Signify CB100 Step Light, HADCO CB100 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Signify CB100 Step Light Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
6"
6"
INSIDE HOUSING
MOUNTED FROM
THERMAL PROTECTOR
TRAY SCREW
FACE PLATE
ELECTRICAL TRAY
HOUSING
MOUNTING SCREW
TO REMOVE
(IF SUPPLIED)
REMOVE LAMP
MOUNTING
SCREW
Make sure power is off before installing or servicing this fixture.
Remove face plate by loosening 4 philips screws on front of louver.
Remove electrical tray by loosening one philips screw.
Install housing per instructions on following page, according to specific mounting application: New stud wall,
Existing stud wall, Masonry wall, or concrete pour installation.
For interior or exterior, new or existing walls of plasterboard or wood, a thermal protector is required and insulation
is to be a minimum of 6 inches away from sides of housing. Install thermal protector by removing 1 inch snap-in plug
and pushing protector through hole from inside housing.
Thermal protection is not required for masonry or concrete pour installations. Thermal protection is also not
required for fluorescent lampings since the Recessed Bricklyte ballast is class P and contains thermal protection.
Re-assemble fixture.
Turn power ON.
GFI PROTECTION! Fixtures which may come in contact with or be exposed to moisture (i.e. outdoors) shall be
installed on a GFI (Ground Fault Interruptor) protected circuit.
This system is intended for installation in accordance with the National Electrical Code and local code
specifications.Failure to adhere to these codes and instructions may result in serious injury and/or damage to the
fixture, and will void HADCO's warranty. These instructions cover most installation applications. For any special
applications not covered, please contact HADCO for assistance.
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING THIS FIXTURE.
32000896, revision E
INSTALLATION INSTRUCTIONS:
CB100 BRICKLYTE
This fixture is intended for installation in accordance with the National Electrical Code and local code
specifications. Failure to adhere to these codes and instructions may result in serious injury and/or damage
to the ballast and void the warranty. These instructions do not purport to cover all details or variations in
equipment, nor to provide for every possible contingency related to installation, operation, maintenance,
or mounting situation. Should specific problems occur that are not addressed by these instructions, contact
your Sales Representative or distributor for assistance. Retain these instructions for future reference.
page 1 of 3
www.hadco.com
Signify North America Corporation
200 Franklin Square Drive
Somerset, NJ 08873, USA
Phone: 855-486-2216
Signify Canada Ldt./ Signify Canada Ltée
281 Hillmount Road
Markham ON, Canada L6C 2S3
Phone: 800-668-9008
STUD
FINISHING RING &
SCREW LOCATIONS (4)
2 ON BOTTOM
EACH SIDE &
PLUG, 1 ON
1/2-14 NPT
(MOUNTEDFROM INSIDE
HOUSING)
THERMAL PROTECTOR
FINE ADJUSTMENT
SLOT
CROSS BRACKETS
L-BRACKETS (4)
CROSS BRACKET TAB
WALL BOARD
THICKNESS
(NAILS SUPPLIED
BY CUSTOMER)
+ 1/8 INCH
FLAG
TEMPLATE
HOLE
EACH SIDE &
1/2-14 NPT
2 ON BOTTOM
PLUG, 1 ON
FASTENER
THERMAL
MOUNTING
SCREWS &
SCREW HOLES
PROTECTOR
(MOUNTED FROM
INSIDE HOUSING)
"L" BRACKETS
MASONRY BRACKET
LOWER
1/2-14 NPT PLUG
1 ON EACH SIDE &
2 ON BOTTOM
WASHER,
BRACKET
SCREW,
BRACKET
HOLES
MORTAR
FRONT OF
HOUSING
EXTENDS PAST
BRICK 1/8 INCH
Install two screws through washers and lower masonry
brackets and into tapped housing holes on bottom of
fixture.
Remove the 1/2" NPT plugs from the side/bottom of the
housing and pull supply wires through holes and into
housing.
Leaving 1/8" of housing extending past front of wall,
press fixture and lower masonry brackets into a layer of
mortar so that the mortar penetrates through the holes
of the masonry brackets.
After laying another course of blocks, install the two
upper masonry brackets onto the housing as above.
(USE ACCESSORY KET #MAKM)
INSTALLATION FOR MASONRY WALL
Using the template supplied, cut a level hole through the
existing wall between existing studs. Failure to level
the hole will cause the fixture to have a tilted appearance.
Push the four mounting screws through the housing holes
and into rear channels. (NOTE: A thin membrane covers
the housing holes and may require forcing the screws
through to penetrate the membrane.
Place flags flat on rear of housing and thread screws
into flags until the screws are completely through the flags.
Install four "L" brackets on housing with four screws.
Remove the 1/2" NPT plugs from the side/bottom of the
housing and pull the supply wires through into the housing.
Push housing into the hole in the wall and tighten four
mounting screws until the flag fasteners have drawn tightly
up against the rear surface of the wall.
Install thermal protector.
(USE ACCESSORY KET #MAKEC)
INSTALLATION FOR EXISTING STUD WALL
Using the template supplied, cut a level hole through
the wall board to fit around the fixture housing. Failure
to level the hole will cause the fixture to have a tilted
appearance.
Mount "L" brackets onto housing 4 places with screw
positioned in center of slot, and insert cross brackets
through the "L" brackets on top and bottom of housing.
Position fixture so that the housing extends past the
studs the thickness of the wallboard plus 1/8 inch.
Level fixture and hammer tabs on cross brackets into
studs, then nail brackets securely to studs.
Fine adjust fixture position and tighten all loose screws.
Remove the 1/2" NPT plugs from the side/bottom of the
housing and pull supply wires through holes and into
housing.
Install wall board.
Install thermal protector.
(USE ACCESSORY KET #MAKNS)
INSTALLATION FOR NEW STUD WALL
page 2 of 3
32000896, revision E
2
"
5.75
"
1/8"
NOTE: LEVEL TEMPLATE BEFORE
DRILLING OR CUTTING
EXISTING CONSTRUCTION CUTOUT TEMPLATE
8 1/4" X 2 3/4" (ACCESSORY KIT #MAKEC)
(4) 3/16" DIA. HOLES
FOR CONCRETE POUR
THIS SIDE UP
BRICKLYTE
Level supplied template on wood support frame and drill
four 3/16" diameter clearance holes. Failure to level will
cause fixture to have a tilted appearance.
Remove the 1/2" NPT plugs from the side/bottom of the
housing and pull the supply wires through the holes and
into the housing.
Be sure all unused electrical plugs have been replaced.
Using template, cut 1/8" deep outline into back of wood
support.
Secure housing to wood support with screws supplied in
hardware pack. Housing must extend 1/8" past front of
finished wall.
Pour concrete.
After concrete is dry, remove 4 screws and wood support.
(HARDWARE INCLUDED WITH FIXTURE)
INSTALLATION FOR CONCRETE POUR
TEMPLATE
FOUR WASHERS
& 8-32 X 2"
LONG SCREWS
FIXTURE BOTTOM
PLUGS, 1 ON EACH
SIDE, 2 ON
1/2-14 NPT
MOUNTING SCREW HOLE
FIXTURE BOTTOM
PLUGS, 1 ON EACH
SIDE, 2 ON
1/2-14 NPT
LOCATIONS (4 PLC.)
MOUNTING SCREW HOLE
page 3 of 3
32000896, revision E
/