CONTENTS
FOR YOUR SAFETY 20
INSTRUCTIONS FOR USE 21
CLEANING AND MAINTENANCE 23
General cleaning 23
Periodical maintenance 24
TECHNICAL CHARACTERISTICS 24
Burner specifications 25
INSTALLER INSTRUCTIONS 25
Gas connection 26
Electrical connection 27
Conversion to other types of gas 28
FITTING IN MODULAR CABINETS 29
Fitting possibilities 32
ASSISTANCE AND REPLACEMENTS 33
WARRANTY TERMS 34
Contents
Thank you for choosing one of our high-quality products.
To ensure optimal and regular performance of your appliance please read this instruction manual
carefully. It will enable you to navigate all processes perfectly and most efficiently. To refer to this
manual any time you need to, we recommend you to keep it in a safe place. And please pass it to any
future owner of the appliance.
We wish you much joy with your new appliance.
20
FOR YOUR SAFETY
This new appliance is easy to use. Nevertheless, make sure to read this handbook carefully
before installing and using it for the first time. In this way you can obtain best results, avoid
incorrect operations, use the appliance in complete safety and respect the environment.
This instruction handbook must be kept with the appliance for any future consultation. If the
appliance is sold or given to another person, make sure the handbook goes with it, so that
the new user has the relevant instructions for use.
Installation
Appliance installation and connection to the power supply must only be carried out by
QUALIFIED PERSONNEL. Before carrying out any operation, make sure the appliance is
DISCONNECTED from the power supply.
Make sure the air can circulate freely around the appliance. Poor ventilation creates a
lack of oxygen.
Make sure the appliance is fed with the type of gas specified on the special sticker
located near the gas connection pipe.
This appliance is not connected to a fume extraction device. It must be installed and
connected in compliance with the current applicable regulations. Particular attention
must be paid to the applicable provisions regarding ventilation.
The use of a gas cooking appliance produces heat and humidity in the room where it is
installed. Ensure good ventilation in the room by keeping air inlets open and efficient,
or install an extractor hood with exhaust flue.
In case of intensive and prolonged appliance use, room ventilation must be made more
efficient by opening a window or increasing the speed of the electric exhaust fan, if present.
After unpacking the appliance, make sure it is not damaged and that the power cable is
in perfect condition. Otherwise, contact the dealer before using the appliance.
If you install the hob under a hood, please see the installation instructions of the hood
for the minimum distance between the appliances.
The Manufacturer declines any liability if the accident-prevention regulations are not
respected.
Safety
This appliance must only be used by adults. Make sure children do not play with the
appliance or touch the controls.
This appliance must not be used by persons (including children) with reduced physical,
sensory or mental abilities, or without experience or knowledge of it, unless supervised
or instructed in its correct use by a person responsible.
The exposed parts of this appliance become hot during cooking and remain hot for
some time even after it is turned off. Keep children away until it has cooled.
During use
This product is designed for non-professional domestic use, for cooking food. Do not use
it for any other purpose.
Any attempt to modify the characteristics of this product is hazardous.
Keep the appliance clean. Food residuals can create the risk of fire.
For your safety
21
Do not use steam or steam devices to clean the appliance.
After using the appliance, make sure all the controls are in the “CLOSED” or “OFF”
position.
When using a power socket near this appliance, make sure the cords of any electrical
appliances being used do not touch it and are far enough away from its hot parts.
Technical assistance
In case of a fault, never attempt to repair the appliance on your own. Repairs carried
out by unqualified persons can cause damage and accidents. Firstly, consult this
handbook. If you do not find the required information, contact the nearest After-Sales
Service Centre. Assistance for this appliance must be carried out by an authorised
After-Sales Service Centre. Always demand the use of original replacement parts.
Advice for safeguarding the environment
All the materials used are environmentally friendly and recyclable. Please make your
contribution to safeguarding the environment by using the appropriate differentiated
waste collection channels.
Before scrapping the appliance, cut off the power cord and make it unusable.
The symbol on the product or on the packing indicates that the appliance should
not be treated as normal household waste but must be taken to an appropriate
collection point for the recycling of electrical and electronic equipment.
Correct disposal of this appliance will help prevent possible negative consequences for
the environment and the health of people. For more detailed information about the
recycling of this product, contact your local council office or waste disposal service, or
the shop where you purchased it.
INSTRUCTIONS FOR USE
Before using the appliance, remove all the packing materials, including the advertising labels
and any protective film.
Hob control knobs
The knobs for the gas rings are located on the side of the hob. The symbols on the control
zone have the following meaning:
no gas
max. gas
min. gas
lighting incorporated in the cock
Instructions for use
22
Lighting the rings
To obtain the flame more easily, light the ring before placing a pot/pan on the grate.
Press the knob corresponding to the ring and turn it anticlockwise to the “max.” symbol.
The lighting symbol ( ) is also located in this position. The flame will light automatically.
Do not operate the igniter for more than 15 seconds. If the burner is not lit after 15 seconds,
stop operating the igniter and wait at least 1 minute before trying to light it again.
After lighting the flame, keep the knob pressed for about 5 seconds. This time is necessary
for heating the “thermocouple” and deactivating the safety valve, which would otherwise
stop the delivery of gas.
Then make sure the flame is even and turn the knob to the required setting.
If the flame does not light after several attempts, make sure the “burner cap” and “flame
spreader” are in the correct position.
1
2
3
4
1 Burner cap
2 Flame spreader
3 Igniter
4 Thermocouple
Instructions for use
To turn off the flame, turn the knob clockwise to the symbol .
1
2
4
3
1 Burner cap flame spreader assembly
2 Burner cap flame spreader assembly
3 Igniter
4 Thermocouple
Manual lighting (in case of a power failure): bring a flame to the ring, press the knob and
turn it anticlockwise to the “max.” symbol.
Always lower the flame or turn it off before removing pots/pans from the rings.
If the burner accidentally goes out, close the control knob and wait at least 1 minute before
relighting it.
23
For correct hob use
To ensure lower gas consumption and better efficiency, only use flat bottom pots/pans of
size suitable for the rings, as indicated in the table at the bottom of the page. Also, as soon
as a liquid starts to boil, lower the flame enough to keep it on the boil.
Carefully watch over your food during cooking with fats or oils, because these substances
can catch fire when very hot.
Do not use aluminium foil to protect the hob during use.
Make sure pots/pans do not protrude over the edges of the hob and that they are placed
centrally on the rings in order to obtain lower gas consumption.
Always lower the flame or turn it off before removing pots/pans from the rings.
Do not place unstable or deformed pots/pans on the rings: they could tip over or spill their
contents, causing accidents.
Pots must not occupy any part of the control zone.
Cleaning and maintenance
Burner min. diameter max. diameter
Triple crown 180 mm 260 mm
Large (rapid) 160 mm 260 mm
Medium (semirapid ) 120 mm 220 mm
Small (auxiliary) 80 mm 160 mm
CLEANING AND MAINTENANCE
Before carrying out any operation, disconnect the appliance from the power supply and
allow it to cool.
General cleaning
Clean the hob regularly with a soft cloth soaked in lukewarm water and a little liquid
detergent. Do not use the following products:
- household detergents or bleaches;
- soapy scouring pads unsuitable for non-stick pots/pans;
- steel wool;
- bath or sink stain removers.
If the hob is very dirty, use specific products available on the market.
Do not leave acid or alkaline substances (e.g. vinegar, salt, lemon juice, etc.) on the hob.
If you notice any breakage or cracks on the glass top, immediately disconnect the appliance
to avoid risk of electric shocks, contact an After-Sales Service Centre and do not use the
appliance until it is repaired.
24
Hob grates
The hobs have cast iron grates.
The grates can be removed from the hob to enable better cleaning.
Keep the cast iron grates in their seats, to avoid scratching or damaging the hob.
The grates cannot be placed in a dishwasher; after washing by hand, make sure to correctly
refit them.
Electric igniter
Automatic lighting of the rings is ensured by a ceramic igniter containing a metal electrode.
Carefully clean these parts of the hob periodically. Also, to avoid difficult lighting make sure
the flame spreader holes are not clogged.
Periodical maintenance
Have the condition and efficiency of the gas pipe and the pressure regulator (if present)
periodically checked.
In case of any anomalies, have the faulty part replaced (and not repaired).
Technical characteristics
TECHNICAL CHARACTERISTICS
Gas burner power
Triple crown burner 4.0 kW
Rapid burner 2.9 kW
Semirapid burner 1.9 kW
Auxiliary burner 1.0 kW
Category II2H3+
Appliance setting natural gas
G20 (2H)
20 mbar
Gas inlet connection G 1/2"
Power supply voltage 220-240 V
~ 50-60 Hz
Appliance class 3
Hob dimensions
Width 1175 mm
Depth 350 mm
Dimensions of opening for fitting
Width 1145 mm
Depth 320 mm
Bypass diameters
Burner Ø Cock
bypass
in hundredths
Auxiliary 33
Semirapid 33
Rapid 45
Triple crown 65
25
Burner specifications
Installer instructions
NOMINAL REDUCED NOMINAL
TYPE OF HEATING HEATING HEATING CAPACITY
BURNER CAPACITY CAPACITY
NATURAL GAS LIQUEFIED GAS
(Natural gas) (Butane/Propane)
kW kW 20 mbar 28-30/37 mbar
Marking Marking g/h
nozzles m
3
/h nozzles G30 G31
100/mm 100/mm
Auxiliary
burner 1.0 0.52 70 0.095 50 73 71
Semirapid
burner 1.9 0.60 96 0.181 71 138 136
Rapid Natural Gas:
burner 2.9 1.10 119 0.276 86 204 200
LPG: 2.8
Triple crown
burner 4.0 1.80 146 0.381 98 291 286
INSTALLER INSTRUCTIONS
ATTENTION: This appliance can only be installed and used in permanently ventilated places
in conformity with UNI 7129 and UNI 7131.
The manufacturer declines any liability for damage due to installation not complying with
the current standards or failure to respect the accident-prevention regulations.
Appliance installation and connection to the power supply must only be carried out by
QUALIFIED PERSONNEL. Before carrying out any operation, make sure the appliance is
DISCONNECTED from the power supply.
Installation room
For correct operation of the gas appliance, the air necessary for gas combustion must be
able to flow naturally in the room.
(The installer must comply with the current UNI-CIG 7129 - 7131 standards).
The air must flow into the room through openings made in the external walls.
These openings must have a free open section of at least 100 cm
2
if the appliance is equipped
with a safety device or 200 cm
2
if the appliance does not have a safety device.
This opening must be located near the floor, preferably on the opposite side to fume
extraction, and be made in such a way that it is not obstructed from the inside or outside.
If the opening cannot be made in the room where the appliance is installed, the necessary
air can come from an adjacent room, provided:
it is not a bedroom or a hazardous environment;
it is not in low pressure;
the ventilation between the room where the appliance is installed and the adjacent
room is ensured by means of permanent openings (UNI-CIG 7129).
26
Fume exhaust
Gas cooking appliances must exhaust the fumes through hoods directly connected to flues
or directly to the outside.
If a hood cannot be installed, it is necessary to use an electric exhaust fan fitted on the
external wall or the window of the room, provided conditions exist so that the opening for
ventilation can be increased in proportion to the fan capacity (UNI-CIG 7129).
The electric exhaust fan must be able to guarantee an hourly air change for a kitchen,
equal to 3-5 times its volume.
Gas connection
The gas connection must be carried out in compliance with UNI-CIG 7129 - 7131 standards.
The appliances leave the factory tested and adjusted for the type of gas specified on the
label located in the bottom protection, near the gas connection pipe. Make sure the type of
gas used is the same as that specified on the label.
Otherwise, proceed according to the instructions given in the section “Conversion to other
types of gas”.
To ensure maximum efficiency and minimum consumption, make sure the gas supply
pressure respects the values given in the “Burner specifications” table.
If the pressure of the gas used is different (or variable) with respect to that provided for, a
suitable pressure regulator for the gas (NOT LPG) complying with Standard UNI EN 88 must
be installed on the inlet piping.
The use of pressure regulators for liquefied gases (LPG) is allowed provided they comply
with Standard UNI EN 12864.
The union is fitted on the end part of the train, with a G 1/2" threaded nut, interposing the
seal between the components as shown in the figure. Screw the parts without forcing, turn
the union in the required direction, then tighten everything.
Connection
Installer instructions
1 Train end with nut
2 Seal
3 Adjustable union
4 Copper pipe
5 Flexible steel tube
1
2
3
2
5
4
Make the connection to the gas system using a rigid metal pipe and fittings complying
with Standard UNI-CIG 7129, or with a s/steel flexible tube complying with Standard UNI-
CIG 9891, limited to those not longer than 2 m. When using flexible metal tubes, make sure
they are not in contact with movable parts or squashed. Pay the same attention also when
an oven and hob combination is provided for.
The gas inlet union for the appliances is 1/2" cylindrical male thread.
Make the connection, avoiding any kind of stress on the appliance.
Important
After installation, always check the perfect tightness of all unions using a soapy solution.
Never carry out this check with a flame.
27
Electrical connection
The appliance is arranged to operate on a 230V single-phase power supply. Connection
must be made in compliance with current standards and regulations.
Before carrying out the connection, make sure:
the limiter valve and the electrical system can take the appliance load (see serial no.
plate);
the supply system is equipped with an efficient earth connection in compliance with
the current standards;
the socket or omnipolar switch used are easily accessible with the appliance installed.
Fit the cable with a plug suitable for the load and connect it to an adequate safety socket.
To connect directly to the mains, a suitable omnipolar switch with contact gap of at least 3
mm and complying with current standards must be installed between the appliance and
the power mains.
The yellow/green earth wire must not be interrupted by the switch.
The brown phase wire (coming from terminal “L” on the terminal block) must always be
connected to the power supply phase.
In any case the power cable must be positioned in such a way that no part of it reaches a
temperature above 90 °C.
An example of an optimum path is shown in the figure. The cable is guided by means of
clamps fixed to the side of the cabinet, in order to avoid any contact with the equipment
beneath the hob.
The installation or replacement of any electrical component must be carried out by an
After-Sales Service Centre technician or qualified personnel.
Replacing the power cable
When replacing the power cable only use H05V2V2-F T90 type cables suitable for the load
and operating temperature. The yellow/green earth wire must be approx. 2 cm longer than
the phase and neutral wires.
1 Neutral
2 Earth (Yellow/Green)
1
2
After connection, test the heating elements by making them work for about 3 minutes.
To open the terminal block cover and access the connection terminals, proceed as follows:
undo the cover fixing screw;
insert the tip of a screwdriver in the protrusions located on the inner side of the
terminal block;
press lightly and prise upwards.
Installer instructions
28
1 Min. flame adjustment bypass pin
1
1
The power cable must only be replaced by the After-Sales Service or by similarly qualifiedThe power cable must only be replaced by the After-Sales Service or by similarly qualified
The power cable must only be replaced by the After-Sales Service or by similarly qualifiedThe power cable must only be replaced by the After-Sales Service or by similarly qualified
The power cable must only be replaced by the After-Sales Service or by similarly qualified
personnelpersonnel
personnelpersonnel
personnel.
Conversion to other types of gas
Replacing nozzles
1. Remove the grates.
2. Remove the burner caps and flame spreaders from the rings.
3. Using a socket wrench, unscrew and remove the nozzles, replacing them with those
corresponding to the type of gas used (see “Burner specifications” table on page 25).
4. Refit the parts by carrying out the above operations in reverse order.
5. Then replace the label (located near the gas connection) with the one for the new
type of gas. The latter is included in the bag of injectors supplied.
If the pressure of the gas used is different (or variable) with respect to that provided for, a
suitable pressure regulator for ducted gas (NOT LPG) complying with Standard UNI EN 88
must be installed on the inlet piping.
The use of pressure regulators for liquefied gases (LPG) is allowed provided they comply
with Standard UNI EN 12864.
Minimum flame adjustment
To adjust the minimum flame, proceed as follows.
1. Light the ring as previously described.
2. Turn the cock to the min. flame position.
3. Extract the knobs.
4. Operate on the bypass pin.
When converting from natural gas to LPG, screw down the bypass pin clockwise.
Installer instructions
When converting from LPG to natural gas, unscrew the bypass pin approx. 1/4 turn.
In any case, the result must be a small and even flame on all the burner crown.
5. Lastly, check that the burner does not go out when quickly turning the cock from
max. to min.
The above adjustment operations can be easily performed, whatever the position or fixing
of the hob on the kitchen unit.
29
1
2
3
4
350
1175
FITTING IN MODULAR CABINETS (MODEL 12550 G-M)
1 Rapid burner
2 Semirapid burner
3 Triple crown burner
4 Auxiliary burner
These hobs are arranged for fitting in modular kitchen units having a depth of between 550
and 600 mm and appropriate characteristics.
The hob dimensions are given in the “Technical Characteristics” section.
Fitting and fixing to the cabinet
The hob can be fitted in a cabinet having an opening
of the size illustrated. The opening must be at least
55 mm from the rear wall.
Any right or left side wall higher than the hob must
be at least 100 mm from the recess in the top.
Before fitting the hob in the recess, apply the special
adhesive seal at the hole, at the distance indicated
in the figure. This seal must be fixed evenly without
breaks or overlapping, to prevent liquid from
entering under the hob.
Fitting in modular cabinets (model 12550 G-M)
550 MIN.
650 MIN.
593
60
550 MIN.
320
55
1145
560÷570
240
140
30
The hob must be fixed to the cabinet as follows:
1) Apply the sealing strip 8 mm from the hole.
2) Arrange the hob in the recess, making sure it is centred.
3) Fix the hob to the cabinet with the special stays supplied.
1 Sealant
1
1
Fitting in modular cabinets (model 12550 G-M)
8
31
FITTING IN MODULAR CABINETS (MODEL 12550 GF-M)
These hobs are arranged for fitting in modular kitchen units having a depth of between 550
and 600 mm and appropriate characteristics.
The hob dimensions are given in the “Technical Characteristics” section.
Fitting and fixing to the cabinet
The hob can be fitted in a cabinet having an opening
of the size illustrated. The opening must be at least
55 mm from the rear wall.
Any right or left side wall higher than the hob must
be at least 100 mm from the recess in the top.
The hob must be fixed to the cabinet as follows:
1) Prepare the hole in the top according to the
measurements indicated.
2) Mill the top along the entire edge of the
installation hole, making sure to respect the
measurements indicated.
3) Position the hooks, supplied as accessories, in
their seats, on the fixing profiles.
Fitting in modular cabinets (model 12550 GF-M)
550 MIN.
650 MIN.
593
60
550 MIN
.
5
5
5
6
0
÷
5
7
0
240
140
4
5
6
min 100
59
8,5
D (1:1)
1,5
R 11,5
1180
1183
1166
360
346
363
32
Fitting possibilities
On base cabinet with door
Adequate arrangements must be ensured in the construction of the cabinet, to prevent
possible contact with the overheated hob casing during operation. The recommended
solution for avoiding this problem is shown in the figure below.
The panel under the hob must be easily
removed to allow securing and release of the
hob in case of technical assistance.
4) Spread the silicone sealant around the hole, at the milling, and position the hob.
5) Carefully tighten the fixing hooks.
6) Remove any excess sealant.
60
60
1
2
min. 20
1 Removable cabinet panel
2 Possible space useful for connections
Fitting in modular cabinets (model 12550 GF-M)
60
33
On base cabinet with oven
The compartment must have the dimensions given in the figure on the previous page and
must have supports to allow efficient ventilation.
To avoid excessive overheating, it is advisable to carry out installation as shown in the figures
below.
The electrical connection of the hob and oven must be carried out separately, for electrical
reasons and to facilitate frontal oven removal.
Wall units or extractor hoods must be at least 650 mm from the hob.
In case of 600 mm wide hoods, as well as respecting the height, wall units next to the hood
must be positioned at a height of at least 550 mm from the top, to enable possible fitting of
the cover and its correct use.
ASSISTANCE AND REPLACEMENTS
Before leaving the factory this appliance was tested and adjusted by expert and specialised
personnel in order to ensure best operation. Any repairs or adjustments subsequently
required must be carried out with maximum care and attention.
Therefore always contact the Dealer who sold the product or our nearest After-Sales Service
Centre, specifying the type of problem, appliance model (Mod.), product number (Prod. No.)
and serial number (Ser. No.). These details are given on the label in the bag of injectors
supplied.
Original replacements, certified by the product manufacturer, and
identified by this mark, are only available at our After-Sales Service
Centres and Authorised Replacement Parts Shops.
Assistance and replacements
50 cm
2
360 cm
2
120 cm
2
180 cm
2
34
WARRANTY TERMS
Your new appliance is covered by warranty. The warranty terms are given in full in the “TOP
SERVICE” booklet included inside the appliance.
Carefully keep the receipt or waybill together with the “TOP SERVICE” booklet,
as documentation of the purchase (and purchase date) of your appliance.
Show these documents to the personnel in case of assistance by the After-Sales Service.
Otherwise the After-Sales Service will be obliged to charge you for any repairs.
Through its many authorised Centres, the After-Sales Service provides
assistance in Italy for the leading brands of electrical appliances. In case
of need, you can find the nearest Centre by consulting the “TOP SERVICE”
booklet or “AEG Service” in the Yellow Pages under the heading Electrical
Appliances/Repair.
Warranty terms
75
Características de los quemadores
CARACTERÍSTICAS TÉCNICAS
Potencia de los quemadores de gas
Quemador con triple corona 4,0 kW
Quemador rápido 2,9 kW
Quemador semirrápido 9,1 kW
Quemador auxiliar 1,0 kW
Categoría II2H3+
Ajuste aparato gas metano
G20 (2H)
20 mbar
Empalme de entrada del gas G 1/2
Tensión de alimentación 220-240 V
50-60Hz
Aparato de clase 3
Medidas de la placa de cocción
Ancho 1175 mm
Profundidad 350 mm
Medidas de la apertura para encastre
Ancho 1145 mm
Profundidad 320 mm
Diámetros del By-pass
Quemador Ø By-pass
de la llave
en centésimas
Auxiliar 33
Semirrápido 33
Rápido 45
Triple corona 65
Características técnicas
POTENCIA POTENCIA POTENCIA
TIPO TÉRMICA TÉRMICA TÉRMICA NOMINAL
DE NOMINAL REDUCIDA
QUEMADOR GAS NATURAL GAS LÍQUIDO
(Metano) (Butano/Propano)
kW kW 20 mbares 28-30/37 mbares
Marc. Marc. g/h
inyectores m
3
/h inyectores G30 G31
100/mm 100/mm
Quemador
auxiliar 1,0 0,52 70 0,095 50 73 71
Quemador
semirrápido 1,9 0,60 96 0,181 71 138 136
Quemador G.Natural:
rápido 2,9 1,10 119 0,276 86 204 200
G.P.L.: 2,8
Quemador
triple corona 4,0 1,80 146 0,381 98 291 286
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86

AEG HG924420NM User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI