Streamline V16 Controller User manual

Type
User manual
STREAMLINE
®
INSTRUCTION MANUAL
INSTR-SFC16
English
SFC16
Codes:
®
2W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 3
V16
Contents
6. Why Streamline®?
7. Streamline® Warranty
2. Operating Warnings
3. Set Up Auto Calibrate
4. Operation
5. Auto Fill Additional Wiring
1. Wiring
Controller Messages
Filling Modes
Auto Fill Operation
12
14
3
4
5 - 6
7
8
11
9
10
Wiring
Important
The Fuse for this unit is a 10A Fuse. Make sure correct fuse is fitted in-line, close
to the battery end of the RED (positive) wire. Failure to do so will result in
damage to the unit.
Connect the pump controller in accordance with this diagram.
NOTE: only fit the fuse once all connections are made
1Wiring
Enter Button
Down / Up Buttons
Fuse 10A
12V Battery Pump
Power Button
Display
STREAMLINE
®
®
4W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 5
2Operating Warnings
Operating Warnings Set Up Auto Calibrate
Important
Your battery is at risk of permanent damage if you disable low battery cut-o
and continue to use your controller for long periods when the battery voltage
has fallen below +10.5V.
Adjust the flow settings carefully. Repeated false dead-end detection indicates that the Cal value
should be increased (less sensitive).
For safety wire through the pump pressure switch. (The pressure switch can be bypassed if
absolutely necessary - the unit will protect itself under normal conditions.)
This is a WATER PUMP controller: it will not work with air in the system. Always prime the system
before starting work. If air in the system causes false dead-end detection, increase Cal value until air
is removed.
Do not set the Cal value too high. Setting it higher than necessary places extra strain on both the
pump and the controller in a dead end situation. This can result in damage to both the pump and
your controller.
Specification Value
Supply Voltage 11 - 15 VDC
Maximum Current 15A
Typical Drive Current 8A
Voltmeter Accuracy + - 100mV
Enclosure Material ABS
Water Resistance IP65
Dimensions 115 x 65 x 40 (mm)
Working Temperature 0 - 40 Deg C
3Set Up Auto Calibrate
Connect your hose and pole + brush to the pump.
Turn on the controller by pressing the power button.
Press and hold the up and enter buttons to
calibrate. CAL will be displayed.
To select Auto Cal continue to press the down
button until AUt is displayed. Press the enter
button to start. Auto Cal starts from C99.
After several moments the calculated CAL value
(e.g. C50) will be displayed and the controller is
ready to use. Press enter to exit calibration.
Press up until the display shows 30.
Display Button
STREAMLINE
®
6W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 7
Display Button
The CAL value can be adjusted manually by
following the same steps and adjusting the CAL
value by pressing the up or down button instead
of using AUt.
To enable or disable the low battery cut-o*
(that stops your pump when the battery voltage
is below 10.5V) press and hold the down and
enter buttons.
Then use the up or down button to select ON or OFF. Press enter to save.
NOTE:ON’ keeps your battery protected.
4Operation
To select Auto Cal continue to press the down
button until AUt is displayed. Press the enter
button to start. Auto Cal starts from C99.
Display Button
Press enter to display the current
battery voltage.
Press enter again to return to the current flow rate.
To turn the controller o, press the power button.
Operation
STREAMLINE
®
8W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 9
V16
The controller constantly monitors the dead end detection and low battery protection while in fill
mode to protect the system. Connect the pump controller in accordance with this diagram.
1. One time fill (stops when the level switch activates/lifts)
2. Fill on demand (refills every time the level switch drops)
To select the required filling mode press and hold the down and enter buttons. The controller will
display the fill on demand (FOd) menu.
Press up or down to change between on and o. O will set the controller to ‘one time fill’. On will
set the controller to ‘fill on demand’.
Press enter to display the next setting. Fill Delay will only appear when FOd is set to on.
Fdy is the time delay in minutes from the tank reaching full and the filling re-starting should the
water level drop. You can set this delay from 0-10 minutes with the up and down buttons. Setting to
‘0’ turns the delay o. Press enter to set.
The controller has two filling modes
Level Switch Auto Fill Solenoid Valve
Spring solenoid valves come fitted with grey wires and can be fitted either way round.
NOTE: only fit the fuse once all connections are made.
NOTE: solenoid wire pairs (grey/white/green/pink) must not be shorted/connected together
otherwise damage may occur to the controller and invalidate the warranty.
Important
The Fuse for this unit is a 10A Fuse. Make sure correct fuse is fitted inline, close
to thebattery end of the RED (positive) wire. Failure to do so will result in
damage to the unit.
,
,
5Auto Fill Additional Wiring
STREAMLINE
®
10 W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 11
To start filling the tank (when FOd is o) press and hold the up and down buttons. This will activate
the solenoid valve allowing water to fill the tank until the float switch detects that the tank is full.
The tank can be filled when the unit is on (even when pumping) or when the unit is turned o. While
the solenoid valve is on and the tank is filling, the display will flash FIL.
To manually stop the tank filling press and hold the up and down buttons again. The display will stop
showing FIL.
Fill on demand is eectively a tank level control that keeps the tank topped up to the level switch.
The solenoid valve will be turned o if the unit detects a low battery (below +10.5V).
Auto Fill Operation
STREAMLINE
®
12 W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 13
An error has occurred while using AutoCal. This will
happen when the motor is not connected or the enter
button has been pressed to cancel it.
Pressure switch activated or pump disconnected
A dead end has been detected. If this is not the case,
try increasing the calibration value.
This message will start to flash when the battery is low
(<11.0V). If the battery is below 10.5V the pump will be
disabled to protect the battery (unless low battery cut-
o is disabled)
An over current has been detected, the controller has
shut down the pump to protect itself. Lower the flow
rate and check the hose for blockages.
Message Description
Controller Messages
Streamline® systems can be built according to customers’ exact requirements
For non-standard systems, the user’s needs or specifications are listened to and turned
into reality.
Whilst price is important, quality is remembered long after price is forgotten
We insist on sourcing brand name products from around the world, only of a reputable
quality, and bring them together under the Streamline® name
All Streamline® products carry a full one year’s warranty, according to the manufacturers’
standard terms and conditions of sale.
We have an in-house technical helpline able to answer most of your questions relating to the
capabilities and functionalities of all Streamline® products
If we get it wrong, we will put it right. If you are sent a wrong item, we will immediately
attend to sending you the correct item and arrange a collection of the wrong item without
any quibbles
Streamline® is backed by a comprehensive range with massive stocks providing you with a
‘one stop shop’ for all your requirements.
Flexibility
Quality
Service
Why Streamline®?
MANUFACTURED
IN THE
UNITED KINGDOM
CHECKED AND
TESTED BY
QUALITY CONTROL
6Why Streamlin
STREAMLINE
®
®
14 W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 W: www.streamline.systems E: sales@streamline.systems T: +44 (0)1626 830 830 15
Notes
Streamline® Warranty
The warranty on all Machines and Equipment is
for 1 year (12-months) from RECORDED DATE
OF PURCHASE.
THIS WARRANTY EXCLUDES NORMAL
MAINTENANCE ITEMS, including but not limited
to HOSES, FILTERS, O-RINGS,
DIAPHRAGMS, VALVES, GASKETS,
CARBON BRUSHES and damage to motors
and other components as a result of failure to
replace normal maintenance items. THIS LIST
IS NOT EXHAUSTIVE.
If Streamline® receives notice of such defects
during the warranty period, Streamline®
will either, at its opinion, repair or replace
components which prove to be defective.
Replacement parts will only be supplied under
warranty, upon the inspection and approval of
the defective parts by Streamline®.
Should it be necessary to supply replacement
parts before the opportunity to inspect, these
will be charged at current prices and credit will
only be issued upon subsequent inspection and
warranty approval by Streamline®.
The customer is responsible for the cost of
return of the defective part. If warranty is
approved, Streamline® will pay for the cost
of the repaired or replacement part.
This warranty excludes the following conditions
and circumstances which are at the discretion
of Streamline®:
Wear and tear, misuse, abuse improper
maintenance, frost damage, the use of chemicals
other than those supplied or approved by
Streamline®, improper installation or repair,
unauthorised modification, incidental or
consequential costs, loss or damage, service,
labour or third party charges, the cost of
returning defective parts to Streamline®.
This warranty constitutes the exclusive remedy
of any purchaser of a Streamline® unit and is in
lieu of all other warranties, express or implied,
including without limitation any implied war-
ranty of merchantability or fitness for use, to
the fullest extent permitted by law. In no event
shall any implied warranty of merchantability or
fitness for use exceed the term of the applicable
warranty stated above and Streamline® shall
have no other obligation or liability.
Important
Unfortunately these rights cannot be
transferred to a third party.
6Streamline® Warranty
STREAMLINE
Hamilton House, 8 Fairfax Road,
Heathfield Industrial Estate,
Newton Abbot
Devon, TQ12 6UD
United Kingdom
Telephone: +44 (0) 1626 830 830
Email: sales@streamline.systems
Visit www.streamline.systems INSTR-SFC16
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Streamline V16 Controller User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI