Safety Symbols
These safety symbols may appear in this manual or on the
instrument.
WARNING
Warning: Identifies conditions or practices that
could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that
could result in damage to the function generator or
to other objects or property.
DANGER High Voltage
Attention: Refer to the Manual
Signal ground. Chassis ground
Signal ground. Isolated from other channels and
ground.
Do not dispose electronic equipment as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased.
AFG-3021/3022/3031/3032 User Manual
8
Safety Guidelines
Do not place heavy objects on the instrument.
Do not place flammable objects on the
instrument.
Avoid severe impact or rough handling that
may damage the function generator.
Avoid discharges of static electricity on or near
the function generator.
Use only mating connectors, not bare wires, for
the terminals.
The instrument should only be disassembled by
a qualified technician.
Do not apply more than 42Vpk to any
input/output ground or to the chassis ground.
Do not apply voltage to the output terminals to
avoid damage to the instrument.
To avoid damage to the instrument, do not
apply beyond the range of 0 ~ 5V to the trigger
input terminal.
To avoid damage to the instrument, do not
apply beyond the range of -5 ~ +5V to the MOD
input terminal.
(Measurement categories) EN 61010-1:2010 specifies the
measurement categories and their requirements as follows. The
AFG-30XX falls under category II.
Measurement category IV is for measurement performed at the
source of a low-voltage installation.
Measurement category III is for measurement performed in a
building installation.
Measurement category II is for measurement performed on
circuits directly connected to a low voltage installation.
Measurement category I is for measurements performed on
circuits not directly connected to Mains.
SAFETY INSTRUCTIONS
9
Power Supply
WARNING
AC Input voltage: 100 - 240V AC, 50 - 60Hz.
Connect the protective grounding conductor of
the AC power cord to an earth ground to
prevent electric shock.
Fuse
WARNING
Fuse type:
AFG-3032&3022: T1A/250V
AFG-3031&3021: T0.63A/250V
Only qualified technicians should replace the
fuse.
To ensure fire protection, replace the fuse only
with the specified type and rating.
Disconnect the power cord and all test leads
before replacing the fuse.
Make sure the cause of the fuse blowout is fixed
before replacing the fuse.
Ground
CAUTION
The AFG-30XX is a floating function generator;
the AFG-30XXs’ common ground is electrically
isolated from the chassis ground by a 42Vpk
isolation voltage (DC + peak AC). Exceeding
42Vpp may cause damage to the internal
circuits.
Do not short the chassis ground with
CH1(MAIN)’s or CH2’s common ground if
there is a potential voltage difference between
them. Doing so may damage the unit or
externally connected equipment.
If there is a potential voltage between CH1’s and
CH2’s common ground, do not short them.
Doing so may damage the unit or externally
connected equipment.
WARNING
To avoid electric shock ensure that the output
voltage and floating voltage does not exceed
42Vpk in total.
Do not touch any exposed connectors when the
unit is being operated.
AFG-3021/3022/3031/3032 User Manual
10
Cleaning the
function
generator
Disconnect the power cord before cleaning the
function generator.
Use a soft cloth dampened in a solution of mild
detergent and water. Do not spray any liquid
into the function generator.
Do not use chemicals containing harsh products
such as benzene, toluene, xylene, and acetone.
Operation
Environment
Location: Indoor, no direct sunlight, dust free,
almost non-conductive pollution (Note below)
and avoid strong magnetic fields.
Relative Humidity: < 80%
Altitude: < 2000m
Temperature: 0°C to 40°C
(Pollution Degree) EN 61010-1:2010 specifies pollution degrees and
their requirements as follows. The function generator falls under
degree 2.
Pollution refers to “addition of foreign matter, solid, liquid, or
gaseous (ionized gases), that may produce a reduction of dielectric
strength or surface resistivity”.
Pollution degree 1: No pollution or only dry, non-conductive
pollution occurs. The pollution has no influence.
Pollution degree 2: Normally only non-conductive pollution
occurs. Occasionally, however, a temporary conductivity caused
by condensation must be expected.
Pollution degree 3: Conductive pollution occurs, or dry, non-
conductive pollution occurs which becomes conductive due to
condensation which is expected. In such conditions, equipment
is normally protected against exposure to direct sunlight,
precipitation, and full wind pressure, but neither temperature
nor humidity is controlled.
Storage
environment
Location: Indoor
Relative Humidity: < 70%
Temperature: -10°C to 70°C
SAFETY INSTRUCTIONS
11
Disposal
Do not dispose this instrument as unsorted
municipal waste. Please use a separate collection
facility or contact the supplier from which this
instrument was purchased. Please make sure
discarded electrical waste is properly recycled to
reduce environmental impact.
Class A Device
WARNING
The AFG-30XX function generators are categorized
as Class A equipment. Class A equipment is
intended for use in an industrial environment.
Class A equipment may have potential difficulties
in ensuring electromagnetic compatibility in other
environments, due to conducted as well as
radiated disturbances.
AFG-3021/3022/3031/3032 User Manual
12
Power cord for the United Kingdom
When using the function generator in the United Kingdom, make sure the
power cord meets the following safety instructions.
NOTE: This lead/appliance must only be wired by competent persons
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in this lead are coloured in accordance with the
following code:
Green/ Yellow:
Earth
Blue:
Neutral
Brown:
Live (Phase)
As the colours of the wires in main leads may not correspond with the
coloured marking identified in your plug/appliance, proceed as follows:
The wire which is coloured Green & Yellow must be connected to the Earth
terminal marked with either the letter E, the earth symbol or coloured
Green/Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is
marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal
marked with the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or contact
the supplier.
This cable/appliance should be protected by a suitably rated and approved
HBC mains fuse: refer to the rating information on the equipment and/or
user instructions for details. As a guide, a cable of 0.75mm2 should be
protected by a 3A or 5A fuse. Larger conductors would normally require
13A types, depending on the connection method used.
Any exposed wiring from a cable, plug or connection that is engaged in a
live socket is extremely hazardous. If a cable or plug is deemed hazardous,
turn off the mains power and remove the cable, any fuses and fuse
assemblies. All hazardous wiring must be immediately destroyed and
replaced in accordance to the above standard.
GETTING STARTED
13
GETTING STARTED
The Getting started chapter introduces the
function generator’s main features, appearance, set
up procedure and power-up.
Note: Throughout this manual, “AFG-30XX”
refers to the AFG-3021, AFG-3022, AFG-3031 &
AFG-3032, unless stated otherwise.
Main Features
Model name
Frequency
bandwidth
Channels
AFG-3021
20MHz
1(signal ground chassis isolation)
AFG-3022
20MHz
2 (signal ground chassis isolation and
channel isolation)
AFG-3031
30MHz
1(signal ground chassis isolation)
AFG-3032
30MHz
2 (signal ground chassis isolation and
channel isolation)
Performance
DDS Function Generator series
1μHz high frequency resolution maintained at
full range
1ppm frequency stability
Full Function Arbitrary Waveform Capability
-250 MSa/s sample rate
-125 MSa/s repetition rate
-8 M-point waveform length
-16-bit amplitude resolution
AFG-3021/3022/3031/3032 User Manual
14
-Ten 8 M waveform memories
-True waveform output to display
-User define output section
-D W R (Direct Waveform Reconstruction)
capability
-Waveform editing capability sans PC
-N Cycle and Infinite output mode selectable
-60dBc low distortion sine wave
Features
Sine, Square, Triangle, Pulse, Ramp, Noise, DC
standard waveforms
IQ baseband waveform (AFG-3032/AFG-3022
only)
Int/Ext AM, AM (DSB-SC), FM, PWM, FSK,
PM, PSK, SUM modulation
Modulation/sweep signal output
Burst function with internal and external
triggers
Store/recall 10 groups of setting memories
Output overload protection
Two channel tracking (AFG-3022/3032 only)
42Vpk signal ground chassis isolation and
42Vpk channel isolation
Multi-unit synchronized control
DSO Link function to transfer captured
waveforms from the DSO to the function
generator
Harmonic waveform function
Pulse waveform with configurable rise times &
fall times
Frequency and amplitude sweep
GETTING STARTED
15
Interface
Interface: Standard: LAN, USB Optional: GPIB
4.3 inch color TFT LCD (480 × 272) Graphical
User Interface
AWES (Arbitrary Waveform Editing Software)
PC software
AFG-3021/3022/3031/3032 User Manual
16
Panel Overview
Front Panel
AFG-3021/3031
Arbitrary Function Generator
AFG-3031
OUTPUT
Waveform FREQ/Rate AMPL DC Offset UTIL
Preset
0
7 8 9
4 5 6
1 2 3
/
Output
F 1 F 2 F 3 F 4 F 5 F 6 ARB MOD Sweep Burst
MAIN 50W
50W
MOD
SYNC
MAIN
42V
MAX
42V
MAX
42V
MAX
LCD Display Number
pad
Scroll Wheel
Output
Terminals
Function keys USB port
Output
indicators
Output key
Selection
keys
Power
Switch
Operation
keys
AFG-3022/3032
CH2
CH1
Output
Arbitrary Function Generator
AFG-3032
OUTPUT
Waveform FREQ/Rate AMPL DC Offset UTIL
Preset
0
7 8 9
4 5 6
1 2 3
/
Output
F 1 F 2 F 3 F 4 F 5 F 6 ARB MOD Sweep Burst
CH1 50W
50W
SYNC
CH2
CH1
42V
MAX
W
42V
MAX
42V
MAX
50
CH1/CH2
CH2
LCD Display Number
pad
Scroll Wheel
Output
Terminals
Function keys USB port
Output
indicators
Output key
Selection
keys
Power
Switch
Operation
keys
LCD display
TFT color LCD display, 480 x 272 resolution.
Function keys:
F1~F6
F 1
Activates the functions which
appear in the bottom of the LCD
display.
GETTING STARTED
17
Operation keys
Waveform
Waveform is used to select a
waveform type.
FREQ/Rate
The FREQ/Rate key is used to set
the frequency or sample rate.
AMPL
AMPL sets the waveform
amplitude.
DC Offset
Sets the DC offset.
UTIL
The UTIL key is used to access the
save and recall options, set the
remote interface (USB, GPIB,
LAN), use DSO link (AFG-
3021/3031), update and view the
firmware version, access the
calibration options, output
impedance settings (AFG-
3021/3031 only), set the language
and access the help menu.
ARB
ARB is used to set the arbitrary
waveform parameters.
MOD
Sweep
Burst
The MOD, Sweep and Burst keys
are used to set the modulation,
sweep and burst settings and
parameters.
Preset
Preset
The preset key is used to recall a
preset state.
Main Output
(AFG-3021/3031)
Output
MAIN
The Output key is used to turn on
or off the waveform output.
CH1/CH2
Output
(AFG-3022/3032)
Output
CH1
CH1/CH2 Output key. These
keys are used to turn the output
on or off for each individual
channel.
AFG-3021/3022/3031/3032 User Manual
18
CH1/CH2
(AFG-3022/3032)
CH1
CH2
The CH1/CH2 keys are used to
access the DSO link function,
output impedance settings and
phase settings for the AFG-3022 &
AFG-3032.
Output
indicators
OUTPUT
When an Output indicator is
green, it indicates that the output
is active.
USB host
connector
The USB Host connector is used
to save and restore data as well as
update the firmware.
Output terminals
(AFG-3021/3031)
MOD
42V
MAX
Modulation output terminal for
the AM, FM, PWM, PM, SUM or
sweep function.
50W
SYNC
42V
MAX
The SYNC output terminal
outputs a TTL logic level signal in
phase with the zero phase
position of the main output. 50Ω
output impedance.
50W
MAIN
42V
MAX
The primary output terminal. 50Ω
output impedance.
Note: The MAIN ground has a common ground
with the MOD output, SYNC and MOD input
terminals. They are also isolated from the chassis
ground and the 10MHz REF IN ground by an
isolation voltage of 42Vpk.
GETTING STARTED
19
Output terminals
(AFG-3022/3032)
SYNC
42V
MAX
50W
The SYNC output terminal
outputs a TTL logic level signal in
phase with the zero phase
position of the CH1 output. 50Ω
output impedance.
50W
CH2
42V
MAX
CH2 output terminal. 50Ω output
impedance.
50W
CH1
42V
MAX
CH1 output terminal. 50Ω output
impedance.
Note: The CH1, CH2 and 10MHz REF IN ground
are isolated from each other and from the chassis
ground by an isolation voltage of 42Vpk.
The CH1 ground has a common ground with the
MOD output, SYNC and the CH1 MOD input
terminals.
The CH2 ground has a common ground with the
CH2 MOD input terminal.
Standby key
The standby key is used to turn
the function generator on (green)
or to put the function generator
into standby mode (red).
Selection keys
Used to select digits when editing
parameters.
Scroll Wheel
The scroll wheel is used to edit
values and parameters.
Decrease Increase
Keypad
0/
321
4
7 8
5
9
6
The digital keypad is used to
enter values and parameters. The
keypad is often used in
conjunction with the selection
keys and variable knob.
AFG-3021/3022/3031/3032 User Manual
20
Rear Panel
AFG-3021/3031
WARNING
LAN
replacing fuse
Disconnect power
cord and test
leads before
100 240V
50 60Hz 50VA
AC
AC 250V
T 0.63A
FUSE RATING
GPIB
must be connected to ground.
For continued fire protection. Replace only with specified type and rated fuse.
No operator serviceable components inside.
Do not remove covers. Refer servicing to qualified personnel.
To avoid electric shock the power cord protective grounding conductor
OUT
INPUT
42V
MAX
IN
TriggerMOD
42V
MAX
REF
10MHz
GPIB, AFG-3G1(optional) Fan
OUT and IN
10MHz REF
USB portTrigger
Input
Power socket
and fuse
Power Switch
MOD
Input
LAN
AFG-3022/3032
REF
OUT
INPUT
42V
MAX
10MHz
42V
MAX
IN
WARNING
LAN
replacing fuse
Disconnect power
cord and test
leads before
100 240V
50 60Hz 85VA
AC
AC 250V
T 1A
FUSE RATING
GPIB
must be connected to ground.
For continued fire protection. Replace only with specified type and rated fuse.
No operator serviceable components inside.
Do not remove covers. Refer servicing to qualified personnel.
To avoid electric shock the power cord protective grounding conductor
42V
MAX
CH2
Trigger MOD CH1 TriggerMOD
GPIB, AFG-3G1(optional) Fan
OUT and IN
10MHz REF
CH1 MOD &
Trigger Input
Power socket
and fuse
USB port Power Switch
CH2 MOD &
Trigger Input
LAN
10MHz REF OUT
OUT
IN
42V
MAX
REF
10 MHz reference output.
10MHz REF IN
10 MHz reference input.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328
  • Page 329 329
  • Page 330 330
  • Page 331 331
  • Page 332 332
  • Page 333 333
  • Page 334 334
  • Page 335 335
  • Page 336 336
  • Page 337 337
  • Page 338 338
  • Page 339 339
  • Page 340 340
  • Page 341 341
  • Page 342 342
  • Page 343 343
  • Page 344 344
  • Page 345 345
  • Page 346 346
  • Page 347 347
  • Page 348 348
  • Page 349 349
  • Page 350 350
  • Page 351 351
  • Page 352 352
  • Page 353 353
  • Page 354 354
  • Page 355 355
  • Page 356 356
  • Page 357 357
  • Page 358 358
  • Page 359 359
  • Page 360 360
  • Page 361 361
  • Page 362 362
  • Page 363 363
  • Page 364 364
  • Page 365 365
  • Page 366 366
  • Page 367 367
  • Page 368 368
  • Page 369 369
  • Page 370 370
  • Page 371 371
  • Page 372 372
  • Page 373 373
  • Page 374 374
  • Page 375 375
  • Page 376 376
  • Page 377 377
  • Page 378 378
  • Page 379 379
  • Page 380 380
  • Page 381 381
  • Page 382 382
  • Page 383 383
  • Page 384 384
  • Page 385 385
  • Page 386 386
  • Page 387 387
  • Page 388 388
  • Page 389 389
  • Page 390 390
  • Page 391 391
  • Page 392 392
  • Page 393 393
  • Page 394 394
  • Page 395 395
  • Page 396 396
  • Page 397 397
  • Page 398 398
  • Page 399 399
  • Page 400 400
  • Page 401 401
  • Page 402 402
  • Page 403 403
  • Page 404 404
  • Page 405 405
  • Page 406 406
  • Page 407 407
  • Page 408 408
  • Page 409 409
  • Page 410 410
  • Page 411 411
  • Page 412 412
  • Page 413 413
  • Page 414 414
  • Page 415 415
  • Page 416 416
  • Page 417 417
  • Page 418 418
  • Page 419 419
  • Page 420 420
  • Page 421 421
  • Page 422 422
  • Page 423 423
  • Page 424 424
  • Page 425 425
  • Page 426 426
  • Page 427 427
  • Page 428 428
  • Page 429 429
  • Page 430 430
  • Page 431 431
  • Page 432 432
  • Page 433 433
  • Page 434 434
  • Page 435 435
  • Page 436 436
  • Page 437 437
  • Page 438 438
  • Page 439 439
  • Page 440 440
  • Page 441 441
  • Page 442 442
  • Page 443 443
  • Page 444 444
  • Page 445 445
  • Page 446 446
  • Page 447 447
  • Page 448 448
  • Page 449 449
  • Page 450 450
  • Page 451 451
  • Page 452 452
  • Page 453 453
  • Page 454 454
  • Page 455 455
  • Page 456 456

GW Instek AFG-303x User manual

Category
Power generators
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI