Supermicro SUPERSERVER 5018A-TN7B User manual

Category
Server barebones
Type
User manual
USER’S MANUAL
Revision 1.0a
SUPERSERVER
®
5018A-TN7B
The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and
documentation, is the property of Supermicro and/or its licensors, and is supplied only under a
license. Any use or reproduction of this product is not allowed, except as expressly permitted by
the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class B
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a consumer environment
or residential installation. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause
harmful interference with radio communications. Operation of this equipment in a residential area
is likely to cause harmful interference, in which case you will be required to correct the interference
at your own expense
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate
warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: This product can expose you to chemicals including
lead, known to the State of California to cause cancer and birth
defects or other reproductive harm. For more information, go
to www.P65Warnings.ca.gov.
!
Manual Revision 1.0a
Release Date: September 01, 2020
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2020 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America
3
Preface
Preface
About this Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SuperServer. Installation and
maintenance should be performed by experienced technicians only.
             
supported memory, processors and operating systems (http://www.supermicro.
com).
This manual may be periodically updated without notice. Please check the
Supermicro Web site for possible updates to the manual revision level.
Secure Data Deletion
A secure data deletion tool designed to fully erase all data from storage devices
can be found on our website: https://www.supermicro.com/about/policies/disclaimer.
cfm?url=/wftp/utility/Lot9_Secure_Data_Deletion_Utility/
Warnings
Special attention should be given to the following symbols used in this manual.
Warning! Indicates high voltage may be encountered when performing
a procedure.
Warning! Indicates important information given to prevent equipment/
property damage or personal injury.
4
SUPERSERVER 5018A-TN7B Manual
Contents
Chapter 1 Introduction ..............................................................................1-1
1-1 Overview ......................................................................................................... 1-1
1-2 Motherboard Features ..................................................................................... 1-2
Processors ...................................................................................................... 1-2
Memory ........................................................................................................... 1-2
Serial ATA ........................................................................................................ 1-2
I/O Ports .......................................................................................................... 1-2
LAN Ports ........................................................................................................ 1-2
1-3 Server Chassis Features ............................................................................... 1-3
System Power ................................................................................................. 1-3
Drives .............................................................................................................. 1-3
Control Panel .................................................................................................. 1-3
PCI Expansion ................................................................................................ 1-3
Cooling System ............................................................................................... 1-3
1-4 Contacting Supermicro .................................................................................... 1-5
Chapter 2 Installation in a Rack
2-1 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location ............................................................................. 2-1
2-2 Warnings and Precautions .............................................................................. 2-2
Rack Precautions ............................................................................................ 2-2
Server Precautions .......................................................................................... 2-2
Rack Mounting Considerations ....................................................................... 2-3
Ambient Operating Temperature ................................................................ 2-3
 ......................................................................................... 2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading ..................................................................................... 2-3
Reliable Ground ......................................................................................... 2-3
2-3 Installing the System into a Rack .................................................................. 2-4
Installing the Chassis into a Rack:.................................................................. 2-4
Chapter 3 System Interface
3-1 Overview ........................................................................................................ 3-1
3-2 Control Panel Buttons ..................................................................................... 3-2
3-3 Control Panel LEDs ........................................................................................ 3-2
Overheating ..................................................................................................... 3-3
Overheat Temperature Setting ................................................................... 3-3
Responses .................................................................................................. 3-3
3-4 Power Supply LEDs ........................................................................................ 3-4
5
Preface
Chapter 4 Standardized Warning Statements for AC Systems
About Standardized Warning Statements ....................................................... 4-1
 ........................................................................................... 4-1
Installation Instructions .................................................................................... 4-4
Circuit Breaker ................................................................................................ 4-5
Power Disconnection Warning ........................................................................ 4-6
Equipment Installation ..................................................................................... 4-8
Restricted Area ................................................................................................ 4-9
Battery Handling ............................................................................................ 4-10
Redundant Power Supplies (if applicable to your system) ........................... 4-12
Backplane Voltage (if applicable to your system) ......................................... 4-13
Comply with Local and National Electrical Codes ........................................ 4-14
Product Disposal ........................................................................................... 4-15
Hot Swap Fan Warning (if applicable to your system) ................................. 4-16
Power Cable and AC Adapter ...................................................................... 4-18
Chapter 5 Advanced Motherboard Setup
5-1 Handling the Motherboard .............................................................................. 5-1
Precautions ..................................................................................................... 5-1
Unpacking ....................................................................................................... 5-1
5-2 Connecting Cables .......................................................................................... 5-2
Connecting Data Cables ................................................................................. 5-2
Connecting Power Cables .............................................................................. 5-2
Connecting the Control Panel ......................................................................... 5-2
5-3 I/O Ports .......................................................................................................... 5-3
5-4 Memory Support .............................................................................................. 5-4
Memory Population Guidelines ....................................................................... 5-4
Memory Installation Guidelines ...................................................................... 5-5
Installing DIMM Memory Modules ................................................................... 5-5
5-5 Expansion Cards ............................................................................................. 5-5
5-6 Motherboard Details ........................................................................................ 5-6
A1SRM-LN7F Motherboard Quick Reference ................................................ 5-7
  ..................................................................................... 5-9
Power Connectors ........................................................................................... 5-9
5-8 Jumper Settings ............................................................................................ 5-16
5-9 Onboard Indicators ........................................................................................ 5-18
5-10 SATA Ports .................................................................................................... 5-19
5-11 Installing Software ......................................................................................... 5-20
SuperDoctor
®
5 ............................................................................................. 5-21
5-12 Serverboard Battery ...................................................................................... 5-22
6
SUPERSERVER 5018A-TN7B Manual
5-13 IPMI ............................................................................................................... 5-23
BMC ADMIN User Password ........................................................................ 5-23
Chapter 6 Advanced Chassis Setup and Maintenance .........................6-1
6-1 Static-Sensitive Devices .................................................................................. 6-1
Precautions ..................................................................................................... 6-1
6-2 Removing Power from the System ................................................................. 6-2
6-3 Removing the Chassis Cover ......................................................................... 6-3
6-4 Installing the Hard Drives ................................................................................ 6-4
Installing 3.5" Fixed Hard Drives .................................................................... 6-4
Installing 2.5" Fixed Hard Drives .................................................................... 6-5
6-5 Expansion Card Setup .................................................................................... 6-6
6-6 Installing the Air Shroud .................................................................................. 6-8
 ............................................................................ 6-8
6-7 System Fans ................................................................................................... 6-9
Optional Fan ...................................................................................................6-11
6-8 Power Supply ............................................................................................... 6-12
Replacing the Power Supply ......................................................................... 6-12
Chapter 7 BIOS
7-1 Introduction ...................................................................................................... 7-1
Starting BIOS Setup Utility .............................................................................. 7-1
 ......................................................... 7-1
How to Start the Setup Utility ......................................................................... 7-2
7-2 Main Setup ...................................................................................................... 7-2
 ...................................................................... 7-4
7-4 IPMI ............................................................................................................... 7-26
7-5 Event Logs .................................................................................................... 7-28
7-6 Boot Settings ................................................................................................. 7-30
7-7 Security Settings ........................................................................................... 7-32
7-8 Save & Exit ................................................................................................... 7-35
Appendix A BIOS POST Error Codes .................................................... A-1
Appendix B System Specications ........................................................ B-1
7
Preface
Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: [email protected] (General Information)
[email protected] (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: [email protected] (General Information)
[email protected] (Technical Support)
[email protected] (Customer Support)
Web Site: www.supermicro.nl
Asia-Pacic
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C)
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3992
Web Site: www.supermicro.com.tw
8
SUPERSERVER 5018A-TN7B Manual
Notes
Chapter 1
Introduction
1-1 Overview
The SuperServer 5018A-TN7B is a compact, low-power server comprised of two
main subsystems: the SC510-203B 1U server chassis and the A1SRM-LN7F-2758
single processor motherboard. Refer to the Supermicro web site for operating

In addition to the motherboard and chassis, various hardware components are
listed below:
One riser card (RSC-RR1U-E8) and bracket for PCIe expansion
Cooling: Two 4-cm fans (FAN-0106L4)
Note: For your system to work properly, please follow the links below to download
all necessary drivers/utilities and the user’s manual for your server.
Product manuals: http://www.supermicro.com/support/manuals/
Product drivers and utilities: https://www.supermicro.com/wftp
Product safety information:
http://www.supermicro.com/about/policies/safety_information.cfm
For support, email [email protected].
Chapter 1: Introduction
1-1
1-2
SUPERSERVER 5018A-TN7B User's Manual
1-2 Motherboard Features
At the heart of the SuperServer 5018A-TN7B lies the A1SRM-LN7F-2758, a single
processor motherboard based on the Intel Atom System on a Chip. (see Figure
1-1 for a block diagram).
Processors
The motherboard supports a single Intel Atom C2758, SoC FCBGA 1283, 20W
8-Core processor.
Memory
The motherboard has four DDR3 UDIMM sockets that can support up to 64 GB of

in x8 width only, in sizes 16, 8, 4, or 2 GB.
Serial ATA

I/O Ports
The motherboard includes seven gigabit Ethernet LAN ports, including a shared
IPMI port, seven USB 2.0 connectors (four rear ports, three headers), one SATA
DOM power connector, two serial connectors (one rear port, one header), and one
VGA port.
LAN Ports
The system features seven GbE LAN ports, including six LAN bypass (SW
programmable) ports with SoC I354, I350-AM2 and I210-AT.
Chapter 1: Introduction
1-3
1-3 Server Chassis Features
The SuperServer 5018A-TN7B is built on the SC510-203B, a small form factor 1U
rackmount server chassis. The following is a general outline of the main features.
System Power
The system has a single 200 watt low-noise AC-DC power supply with PFC (part
number PWS-203-1H).
Drives
The chassis is designed to support one 3.5" internal hard drive or up to four 2.5"
internal hard drives. The internal drives are not hot-swappable.
Control Panel
The control panel provides system monitoring and power control. LEDs indicate
power on, network activity, hard disk drive activity and system overheat. The control
panel also includes a main power button and a reset button.
PCIe Expansion

with one 3.5" drive or two 2.5" drives each with a single drive bracket, it accepts a

no room for an expansion card.
Cooling System
The chassis has an innovative cooling design that features two 4-cm counter-

a BIOS setting. The system supports up to three fans.
1-4
SUPERSERVER 5018A-TN7B User's Manual
Figure 1-1. ISystem Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
PEG [0..3]
LPC
TPM HDR
SOC
VGA
FAN x 3
PEG [4]
AST2400
PCIE 2.0 x 1
COM2
LAN5
REAR
USB 0
USB [2:3]
TX/RX
(debug)
0 Ohm
NI
LPC
UART1
UART2
SGMII x 4
MARVELL PHY
88E1543
LAN1
LAN2
LAN3
LAN4
+
SATA5 3.0
SATA1 2.0
SATA GEN2
SATA4 3.0
SATA
GEN3
SATA2 2.0
SATA3 2.0
mSATA
PEG [12..15]
REAR/J29
USB Hub
+
DDR3 UDIMM
B1B2
FLASH 64Mb
SPI
PCIE 2.0 x 8 OPEN SLOT
PCIE 2.0 x 4
PCIE 2.0 x 4
USB 1
Intel I350
REAR/U128
LAN7
LAN6
PEG [8]
Intel I210
PCIE 2.0 x 1
USB 2.0 x1
COM1
USB
USB
USB
USB
TYPE A
+
HEADER
x2
SATA0 2.0
BMC share LAN
NCSI I
MARVELL PHY 88E1543 INTEL i350
CONTROL CIRCUIT
CONTROL CIRCUIT
CONTROL CIRCUIT
SMBUS
CPLD EPM570
RJ45
LAN6
RJ45
LAN7
RJ45
LAN3
RJ45
LAN4
RJ45
LAN1
RJ45
LAN2
SATA0 is MUXed with mSATA
USB 2.0 x5
USB 2.0 x2
DDR3 UDIMM
DDR3 UDIMM
DDR3 UDIMM
REAR/U131 REAR/U136
A1
A2
CHA
CHB
REAR/J28
Note:
(1) The block diagram is for A1SRM-LN7F-2758 full SKU
(2) A1SRM-LN7F-2358:
One DIMM channel(CHA) is supported, up to 1333/8G per DIMM;
Two SATA2 ports(port0/1) are supported;
Others keep the same with A1SRM-LN7F-2758.
(3) A1SRM-LN5F-2358:
One DIMM channel(CHA) is supported, up to 1333/8G per DIMM;
Two SATA2 ports(port0/1) are supported;
I350, LAN6 and LAN7 are unpopulated;
Others keep the same with A1SRM-LN7F-2758.
Chapter 1: Introduction
1-5
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: [email protected] (General Information)
[email protected] (Technical Support)
Website: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: [email protected] (General Information)
[email protected] (Technical Support)
[email protected] (Customer Support)
Website: www.supermicro.nl
Asia-Pacic
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C)
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3992
Website: www.supermicro.com.tw
1-6
SUPERSERVER 5018A-TN7B User's Manual
Notes
Chapter 2
Installation in a Rack
This chapter provides instructions for mounting your chassis in a rack.
2-1 Preparing for Setup
The box in which your system was shipped should include the mounting screws
to mount the system into the rack. Please read this chapter in its entirety before
beginning the installation procedure.
Choosing a Setup Location
Decide on a suitable location for the rack unit that will hold your system. It should
be a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical

is required
Leave at least 25 inches clearance in front of the rack to open the front door
completely.
Leave approximately 30 inches of clearance in the back of the rack to allow for

It should be a restricted access location, such as a dedicated equipment room
or a service closet.
2-1
SUPERSERVER 5018A-TN7B User's Manual
2-2
2-2 Warnings and Precautions
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to

In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more
simultaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the
rails.

work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
Allow the power supply modules to cool before touching them.
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-3
Chapter 2 Installation in a Rack
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating
temperature of the rack environment may be greater than the ambient temperature
of the room. Therefore, consideration should be given to installing the equipment
in an environment compatible with the manufacturer’s maximum rated ambient
temperature (Tmra).
Reduced Airow
  
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power

on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack
itself should be grounded. Particular attention should be given to power supply
connections other than the direct connections to the branch circuit (i.e. the use of
power strips, etc.).
To prevent bodily injury when mounting or servicing this unit in a rack, you
must take special precautions to ensure that the system remains stable.
The following guidelines are provided to ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit
in the rack.
             
bottom to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
Slide rail mounted equipment is not to be used as a shelf or a work space.
SUPERSERVER 5018A-TN7B User's Manual
2-4
2-3 Installing the System into a Rack
The system can be installed into a rack directly using screws.
Installing the Chassis into a Rack:
1. 
chassis into a rack.
2. Align the thru-holes of the chassis with the thru-holes of the rack.
3. Insert the mounting screws into the thru-holes in the front of the chassis and
through the thru-holes in the rack
Figure 2-1. Installing the Chassis into a Rack
Note: Figures are for illustrative purposes only. Always install servers into racks
from the bottom up.
Stability hazard. The rack stabilizing mechanism must be in place, or the

Failure to stabilize the rack can cause the rack to tip over.
3-1
Chapter 3 System Interface
Chapter 3
System Interface
3-1 Overview
The chassis includes a control panel on the front with power buttons and status
monitoring lights. The power supply has status lights.
Figure 3-1. Control Panel
SUPERSERVER 5018A-TN7B User's Manual
3-2
3-3 Control Panel LEDs

Power: The main power switch is used to apply or remove power from the power

power but maintains standby power. To perform many maintenance tasks, you must
unplug system before servicing.
Reset: The reset button is used to reboot the system.
NIC2
Information LED: Alerts operator of several states, as noted in the table below.
Information LED
Status Description
Continuously on and red
An overheat condition has occured.
(This may be caused by cable congestion.)
Blinking red (1Hz) Fan failure, check for an inoperative fan.
Solid blue
UID has been activated locally to locate the server in a rack
environment.
Blinking blue
UID has been activated using IPMI to locate the server in a
rack environment.
3-2 Control Panel Buttons
The chassis includes two push-buttons that control power to the system.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122

Supermicro SUPERSERVER 5018A-TN7B User manual

Category
Server barebones
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI