CHAUVET DJ 4Bar Reference guide

Category
Stroboscopes & disco lights
Type
Reference guide
Quick Reference Guide
4BAR™ QRG EN
2
About This
Guide
The 4BAR Quick Reference Guide (QRG) has basic
product information
such as mounting, menu options, and DMX values. Download the
User
Manual from www.chauvetlighting.com for more details.
Disclaimer
The information and specifications here are subject to change without notice.
Chauvet reserves to right to revise or reissue this QRG.
Safety Notes
These Safety Notes include important information about product mounting,
use, and maintenance.
This product is not intended for permanent installation.
ONLY connect this product to a grounded and protected circuit.
DISCONNECT from power before cleaning or replacing the fuse.
DO NOT look at the light source when the product is on.
Make sure the power cord is not crimped or damaged.
Never disconnect this product from power cord by pulling on the cord.
When mounting this product overhead, ALWAYS use a safety cable.
DO NOT allow flammable materials close to the product when it is operating.
DO NOT touch the product’s housing when it is on because it will be hot.
DO NOT operate this product if the housing, lenses, or cables appear
damaged.
The voltage of the outlet to which you are connecting this product must be
within the range stated on the decal or rear panel of the product.
This product is for indoor use only! (IP20) To prevent risk of fire or
shock, do not expose this product to rain or moisture.
Always mount this product in a location with adequate ventilation, at least
20 in (50 cm) from adjacent surfaces.
Be sure that no ventilation slots on the unit’s housing are blocked.
Never connect this product to a dimmer or rheostat.
Replace the fuse with the same type and rating.
ONLY carry this product by the hanging/mounting brackets.
The maximum ambient temperature is 104 °F (40 °C). Do not operate this
product at higher temperatures.
In the event of a serious operating problem, stop using immediately.
DO NOT open this product. It contains no user-serviceable parts.
To eliminate unnecessary wear and improve its lifesp
an, during periods of
non-use completely disconnect the product from power via breaker or by
unplugging it.
Contact
Outside the U.S., United Kingdom, Ireland, Mexico, or Benelux, contact your
distributor to request support or return a product. Visit
www.chauvetlighting.com for contact information.
What Is
Included
4BAR™
Power Cord
Carrying Case
Tripod
Footswitch
Warranty Card
Quick Reference Guide
Tripod Carrying Case
To Begin
Unpack your 4BAR™ and make sure you have received all parts in good
condition. If the box or contents appear damaged, notify the carrier
immediately, not Chauvet.
4BAR™ QRG EN
3
Product
Description
low-
blue LEDs per light, the 4BAR™ offers built-in automated and sound-
Product Overview
AC Power
This product has an auto-ranging power supply that can work with an input
voltage range of 100 to 240 VAC, 50/60 Hz.
To eliminate wear and improve its lifespan, during periods of non-
use
completely disconnect from power via breaker or by unplugging it.
Fuse
Replacement
To replace the fuse in the 4BAR:
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the safety cap out of the housing.
4. Remove the blown fuse from the clip on the front of the safety cap and
replace with a fuse of the exact same type and rating.
5. Re-insert the fuse holder and reconnect power.
Mounting
Before mounting this product, read the Safety Notes.
Product
Mounting
Diagram
Back Panel View
Power In
Fuse Holder
LED Display
DMX
In/Out
Microphone
Footswitch
Connection
Sound Sensitivity
Adjustment Knob
Clamp Hanging Bolts
Pan Angle Adjustment Knob
Tilt Angle
Adjustment
Knob
Tripod Insertion Point
4BAR™ QRG EN
4
Control Panel
Description
Button Function
<MENU>
Exits the current menu or function
<UP>
Navigates up through the menu list or increases the numeric
value when in a function
<DOWN>
Navigates down through or decreases the numeric value
Menu Options
Main Level Programming Levels Description
DMX Personalities
3-CH
d 1–d512
Sets DMX personality and starting address
15CH
Sound Active Mode
SND
Sets Sound Active mode
Automatic Mode
AUTO
Sets Auto Program
Auto Program Speed
S--
S 1–S100
Sets Auto Program speed
DMX Linking
The 4BAR™ can work with a DMX controller when linked by DMX serial
connections. Instructions for DMX operation are in the User Manual. A
DMX
Primer is available from www.chauvetlighting.com.
Starting
Address
To ensure full access to all channels in each DMX mode, the highest
recommended DMX address is 498.
Master/Slave
Connection
The 4BAR™ uses the DMX data connection for its Master/Slave mode.
Instructions for connecting and configuring this product for
Master/Slave
operation are in the User Manual.
4BAR™ QRG EN
5
DMX Values
15CH
Channel
Function Value Percent/Setting
1
Control/Operating
Mode
000 ó 009
RGB Color Mixing
010 ó 029
Auto Program 1
030 ó 049
Auto Program 2
050 ó 069
Auto Program 3
070 ó 089
Auto Program 4
090 ó 109
Auto Program 5
110 ó 129
Auto Program 6
130 ó 149
Auto Program 7
150 ó 169
Auto Program 8
170 ó 189
Auto Program 9
190 ó 209
Auto Program 10
210 ó 229
Auto Program 11
230 ó 249
Auto Program 12
250 ó 255
Sound-Active mode
2 Dimmer
000 ó 009
No function
010 ó 255
Dimmer 1100%
3 Strobe
000 ó 009
No function
010 ó 255
Slow to fast
4
Red
000 ó 255
0–100%
RGB Color Mixing
(Pod 1)
5
Green
000 ó 255
0–100%
6
Blue
000 ó 255
0–100%
7
Red
000 ó 255
0–100%
RGB Color Mixing
(Pod 2)
8
Green
000 ó 255
0–100%
9
Blue
000 ó 255
0–100%
10
Red
000 ó 255
0–100%
RGB Color Mixing
(Pod 3)
11
Green
000 ó 255
0–100%
12
Blue
000 ó 255
0–100%
13
Red
000 ó 255
0–100%
RGB Color Mixing
(Pod 4)
14
Green
000 ó 255
0–100%
15
Blue
000 ó 255
0–100%
3-CH
Channel
Function Value Percent/Setting
1
Red
000 ó 255
0–100%
2
Green
000 ó 255
0–100%
3
Blue
000 ó 255
0–100%
4BAR™ QRG Multi-Language
Contact
Us
WORLD HEADQUARTERS - Chauvet
General Information
Address:5200 NW 108th Avenue
Sunrise, FL 33351
Voice: (954) 577-4455
Fax: (954) 929-5560
Toll free:(800) 762-1084
Technical Support
Voice: (954) 577-4455 (Press 4)
Fax: (954) 756-8015
Email: tech@chauvetlighting.com
World Wide Web
www.chauvetlighting.com
UNITED KINGDOM AND IRELAND - Chauvet Europe Ltd.
General Information
Address:Unit 1C
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK
NG16 6NT
Voice: +44 (0)1773 511115
Fax: +44 (0)1773 511110
Technical Support
Email: uktech@chauvetlighting.com
World Wide Web
www.chauvetlighting.co.uk
MEXICO - Chauvet Mexico
General Information
Address:Av. Santa Ana 30
Parque Industrial Lerma
Lerma, Mexico C.P. 52000
Voice: +52 (728) 285-5000
Technical Support
Email: servicio@chauvet.com.mx
World Wide Web www.chauvet.com.mx
CHAUVET EUROPE - Chauvet Europe BVBA
General Information
Address: Stokstraat 18
9770 Kruishoutem
Belgium
Voice: +32 9 388 93 97
Technical Support
Email: Eutech@chauvetlighting.eu
World Wide Web
www.chauvetlighting.eu
Outside the U.S., United Kingdom, Ireland, Mexico, or Benelux, contact the dealer
of record. Follow their instructions to request support or to return a product. Visit
our website for contact details.
4BAR™ QRG Rev. 4 ML9
© Copyright 2015 Chauvet
All rights reserved.
Printed in the P. R. C.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

CHAUVET DJ 4Bar Reference guide

Category
Stroboscopes & disco lights
Type
Reference guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI