Elkay LK4406BGE Installation guide

Type
Installation guide
PAGE 1
4406_FTN_A LK4406_FTN_A
1000004375 (Rev. B - 07/18)
Owners Manual
Model 4406
Wall Mounted Tubular Fountain
4406 Fountains are among the easiest to install Fountains on the market today.
To assure you install these models easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR
INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER
APPLICABLE CODES. After installation, leave these instructions with the Fountain for
future reference.
INSTALLER
PAGE 21000004375 (Rev. B - 07/18)
4406_FTN_A LK4406_FTN_A
1. The fully assembled 4406 fountain weighs 62 lbs. Please be considerate of weight when performing installation.
2. This fountain is to be mounted on a smooth, at, nished surface with adequate support structure. NOTE: Mounting
structure must be capable of supporting 300lb load on the fountain, in addition to the weight of the fountain itself.
3. Install shut-off valve on water supply. (Valve not furnished)
4. Locate and install fountain using 3/8" minimum fasteners. (Fasteners not furnished)
5. Connect water supply and fountain drain. Water connection and drain must comply with local codes.
6. Turn on water supply and check all connections for leaks.
CAUTION: This fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used if the
inlet water supply exceeds 105 PSI. Any damage caused by reason of connecting this product to supply line
pressures lower than 20 PSI or higher than 105 PSI is not covered by warranty.
7. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/2" IPS. Contractor to supply waste trap and service stop valve in
accordance with local code.
8. Connecting lines to be made of unplated copper and should be thoroughly ushed to remove all foreign matter before being
connected to fountain. This fountain is manufactured in such a manner that it does not in any way cause taste, odor, color,
or sediment problems.
9. Connect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and the
fountain. Remove any burrs from outside of water line. Push the tubes straight into the ttings until they reach a positive
stop, approximately 3/4" (See Fig. 2). DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE
O-RINGS MAY RESULT.
INSTALLATION INSTRUCTIONS
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN
ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE
WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN
FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE
FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
TROUBLE SHOOTING AND MAINTENANCE
ACTUATION OF QUICK CONNECT WATER FITTINGS:
Fountain is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the tting, relieve
water pressure, push in on the gray collar while pulling on the tubing. (see Fig.2) To insert tubing, push tube straight into
tting until it reaches a positive stop, approximately 3/4".
B CA
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B C
1/4” O.D. TUBE
WATER INLET
TO COOLER
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER
INLET
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
FIG 1 FIG 2
PAGE 3
4406_FTN_A LK4406_FTN_A
1000004375 (Rev. B - 07/18)
FINISHED FLOOR
33 3/8"
847mm
11 7/16"
290mm
11 7/16"
290mm
55°
110°
50°
45°
50°
45°
32 7/8"
834mm
10"
254mm
O
(3 PL)
32 1/8"
816mm
38 3/8"
974mm
39 11/16"
1008mm
ORIFICE
HEIGHT
27 1/8"
689mm
34 11/16"
881mm
ORIFICE
HEIGHT
21 1/4"
540mm
8 1/4"
210mm
16 1/4"
413mm
8"
203mm
10"
254mm
7"
178mm
9"
229mm
O
1/2"
13mm
(4) HOLES
25 5/8"
651mm
REF.
*
"C"
"B"
"A"
28 7/8"
733mm
1 1/4"
32mm
4 1/2"
114mm
3/4"
19mm
6 1/2"
165mm
5/8"
16mm
LEGEND
A = 3/8" O.D. UNPLATED COPPER TUBE CONNECT - SHUT OFF VALVE BY OTHERS
B = REMOVABLE BOTTOM COVER
C = IN-LINE STRAINER
*ADA REQUIREMENT
PAGE 41000004375 (Rev. B - 07/18)
4406_FTN_A LK4406_FTN_A
5
4
8
7 11 (3)
10 (12)
3
2
See Fig. 3
6
9
1
9
9
1
5
4
8
6
6
6
12
13
6
9
PAGE 5
4406_FTN_A LK4406_FTN_A
1000004375 (Rev. B - 07/18)
ITEM
NO.
PART NO.
28467C
56092C
55996C
98530C
97446C
98682C
1000003694
1000003695
1000004374
98684C
0000000325
97247C
1000003813*
1000004366
40251C
ITEMIZED PARTS LIST
1
2
3
4
5
6
7
8
9
10
11
12
13
Basin
Poly Tubing (Cut To Length)
In - Line Strainer
Kit - Regulator/Holder/Nut
Kit - Bubbler (VR)
Kit - Push Button w/Blank Nameplate
Kit - Push Button w/LK4406 Nameplate
Kit - Push Button w/4406 Nameplate
Drain Tube
Kit - Drain Elbow/Gasket/Nut/Washer
Kit - Drain Plug/Gasket
Kit - VR Torx Screws/Bit
Bottom Cover
Drain Tube (Formed)
Drain Tail Pipe (Straight)
DESCRIPTION
PRINTED IN U.S.A.
Halsey Taylor – halseytaylor.com
Elkay – elkay.com
FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL TECHNICAL SERVICES AT 1.800.834.4816
2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
*FINISH COLOR OPTIONS – Choose color option to
complete your model number, add as sufx example:
4406EVG
Matte nish: Evergreen = EVG
Gloss nish:
Beige = BGE Gray = GRY Terracotta = TER
Black = BLK Orange = ORN White = WHT
Blue = BLU Purple = PUR Yellow = YLW
Brown = BRN Red = RED
*select color option to complete part number
FIG. 4
STREAM HEIGHT ADJUSTMENT:
Stream height is factory set at 35 psi. If supply pressure varies greatly
from this, insert a small straight bladed screwdriver through the access
hole in the center of the push button and turn the adjustment screw.
Clockwise adjustment will raise the stream and counterclockwise ad-
justment will lower the stream. For best adjustment, the stream should
be approximately 1 1/2" above the top of the bubbler.
Vandal-Resistant Bubbler
FIG. 3
5
BASIN
  • Page 1 1
  • Page 2 2
  • Page 3 3