Supermicro 1026T-6RFT+ User manual

Category
Server barebones
Type
User manual

This manual is also suitable for

SUPERSERVER 1026T-6RFT+
SUPERSERVER 1026T-6RF+
SUPER
®
USER’S MANUAL
1.0
The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and docu-
mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environ-
ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the manufacturer’s instruction manual, may cause harmful interference
with radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warn-
ing applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to the
State of California to cause birth defects and other repro-
ductive harm.
Manual Revision 1.0
Release Date: January 12, 2011
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2011 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America
iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians.
It provides information for the installation and use of the SuperServer 1026T-
6RFT+/1026T-6F+. Installation and maintenance should be performed by experi-
enced technicians only.
Manual Organization
Chapter 1: Introduction
The rst chapter provides a checklist of the main components included with the
server system and describes the main features of the X8DTU-6TF+/X8DTU-6F+
serverboard and the SC119TQ-R700UB chassis, which comprise the SuperServer
1026T-6RFT+/1026T-6F+.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer into a rack and
check out the server con guration prior to powering up the system. If your server
was ordered without processor and memory components, this chapter will refer you
to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 1026T-6RFT+/1026T-6F+.
SUPERSERVER 1026T-6RFT+/1026T-6F+ User's Manual
iv
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X8DTU-6TF+/X8DTU-6F+
serverboard, including the locations and functions of connections, headers and
jumpers. Refer to this chapter when adding or removing processors or main memory
and when recon guring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC119TQ-R700UB server chassis.
You should follow the procedures given in this chapter when installing, removing or
recon guring SAS or peripheral drives and when replacing system power supply
modules and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: System Speci cations
v
Preface
Notes
vi
SUPERSERVER 1026T-6RFT+/1026T-6F+ User's Manual
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Serverboard Features .....................................................................................1-2
Processors ......................................................................................................1-2
Memory ...........................................................................................................1-2
Onboard SAS ..................................................................................................1-2
Onboard Serial ATA ........................................................................................ 1-2
Rear I/O Ports .................................................................................................1-2
Graphics Controller .........................................................................................1-3
Other Features ................................................................................................1-3
1-3 Server Chassis Features ................................................................................1-3
System Power .................................................................................................1-3
Hard Drives .....................................................................................................1-3
PCI Expansion Slots .......................................................................................1-3
Front Control Panel .........................................................................................1-4
Cooling System ...............................................................................................1-4
1-4 Contacting Supermicro ....................................................................................1-6
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup .........................................................................................2-1
Choosing a Setup Location .............................................................................2-1
Rack Precautions ............................................................................................2-2
Server Precautions ..........................................................................................2-2
Rack Mounting Considerations .......................................................................2-3
Ambient Operating Temperature ................................................................2-3
Reduced Air ow .........................................................................................2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading .....................................................................................2-3
Reliable Ground ......................................................................................... 2-3
2-4 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rack Rails ......................................................2-4
Inner Rails .......................................................................................................2-5
Outer Rails ...................................................................................................... 2-6
2-5 Checking the Serverboard Setup .................................................................... 2-8
Installing the Server into a Telco Rack ...........................................................2-8
vii
Table of Contents
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
3-2 Control Panel Buttons ..................................................................................... 3-1
UID ..................................................................................................................3-1
Reset ...............................................................................................................3-1
Power ..............................................................................................................3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
UID/Overheat/Fan Fail/Power Fail .................................................................. 3-2
NIC2 ................................................................................................................3-2
NIC1 ................................................................................................................3-2
HDD .................................................................................................................3-3
Power ..............................................................................................................3-3
3-4 Drive Carrier LEDs .......................................................................................... 3-3
Chapter 4 System Safety
4-1 Electrical Safety Precautions .......................................................................... 4-1
4-2 General Safety Precautions ............................................................................ 4-2
4-3 ESD Precautions .............................................................................................4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................... 5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-1
5-2 Processor and Heatsink Installation................................................................5-2
Installing LGA1366 Processors ....................................................................... 5-2
Installing the Heatsink ..................................................................................... 5-4
Removing the Heatsink ................................................................................... 5-5
5-3 Connecting Cables ..........................................................................................5-6
Connecting Data Cables ................................................................................. 5-6
Connecting Power Cables ..............................................................................5-6
Connecting the Control Panel ......................................................................... 5-6
5-4 I/O Ports ..........................................................................................................5-7
5-5 Installing Memory ............................................................................................ 5-8
5-6 Adding PCI Cards .........................................................................................5-12
5-7 Serverboard Details ...................................................................................... 5-13
X8DTU-6TF+/X8DTU-6F+ Quick Reference .................................................5-14
5-8 Connector De nitions .................................................................................... 5-15
5-9 Jumper Settings ............................................................................................5-23
5-10 Onboard Indicators ........................................................................................5-25
viii
SUPERSERVER 1026T-6RFT+/1026T-6F+ User's Manual
5-11 SATA Port Connections ................................................................................. 5-27
5-12 Installing Software .........................................................................................5-28
Supero Doctor III ........................................................................................... 5-29
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices ..................................................................................6-1
Precautions .....................................................................................................6-1
6-2 Control Panel ..................................................................................................6-2
6-3 System Fans ...................................................................................................6-2
System Fan Failure ......................................................................................... 6-3
Air Shroud ....................................................................................................... 6-4
Hard Drive Installation .....................................................................................6-6
Hard Drive Backplane ..................................................................................... 6-8
DVD-ROM Drive Installation ........................................................................... 6-8
6-4 Power Supply .................................................................................................. 6-9
Power Supply Failure ......................................................................................6-9
Chapter 7 BIOS
7-1 Introduction ......................................................................................................7-1
Starting BIOS Setup Utility ..............................................................................7-1
How To Change the Con guration Data .........................................................7-1
Starting the Setup Utility .................................................................................7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Setup Con gurations......................................................................7-4
7-4 Security Settings ...........................................................................................7-25
7-5 Boot Con guration ........................................................................................ 7-27
7-6 Exit Options ...................................................................................................7-28
Appendix A BIOS Error Beep Codes
Appendix B System Speci cations
Chapter 1
Introduction
1-1 Overview
The SuperServer 1026T-6RFT+/1026T-6F+ is a high-end server comprised of two
main subsystems: the SC119TQ-R700UB 1U server chassis and the X8DTU-6TF+/
X8DTU-6F+ dual processor serverboard. Please refer to our web site for informa-
tion on operating systems that have been certi ed for use with the system (www.
supermicro.com).
In addition to the serverboard and chassis, various hardware components have
been included with the 1026T-6RFT+/1026T-6F+, as listed below:
One slim DVD-ROM drive (DVM-TEAC-DVD-SBT)
Five sets of 4-cm counter-rotating fans (FAN-0101L4)
One air shroud (MCP-310-81901-0B)
Two passive CPU heatsinks (SNK-P0037P)
Riser Cards: (see Section 5-6 for details)
One RSC-R1UU-2E8
One RSC-R1UU-E8R+
SAS Accessories
One SAS backplane (BPN-SAS-815TQ)
One SAS cable (CBL-0044L)
Eight drive carriers (MCP-220-00047-0B)
One rackmount kit (MCP-290-00062-0N)
One CD containing drivers and utilities
SuperServer 1026T-6RFT+/1026T-6F+ User's Manual
Chapter 1: Introduction
1-1
1-2
SUPERSERVER 1026T-6RFT+/1026T-6F+ User's Manual
1-2 Serverboard Features
At the heart of the SuperServer 1026T-6RFT+/1026T-6F+ lies the X8DTU-6TF+/
X8DTU-6F+, a dual processor serverboard based on the Intel® 5520 chipset. Below
are the main features of the serverboard. (See Figure 1-1 for a block diagram of
the chipset).
Processors
The X8DTU-6TF+/X8DTU-6F+ supports single or dual Intel® 5500/5600 Series
processors in LGA1366 sockets. Please refer to our web site for a complete listing
of supported processors (www.supermicro.com).
Memory
The X8DTU-6TF+/X8DTU-6F+ features 18 DIMM sockets that can support up to 192
GB of registered ECC DDR3-1333/1066/800 or 48 GB of unbuffered ECC/non-ECC
DDR3-1333/1066/800 SDRAM. Please refer to Chapter 5 for installing memory.
Onboard SAS
An onboard LSI 2108 SAS controller in integrated into the X8DTU-6TF+/X8DTU-
6F+. The hot-swap SAS drives are connected to a backplane that provides power,
bus termination and con guration settings.
Note: The operating system you use must have RAID support to enable the
hot-swap capability and RAID function of the SAS drives. RAID 0, 1, 5, 6,
10, 50 and 60 is supported. Refer to the following ftp site for setup guidelines
<ftp://ftp.supermicro.com/driver/SAS/LSI/LSI_SAS_EmbMRAID_SWUG.pdf>.
Onboard Serial ATA
An on-chip (ICH10R) SATA controller is integrated into the X8DTU-6TF+/X8DTU-
6F+ to provide a six-port, 3 Gb/sec SATA subsystem, which is RAID 0, 1, 5 and
10 supported (RAID 5 is supported with Windows OS only). The SATA drives are
hot-swappable units.
Note: You must have RAID set up to enable the hot-swap capability of the SATA
drives. Documentation on RAID setup guidelines can be found on our web site.
Rear I/O Ports
The color-coded I/O ports include one COM port, a VGA (monitor) port, two USB
2.0 ports, PS/2 mouse and keyboard ports, one dedicated IPMI LAN port and two
1-3
Chapter 1: Introduction
gigabit Ethernet ports. The 1026T-6RFT+ (X8DTU-6TF+) includes two additional
10 Gb Ethernet ports.
Graphics Controller
The X8DTU-6TF+/X8DTU-6F+ features an integrated Matrox G200eW graphics
chip.
Other Features
Other onboard features that promote system health include onboard voltage moni-
tors, auto-switching voltage regulators, chassis and CPU overheat sensors, virus
protection and BIOS rescue.
1-3 Server Chassis Features
The 1026T-6RFT+/1026T-6F+ is built upon the SC119TQ-R700UB chassis. Details
on the chassis and on servicing procedures can be found in Chapter 6.The following
is a general outline of the main features of the chassis.
System Power
The SC119TQ-R700UB features a redundant 700W power supply consisting of
two power modules. The system does not need to be shut down when replacing or
removing a single power supply module.
Hard Drives
The SC119TQ-R700UB chassis was designed to support eight hot-swap SAS
hard drives.
PCI Expansion Slots
Two riser cards are included. The RSC-R1UU-E8R+ is located on the right side of
the chassis and supports one low-pro le PCI-E x4 card. The RSC-R1UU-2E8 is
located on the left side of the chassis and supports two PCI-E x8 add-on cards.
See section 5-6 of this manual for details.
1-4
SUPERSERVER 1026T-6RFT+/1026T-6F+ User's Manual
Front Control Panel
The chassis' control panel provides you with system monitoring and control. LEDs
indicate system power, HDD activity, network activity (2), overheat/fan/power failure
and UID (Unit Identi er). A main power button and a UID button is also included.
Cooling System
The SC119TQ-R700UBP has an innovative cooling design that features ve sets
of 4-cm counter-rotating fans located in the middle section of the chassis. There
is a "Fan Speed Control Mode" setting in BIOS that allows chassis fan speed to
be determined by system temperature. The power supply module also includes a
cooling fan.
1-5
Chapter 1: Introduction
Figure 1-1. Intel 5520 + IOH-36D/ICH10R Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
Processor#1
QPI
DDR3 DIMM
C
A
B
D
E
F
DDR3 DIMM
DDR3 DIMM
DDR3 DIMM
DDR3 DIMM
DDR3 DIMM
B
C
E
F
3,4
BMC
VGA SWITCH
ESI
SPI
ATMEL
AT25DF321
CLINK
CLINK
PCIE Port 1-4
PCI-E x8
Gen2 x16
Gen2 x8
ICH10R
ESI
IOH
36D
PORT0
PORT
PORT
7,8,9,10
5,6
PCI-E x16
PORT
PCI-Ex8
in x4 slot
RJ45
COMA
COMB
SIO
PS2 KB/MS
USB 0/1
USB
QPI
QPI
Gen2 x8
PORT
8,10
(Lane Reversal)
SATA #2
SATA #3
SATA #4
SATA #5
SATA #0
SATA
PCI
USB
TPM
LPC
PORT1 PORT1
Gen2 x4
PORT
1,2
in x16 slot
VGA VGA
KAWELA
RJ45 RJ45
Gen1x2
KAWELA
RJ45 RJ45
Gen1 x4
PCIE Port 5-6
Processor#0
SATA #1
USB 2/3
USB 4/5
USB 6
USB 7
PORT0
1-6
SUPERSERVER 1026T-6RFT+/1026T-6F+ User's Manual
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: [email protected] (General Information)
[email protected] (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: [email protected] (General Information)
[email protected] (Technical Support)
[email protected] (Customer Support)
Asia-Paci c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd.
Chung-Ho 235, Taipei County
Taiwan, R.O.C.
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Tel: 886-2-8228-1366, ext.132 or 139
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your 1026T-6RFT+/1026T-6F+
up and running. Following these steps in the order given should enable you to have
the system operational within a minimum amount of time. This quick setup assumes
that your system has come to you with the processors and memory pre-installed. If
your system is not already fully integrated with a serverboard, processors, system
memory etc., please turn to the chapter or section noted in each step for details on
installing speci c components.
2-2 Unpacking the System
You should inspect the box the 1026T-6RFT+/1026T-6F+ was shipped in and note
if it was damaged in any way. If the server itself shows damage you should le a
damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the server. It should be
situated in a clean, dust-free area that is well ventilated. Avoid areas where heat,
electrical noise and electromagnetic elds are generated. You will also need it placed
near a grounded power outlet. Be sure to read the Rack and Server Precautions
in the next section.
2-3 Preparing for Setup
The box the server was shipped in should include two sets of rail assemblies, two
rail mounting brackets and the mounting screws you will need to install the system
into the rack. Follow the steps in the order given to complete the installation process
in a minimum amount of time. Please read this section in its entirety before you
begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suf cient air ow and ease in servicing.This product is for
2-2
SUPERSERVER 1026T-6RFT+/1026T-6F+ User's Manual
!
!
Warnings and Precautions!
installation only in a Restricted Access Location (dedicated equipment rooms,
service closets and the like).
This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display
Units.
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to
the oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the
rails.
Install the heaviest server components on the bottom of the rack rst, and then
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
Allow the hot plug SAS drives and power supply modules to cool before touch-
ing them.
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Air ow
Equipment should be mounted into a rack so that the amount of air ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-4
SUPERSERVER 1026T-6RFT+/1026T-6F+ User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the server into a rack unit with the
rack rails provided. If the system has already been mounted into a rack, you can
skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market,
which may mean the assembly procedure will differ slightly. You should also refer to
the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner xed chassis rail that secures directly
to the server chassis and an outer xed rack rail that secures directly to the rack
itself (see Figure 2-1).
Note: The rails will t a rack between 26" and 33.5" deep.
Figure 2-1. Identifying the Inner Rails and Inner Rail Extensions
Inner Rails
(Inner rails are pre-installed
on the chassis)
Inner Rail
Extensions
Chapter 2: Server Installation
2-5
Inner Rails
The SC119 chassis inner rails are composed of two sections: inner rails and inner
rail extensions. The inner rails are pre-attached and do not interfere with normal use
of the chassis if you decide not to use a server rack. Attach the inner rail extension
to stabilize the chassis within the rack.
Installing the Inner Rails
Place the inner rail extensions on the side of the chassis aligning the hooks 1.
of the chassis with the rail extension holes. Make sure the extension faces
"outward" just like the pre-attached inner rail.
Slide the extension toward the front of the chassis.2.
Secure the chassis with 2 screws as illustrated.3.
Repeat steps 1-3 for the other inner rail extension.4.
1
1
1
2
1
3
Figure 2-2: Identifying the Sections of the Rack Rails
(right side rail shown)
2-6
SUPERSERVER 1026T-6RFT+/1026T-6F+ User's Manual
Outer Rails
Installing the Outer Rails to the Rack
Attach the shorter outer rail to the outside of the longer outer rail. You must 1.
align the pins with the slides. Both bracket ends must face the same direction.
Adjust the outer rails so that they t snugly within the rack.2.
Secure the longer outer rail to the front of the rackl with two screws3.
Secire the shorter outer rail to the rear rack with three screws. 4.
Repeat steps 1-4 for the remaining outer rail.5.
Locking Tabs
Both chassis rails have a locking tab, which serves two functions. The rst is to
lock the server into place when installed and pushed fully into the rack, which is
its normal position. Secondly, these tabs also lock the server in place when fully
extended from the rack. This prevents the server from coming completely out of
the rack when you pull it out for servicing.
Secure to the
Front of the
Rack
Secure to the
Rear of the Rack
Figure 2-3. Assembling the Outer Rails
Attach Outer Rails
Together
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108

Supermicro 1026T-6RFT+ User manual

Category
Server barebones
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI