Elkay HRF_EBP_SBP_ESBP_SEBP.B Owner's manual

Type
Owner's manual

This manual is also suitable for

PAGE 1 97640C (Rev. L - 4/09)
HRF-EBP*B HRF-SBP*B HRF-SEBP*B HRF-ESBP*B
Halsey Taylor Owners Manual
Non-Refrigerated Fountains with Back Panel
To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave
these instructions inside the fountain for future reference.
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
TUBE IS
SECURED
IN POSITION
SIMPLY PUSH IN
TUBE TO ATTACH
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
FIG. 2
OPERATION OF QUICK CONNECT FITTINGS
FIG. 1
Installer
NOTE: WATER FLOW
DIRECTION
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
PAGE 297640C (Rev. L - 4/09)
HRF-EBP*B HRF-SBP*B HRF-SEBP*B HRF-ESBP*B
1. Fountains using the MPW Mounting Plate refer to Fig's. 4,6,8, or 10 for hanger bracket
location and rough-in dimensions.
NOTE: Review separate installation instructions for details of the MPW Mounting Plate.
Fountains using the Wall Plate Assy. refer to Fig's. 3,5,7, or 9 for rough-in dimensions.
2. Shown dimensions pertain to installation location (framing must support up to 150 lbs. weight
for single fountain and 300 lbs. for dual fountains). These dimensions are required for compliance
with ANSI Standard A117.0.
3. Install rough-in plumbing as shown in Fig’s. 3,4,5,6,7,8,9, or 10. Waste line should extend a
minimum of 2" (51mm) thru the back panel. Run supply water inlet line thru back panel.
Install a service stop (not provided). Turn on supply water and flush thoroughly.
4. Installing back panel.
Ftn. w/MPW Mounting Plate: Refer to Fig. 12 for placement of braces onto back panel.
Place the upper edge of the panel above hanger bracket. Slide the panel down until it engages
the hanger bracket. Be sure back panel is firmly engaged before releasing it.
Ftn. w/Wall Plate Assy.: Place the upper edge of the panel above mounting plate on the
wall. Slide the panel down until it engages the hanger. Be sure back panel is firmly engaged
before releasing it.
5. Remove bottom access panel from fountain basin and save the screws.
Ftn. w/Back Panel: Install the fountain to the back panel and wall using (4) 5/16" x 2.00" long
lag bolts and washers (NOT PROVIDED).
Ftn. w/MPW Mounting Plate: Install the fountain to the back panel and wall using (4) 5/16 “ x
6” long threaded rods, washers, and nuts (provided). Tighten securely.
Ftn. w/Wall Plate Assy.: Install the fountain to the back panel and wall using
(4) 5/16" x 3/4" long bolts and washers (provided) thru holes in back panel. Tighten securely.
6. Cut waste tube to required length using plumbing hardware and trap (provided) as a
guide. Install hardware and trap. Tighten securely.
7. Make water supply connections from service stop to the fountain strainer. Insert the
water inlet line into the inlet side of strainer until it reaches a positive stop - about 3/4"
(See Fig. 2). Turn on water supply and check for leaks. Newly installed water supply line
should be insulated after leak check is completed. DO NOT SOLDER TUBES INSERTED
INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.
8. Check stream height from bubbler. Stream height is factory set at 45-50 PSI. If supply
pressure varies greatly from this, adjust the screw on regulator, item 9 by using a small
screwdriver through the small hole in the push button item 5 (See Fig. 11).
Clockwise adjustment will raise stream height and counter-clockwise will lower stream
height. For best adjustment stream height should be approximately 1-1/2" (38mm) above
the bubbler guard. (See Figure 13)
9. These products are designed to operate on 20-105 PSIG supply line pressure. If
inlet pressure is above 105 PSIG, a pressure regulator must be installed in the supply
line. Any damage caused by reason of connecting these products to supply line
pressure lower than 20 PSIG or higher than 105 PSIG is not covered by warranty.
10. Replace bottom access panel to fountain basin using screws provided. Tighten securely.
PAGE 3 97640C (Rev. L - 4/09)
HRF-EBP*B HRF-SBP*B HRF-SEBP*B HRF-ESBP*B
FIG. 3
ROUGH-IN FOR HRF-EBP WITH WALL PLATE ASSY.
FINISHED FLOOR
LEGEND:
A = Recommended Water Supply Location 3/8" O.D. Unplated Copper
Tube Connect, Stubbed 1-1/2" (38mm) From Wall. Shut Off By Others
B = Recommended Location For Waste Outlet 1-1/4" O.D. Drain Stubbed
6-5/8" (35mm) From The Wall
C = 1-1/4" Trap Furnished
D = 3/8" (10mm) DIA. Slots For Mounting Hanger Bracket To Wall
PAGE 497640C (Rev. L - 4/09)
HRF-EBP*B HRF-SBP*B HRF-SEBP*B HRF-ESBP*B
BACK PANEL
HANGER
BRACKET
MPW101
MTG. PLT.
43 1/2"
1105mm
29 3/4"
756mm
31 1/4"
794mm
1 7/8"
48mm
8"
203mm
16"
406mm
8"
203mm
3"
76mm
A
B
C
D
5/8"
16mm
18 3/4"
476mm
FINISHED WALL
FINISHED FLOOR
27"
686mm
ADA
REQUIREMENT
ROUGH-IN FOR HRF-EBP WITH MPW101 MOUNTING PLATE
LEGEND:
A = Recommended Water Supply Location 3/8" O.D. Unplated Copper
Tube Connect, Stubbed 1-1/2" (38mm) From Wall. Shut Off By Others
B = Recommended Location For Waste Outlet 1-1/4" O.D. Drain Stubbed
6-5/8" (35mm) From The Wall
C = 1-1/4" Trap Furnished
D = 3/8" (10mm) DIA. Slots For Mounting Hanger Bracket To Wall
MPW101 MTG. PLT.
REF. SEPARATE
INSTALLATION
INSTRUCTIONS
FOR DETAILS
FIG. 4
PAGE 5 97640C (Rev. L - 4/09)
HRF-EBP*B HRF-SBP*B HRF-SEBP*B HRF-ESBP*B
FIG. 5
FINISHED FLOOR
ROUGH-IN FOR HRF-SBP WITH WALL PLATE ASSY.
LEGEND:
A = Recommended Water Supply Location 3/8" O.D. Unplated Copper
Tube Connect, Stubbed 1-1/2" (38mm) From Wall. Shut Off By Others
B = Recommended Location For Waste Outlet 1-1/4" O.D. Drain Stubbed
1-3/8" (35mm) From The Wall
C = 1-1/4" Trap Furnished
D = 3/8" (10mm) DIA. Slots For Mounting Hanger Bracket To Wall
PAGE 697640C (Rev. L - 4/09)
HRF-EBP*B HRF-SBP*B HRF-SEBP*B HRF-ESBP*B
43 1/2"
1105mm
35 3/4"
908mm
37 1/4"
946mm
FINISHED FLOOR
FINISHED WALL
5/8"
16mm
13"
330mm
33"
838mm
1 7/8"
48mm
8"
203mm
16"
406mm
8"
203mm
3"
76mm
A
B
C
D
MPW101
MTG. PLT.
BACK PANEL
HANGER BRACKET
ROUGH-IN FOR HRF-SBP WITH MPW101 MOUNTING PLATE
LEGEND:
A = Recommended Water Supply Location 3/8" O.D. Unplated Copper
Tube Connect, Stubbed 1-1/2" (38mm) From Wall. Shut Off By Others
B = Recommended Location For Waste Outlet 1-1/4" O.D. Drain Stubbed
1-3/8" (35mm) From The Wall
C = 1-1/4" Trap Furnished
D = 3/8" (10mm) DIA. Slots For Mounting Hanger Bracket To Wall
MPW101 MTG. PLT.
REF. SEPARATE
INSTALLATION
INSTRUCTIONS
FOR DETAILS
FIG. 6
PAGE 7 97640C (Rev. L - 4/09)
HRF-EBP*B HRF-SBP*B HRF-SEBP*B HRF-ESBP*B
FINISHED FLOOR
ROUGH-IN FOR HRF-SEBP WITH WALL PLATE ASSY.
LEGEND:
A = Recommended Water Supply Location 3/8" O.D. Unplated Copper
Tube Connect, Stubbed 1-1/2" (38mm) From Wall. Shut Off By Others
B = Recommended Location For Waste Outlet 1-1/4" O.D. Drain, Stubbed
6-5/8" (168mm) From The Wall
C = Recommended Location For Waste Outlet 1-1/4" O.D. Drain, Stubbed
1-3/8" (35mm) From The Wall
D = 1-1/4" Trap Furnished
E = 3/8" (10mm) DIA. Slots For Mounting Hanger Bracket To Wall
FIG. 7
PAGE 897640C (Rev. L - 4/09)
HRF-EBP*B HRF-SBP*B HRF-SEBP*B HRF-ESBP*B
LEGEND:
A = Recommended Water Supply Location 3/8" O.D. Unplated Copper
Tube Connect, Stubbed 1-1/2" (38mm) From Wall. Shut Off By Others
B = Recommended Location For Waste Outlet 1-1/4" O.D. Drain, Stubbed
6-5/8" (168mm) From The Wall
C = Recommended Location For Waste Outlet 1-1/4" O.D. Drain, Stubbed
1-3/8" (35mm) From The Wall
D = 1-1/4" Trap Furnished
E = 3/8" (10mm) DIA. Slots For Mounting Hanger Bracket To Wall
ROUGH-IN FOR HRF-SEBP WITH MPW200 MOUNTING PLATE
FIG. 8
29 3/4"
756mm
31 1/4"
794mm
35 3/4"
908mm
37 1/4"
946mm
3"
76mm
3"
76mm
BACK PANEL
HANGER BRACKET
MPW200
MTG. PLT.
43 1/2"
1105mm
3 1/4"
82mm
16"
406mm
6 5/8"
168mm
18 3/4"
476mm
32"
813mm
A
A
B
C
D
E
FINISHED WALL
5/8"
16m
m
13"
330mm
18 3/4"
476mm
FINISHED FLOOR
27"
686mm
ADA
REQUIREMENT
33"
838mm
MPW200 MTG. PLT.
REF. SEPARATE
INSTALLATION
INSTRUCTIONS
FOR DETAILS
PAGE 9 97640C (Rev. L - 4/09)
HRF-EBP*B HRF-SBP*B HRF-SEBP*B HRF-ESBP*B
ROUGH-IN FOR HRF-ESBP WITH WALL PLATE ASSY.
LEGEND:
A = Recommended Water Supply Location 3/8" O.D. Unplated Copper
Tube Connect, Stubbed 1-1/2" (38mm) From Wall. Shut Off By Others
B = Recommended Location For Waste Outlet 1-1/4" O.D. Drain, Stubbed
6-5/8" (168mm) From The Wall
C = Recommended Location For Waste Outlet 1-1/4" O.D. Drain, Stubbed
1-3/8" (35mm) From The Wall
D = 1-1/4" Trap Furnished
E = 3/8" (10mm) DIA. Slots For Mounting Hanger Bracket To Wall
FIG. 3
FIG. 9
PAGE 1097640C (Rev. L - 4/09)
HRF-EBP*B HRF-SBP*B HRF-SEBP*B HRF-ESBP*B
FINISHED WALL
FINISHED FLOOR
5/8"
16mm
13"
330mm
18 3/4"
476mm
27"
686mm
ADA
REQUIREMENT
33"
839mm
29 3/4"
756mm
31 1/4"
794mm
43 1/2"
1105mm
35 3/4"
908mm
37 1/4"
946mm
3 1/4"
82mm
16"
406mm
32"
813mm
6 5/8"
168mm
18 3/4"
476mm
3"
76mm
3"
76mm
MPW200
MTG. PLT.
E
A
A
B
C
D
HANGER BRACKET
BACK PANEL
ROUGH-IN FOR HRF-ESBP WITH MPW200 MOUNTINGPLATE
LEGEND:
A = Recommended Water Supply Location 3/8" O.D. Unplated Copper
Tube Connect, Stubbed 1-1/2" (38mm) From Wall. Shut Off By Others
B = Recommended Location For Waste Outlet 1-1/4" O.D. Drain, Stubbed
6-5/8" (168mm) From The Wall
C = Recommended Location For Waste Outlet 1-1/4" O.D. Drain Stubbed
1-3/8" (35mm) From The Wall
D = 1-1/4" Trap Furnished
E = 3/8" (10mm) DIA. Slots For Mounting Hanger Bracket To Wall
MPW200 MTG. PLT.
REF. SEPARATE
INSTALLATION
INSTRUCTIONS
FOR DETAILS
FIG. 10
PAGE 11 97640C (Rev. L - 4/09)
HRF-EBP*B HRF-SBP*B HRF-SEBP*B HRF-ESBP*B
16
2
9
7
5
6
17
10
FIG. 11
Installing Back Panel: When installing back panel assy.
(Item 22) with MPW (Mounting Plate), attach channel
braces as shown above. Remove the protective backing
from the tape installed on the braces. Line up the corre-
sponding holes in the braces and back panel and press
firmly in place.
FIG. 12
22
PAGE 1297640C (Rev. L - 4/09)
HRF-EBP*B HRF-SBP*B HRF-SEBP*B HRF-ESBP*B
PART NO.
ITEM NO.
PARTS LIST
Drain
Drain-Aztec Gold
Retaining Nut
Strainer-Beehive
Strainer-Beehive Aztec Gold
Ferrule-Tailpipe
Ferrule-Tailpipe Aztec Gold
Push Button
Push Button-Aztec Gold
Push Button Sleeve
Push Button Sleeve-Aztec Gold
Regulator Holder
Bubbler Assy
Bubbler Assy-Aztec Gold
Regulator
Cap Screw
Screw - #10-24 X .50 PHTC
Strainer
Fountain Arm-Short
Fountain Arm-Short Aztec Gold
Fountain Arm-Long
Fountain Arm-Long Aztec Gold
Bottom Cover Plate-Short
Bottom Cover Plate-Long
Back Panel HRF-SBP
Back Panel HRF-SBP Aztec Gold
Back Panel HRF-EBP
Back Panel HRF-EBP Aztec Gold
Back Panel HRF-SEBP
Back Panel HRF-SEBP Aztec Gold
Back Panel HRF-ESBP
Hex Nut
Bracket-Regulator Mounting
Tube-Poly (Cut to Length)
Assy-Bubbler Nipple
Wall Plate Assembly - HRF-SBP
Wall Plate Assembly - HRF-SEBP
Wall Plate Assembly - HRF-EBP
Wall Plate Assembly - HRF-ESBP
Edge Trim
Back Panel Assembly - HRF-EBP
Back Panel Assembly - HRF-SBP
Back Panel Assembly - HRF-SEBP
Back Panel Assembly - HRF-ESBP
Washer-Flat .339/.359ID Steel
Screw-Mach. 5/16-18 x 3/4
Hanger Bracket - HRF-EBP/SBP
Hanger Bracket - HRF-SEBP/ESBP
LK464
LK464AG
15005C
40038C
45364C
40619C
45360C
45662C
45408C
45663C
45411C
50986C
51544C
45396C
61313C
75672C
112627543890
55996C
55000604
27571C
55000612
27573C
55000661
55000665
23187C
27583C
23189C
27576C
27043C
27561C
27261C
40045C
28823C
56092C
56159C
28158C
28159C
28170C
28171C
56280C
28846C
28847C
28848C
28849C
75541C
111577243890
27089C
27090C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
NS
NS
NS
NS
DESCRIPTION
TROUBLE SHOOTING & MAINTENANCE
Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits
may be removed from the orifice with a small round file not over 1/8" diameter or small diameter wire.
CAUTION: DO NOT file or cut orifice material.
Stream Regulator: If orifice is clean, regulate flow as in “START UP” instructions above. If replacement is
necessary, see parts list for correct regulator part number.
Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an
o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while
pulling on the tubing.(See Fig. 2) To insert tubing, push tube straight into fitting until it reaches a positive
stop, approximately 3/4".
CAUTION: Cleaning of Aztec Gold Models requires special care. Outer surfaces must be cleaned
with mild detergent or a mixture of vinegar and water only, rinsed and wiped dry. Abrasive and acidic
cleaners may eventually damage the Aztec Gold finish.
FIG. 13
FIG. 14
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
SEE FIG. 13
SEE
FIG. 11
FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW.HALSEYTAYLOR.COM
21
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Elkay HRF_EBP_SBP_ESBP_SEBP.B Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI