Haier YR-E16b User manual

Category
Split-system air conditioners
Type
User manual

Haier YR-E16b is a versatile air conditioner that offers a wide range of features for your comfort. With its powerful cooling and heating capabilities, it can maintain your desired temperature efficiently. The auto swing function ensures even distribution of air throughout the room, while the sleep mode adjusts the temperature gradually for a restful night's sleep. Additionally, the unit features various health functions, such as air purification and a filter clean reminder, to keep your indoor air fresh and clean.

Haier YR-E16b is a versatile air conditioner that offers a wide range of features for your comfort. With its powerful cooling and heating capabilities, it can maintain your desired temperature efficiently. The auto swing function ensures even distribution of air throughout the room, while the sleep mode adjusts the temperature gradually for a restful night's sleep. Additionally, the unit features various health functions, such as air purification and a filter clean reminder, to keep your indoor air fresh and clean.

WIRED CONTROLLER
Page 1
ENGLISH
YR-E16b Wired Controller
User Manual
TABLE OF CONTENTS
Ductless Split Air Conditioner
Wired Control Panel Functions .................. 2
Features and Interface ....................................2
Installation ................................................ 4
Operation ................................................. 5
Settings & Functions .......................................5
• ThissystemshouldbeinstalledbyaqualiedHVAC
professional.Incorrectinstallationmaycausere,water
damage, personalinjuryordeath.
• Whenabnormalitiessuchasaburntsmellaredetected,
immediatelypowerothemainswitchandcontacta
licensed contractor.
• Do not obstruct or cover ventilation grill on the air con-
ditioner.Donotputngers/objectsintoinlet,outletor
swinglouver
• Donotallowchildrentoplayonorneartheoutdoor
system equipment
WARNING
!
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Page 2 WIRED CONTROLLER
ENGLISH
WIRED CONTROL PANEL FUNCTIONS
Wired Controller YR-E16b
Features and Interface
1
Left
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Modekeyinthemaininterface,return
key in other interface.
2
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Autokey,Pressittoenableautomode
immediately.
3
4
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Left/Rightkey,fanspeedadjustment
key,swingangleadjustmentkeyinthe
maininterface,directionadjustment
key in other interface.
5
6
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Up/Downkey,temp.adjustmentkey
inthemaininterface,shiftdirection
andvalueadjustmentkeyinother
interface.
7
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Menukeyinthemaininterface,enter
key in other interface.
8
Right
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Swingkeyinthemaininterface,back
to the main interface through the key
inotherinterface.When theswing
functionisinvalid,pressthekeyto
adjustfanspeed.
9
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
On/Okey
Quiet function.
Turbo function.
Childlockfunction.PreetheLeftand
Right keys at the same time in the
main interface for 5s to either set or
cancel the function.
Forced defrost function. (Function is
not available for mini-split and multi-
split.)
Ventilationfunction.(Functionisnot
available for mini-split and multi-split.)
Healthfunction.(Functionisnot
available for mini-split and multi-split.)
Quick start function. (Function is not
available for mini-split and multi-split.)
Nightquietfunction,thisfunction
operationsonlyatnightwhenset.
(Function is not available for mini-split
and multi-split.)
Electrical heating. (Function is not
available for mini-split and multi-split.)
Autoswing.
Autoswingup.
Autoswingdown.
Sleep function.
Errorcodefunction,thisiconwill
displayinthemaininterfacewhen
thewiredcontrollerortheindoorunit
linked to the controller has an error.
Weekly programming.
1
2
3
5
7
4
6
8
9
WIRED CONTROLLER
Page 3
ENGLISH
Date,week,clockdisplayarea,
the format the of date can
be changed through the time
function.
Set Temperature range
60°F-86°F
Indoor room temperature.
Indoor humidity display area
(reserved for future models).
Mode
Auto Cooling Heating Fan Dry
The mode cycle depends on mode
setting in basic setting function.
Up/DownswingandLeft/Right
swingfunction.
Fanspeed,thecycletypeoffanspeed
can be set through basic setting.
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
The quantity of indoor units connected
tothewiredcontroller.
Defrost
Defrost function.
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Thestateoftheindoorunit,thisareacan
also display “operation
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Thestateofwiredcontroller,this
area also can display”slave”. “Master”
meansthewiredcontrolleristhemain
controller,“Slave”meansthewired
controller only can control parts of
functions.
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
PM2.5 A++
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Reserved function.
Filter clean reminder. Default = 500
running hours.
EnergySavingfunction.Thisiconwillbe
displayedonlywhenenergysavingfunc-
tion is set.
Motion sensor on.
MotionSensingairowfollowing
human.
MotionSensingairowavoidhuman.
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Outdoor temperature display
area.Itcanbesetwhether
display or not.
Thursday
Set temp.
Mode Menu Swing
Indoor temp.
Qty. online
Standby
Defrost Master
Outdoor temp. 36 °F
Outdoor humidity 32%RH
70 °F
32%RH
Indoor humidity
76
°F
10:30
AM
01.01.2015
Outdoor humidity display area.
Itcanbesetwhetherdisplayor
not. (Not valid for mini-split and
multi-split units.)
Page 4 WIRED CONTROLLER
ENGLISH
Wired Controller Wiring Instructions
INSTALLATION
Wired Controller Wiring
1. Holdthefrontofthecontroller,pushdownthebackcoverto
open the back cover of the controller.
2. Putcommunicationwirethroughtheholeinthebackcover.
3. Fix the back cover.
4. ConnectcommunicationwiretoCON4portofwired
controller.
5. Finallyputthefrontcoverofwiredcontrollertobackcover
to complete the installation.
Communication Wiring
Communication Wiring
Length
Dimension of Wiring
0~100 ft (0~30m) 22AWG(0.3mm
2
)x3-core
shieldedwire
100~200 ft (30~60m) 20AWG(0.5mm
2
)x3-core
shieldedwire
200~300 ft (0~90m) 18AWG(0.75mm
2
)x3-core
shieldedwire
300-400 ft (90~120m) 16AWG(1.25mm
2
)x3-core
shieldedwire
400~500 ft (120~150m) 14AWG(2mm
2
)x3-core
shieldedwire
Note: the battery is non-removable and recharges while the unit
is connected to power in order to save user settings if there is a
power outage.
3 3/4 (95.74)
1 3/8 (34)
5/8 (15.26)
3 11/16 (94)
4 3/4 (120)
1 7/8 (47.4)
13/16 (21.44)
4 3/4 (120)
7/16 (11.8)
11/16 (17.8)
7/16 (11.87)
9/16 (14.03)
WIRED CONTROLLER
Page 5
ENGLISH
OPERATION
Settings & Functions
Schedule options include segmented timing and random
timing. It can be selected through display setting. The default
is segmented timing.
Segmented timing (recommended setting)
Thursday
Return Enter Main
10:30
Display Setting
Language
English
°C
Spanish
°F
French
Russian
Italian
Segmented timing
Chinese
Random timing
Schedule
Temp. unit
AM
01.01.2015
1. Note: The segmented timing will only operate in cooling or
heating mode. will not execute in fan mode. Time can be
adjustedin24hours,thedefaultformatoftimedisplayis
12-hour.Temperaturecanbeadjustedfrom60°Fto86°F,
OFF”canalsobesetmeaningpowero.
2. First,theleftandrightarrowsashbesidethetimeof
wake-up.Nextpresstheenterkey,thearrowswillbestatic,
continuetopressleftorrightkeytoadjusttimefollowedby
theenterkeytoconrm.Thefourdirectionkeyscanmove
thearrowwhentheyareashing.
3. Pressokkeytoconrmthesettingaccordingtheprompt
belowthescreen.
4. Thedefaultvalueisthesameinthegurebelow.
Pressthemenukeyinthemaininterfacetoenterthe
operation settings menu.
Weekly Program
1. KeeppressingLeft/Rightkeytospeeduptimeadjustment.
Random timing
Thursday
Return Enter Main
10:30
Display Setting
Language
English
°C
Spanish
°F
French
Russian
Italian
Segmented timing
Chinese
Random timing
Schedule
Temp. unit
AM
01.01.2015
1. When
+
ashesinthescheduleeditinginterface,press
the enter key to enter the setting interface.
Thursday
Schedule
Sleep
Time
Swing
Extra function
Humidity control
Error code
Display setting
Service help
Installer setting
Mode Menu Swing
10:30Menu
AM
01.01.2015
Thursday
Schedule
Sleep
Time
Swing
Extra function
Humidity control
Error code
Display setting
Service help
Installer setting
Return Enter Main
10:30Menu
AM
01.01.2015
Thursday
Cancel Ok
10:30
Schedule
AM
01.01.2015
Heat
(mon.-fri.)
Cool
(mon.-fri.)
Heat
(sat.-sun.)
Cool
(sat.-sun.)
Wake
6:00 am
70°F
OFF
70°F
OFF
Leave
8:00 am
70°F 85°F 62°F 62°F
Return
6:00 pm
70°F 85°F
OFF
78°F
Sleep
10:00 pm
62°F 82°F 62°F 62°F
Thursday
Cancel Ok
10:30Schedule
AM
01.01.2015
1
Weekday
+
Add
-
Delete
2
Everyday
3
Monday
3
Tuesday
No. Week Mode Temp
26.0°F 12:47 N
22.0°F 14:22 Y
19.0°F 15:34 N
20.0°F 09:25 Y
Time Enable
Press
for page turning
Thursday
Cancel Ok
10:30Schedule Setting
AM
01.01.2015
Mode On/OffTemp
20.5
°F
14:20 NON
Time Week
Enable/
Disable
Auto
Cool
Week
day
Mon.
Wed.
Fri.
Sun.
Tue.
Thu.
Sat.
Every
day
Heat
Fan
Dry
1. Intelligentmode,76°F,powero,12:00,enableand
weekdayisdefault.
2. Iftheschedulethatyouaresettinghasbeensetbefore,the
interfacewillpromptyou thattheschedulealreadyexists.
You need to cancel it or change the repeated parameters.
The Timer ON of this Unit is in conict
with the existing Timer OFF, please
reset the Timer ON.
Cancel Enter
The Timing of this Unit has been set.
Do you want to replace the previous
setting?
Cancel Enter
The Timer OFF of this Unit is in conict
with the existing Timer ON, please
reset the Timer OFF.
Cancel Enter
The Timing has been set, please revise
relevant parameters.
Cancel Enter
1. Aftersetting,pressOktoconrmthetimingandgobackto
schedule interface simultaneously.
Presstheenterkeytodeleteaschedulewhen“
-
”ashes.
Thedeleteinterfacewilldisplay.Nowchoosethenumberyou
wanttodeletethroughthedirectionkeysandenterkey.
Cancel Enter
Please select the No. you want to delete.
all 1 2 4 6 83 5 7
9
10 11 13 15 1712 14 16
18 19 20 22 24 2621 23 25
27 28 29 31 33 3530 32 34
Page 6 WIRED CONTROLLER
ENGLISH
Whenthetimeiconisashing,presstheenterkeytoenter
the time interface.
Presstheenterkeytoenterthesettinginterfacewhenthe
iconisashinginthemenu.
1. The default information for each function is decided by
indoorunitexceptchildlock.Childlockfunctionisoby
default.
2. MovethearrowsusingtheUp/DownorLeft/Rightkey.
Arrowswilldisplaystaticallywhenyoupressenterkey.Press
theLeft/Rightkeytochoose“ON”or“OFF”.Aftersetting,
pressUp/Downkeytoconrmandmovetotheaboveor
belowfunctiondirectlyorpresstheenterkeytosetagain.
3. Thecorrespondingfunction iconwilldisplayinthemain
interfacewhenafunctionissetinextrafunction.
4. Some functions are not available for some models. These
willbegreyedout.TurboandQuietfunctionconictand
can’tbothbeon.Settingonewilldisabletheother.Thisis
thesameforhealthairowupanddown.
5. Important: When child lock is set to ON, the interface skips
to the main display automatically. The function also can be
set or canceled by pressing the Left and Right keys together
for 5s in the main interface.
Presstheenterkeytoentertheerrorcodedisplayinterface
whentheiconisashinginthemenu.
1. Up/Downkeytochoosetheunit.Left/Rightkeytochange
pages.
2. Onecurrenterrorcodewilldisplayanduptothirtyvepast
errorcodeswilldisplayforeachunit.
3. PresstheLeftandRightkeystogetherfor5sto clearaway
theerrorhistoryinformationofthecurrentunit.Press
UpandDownkeystogetherfor5stoclearawaytheerror
history information of all the units on line. The combination
method is only valid in error interface.
Time
Extra Function
Error Code
1. The defaultdateisDecember 12th,2014,thetimeis
12:00PMandtheweekisFriday.Adjustingsettingsisthe
samewayasscheduleadjusting.
2. The defaultformatis12-hourandMonth/Day/Year.
Thursday
Return Enter Main
10:30
Time
01.01.2015
AM
Time setting
2015
year
AM
9
hour
11
month
35
minute
30
day
Mon.
week
12-hour 24-hour
Year/Month/Day
Day/Month/year
Month/Day/Year
Date format
setting
Thursday
Return Enter Main
10:30
Extra Function
01.01.2015
AM
Quiet Ventilation
Turbo Health
Child lock Quick start
Forced
defrost
Night quiet
NO NO
OFF OFF
ON ON
OFF OFF
Thursday
Return Enter Main
10:30
Error Code
01.01.2015
AM
Current error
Error history
Error code:017 20/08/2014 11:20
Error code:017 18/08/2014 15:35
Error code:006 27/10/2013 13:56
Error code:012 20/05/2014 09:37
Error code:013 10/08/2014 23:14
Presstheenterkeytotheservicehelpinterfacewhentheicon
isashinginthemenu.
1. Passwordfunctionincludespasswordsettingandrecovery.
Thedefaultpasswordis841226. Whennishedentering
password,pressdirectionkeytocancelorenter,thenpress
enterkeytoconrm,orcontinuetopressenterkeyto
conrmafterinputtingsixnumbers.
Service Help
Thursday
Return Enter Main
10:30
Service & Help
01.01.2015
AM
Password
Help
Passwordrecovery
Passwordsetting
Howtosetchildlock?
Howtocleanlters?
Howtoinquireerrorcodes?
Howtosetfour-waycassetteangle?
1. Ifpassword recoveryisset, theinterfacewillpromptas
follows,thencancelorenter.
1. Helpfunctionisavailableforonlysomemodels.The
informationisgraywhenitisnotavailable.
Do you really want to password
recovery?
Cancel Enter
WIRED CONTROLLER
Page 7
ENGLISH
Thursday
Return Enter Main
10:30
Swing
01.01.2015
AM
Type
Up/Down
ON
Left/Right
OFF
Four-way
cassette
Angle
control
NotavailableinNorthAmerica.
Pressenterkeytoentertheinterfacewhenswingiconis
ashinginthemenu.Passwordisrequired.(Passwordis
841226).
1. Thedefaultinformationofswingtypeandanglecontrol
is decided by the indoor unit and is automatically decided
whenconnected.Whentypeandanglecontrol aresetin
adierentcombination,themaininterfacewilldisplay
correspondingiconandthenswingfunctionwillbeupdated
by indoor unit.
Sleep
Swing
2.Ifacombinationisnotavailable,theinformationwillbegray.
3.Ifnoswingisset,the swingkeyinthemaininterfaceisused
foradjustingthefanspeed.
4.IfUp/DownandLeft/Rightswingwithnoangleisset,swing
keyinthemaininterfacecontrolsopenandcloseofswing.
5.IfUp/DownandLeft/Rightswingwithangleisset,the
swingiconwillashafterpressingtheswingkeyinthemain
interface.NextpressLeft/Rightkeytoadjustangle.Swing
keyisusedforshiftingUp/DownswingandLeft/Right
swing.Thereisnooperationfor5safterswingiconashes,
theiconwill bestatic indicatingquittingadjustment.
6.Iftheindoorunit isafour-waycassettemodel,swing
functioninthemenuisinvalid. Swingkeyinthemain
interfaceisusedforchangingthedeector.Theorder
fourdeectors->deector1->deector2->deector3-
>deector4->fourdeectors.Thedeectorashesfor
5swhenitisselected,then pressLeft/Rightkeytoadjust
swingangleofthisdeectoratthesametime.
7.Angledenition:
Up/Downswing:1standsforangle1,2standsforangle2,3
standsforangle3,4standsforangle4,5standsforangle5,
1and2standforhealthairowup,4and5standsforhealth
airowdown,thecirculationof1->2->3->4->5->4->3->2-
>1standsforautomaticswing.
Up/Downswingwillbechangedinsequenceasfollows:
angle1->angle2->angle3->angle4->angle5->automatic
swing->angle1.
1
2
3
4
5
1
2
3
4
5
Left/Rightswing:
Left/rightswingcanbeadjustedaspertheuser’s
requirement.Thecirculationof1->2->3->4->5->4->3->2-
>1standsforautomaticswing.
Not available for mini-split and multi-split.
Humidity Control
8.Thedefaultangleindierentmodesisasfollows:
Up/Downswing:
Auto Heating Cooling Dry Fan
Angle Angle1 Angle5 Angle1 Angle1 Angle1
Left/Rightswing:
Auto Heating Cooling Dry Fan
Angle Angle1 Angle1 Angle1 Angle1 Angle1
Four-waycassette:
Auto Heating Cooling Dry Fan
Deector
Four
deectors
Four
deectors
Four
deectors
Four
deectors
Four
deectors
Angle Angle1 Angle5 Angle1 Angle1 Angle1
Page 8 WIRED CONTROLLER
ENGLISH
Indoor temperature display
Ifthefunctionisturnedon,themaininterfacewilldisplaythe
indoortemperature.Ino,themaininterfacewillnotdisplay
indoor temperature.
Indoor humidity display
It is only available for some models.
Outdoor temperature display
It is only available for some models.
Outdoor humidity display
It is only available for some models.
Presstheenterkeytoenterthefunctionwhentheiconis
ashinginthemenu.
Details
Thecorrespondingparameterinformationwillbedisplayedin
thisfunction.Up/Downkeytoadjustunitnumber,Left/Right
key to turn page. Some information is gray that can not be
inquired.
Installer Setting
Presstheenterkeytogotothenextinterfacewhentheiconis
ashinginthemenu.
1. Screen saving
There arevescreensavingtimeoptions.Thetime
indicateshowlongthescreenlightstaysonafterno
operation.”Cancel”meansthatthe screenlightwillnevergo
o.
2. Brightness
The function is used for controlling the light intensity.
Language
Only valid for some models.
Temp. unit
Celsius or Fahrenheit can be selected through this function.
Schedule
Segmented timing or Random timing can be set. Segment
timing is highly recommended.
Display Setting
Thursday
Return Enter Main
10:30
Display Setting
Screen
saving
15s
30%
30s
50%
1min
60%
3mins
80%
Cancel
100%
Bright
-ness
AM
01.01.2015
Thursday
Return Enter Main
10:30
Display Setting
Language
English
°C
Spanish
°F
French
Russian
Italian
Segmented timing
Chinese
Random timing
Schedule
Temp. unit
AM
01.01.2015
Thursday
Return Enter Main
10:30
Display Setting
Outdoor temp display
Indoor humidity display
Indoor temp display
Outdoor humidity display
PM2.5 display
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
AM
01.01.2015
Thursday
Return Enter Main
10:30
Details
01.01.2015
AM
Mode Cool
Auto
07
A++
Speed
Indoor address
PM2.5
unit
6
Address setting
Thedefaultpasswordis841226. Thecommunicationaddress
canbesettwoways.Onewayisthewiredcontroller.The
otherwayisthewiredcontrollerwithautomaticcompeting
set.Centraladdressandcommunicationaddressbetween
indoorandoutdoorcanbothbe adjustedaccordingtothe
individual situation.
Thursday
Return Enter Main
10:30
Address Setting
01.01.2015
AM
Comm. Add.
setting
Central address
4
68
Communication address
between
indoor and outdoor unit:
unit
6
wired controller + auto
wired controller
Thursday
Return Enter Main
10:30
Details
01.01.2015
AM
Central address:
113
37
unit
6
Communication address between indoor
and outdoor unit:
37
WIRED CONTROLLER
Page 9
ENGLISH
Basic setting
The information of model is controlled by the indoor unit and
can not be changedas is the same to capacity information.
Normal fan
The default information is controlled by the indoor unit.
Mode selection
Dierentmodecombinationscanbesetaccordingtoeach
application.
New/old protocol
Self-adaption is default. The function is used for basic
settings.Donotresetit,orthecontrollermaynotwork
normally.
Power o memory
Ifthefunctionisseton,thewiredcontrollerwillmaintainthe
previousstateintemperature,fanspeed,etcfrominoutage
topowerupagain.
Master/Slave set
Wired controller can be set as master controller or slave
controller through this function. Slave controller can only
control some of the functions.
Ambient temperature revision
Therevisionvalueisonlyvalidforwiredcontrollerambient
temperature.Pressenterkeytomakethearrowsstaticand
adjustthetemperatureusingtheLeft/Rightkey.
Thursday
Return Enter Main
10:30
Basic Setting
AM
01.01.2015
Mode
selection
Auto Heat Dry Cool Fan
Heat Dry Cool Fan
Cool Heat Fan
Auto Bypass Recovery
Heat only
Hot water
Dry Cool Fan
Thursday
Return Enter Main
10:30
Basic Setting
AM
01.01.2015
Power off
memory
Outdoor fan
xed speed
Master/Slave
set
grade
ON
OFF
Slave
rotational speed
Master
Thursday
Return Enter Main
10:30
Basic Setting
AM
01.01.2015
Ambient temp.
revision
Twin energy
judgement
condition
ON
OFF
4 group
2 group
3 group
1 group
- 3.5 º F
Indoor temperature collection
Theambienttemperaturemaybereadfromthewired
controller or the indoor unit through this setting. The same for
indoor humidity reading.
Inbasicsettinginterface,pressUp/Downkeytoadjust
unitnumber;pressLeft/Rightkeytomovethecursor.
Some functions are not available for some models and the
information is gray.
ECO
NOTE:Theenergysavingdefaultparametersarelistedbelow:
74°FLowesttemperaturelimitofCoolingandDrymode.
78°FHighesttemperaturelimitofHeatingmode.
74°F–86°FTemperatureadjustmentrangeinCoolingandDry
mode.
Fourdirectionkeyscanmovethecursor,whenthearrows
ash,pressenterkeytostoptheashingandpressLeft/
Rightkeytoadjustthevalue,thenpresstheenterkeyagain
toconrm.AftersettingECOfunction,thetemp.adjustment
willbelimited.Ifoverrunisset,thetemp.canbeadjustoutof
ECOrangeinallowabletime.
Thursday
Return Enter Main
10:30
Basic Setting
AM
01.01.2015
unit
6
Available
Wired controller
Wired controller
Unavailable
Indoor unit
Indoor unit
Indoor hum.
collection
Indoor temp.
collection
Wi module
Thursday
Return Enter Main
10:30
ECO
AM
01.01.2015
ON
Setting
Range of temp.
The highest limit
of heating
The lowest limit
of cooling/dry
OFF
Temp.
ECO
75.0ºF
75.5ºF
Thursday
Return Enter Main
10:30
ECO
AM
01.01.2015
ON
No overrun
Type
permitted
OFF
Temp.
ECO
2
hour
15
min
Thursday
Return Enter Main
10:30
Basic Setting
AM
01.01.2015
Breeze
Quiet fan
Auto fan
Auto fan
High speed fan
Super fan
ON
ON
ON
ON
ON
1
OFF
OFF
OFF
OFF
2 3
Normal
fan
unit
6
OFF
Page 10 WIRED CONTROLLER
ENGLISH
Running time
The function records both continuous running time and total
running time. When the bottom color of “Clear” changes to
white,pressenterkeytocleartheaccumulativerunningtime.
Vip priority choice
The function is only available for some models.
Special setting
Whenthethermostatisconnectedtoducttypeindoorunit,
thethermostatwilldetecttheavailablespeeds(static)the
unit is capable of.
Forexample,iftheunitonlyhave4staticsetting,thenitwill
onlyshow1-4.Thestaticpressurerangecanbereferencedin
the service manual of the corresponding indoors.
Thursday
Return Enter Main
10:30
Running Time
AM
01.01.2015
Continuous Running
Time
0014:22:53
0037:10:26
Total Running
Time
Clear
Clear
Thursday
Return Enter Main
10:30
Motion sensing
Motion sensing follow
Power off
when sensing
nobody in
Motion sensing evade
30 mins
15 mins
ON
ON
10 mins
OFF
OFF
OFF
AM
01.01.2015
Parameter setting
The function is only available for some models.
EEPROM setting
The function is only available for some models.
Motion sensing
The function is available for some models. When motion
sensingfolloworevadeisset,theangleofthedeectorwill
bedecidedbytheperson’scurrentlocation,thesettingswing
angle in the main interface is invalid at this time. When the
functionofautomaticpoweroisset,indoorunitwillpower
oaftersensingnobodyintheroomforthesettingtime.All
the functions in the interface are “OFF” by default.
www.Haier.com
HaierAmerica,
Wayne,NJ07470
©2016HaierAmericaTrading,LLC.
Model #: YR-E16b
IssuedDate:January2016
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Haier YR-E16b User manual

Category
Split-system air conditioners
Type
User manual

Haier YR-E16b is a versatile air conditioner that offers a wide range of features for your comfort. With its powerful cooling and heating capabilities, it can maintain your desired temperature efficiently. The auto swing function ensures even distribution of air throughout the room, while the sleep mode adjusts the temperature gradually for a restful night's sleep. Additionally, the unit features various health functions, such as air purification and a filter clean reminder, to keep your indoor air fresh and clean.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI