De Luxe KLi, De Luxe KLi eco Refrigerator
Built-in EURO 60
J902.051-5
17.2.12 WIMA
7
These installation instructions apply to the models:
A Information on the necessary mains voltage, type of current and fuse protection can be taken from the identification plate.
Validity
Type Model no. Model
KLi 902 De Luxe (integratable door)
KLi eco 908 De Luxe eco (integratable door)
This appliance is considered to be suitable for use in countries having a warm damp equable climate (WDaE). It may also be
used in other countries. If used in warm damp equable climated countries, the appliance is to be supplied through a residual
current device (RCD) having a rated residual operating current not exceeding 30 mA.
Electrical connections
Built-in (integratable door)
* Allow a gap – at the top and bottom – less than the width of the appliance to ensure proper ventilation (sheets 5–13 in the technical
guide on kitchen planning and design from the Swiss Kitchen Association (KVS)).
Shadow gaps alone – even if extended over several elements – are not sufficient.
100
=
=
120
1524 =12/6
+2
0
min. 50
min. 200 cm² min. 200 cm²
min. 4
a
a
1524 =12/6
+2
0
16–20
Identification plate located
left next to salad crisper
1850 (SMS norm) flush-mounted power socket, type 13
Positioned ABOVE
standard
Positioned BELOW
also possible
Width of element 600
Appliance 1522
Appliance 545 Door panel
Ventilation cross-section *
Door panel
Niche
Niche
Installation instructions
De Luxe KLi, De Luxe KLi eco Refrigerator
Built-in EURO 60
J902.051-5
17.2.12 WIMA
8
A Push the appliance into the niche. Secure to the cabinet with 1 screw (included in the scope of delivery) through each hinge. Then,
screw the appliance to the cabinet at the top with 2 chipboard screws (included in the scope of delivery) each through the fixing bar.
A Installation according to the operating instructions supplied with the appliance.
Installation
The door opening can be changed from right to left up until the point when the appliance is installed in the niche.
1524+2a
max. 594
200
430
~602
100˚
A
16–20
Filler strip H7.1755
(request when ordering appliance)
Detail A
Niche
560–568
Niche
550
Appliance 548
Ventilation
For door panel thickness
greater than 20 mm,
see H7.0314
Door panel
/