- 6 -
Auto backup to the ABC-02 when configurations change
The ABC-02 is capable of backing up switch configuration files
automatically. This function is found under “System/System Files/
Configuration Backup and Restore”. While the ABC-02 is plugged into the
switch, enable the “Auto backup to ABC-02 when configuration change”
option. Then click “Apply”. Once this configuration is modified, the switch
will back up the current configuration under the “/His_ini” folder in the
ABC-02. The file name will be the system date/time (MMDDHHmm.ini).
Auto backup of the earliest 100 log entries to prevent overwriting
This function is designed to maintain a long-term record the switch log
files. Moxa Ethernet switches are capable of saving 1000 entries of event
logs. When the 1000-entry storage limit is reached, the switch will delete
the oldest saved event log. The ABC-02 can help to backup these event
logs. When switch log entries reach 1000, the ABC-02 will back up the
earliest 100 entries of the switch.
The function is found under “System/System Files/ Log File Backup”.
Enable the “Auto backup the earliest 100 log entries to prevent
overwriting”. Then click “Apply”. After that, when the ABC-02 is plugged
into the switch, the event logs will always be saved to the ABC-02
automatically.
For further details on the ABC-02 operation through the switch
web console, please refer to the switch user manual.
-02 when the
STATE LED is blinking or
when the web console is showing WORKING status.
The status of the ABC-02 may be checked on the switch web
console or by observing the switch front panel LEDs.
The switch detects
ABC-02-USB plugged in
STATE blinking slowly (1 time/ 2
seconds),
Import/Export in
FAULT, MASTER, COUPLER LEDs
Blink sequentially and circularly
FAULT, MASTER, COUPLER LEDs light
off
FAULT LED light on until ABC-02 is
removed or system reboot
ABC-02 STATE LED green light on
ABC-02 STATE LED blinking
Does not include “Auto backup to the ABC-02 when
and ”Auto backup the earliest 100 log
entries to prevent overwriting