Verona VDGCT212FSS Owner's manual

Category
Cookers
Type
Owner's manual
BUILT-IN GAS COOKTOPS
for residential use only
THIS COOKTOP IS FOR RESIDENTIAL USE ONLY
FOR INSTALLER ONLY
Models: VDGCT212F..
VDGCT424FSS
VDGCT530FSS
VDGCT536FSS
INSTALLATION INSTRUCTIONS
IMPORTANT - PLEASE READ AND FOLLOW
• Beforebeginning,pleasereadtheseinstructionscompletelyandcarefully.
• Donotremovepermanentlyafxedlabels,warnings,orplatesfromtheproduct.Thismay
voidthewarranty.
• Pleaseobservealllocalandnationalcodesandordinances.
• Pleaseensurethatthisproductisproperlygrounded.
• Theelectricalplugshouldalwaysbeaccessible.
• The installer should leave these instructions with the consumer who should retain
for local inspectors use and for future reference.
Installationmustconformwithlocalcodesorintheabsenceofcodes,theNationalFuelGas
CodeANSIZ223.1/NFPA54-Iatestedition.Electricalinstallationmustbeinaccordancewith
theNationalElectricalCode,ANSI/NFPA70-latesteditionand/orlocalcodes.
INCANADA:InstallationmustbeinaccordancewiththecurrentCAN/CGA-B149.1National
GasInstallationCodeorCAN/CGA-B149.2,PropaneInstallationCodeand/orlocalcodes.
ElectricalinstallationmustbeinaccordancewiththecurrentCSAC22.1CanadianElectrical
CodesPart1and/orlocalcodes.
INSTALLATIONINMANUFACTURED(MOBILE)HOME:Theinstallationmustconformwith
theManufacturedHomeConstructionandSafetyStandard,Title24CFR,Part3280[formerly
theFederalStandardforMobileHomeConstructionandSafety,Title24,HUD(Part280)]or,
when such standard is notapplicable,theStandardforManufacturedHomeInstallations,
ANSI/NCSBCSA225.1,orwithlocalcodeswhereapplicable.
INSTALLATIONINRECREATIONALPARKTRAILERS:Theinstallationmustconformwith
stateorothercodesor,intheabsenceofsuchcodes,withtheStandardforRecreationalPark
Trailers,ANSIA119.5.
Installationofanygas-redequipmentshouldbemadebyalicensedplumber.Amanualshut-
offvalvemustbeinstalledinanaccessiblelocationinthegaslineexternaltotheappliance
forthepurposeofturningonorshuttingoffgastotheappliance(InMassachusettssuchshut-
offdevicesshouldbeapprovedbytheBoardofStateExaminersofPlumbers&GasFitters).
Ifanexternalelectricalsourceisutilized,theappliance,wheninstalled,mustbeelectrically
groundedinaccordancewithlocalcodesor,intheabsenceoflocalcodes,withthenational
ElectricalCode,ANSI/NFPA70.
Some models are supplied with a protective lm on steel and aluminium
parts.Thislmmustberemovedbeforeinstalling/usingtheappliance.
R
2
Donotstoreorusegasolineorotherammablevaporsand
liquids in the vicinity of this or any other appliance.
NEVER use this appliance as a space heater to heat or
warmtheroom.Doingsomayresultincarbonmonoxide
poisoningandoverheatingoftheappliance.
WHAT TO DO IF YOU SMELL GAS:
• Donottrytolightanyappliance.
• Do not touch any electrical switch.
• Donotuseanyphoneinyourbuilding.
• lmmediately call your gas supplier from a neighbors
phone.Followthegassuppliersinstructions.
• lf you cannot reach your gas supplier, call the re
department.
Installationand service mustbe performed bya qualied
installer,serviceagency,orthegassupplier.
Iftheinformationinthismanualisnotfollowedexactly,
areorexplosionmayresultcausingpropertydamage,
personalinjury,ordeath.
WARNING !
3
CONVERSIONLABEL
DATAPLATE
This appliance is designed and manufactured solely for the cooking of domestic (household)
foodandinnotsuitableforanynonedomesticapplicationandthereforeshouldnotbeusedina
commercialenvironment.
Theappliancewarrantywillbevoidiftheapplianceisusedwithinanonedomesticenvironmenti.e.
asemicommercial,commercialorcommunalenvironment.
WARNING: This product can expose you to chemicals including
formaldehyde, which is known to the State of California to cause cancer,
and lead, which is known to the State of California to cause birth defects or other
reproductive harm. For more information go to www. P65Warnings.ca.gov.
4
TOOLS NEEDED FOR INSTALLATION (NOT SUPPLIED WITH THE APPLIANCE)
INSTALLATION INSTRUCTIONS
WARNING!
THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER.
Improperinstallation,adjustment,alteration,services,ormaintenancecancauseinjuryorpropertydamage.Consulta
qualiedinstaller,serviceagent,orthegassupplier.
IMPORTANT:Theuseofsuitableprotectiveclothing/glovesis
recommendedwhenhandling,installingofthisappliance.
Screwdriver Wrench
T-handle
wrench
Tape
measure
Angled
hexagon key Pencil
Adjustable
pliers
Adjustable
wrench
Suitable protective
gloves
5
GENERAL INFORMATION
1. Installationmustconformwithlocalcodesor,intheabsence
of local codes, with the National Fuel Gas Code, ANSI
Z223.1/NFPA54
-LatestEdition,CAN/CGA-B149.1orCAN/
CGA-B149.2.
2. Installationinmanufactured(mobile)home:installationmust
conform with the Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280 [formerly the
Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD (Part 280)] or, when such standard
is not applicable, the Standard for Manufactured Home
Installations, ANSI/NCSBCS A225.1, or with local codes
whereapplicable.
3. Installation in Recreational Park Trailers: installation must
conformwithstateorothercodesor,intheabsenceofsuch
codes, with the Standard for Recreational Park Trailers,
ANSI A119.5.
4.
WARNING!!
Thisapplianceshallnotbeusedforspaceheating.This
informationisbasedonsafetyconsiderations.
5. AlIopeningsinthewallbehindtheapplianceandintheoor
undertheapplianceshallbesealed.
6. Keep appliance area clear and free from combustible
materials,gasoline,andotherammablevapors.
7. Donotobstructtheowofcombustionandventilationair.
8. Disconnect the electrical supply to the appliance before
servicing.
9. Whenremovingapplianceforcleaningand/orservice;
A. Shutoffgasatmainsupply.
B. DisconnectACpowersupply.
C. Disconnectgaslinetotheinletpipe.
D. Carefullyliftapplianceoutofcabinetcutout.
CAUTION:Theapplianceisheavy;usecareinhandling.
10.
Electrical Requirement
Electrical installation should comply with national and local
codes.
11.
Air Supply and Ventilation
Theinstallermustreferstolocal/nationalcodes.
12.
Gas Manifold Pressure
Naturalgas-4.0”W.C.P.
LP/Propane-11.0”W.C.P.
WARNING!!
ELECTRICAL GROUNDING INSTRUCTIONS
The cooktop must be electrically grounded in accordance
withlocal codes or, in the absenceof localcodes,with the
NationalElectricalCode,ANSI/NFPANo.70-latestedition,in
Canada Canadian Electrical Code.
InstallationshouldbemadebyaIicensedelectrician.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
Ifanexternalelectricalsourceisutilized,theinstallationmustbe
electrically grounded in accordance with local codes or, in the
absenceof local codes,withthenationalElectricalCode,ANSI/
NFPA70.
This appliance is equipped with a three-prong grounding plug
(NEMA 5-15P) for your protection against shock hazard and
shouldbepluggeddirectlyintoaproperlygroundedsocket.
Do not under any circumstances cut or remove the third
(ground)prongfromthepowerplug.
REPLACEMENT PARTS
Only authorized replacement parts may be used in performing
service on the appliance. Replacement parts are available from
factory authorized parts distributors. Contact the nearest parts
distributorinyourarea.
6
1
installationtothecabinet
Fig.1.1a Fig.1.1b
Mod. VDGCT212F..
Mod. VDGCT530FSS
Mod. VDGCT424FSS
Mod. VDGCT536FSS
Table1-COOKTOPDIMENSIONS
(Figs.1.1a,1.1b,1.1c,1.1d)
W D
MODEL Inch mm Inch mm
VDGCT212F.. 11”21/64 288 20”1/16 510
VDGCT424FSS 23”5/8 600 20”1/16 510
VDGCT530FSS 29”17/32 750 20”1/16 510
VDGCT536FSS 35”7/16 900 20”1/16 510
Table2-CUT-OUT
DIMENSIONS
(Figs.1.2a,1.2b,
1.2c,1.2d)
W1 D1
RH
(*)(**)
LH
(*)(**)
R
(*)
T
(***)
MODEL Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm
VDGCT212F.. 10”5/8 270 19”9/32 490 5”63/64 152 5”63/64 152 2”11/64 55 11”13/32 290
VDGCT424FSS 22”3/64 560 18”57/64 480 7”7/8 200 11”13/16 300 2”11/64 55 23”5/8 600
VDGCT530FSS 29”9/64 735 18”57/64 480 7”7/8 200 11”13/16 300 3”5/32 80 29”17/32 750
VDGCT536FSS 33”5/64 840 18”57/64 480 7”7/8 200 11”13/16 300 3”5/32 80 35”7/16 900
(*) minimumdistancefromcut-out
(**) oneside(leftorright)abovethecounterheightmustalwaysbekeptclear
(***) minimumclearance,centredwiththecooktop
Fig.1.1c
Fig.1.1d
W
W W
W
D
D
D
D
7
1
Fig.1.2a
Fig.1.2b
Fig.1.3a Fig.1.3b
W1 RH
LH W1
D1
24”(610mm)
24”(610mm)
max
13”
(330
mm)
RH
LH
max
13”
(330
mm)
R
RD1
18”
(457mm)
T
T
30”
(762mm)
18”
(457mm)
30”
(762mm)
8
1
PROXIMITY TO SIDE CABINETS
1. The cooktop may be installed directly to existing base
cabinets. 24” (610 mm) minimum deep countertop is
required.
Cooktop dimensions:
AsperTable1atpageno.6.
Cut-out dimensions:
AsperTable2atpageno.6.
Theremustbeaminimumclearancebetweenthebackside
ofthecut-outandthebackofthecountertopasindicatedin
theTable2atpageno.6(measure“R”).
Important:Basecabinetconstructionmustallowforsizeof
cooktopcut-out.
Gaslineopening:
Wall - anywhere 8” 1/4 (210 mm) below underside of
countertop;
Cabinetoor-anywherewithin4”17/32(115mm)ofrear
wallisrecommended.
Grounded outlet:
Theelectriccordwith3-pronggroundplughasalengthof
48”(1220 mm).Groundedoutletshouldbe locatedwithin
36”(914.4mm)ofleft-centrerearsideofcut-out.
2. The cooktop CANNOT be installed directly adjacent to
sidewalls,tallcabinets,tallappliances,orothersidevertical
surfaces.Theremustbeaminimumclearancetotheright
orto the left above thecounterheightasindicatedinthe
Table2atpageno.6(measures“RH”and“LH”).
IMPORTANT: ONE SIDE (LEFT OR RIGHT) ABOVE THE
COUNTER HEIGHT MUST ALWAYS BE KEPT CLEAR.
3. The maximum upper cabinet depth recommended is
13” (330 mm). Wall cabinet above the cooktop must be
a minimum of 30” (762 mm) above the countertop for a
minimum width as indicated in the Table 2 at page no.6
(measureT”):ithastobecentredwiththecooktop.Side
wallcabinetsabovethecooktopmustbeaminimumof18”
(457mm)abovethecountertop.
4. If cabinet has a drawer, a 4” (102 mm) depth clearance
fromthetopofthecountertoptothetopofthedrawer(or
otherobstruction)inbasecabinetisrequired.Thedrawer
depthmay need tobe shortened toavoid interfering with
theregulator.
5. Aircurtainorotheroverheadrangehoods,whichoperate
byblowingadownwardairowontoagascooktop,shall
not be used in conjunction with gas cooktops other than
when the hood and cooktop have been designed, tested
and listed by an independent test laboratory for use in
combination.
FASTENING THE COOKTOP
(Model VDGCT212F..)
Each cooktop is provided with an installation kit including
bracketsandscrewsforfasteningthecooktoptobenchesfrom
20to40mm(13/16”to1”9/16)thick,gs.1.4a,1.4b.
• CuttheunitaccordingtoTable2atpageno.6.
• StretchgasketD”overtheedgeoftheholemade,being
carefultooverlaythejunctionedges
• Turnthecooktopoverandputtabs“A”intothemountings,
onlytightenscrews“B”afewturns.
Make sure that the tabs are mounted correctly as shown
inthegures.Turnthetabssothatthecooktopcanbeput
intothehole.
• Putthecooktopintotheholecutintotheunitandposition
itcorrectly.
• PuttabsA”intoplace,toothC”ofthetabsshouldgointo
thehole.
• Tightenscrews“B”untilthecooktopiscompletelysecured.
• Using a sharp tool cut off the part of gasket D” which
protrudesfromthecooktop.
Takecarenottodamagethebenchtop.
A
A
A
A
20
mm min.
40
mm max.
B
D
A
C
Fig.1.4b
Fig.1.4a
20mm
(13/16”)min.
40mm
(1”9/16)max.
9
1
FASTENING THE COOKTOP
(Models VDGCT424FSS, VDGCT530FSS,
VDGCT536FSS)
Each cooktop is provided with an installation kit including
bracketsandscrewsforfasteningthecooktoptobenchesfrom
30to40mm(3/16”to1”9/16)thick.
Models VDGCT424FSS and VDGCT530FSS (g. 1.5a): The
kitincludestwoF”typebrackets(forthefrontofthecooktop),
two“R”typebrackets(fortherearofthecooktop)andfourself-
threadingscrews“S”.
ModelVDGCT536FSS(g.1.5b):Thekitincludesfour“F”type
brackets(forthefrontofthecooktop),threeR”typebrackets
(for the rear of the cooktop) and seven self-threading screws
S”.
• CuttheunitaccordingtoTable2atpageno.6.
• StretchgasketG”overtheedgeoftheholemade,being
carefultooverlaythejunctionedges.
• FastenthebracketsF”andR”totheappropriatesocket
holes, without tightening the screws S” for the moment.
Makesurethatthetabsaremountedcorrectly,asshownin
thegures.Rotatethetabssothatthecooktopcanbeput
intothecutout.
• Putthecooktopintothecutoutandpositionitcorrectly.
• Put the brackets F” and R” into place; tooth A” of the
bracketsshouldgointothehole(gs.1.5c,1.5d).
• Tightenscrews“S”untilthecooktopiscompletelysecured
tothebench.
• Using a sharp cutter or trimmer knife, trim the excess
sealingmaterialaroundtheedgeofthecooktop.
Takecarenottodamagetheworkbench.
30 mm min.
40 mm max.
S
A
F
G
30 mm min.
40 mm max.
40 mm min.
40 mm min.
S
A
R
G
30 mm min.
40 mm max.
S
A
F
G
30 mm min.
40 mm max.
40 mm min.
40 mm min.
S
A
R
G
F
F
F
F
R
R
R
F
F
R
R
F
F
F
F
R
R
R
F
F
R
R
RearFixingBrackets
FrontFixingBrackets
Fig.1.5a
Fig.1.5b
Fig.1.5c
Fig.1.5d
30mm
(3/16”)min.
40mm
(1”9/16)max.
30mm
(3/16”)min.
40mm
(1”9/16)max.
10
Gas supply line
Shutoff valve
“open” position
To cooktop
2
gasconnection
2.PressureRegulator:
a. Allheavyduty,commercialtypecookingequipmentmusthaveapressureregulator
ontheincomingservicelineforsafeandefcientoperation,sinceservicepressure
mayuctuatewithlocaldemand.
Beforeinstallingtheregulatormountthe3/8”NPT(conical)maleconnectortothe
regulator(seepicture2.2c).
Gasketsuppliedhastobeplacedbetween3/8”NPT(conical)connector/extension
pipemalepipefitting(seepicture2.2d).
Theregulatorsuppliedwiththiscooktopmustbeinstalledbeforeanygasconnections
aremade.
Usesuppliedpressureregulatoronly.
Explosion Hazard
Use a new CSA or UL approved
gas supply line.
Install a shut-off valve.
Securely tighten all gas connec-
tions.
If connected to LP, have a quali-
fied person make sure gas pres-
sure does not exceed 14" water
column.
Examples of a qualified person
include licensed heating per-
sonnel, authorized gas compa-
ny personnel, and authorized
service personnel.
Failure to do so can result in
death, explosion, or fire.
Fig. 2.1
Allgasconnectionsmustbemadeaccordingtonationalandlocalcodes.Thisgassupply
(service)linemustbethesamesizeorgreaterthantheinletlineoftheappliance.Sealant
onallpipejointsmustberesistanttotheactionofLP/Propanegas.
ThecooktopisequippedfortheusewithNATURALgas.Itisdesign-certiedbyCSA
InternationalforNATURALandL.P.gaseswithappropriateconversion.
Themodel/serialratingplate,locatedontheundersideoftheburnerbox,hasinformation
onthetypeofgasthatcanbeused.Ifthisinformationdoesnotagreewiththetypeof
gasavailable, check with the localgassupplier. Seepage from14 to15forL.P.gas
conversioninstructions.
1. Manual Shut-off Valve(g:2.1):
Amanualshut-offvalvemustbeinstalledinanaccessiblelocationinthegaslineexternal
tothe appliance forthe purposeof turning on orshuttingoffgas to the appliance(In
MassachusettssuchshutoffdevicesshouldbeapprovedbytheBoardofStateExaminers
ofPlumbers&GasFitters).
Thisvalveshouldbelocatedinthesameroomasthecooktopandshouldbeinalocation
thatallowseaseofopeningandclosing(inapositionwhereitcanbereachedquicklyin
theeventofanemergency).
Donotblockaccesstotheshutoffvalve.Thevalveisforturningonorshuttingoffgas
totheappliance.
11
PRESSURE REGULATOR INSTALLATION
LOCK
Arrow
2
To cooktop
UNLOCK
LOCK
To cooktop
LOCK
STEP 1
Theelbowconnectioncanbeturnedinthedirectionrequiredafterthe
manifold female pipe fitting has been slackened by using a wrench.
Then tighten the elbow-manifold female pipe fitting connection by
using a wrench before proceeding with gas connection.
When tightening keep the elbow connection firm i.e. by using an
adjustable pliers or an adjustable wrench (pay attention not to
damage the thread).
STEP 2
Mount the extension pipe to the elbow connection interposing the
gasket supplied and tighten by using a wrench.
When tightening keep the elbow connection firm i.e. by using an
adjustable pliers or an adjustable wrench (pay attention not to
damage the thread).
STEP 3
Mountthe3/8”NPT(conical)maleconnectortothepressureregulator
and tighten by using a wrench.
Do not over tighten the connector.
Over tightening may crack regulator.
STEP 4
Assemblethe 3/8” NPTconnector +pressure regulator groupto the
extension pipe interposing the gasket supplied.
IMPORTANT: use two spanners to tighten the connection.
Fig. 2.2c
Fig. 2.2a
Fig. 2.2b
Fig. 2.2d
12
GAS CONNECTION SPECIFICATION
2
Gasket
Elbow
connection
Extension
pipe female
pipe tting
Extension
pipe
Extension
pipe male
pipe tting
Gasket
Gasket
Connector
Pressure
regulator
WARNING: check the right positioning
of the gas regulator. The arrow on the
back of the gas regulator must be
oriented towards the connector.
Manifold female pipe tting
Cooktop
manifold
To cooktop
Manifold
test point
pressure
1/8” NPT
Arrow
1/2” G cylindrical
(ISO 228-1) female
1/2” G cylindrical
(ISO 228-1) female
1/2” G cylindrical
(ISO 228-1) male
1/2” G cylindrical
(ISO 228-1) male
1/2” G cylindrical
(ISO 228-1) male
1/2” G cylindrical
(ISO 228-1) female
3/8” NPT
female
3/8” NPT
female
3/8” NPT (conical)
male
To mains
connection
Fig.2.3
13
b. Any conversion required must be performed by your dealer or a qualied
licensedtechnicianorgasservicecompany.Pleaseprovidetheserviceperson
withthismanualbeforeworkisstartedonthecooktop.(Gasconversionsarethe
responsibilityofthedealerorenduser.)
c. Thiscooktopcan be used withNATURALor LP/PROPANEgas. Itis shipped
fromthefactoryadjustedforusewithNATURALgas.
d. Manifoldpressureshouldbecheckedwithamanometer;NATURALgasrequires
4.0”W.C.P.andLP/PROPANErequires11.0”W.C.P.(seegurebelow).
• Incoming line pressure upstream from the regulator must be 1” W.C.P.
higherthanthemanifoldpressureinordertochecktheregulator.
• Theregulatorusedonthiscooktopcanwithstandamaximuminputpressure
of1/2PSI(14.0”W.C.P).Ifthelinepressureisinexcessofthatamount,a
step-downregulatorwillberequired.
e. The appliance, its individual shut-off valve, and pressure regulator must be
disconnectedfromthegassupplypipingsystemduringanypressuretestingof
thatsystematpressuresinexcessof1/2PSI(3.5kPa).
f. Theappliancemustbeisolatedfromthegassupplypipingsystembyclosingits
individualmanualshut-offvalveduringany pressuretestingof thegassupply
pipingsystemattestpressureequaltoorlessthan1/2PSI(3.5kPa).
3.FlexibleConnections:
Iflocalcodespermit,CSAorULdesign-certied,exiblemetalapplianceconnectoris
recommendedforconnectingthiscooktoptothegassupplyline.DoNotkinkordamage
theexibleconnectorwhenmovingthecooktop.Thepressureregulatorhas3/8”NPT
femalepipethreads.Youwillneedtodeterminethettingsrequired,dependingonthe
sizeofyourgassupplyline,exiblemetalconnectorandshutoffvalve.
4.RigidPipeConnections:
Ifrigidpipeisusedasagassupplyline,acombinationofpipettingsmustbeused
toobtainanin-lineconnectiontothecooktop.Allstrainsmustberemovedfromthe
supplyandfuellinessocooktopwillbelevelandinline.
• Use joint compounds and gaskets that are resistant to action of natural or
propanegasonallmalepipethreads.
• Do not over tighten gas tting when attaching to pressure regulator. Over
tighteningmaycrackregulator.
5.LeakTesting:
IMPORTANT:Leaktestingoftheapplianceshallbeconductedasfollows:
• After nal gas connection is made, turn on manual gas valve and test all
connectionsingassupplypipingandapplianceforgasleakswithasoapywater
solution.Duringthistestallappliancegasvalveshavetobeclosed.
• Inordertoavoidpropertydamageorseriouspersonalinjury,neveruseaIighted
match.Ifaleakispresent,tightenjointorunscrew,applymorejointcompound,
tightenagainandretestconnectionforleak.
2
To mains
connection
Manifold
test point
pressure
1/8” NPT
Screw
Unscrew
Fig.2.4
To cooktop
14
1
2
NATURAL GAS
REGULATION
LP/PROPANE
REGULATION
A
Fig.2.5
2
CONVERSION TO LP/PROPANEGAS (OR CONVERSION BACK TO THE
ORIGINAL GAS - NATURAL GAS)
Everycooktopisprovidedwithasetofinjectorsforthevarioustypesofgas.
Selecttheinjectorstobereplacedaccordingtothe“INJECTORSTABLE”.
Thenozzlediameters,expressedinhundredthsofamillimetre,aremarkedonthebodyofeachinjector.
CAUTION:Savetheoricesremovedfromtheapplianceforfutureuse.
SETTING THE PRESSURE REGULATOR
1. Unscrewtheregulatorcover.
2. Unscrewthe“A”component,reverseandscrewitaccordingtotheLP/PROPANE(orNATURALGAS)
regulation.
INJECTORS TABLE
NOMINAL
POWER
REDUCED
POWER
LP/PROPANE
11”W.C.P.
NATURAL GAS
4”W.C.P.
BURNERS BTU/hr BTU/hr
Øinjector
[1/100mm]
Øinjector
[1/100mm]
Auxiliaryburner 4000 1000 58 92
Semirapidburner 7000 1500 76 123
Rapidburner 10000 2500 92 148
Dualburner(Mod.VDGCT530FSS)
16000(
1
)
15000(
2
)
5000
50(x1)(
3
)
73(x2)(
4
)
72(x1)(
3
)
135(x2)(
4
)
Dualburner(Mod.VDGCT536FSS)
18000(
1
)
16500(
2
)
5000
50(x1)(
3
)
76(x2)(
4
)
72(x1)(
3
)
143(x2)(
4
)
(
1
)PowercalculatedwithNaturalGas
(
2
)PowercalculatedwithLP/Propane
(
3
)Innercrown(“J2”ingure2.6b)
(
4
)Outercrown(“J3”ingure2.6b)
VDGCT212F..
VDGCT530FSSVDGCT424FSS VDGCT536FSS
Semirapid
Semirapid Semirapid
Semirapid
Semirapid Semirapid
Semirapid
Dual
Dual
Rapid
Rapid Rapid
Rapid
Auxiliary Auxiliary
Auxiliary
15
2
J
Auxiliary,
Semirapid
and Rapid
burner
J1
J
J
Fig. 2.6a
Fig. 2.6b
Fig. 2.7
Dualburner
Injectorfor
innercrown
Injectors
forouter
crown
OPERATIONS TO BE PERFORMED WHEN
SUBSTITUTING THE INJECTORS
• Removethepansupports,theburnercapsandtheflame
spreaders.
• Using a wrench substitute the nozzle injectors J1”, J2”
andJ3”(figs.2.6a,2.6b)withthosemostsuitableforthe
kindofgasforwhichitistobeused.
• Refit the flame spreaders, the burner caps and the pan
supports.
The burners are conceived in such a way so as not to
requiretheregulationoftheprimaryair.
SETTING THE BURNER MINIMUM
Whenswitchingfromonetypeofgastoanother,theminimum
owratemustalsobecorrect:theameshouldnotgoouteven
whenpassingsuddenlyfrommaximumtominimumame.
Toregulatetheamefollowtheinstructionsbelow:
• Lighttheburner.
• Setthegasvalvetotheminimumrateposition.
• Removetheknob.
• With a thin screwdriver, turn the regulation screw A”
(g.2.7)untiladjustmentiscorrect.
For LP/PROPANE gas, tighten the adjustment screw
completely.
A
J2
J3
After regulation repeat the operations indicated in paragraph
“2.PRESSUREREGULATOR”atpage10.
If the cooktop has been disconnected and then connected
againtothegassupplylinerepeattheoperationsindicatedin
paragraph“5.LEAKTESTING”atpage13.
IMPORTANT:
• AfterconversiontoLP/PROPANEgashasbeencarriedout
afxnearthedataplatetheconversionlabelsuppliedand
also afx a conversion label at page 3 of this instruction
manual.
• Afterconversionbacktotheoriginalgas(NATURALGAS)
has been carried out remove, near the data plate and
at page 3 of this instruction manual, the LP/PROPANE
conversionlabels.Savethelabelsremovedforfutureuse.
16
3
electrical connection
If codes permit and a separate ground wire is used, it is recommended that a
qualiedelectriciandeterminethatthegroundpathisadequate.
Check with a qualied electrician if you are not sure whether the cooktop is
properlygrounded.
DoNotgroundtoagaspipe.
A120-volt,60-Hz,AC-only,15-ampere,fusedelectricalsupplyisrequired.
Atime-delayfuseorcircuitbreakerisrecommended.
Itisrecommendedthataseparatecircuitservingonlythisappliancebeprovided.
The outlet mustbe checkedby a qualied electrician tosee if it is wiredwith correct
polarity.
Thisappliance,wheninstalled,mustbeelectricallygroundedinaccordancewithlocal
codes.
Recommendedgroundmethod
Foryourpersonalsafety,thiscooktopmustbegrounded.
Thiscooktopisequippedwitha3-pronggroundplug.
To minimize possible shock hazard, the cord must be plugged into a mating 3-prong
ground-typeoutlet,groundedinaccordancewiththeNationalElectricalCodeANSI/NFPA
70latesteditionorCanadianElectricalCode(CSA)andlocalcodesandordinances.
Ifamatingoutletisnotavailable,itisthepersonalresponsibilityandobligationofthe
customer to have a properly polarized and grounded, 3-prong outlet installed by a
qualiedelectrician.
Electrical Shock Hazard
Plug into a grounded 3-prong
outlet.
Donotremovegroundprong.
Do not use an adapter.
Failure to follow these
instructions can result in death,
re,orelectricalshock.
Before any operation of
maintenance disconnect the
appliance from the electrical main
supply.
3-prong
ground
plug
Power
supplycord
Groundprong
3-prongpolarized
ground-typeoutlet
Fig. 3.1
17
Fig. 3.2
ELECTRIC DIAGRAM
3
WIRING DIAGRAM KEY
A IGNITIONCOIL
CA IGNITERS(2÷5DEPENDINGONMODEL)
PA IGNITIONSWITCHESGROUP(2÷5DEPENDINGONMODEL)
M TERMINALBLOCK
M
CA
CA
CA
CA
CA
PA
A
L
N
18
19
Cod.1106206-ß0
The manufacturer cannot be held responsible for possible inaccuracies due to
printingortranscriptionerrorsinthepresentbooklet.
Themanufacturerreservestherighttomakeallmodicationstoitsproductsdeemed
necessaryformanufactureorcommercialreasonsatanymomentandwithoutprior
notice,withoutjeopardisingtheessentialfunctionalandsafetycharacteristicsofthe
appliances.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Verona VDGCT212FSS Owner's manual

Category
Cookers
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI