Medium-Pressure Stationary Pump
SER 9660
Alemite Corporation 3 Revision (1-97)
Item
No.
Part No. Description Qty Notes
Numeric Order
Part # (Item #)
1 9668 Pump Assembly, Medium-Pressure
1
See SER
9668
9668 (1)
2 326750-B1 Adapter, Bung 1 Model 9660 and 9669-B 172207-1 (9)
3 328034 Connector, 1/4 " NPTF (m) 1 All 17804 (8)
4 328030 Coupler Air, 1/4 " NPTF (f) 1 All 48018 (7)
5
338147-1 Extension, Suction Tube, 21-3/4 " Long 1 Model 9660 and 9660-A 77786 (10)
338147-2 Extension, Suction Tube, 28-1/4 " Long 1 Model 9669-B 326750-B1 (2)
6 338145 Cover Assembly (w/ Gasket) 1
Model 9660-A
328030 (4)
7 48018 Screw, Thumb, 1/4 " -28 3 328034 (3)
8 17804 Washer, 1/4 " 4 338145 (6)
9
172207-1 Washer, Lock, 1/4 " 4 338147-1 (5)
10 77786 Capscrew, 1/4 " -20 x 1/2 "
4
338147-2 (5)
Assembly
NOTE
: Refer to
Figure 2
for component
identification on all assembly procedures.
CAUTION
Select a clean environment for all assembly proce-
dures. Prevent contamination from foreign mate-
rial. Damage to components can occur.
Pump Assembly
IMPORTANT: Make sure to remove the pro-
tective cover from the inlet of Pump Assem-
bly (
1
).
NOTE
: Procedures 1 and 2 are applicable to
model 9660-A only.
1. Install Pump Assembly (
1
) into Cover (
6
).
2. Secure the Pump Assembly to the Cover with
Washers (
8
), Lock Washers (
9
), and Capscrews (
10
).
• Tighten the Capscrews securely.
IMPORTANT: Do not apply thread sealant to
the first two (2) threads of any connection.
Contamination can occur.
3. Screw Extension (
5
) [with thread sealant] into the foot
valve of the Pump Assembly.
• Tighten the Extension securely.
4. Screw Connector (
3
) [with thread sealant] into the inlet
of the air motor.
• Tighten the Connector securely.
5. Attach Air Coupler (
4
) to the Connector.
NOTE
: The remaining procedures are appli-
cable to model 9660-A only.
6. Fit the pump and cover assembly onto the container.
7. Secure the Cover to the container with Thumb
Screws (
7
).
Changes Since Last Printing
New Format