luminii Solo 11 Surface Installation guide

Type
Installation guide

This manual is also suitable for

© 2020 Precision Lighting Ltd. We reserve the right to change details of design, materials and nish. Version 11.20
instruction manual
Solo 11, 16 & 16 Plus series
Surface Mounted
Constant Current
Solo 11 4.2W 405lm
Solo 16 8.4W 700lm
Solo 16 Plus 12.6W 1245lm
These instructions cover procedures for all
surface mounted versions of Solo 11, 16 & 16
Plus series.
1. All systems must be installed by
a suitably qualied professional
only. Installations must conform to
national installation and accident
prevention regulations.
2. Do not install any xture closer
than 150mm from any combustible
material. Do not install these
products in a damp or wet location.
3. To reduce the risk of re and burns,
do not install these products where
exposed bare conductors can be
shorted or contact any conductive
materials. Do not conceal or extend
exposed conductors through a
building wall.
4. Ensure all connections are tight. Bad
connections can cause overheating,
arcing and a potential re risk.
5. Always use appropriate optics and
ensure they are tted securely.
6. Use only as described in this
Precision Lighting manual.
7. Use only Precision Lighting
recommended accessories.
8. Ensure that the luminaire is switched
off at mains supply before installing
or removing.
9. Luminaires may be extremely hot,
allow to cool before touching.
10. These are LED luminaires, they must
be connected to an appropriate
PSU.
11. Regular cleaning of these products
is important. Switch off at mains
supply and allow to cool before
touching. Clean ttings with a soft
damp cloth and allow to dry before
reconnecting power supply
33
ABC
D
Solo 11 & 16
E F
Solo 16 Plus
AB
G
accessory holder (sold separately)
H I J
KEY PRODUCT FEATURES
A 2 x Screws
B Luminaire Body
C Microlens
D Microlens Cap
E Optic
F Optic Cap
G Snoot
H Accessory (up to 2)
I Accessory Clip
J Double Accessory Holder
03.20
Eldoled 20W 1-10V
Eldoled 30W 1-10V
Eldoled 20W DALI
Eldoled 30W DALI
Eldoled 20W 1-10V
Eldoled 30W 1-10V
Eldoled 20W DALI
Eldoled 30W DALI
COMPATIBLE
POWER SUPPLY
PSCC-20-350-A-EL
PSCC-30-350-A-EL
PSCC-20-350-D-EL
PSCC-30-350-D-EL
PSCC-20-700-A-EL
PSCC-30-700-A-EL
PSCC-20-700-D-EL
PSCC-30-700-D-EL
ORDER CODE
-
-
-
-
2
3
2
3
2
3
2
3
-
-
-
-
-
-
-
-
1
2
1
2
MAX 16 SERIES
LUMINAIRE QTY
MAX 11 SERIES
LUMINAIRE QTY
MAX 16 PLUS SERIES
LUMINAIRE QTY
© 2020 Precision Lighting Ltd. We reserve the right to change details of design, materials and nish. Version 11.20
33
These instructions are applicable to all
luminaires including:
Solo 11 - Surface
Solo 16 - Surface
Solo 16 Plus - Surface
WARNING
Do not exceed maximum number of
luminaires per driver wattage rating, see
driver datasheet for details.
Remote access required for driver.
WARNING mains supply to driver must
be OFF before connecting or disconnecting
fittings. Do not connect or disconnect
under load.
Ensure driver has not been powered for a
minimum of 1 minute before reconnecting
the LED module after disconnecting.
Do not hot plug. Failure to follow this
WARNING 1-2 luminaires per DRIVER WARNING 1-2 luminaires per DRIVER
instruction will lead to serious damage
of the LED module and driver and will
not be covered by warranty.
NOTE Wire specication: 22 AWG,
ø0.65mm diameter double insulated
teon wire.
Red - Positive Black - Negative
1. Connect Solo luminaires in series to
the driver LED outlet.
Maintain correct polarity when wiring.
Incorrect wiring will cause serious
damage and will not be covered by
warranty. Must be installed according to
SELV regulations.
2. Wire 1-10V or DALI control to LED
driver.
Maintain correct polarity when wiring
dimming control wire. Incorrect wiring
will cause serious damage and will
not be covered by warranty. Must be
installed according to SELV regulations.
1. All systems must be installed by a suitably
qualied professional only. Installations
must conform to national installation
and accident prevention regulations.
2. Ensure that the luminaire is switched off at
mains supply before installing or removing.
3. Do not install these systems in a damp
or wet location, IP20 environments
only. Do not install any xture closer
than 150mm (6 inches) from any
combustible material.
4. To reduce the risk of re and burns, do
not install these systems where exposed
bare conductors can be shorted or
contact any conductive materials. Do not
conceal or extend exposed conductors
through a building wall.
5. Ensure all connections are tight. Bad
connections can cause overheating,
arcing and a potential re risk.
6. Wire supply connections must be made
with U.L or compatible testing agency-
approved connectors. Always use
appropriate optics and ensure they are
tted securely.
7. Install and use only as described in this
Precision Lighting manual.
8. Use Precision Lighting recommended
optics and accessories only.
9. Luminaires may be hot, allow to cool
before touching.
10. Access to serviceable electrical
components should be kept available
for maintenance purposes.
11. Regular cleaning of these products is
important. Switch off at mains supply
and allow to cool before touching.
Clean ttings with a microbre cloth.
Then reconnect the power supply.
instruction manual
Solo 11 / 16 / 16 Plus Surface
Electrical Installation
350mA (11 series) or 700mA
(16 series) Constant Current
Driver.
1 -10V
/ DALI
1 -10V
/ DALI
MAINS MAINS
350mA Constant
Current Driver Output /
Secondary
Output /
Secondary
Solo 11 Surface
Solo 16 & 16 Plus
Surface
700mA Constant
Current Driver
© 2020 Precision Lighting Ltd. We reserve the right to change details of design, materials and nish. Version 11.20
8-10 mm
66 mm
1.5 mm1.5 mm 1.5 mm1.5 mm
16 mm
45 mm 8-10 mm
25.4 mm
Drilling pilot holes and wiring holes
WARNING switch off power to mains
before installation.
WARNING Do not hot plug!
Drill wiring holes for power cable ø
8-10mm.
Drill 2 pilot holes ø1.5mm for screws.
Solo 11 / 16 / 16 Plus Surface
1:1 Drilling Template
A4 Paper size
WARNING
Do not hot plug!
WARNING
Do not hot plug!
Luminaire Solo 11 diameter 45mm / Solo 16 diameter 66mm
Holes for wires diameter 8-10mm
Pilot holes for screws diameter 1.5mm
SOLO 11 SURFACE SOLO 16 / 16 PLUS SURFACE
© 2020 Precision Lighting Ltd. We reserve the right to change details of design, materials and nish. Version 11.20
1.
NOTE Model shown is the Solo 16 LED.
The same procedures apply for Solo 11
LED.
2. 3.
1. Installing the luminaire
Drill the pilot holes and the wiring hole
(See drilling template).
Tilt luminaire 90 degrees to expose holes
for screws. Use a screwdriver to tighten
screws into place.
2. Locking Pan
NOTE Only adjust luminaire position
when unlocked.
Tilt luminaire 90 degrees to expose pan
hole. Adjust luminaire to desired pan
position. To lock into place, insert hex key
provided into pan hole then rotate hex
key clockwise.
3. Removing and changing the snoot
CAUTION the luminaire may be
extremely hot. Allow to cool before
touching.
Unscrew snoot anti-clockwise to remove.
To reattach snoot, align snoot with thread
and screw on clockwise until it stops and
is secure.
4. Changing the microlens
Follow step 3 to remove the snoot.
NOTE Ensure the microlens is inserted
with smooth side / text facing outwards,
and is readable.
Unscrew the microlens cap anti-clockwise
until fully detached. Remove the microlens
and replace with alternative microlens
ensuring it is installed at.
Reattach microlens cap, screw clockwise
until it stops and is tight and secure.
To reattach snoot, align snoot with thread
and screw on clockwise until it stops and
is secure.
© 2020 Precision Lighting Ltd. We reserve the right to change details of design, materials and nish. Version 11.20
4. Changing beam angle
4A)Changing the microlens
NOTE Only applies to Solo 11 & 16 series
Follow step 2 to remove the snoot.
Unscrew the mircolens cap anti-clockwise
until fully detached.
Remove the microlens and replace with
alternative microlens ensuring it is installed
at.
NOTE Ensure the microlens is inserted
with smooth side / text facing outwards,
and text is legible.
Reattach microlens cap, screw clockwise
until it stops and is tight and secure.
Reattach snoot, screw on clockwise until it
stops and is secure.
4B)Changing the optic
NOTE Only applies to Solo 16 Plus series
Follow step 2 to remove the snoot.
Unscrew the Optic cap anti-clockwise until
fully detached.
Gently quarter turn the optic anti-
clockwise and remove.
NOTE Do not touch the exposed LED
Carefully place optic on to LED and gently
quarter turn clockwise to lock it into place.
Reattach Optic Cap, screw on clockwise
until it stops and is secure.
Reattach Snoot, screw on clockwise until it
stops and is secure.
4A).
4B).
© 2020 Precision Lighting Ltd. We reserve the right to change details of design, materials and nish. Version 11.20
5. Installing accessories using the accessory
holder
NOTE Accessory holder ts up to 2
accessories.
Place accessory inside accessory holder
and ensure it is at.
Pinch ends of the retaining clip and insert
into accessory holder to secure accessory
in place.
Insert accessory holder into snoot until it
clicks into place.
6. Changing accessories using the accessory
holder
Accessory holder ts up to 2 accessories.
Remove snoot (step 3) and remove
accessory holder from snoot.
Pinch to remove retaining clip inside
accessory holder to change accessory.
When reassembling, (step 5) ensure
all components are placed at inside
the accessory holder before securing
accessories in place using retaining clip.
Insert accessory holder into snoot until it
clicks into place.
To reattach snoot to luminaire, align snoot
with thread and screw on clockwise until it
stops and is secure.
5.
CLICK
6.
CLICK
CLICK
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

luminii Solo 11 Surface Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI