  • I've reviewed the operation manual for the Fiber optic terminal box AA17084. This manual provides a step-by-step guide on how to install the device, from opening the box to making final cable connections. It outlines procedures such as stripping and coiling cables, splicing with pigtails, and ensuring strain relief. I am ready to answer your questions about this device.
  • What is the minimum cable length required?
    What should I do with the stripped cable after coiling it?
    What should I do after splicing?
Operation manual
Model: AA17084
Step 1.
Open the Fiber optic terminal box. Check and prepare
installation tools and accessories. To establish easy and safe
installation put the box where it will be installed and measure
the required length of the cable. Prepare the safe installation
of the box.
Step 2.
Strip the cable the required length, minimum 1 meter or
more, to establish easy and safe installation with enough
buffer size. Fix the cable strength member (4) on the column
(3), then use the cable gland (1) and stabilize with cable fixing
part (2) inside the box.
Step 3.
Coil the cable inside the bottom box and enter the stripped
cable into splicing the tray (1). Splice the stripped cable with
the pigtails (2). Put on the fiber protect sleeves, then in the
splice tray (3).
Step 4.
Pass the spliced pigtails to the upper side of the tray and
connect with the adapters, so the remaining cables are coiled
up the puffer.
Step 5.
Connect the pigtails with the drop cable connector after
finishing the basic light test or the measuring of all fibers,
then ensure the strain relief with the fixing rib.
Step 6.
Close the box after finishing all cable connections.
1
4
3
2
1
3
2
1
www.optical.hu
/