Introduction
Button functions
LCD Icon description
Technical specication
Product compliance
Safety Information
Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU.
Full information is available on the website www.saluslegal.com
RT510 / RT510RF is a programmable room thermostat used to control room temperature. Device
launching heating system by shorting terminal blocks, simultaneously informing the action and
showing this information on the LCD display. Extended features allows us to use various operating modes
- automatic (time schedules), manual, frost protection or holiday. Before use please read this manual
carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot
located under the cover. Do not use rechargeable batteries.
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualied person in accordance to national
and EU regulations.
RT510/RT510TX Thermostat RXRT510 Receiver
1
67
89
4
3
25
1. Boost function
2. Manual Mode
3. Frost protection / Holiday Mode
4. Increase button
5. Decrease button
6. When in Manual Mode,
ON will turn the boiler on.
7. When in Manual Mode,
OFF will turn the boiler o.
8. Receiver operates in automatic mode
according to the thermostat
9. Receiver output is controlled
by the On/O slide switch.
1. Day of the week
2. Program number
3. Program indicator
4. Settings
5. Temperature measured / set
6. Boost function
7. Low battery status
8. Wireless connection with the receiver
9. Heating Mode On
10. Manual Mode On
11. Holiday Mode On
12. Frost Protection Mode On
13. Temperature unit
14. AM / PM
15. Clock
2
3 5 6
4
1
15 14 1213
8
9
11
7
10
RT510 Thermostat RT510TX Thermostat
Thermostat supply 2 x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max 3 (1) A -
Outputs
Voltage free
NO / COM / NC
terminals
-
Temperature range 5 - 35°C 5 - 35°C
Temperature accuracy 0.1°C or 0.5°C 0.1°C or 0.5°C
Hysteresis ±0.25°C or ±0.5°C ±0.25°C or ±0.5°C
Radio frequency - 868 MHz
Dimension [mm] 120x96x27 120x96x27
RXRT510 Receiver
Receiver supply 230 V AC
Receiver rating max 16 (5) A
Outputs Voltage free NO / COM terminals
Radio frequency 868 MHz
Dimension [mm] 96x96x27
Importer:
SALUS Controls plc
Salus House, Dodworth Business Park
Whinby Road, Barnsley S75 3SP,
United Kingdom
DISTRIBUTOR OF SALUS CONTROLS:
QL CONTROLS Sp. z o.o., Sp. k.
Rolna 4,
43-262 Kobielice,
Poland
www.salus-controls.eu
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specification, design and materials of products listed in this brochure without prior notice.
Installation Manual
Model: RT510 (Wired, electronic thermostat - programmable)
RT510RF (Wireless, electronic thermostat - programmable)
DIP Switch Settings
The DIP switches are found on the rear of your thermostat.
The DIP switch number 1 is used to change the schedule mode: 5-2
mode (business days + weekend) or for each day separately mode.
DIP switch number 2 is used to change the span (temperature
accuracy) of your thermostat from the default ±0.5°C to ±0.25°C.
This may cause your boiler to operate more frequently.
RT510 Wiring diagram
L
L
L
COM
Thermostat
RT510TX
NO
N
N
N
L
L
M
N
N
M
COM
NO
COM
NO
NC
COM
NO
NC
or
MAX
3 (1) A
or
Receiver
RXRT510
AC 230 V
AC 230 V
AC 230 V
Receiver
RXRT510
MAX
16 (5) A
Thermostat
RT510
Thermostat
RT510TX
Thermostat
RT510
OR
L
L
L
COM
Thermostat
RT510TX
NO
N
N
N
L
L
M
N
N
M
COM
NO
COM
NO
NC
COM
NO
NC
or
MAX
3 (1) A
or
Receiver
RXRT510
AC 230 V
AC 230 V
AC 230 V
Receiver
RXRT510
MAX
16 (5) A
Thermostat
RT510
Thermostat
RT510TX
Thermostat
RT510
RT510
Thermostat
RT510
Thermostat
RT510RF Wiring diagram
Setting the time
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
L
L
L
COM
Thermostat
RT510TX
NO
N
N
N
L
L
M
N
N
M
COM
NO
COM
NO
NC
COM
NO
NC
or
MAX
3 (1) A
or
Receiver
RXRT510
AC 230 V
AC 230 V
AC 230 V
Receiver
RXRT510
MAX
16 (5) A
Thermostat
RT510
Thermostat
RT510TX
Thermostat
RT510
L
L
L
COM
Thermostat
RT510TX
NO
N
N
N
L
L
M
N
N
M
COM
NO
COM
NO
NC
COM
NO
NC
or
MAX
3 (1) A
or
Receiver
RXRT510
AC 230 V
AC 230 V
AC 230 V
Receiver
RXRT510
MAX
16 (5) A
Thermostat
RT510
Thermostat
RT510TX
Thermostat
RT510
OR
RT510TX
Thermostat
RT510TX
Thermostat
RXRT510
Receiver
RXRT510
Receiver
RT510 Terminals description
RXRT510 Receiver terminals description
Terminal Description
1 - COM Common Terminal
2 - NC Switched Live OFF
3 - NO Switched Live ON
Terminal Description
NO Switch Terminal
COM Common Switch Terminal
L, N Supply (230 V AC)
NO COM L N
24H
5-2
+/-0.25°C
+/-0.5°C
ON
12
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
1
3
5
7
9
Press or to select the hour format.
Press the buttons SELECT and SET
together for 3 sec.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SET to conrm.
Press or to set the hour.
Press or to set the minutes.
Press or to set day of the week.
Thermostat will return to the main screen.
3 sec 3 sec
I 2018
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
Programming - automatic mode
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
2
4
6
8
10
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
1
3
5
7
9
Use the or button to select day / days
from which you want to start programming.
Use the or button to set the hour
to start the program #1.
Use the or button to set the minutes
to start the program #1.
Use the or button
to set the temperature for program #1.
Follow steps 4-9,
to dene programs 2-6.
Press SET button to end programming.
Press the SET button to start programming.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
In this mode, user can set the schedules for thermostat (temperature setpoints for specic periods of
time). To do this, rstly choose programming mode: “5-2” (business days + weekend) or “24h” (each
day separately) using DIP switch no. 1. Programmed schedules should use all time periods.
Temporary Override mode
Hourly temperature Override Mode (+Hr)
RT510TX thermostat pairing with the receiver Installer mode
Reset of the RT510 thermostat
Reset of the RT310TX thermostat
Manual Mode and setting setpoint temperature
Frost Protection
Sleep mode
Holiday Mode
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
2
4
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
1
3
Using or button set a new setpoint
temperature for override.
(the pairing process takes up to 9 minutes)
Using or buttons set new setpoint
temperature.
Press three buttons at the same time
for 3 seconds.
Use or button to set the number
of days for Holiday Mode.
Using or buttons set new setpoint
temperature.
Press +Hr button to set number of hours for
temperature override (e.g. to set up override
for 3 hours, press the button 3 times).
Press and hold TEST/PAIRING button
for 3 seconds.
Once devices are successfully paired,
LED on the receiver will go solid red.
Press and hold TEST / PAIRING button for
3 seconds to end the pairing process.
Press TEST / PAIRING button
to check the connection with
the receiver.
Press TEST / PAIRING button
again to return to the main
screen.
Press the + Hr button until number of hours
disappears from display.
Press button to activate the Manual Mode.
Hold down button for 3 seconds
to activate the Holiday Mode.
Press button to turn On Frost
Protection mode.
Press button again to turn
O Frost Protection mode.
Press SET button
to conrm.
Press SET button to conrm.
You can set up to 31 days.
Using SELECT button choose the parameter.
Press SET to conrm.
Press SELECT to conrm.
Using or buttons set a parameter value.
Follow steps 2-5, to set next parameters.
To exit the installer mode, wait 10 seconds
- thermostat will return automatically
to the main screen.
Press any key to deactivate sleep mode. Thermostat will return to the previous mode.
Thermostat is in sleep mode.
After new setpoint temperature set,
thermostat will return to the main screen.
After new setpoint temperature set,
thermostat will return to the main screen.
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
This function is available only in automatic mode (schedule). If a new setpoint temperature will be set
during the schedule - it will be maintained until next time interval starts according to programmed
schedule.
In this mode thermostat does not work according to the programmed schedule but it will maintain
selected temperature.
In this mode the “frost protection” temperature is maintained for a specic number of days.
This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature
for a specied number of hours (up to 9 hours). Once that time is over, thermostat returns to previous
mode.
Turning o hourly temperature override mode before time’s up
Turning O the Frost Protection mode
Begin the pairing process
End the pairing process
Test the pairing process
Temporary Override mode will be disabled when new schedule will be set.
To turn o the Manual Mode press button. Once the manual mode is o, the hand icon on
the thermostat will disappear.
To turn o the Holiday Mode, hold down button for 3 seconds. The airplane icon should
disappear from the display.
If you purchased an RXRT510 or RT510TX and intend pairing with other devices in the 5x5 range, please
refer to the Receiver Units manual or the relevant manuals available at www.salus-controls.eu
Temperature of the Frost Protection mode is set as default at 5°C. This temperature can be changed
in Installer Mode in d03 parameter.
When you want to change the batteries
your device will use the internal memory to
backup your settings. You have 30 seconds
to change the batteries before losing your
settings.
When the sleep mode is activated, all thermostat functions are paused.
If you bought the RT510TX and RXRT510 seperately then pair as follows. Please make sure that
receiver switchers are set on AUTO and ON position. Connect your receiver to power supply - LED
indicator will ash red.
Press the RESET button once. You can use a paper
clip. Your thermostat will be reset and will start up
automatically.
Remove the batteries without pressing any button.
Wait 2 minutes and insert the batteries again.
Your device will be restarted.
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
2
2
4
4
1
1
3
3
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
3 sec
3 sec
3 sec
3 sec
3 sec
3 sec
TEST / PAIRING
SELECT SET
ON
AUTO
OFF
MANUAL
ON
AUTO
OFF
MANUAL
dxx Function Parametr Default
value
d01 Temperature display increments 0.1°C or 0.5°C 0.5°C
d02 Temperature oset +/- 3.0°C 0.0°C
d03 Frost Protection setpoint temperature 5.0°C - 17.0°C 5.0°C
RESET
SELECT SET
TEST / PAIRING
SELECT
+ −
+ −
SET
1 sec
1 sec
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
3
3 sec
3 sec
Hold and buttons simultaneously
for 3 seconds to start the sleep mode.
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
2
4
6
1
3
5
TEST / PAIRING
SELECT SET
TEST / PAIRING
SELECT SET
  • Page 1 1
  • Page 2 2

Salus RT510RF Installation guide

Category
Thermostats
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI