Henny Penny BCF-65 User manual

Type
User manual

This manual is also suitable for

Henny Penny Model BCF-24/65, BCF/BCM-110
Henny Penny Blast Chiller/Freezer
Model BCF-110/BCM-110
FM01-679
Model BCF-24
Model BCF-65
Henny Penny Model BCF-24/65, BCF/BCM-110
LIMITED WARRANTY FOR HENNY PENNY APPLIANCES
Subject to the following conditions, Henny Penny Corporation makes the following limited warranties to the
original purchaser only for Henny Penny appliances and replacement parts:
NEW EQUIPMENT: Any part of a new appliance, except lamps and fuses, which proves to be defective
in material or workmanship within two (2) years from date of original installation, will be repaired or replaced
without charge F.O.B. factory, Eaton, Ohio, or F.O.B. authorized distributor. To validate this warranty, the
registration card for the appliance must be mailed to Henny Penny within ten (10) days after installation.
REPLACEMENT PARTS: Any appliance replacement part, except lamps and fuses, which proves to be
defective in material or workmanship within ninety (90) days from date of original installation will be repaired
or replaced without charge F.O.B. factory, Eaton, Ohio, or F.O.B. authorized distributor.
The warranty for new equipment and replacement parts covers only the repair or replacement of the defective
part and does not include any labor charges for the removal and installation of any parts, travel or other expenses
incidental to the repair or replacement of a part.
EXTENDED FRYPOT WARRANTY: Henny Penny will replace any frypot that fails due to manufacturing or
workmanship issues for a period of up to seven (7) years from date of manufacture. This warranty shall not cover
any frypot that fails due to any misuse or abuse, such as heating of the frypot without shortening.
0 TO 3 YEARS: During this time, any frypot that fails due to manufacturing or workmanship is-
sues will be replaced at no charge for parts, labor, or freight. Henny Penny will either install a new
frypot at no cost or provide a new or reconditioned replacement fryer at no cost.
3 TO 7 YEARS: During this time, any frypot that fails due to manufacturing or workmanship is-
sues will be replaced at no charge for the frypot only. Any freight charges and labor costs to install
the new frypot as well as the cost of any other parts replaced, such as insulation, thermal sensors,
high limits, fittings, and hardware, will be the responsibility of the owner.
Any claim must be represented to either Henny Penny or the distributor from whom the appliance was pur-
chased. No allowance will be granted for repairs made by anyone else without Henny Penny’s written consent. If
damage occurs during shipping, notify the sender at once so that a claim may be filed.
THE ABOVE LIMITED WARRANTY SETS FORTH THE SOLE REMEDY AGAINST HENNY PENNY
FOR ANY BREACH OF WARRANTY OR OTHER TERM. BUYER AGREES THAT NO OTHER REMEDY
(INCLUDING CLAIMS FOR ANY INCIDENTAL OR CONSQUENTIAL DAMAGES) SHALL BE AVAIL-
ABLE.
The above limited warranty does not apply (a) to damage resulting from accident, alteration, misuse, or abuse;
(b) if the equipment’s serial number is removed or defaced; or (c) for lamps and fuses. THE ABOVE LIMITED
WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUD-
ING MERCHANTABILITY AND FITNESS, AND ALL OTHER WARRANTIES ARE EXCLUDED. HENNY
PENNY NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER OB-
LIGATION OR LIABILITY.
FM01-679
Henny Penny Model BCF-24/65, BCF/BCM-110
TABLE OF CONTENTS
Section Page
Section 1. INTRODUCTION ................................................................................................................... 1-1
1-1. Henny Penny Blast Chiller Freezer ............................................................................. 1-1
1-2. Features ....................................................................................................................... 1-1
1-3. Proper Care ................................................................................................................. 1-1
1-4. Assistance .................................................................................................................... 1-1
1-5. Safety ........................................................................................................................... 1-2
Section 2. INSTALLATION...................................................................................................................... 2-1
2-1. Introduction .................................................................................................................. 2-1
2-2. Unpacking .................................................................................................................... 2-1
2-3. Electrical ...................................................................................................................... 2-2
2-4. Location ....................................................................................................................... 2-3
2-5. Refrigerant Information ............................................................................................... 2-4
2-6. Compressor size ........................................................................................................... 2-4
Section 3. OPERATION............................................................................................................................ 3-1
3-1. Introduction .................................................................................................................. 3-1
3-2. Operating Controls ....................................................................................................... 3-1
3-3. Basic Operation ........................................................................................................... 3-4
3-4. De-Icing ....................................................................................................................... 3-7
3-5. Cleaning ....................................................................................................................... 3-8
3-6. Seasonal or Prolonged Shutdown ................................................................................. 3-9
3-7. Programming ................................................................................................................ 3-10
Section 4. TROUBLESHOOTING ........................................................................................................... 4-1
4-1. Introduction .................................................................................................................. 4-1
4-2. Troubleshooting ............................................................................................................ 4-1
Section 5. MAINTENANCE .................................................................................................................... 5-1
5-1. Introduction .................................................................................................................. 5-1
5-2. Maintenance Hints ....................................................................................................... 5-1
5-3. Compressor, Drier, Expansion Valve, Sight Glass, and Condenser Fan ....................... 5-1
5-4. Display Board and Auxiliary Display Board ................................................................ 5-1
5-5. Control Board .............................................................................................................. 5-2
5-6. Buzzer .......................................................................................................................... 5-3
5-7. Contactor ..................................................................................................................... 5-3
5-8. Door Frame Heater ..................................................................................................... 5-4
5-9. Evaporator Fan ............................................................................................................ 5-4
5-10. Air Probe and Evaporator Probe ................................................................................. 5-5
5-11. Frigiprobe ..................................................................................................................... 5-5
5-12. Fuse and Fuse Holder .................................................................................................. 5-6
5-13. Condensation Evaporator .............................................................................................5-6
5-14. Door Seal ..................................................................................................................... 5-7
5-15. Run Capacitor .............................................................................................................. 5-8
5-16. Start Capacitor and Start Relay ................................................................................... 5-8
5-17. Preventive Maintenance .............................................................................................. 5-9
Wiring Diagram ...................................................................................................................... 5-11
Refrigeration Diagram ............................................................................................................ 5-11
Electrical/Refrigeration Diagram ............................................................................................ 5-12
498 i
Henny Penny Model BCF-24/65, BCF/BCM-110
TABLE OF CONTENTS (Continued)
Section Page
Section 6. PARTS INFORMATION ......................................................................................................... 6-1
6-1. Introduction .................................................................................................................. 6-1
6-2. Genuine Parts .............................................................................................................. 6-1
6-3. How to Order .............................................................................................................. 6-1
6-4. Prices ........................................................................................................................... 6-1
6-5. Delivery ....................................................................................................................... 6-1
6-6. Warranty ...................................................................................................................... 6-1
ii 498
Henny Penny Model BCF-24/65, BCF/BCM-110
SECTION 1. INTRODUCTION
1-1. BLAST CHILLER/ The Henny Penny Blast Chiller/Freezers are designed to carry
FREEZER out fast refrigeration and freezing of food products. The units
are electronically controlled for easy use and for consistent
operation.
1-2. FEATURES Interior and Exterior made of 304 Stainless Steel
Electronic Controls
Manual De-icing of the Interior
Multi-Sensored Frigiprobe food probe
Easily Maintained
Automatic Evaporation for Deicing water
The BCF-24 will Chill up to 10.9 kg (24 lbs) of Product
The BCF-65 will Chill up to 29.5 kg (65 lbs) of Product
The BCF-110 chills up to 50 kg. (110 lbs) of Product
HACCP Printer capabilities (optional)
1-3. PROPER CARE As in any unit of food service equipment, the Blast Chiller/
Freezer does require care and maintenance. Suggestions for
the proper care and maintenance are contained in this manual.
The conscientious use of the recommended procedures,
coupled with regular maintenance, will result in few repairs to
the equipment. When such repairs are required, they may be
accomplished by following the repair steps contained in this
manual.
1-4. ASSISTANCE Should you require outside assistance, just call your local
independent distributor maintained by Henny Penny Corporation.
In addition, feel free to contact our corporate headquarters in
Eaton, Ohio. Dial 800-417-8405 toll free, or 937-456-8405.
800 1-1
Henny Penny Model BCF-24/65, BCF/BCM-110
1-5. SAFETY The Henny Penny Blast Chiller/Freezer has may safety features
incorporated. However, the only way to ensure a safe operation
is to fully understand the proper installation, operation, and
maintenance procedures. The instructions in this manual have
been prepared to aid you in learning the proper procedures.
Where information is of particular importance or safety related,
the words WARNING, CAUTION, and NOTE are used. Their
usage is described below.
The word WARNING is used to alert you to a procedure,
that if not performed properly, might cause personal injury,
such as burns and/or loss of sight, and damage to the unit.
The word CAUTION is used to alert you to a procedure
that, if not performed properly, may damage the unit, or
product.
NOTE
The word NOTE is used to highlight especially important
information.
1-2 398
Henny Penny Model BCF-24/65, BCF/BCM-110
SECTION 2. INSTALLATION
2-1. INTRODUCTION This section provides the installation for the Henny Penny
Blast Chiller/Freezer.
NOTE
Installation of this unit should be performed only by a
qualified service technician.
Do not puncture the skin of the Blast Chiller/Freezer with
drills or screws, as component damage or electrical shock
could result. Also, Do Not lay the unit on its side. If the
unit has been on its side, the unit must be in an upright
position for at least an hour before power is applied to the
unit. Check all components for signs of being loose or
damaged, and make sure the system has refrigerant. Failure
to follow these instructions may cause damage to the compo-
nents.
2-2. UNPACKING The Henny Penny Blast Chiller/Freezer has been tested, in-
spected, and expertly packed to insure arrival at its destination
in the best possible condition. The rack supports are secured
inside the unit with cardboard, and the slides for the racks are
packed inside the unit. The cabinet rests on a wooden skid and
is then packed inside a heavy cardboard carton with sufficient
padding to withstand normal shipping treatment.
NOTE
Any shipping damage should be noted in the presence of
the delivery agent and signed prior to his or her depar-
ture.
To remove the Henny Penny Blast Chiller/Freezer from the
carton, you should:
1. Carefully cut banding straps.
2. Lift the carton off the unit.
3. Lift the unit off the skid.
The BCF-24 weighs about 250 lbs (112.5 kg), the BCF-65
about 340 lbs (153 kg), and the BCF/BCM-110 about
364 lbs (165 kg). Care should be taken when lifting unit to
prevent personnal injury.
800 2-1
Henny Penny Model BCF-24/65, BCF/BCM-110
2-2. UNPACKING 4. Open door and remove packing from racks, and the hori-
zontal slides from the inside of the unit.
5. Peel off any protective covering from the exterior of the
cabinet.
6. Install the slides onto the verticle racks.
7. Your Blast Chiller/Freezer is now ready for operation.
If the blast chiller/freezer has been laid on its side, the unit
must be sitting upright for at least an hour before applying
power to the unit. Check all components for signs of being
loose or damaged, and make sure the system has refrigerant.
Failure to follow these instructions may cause damage to the
components. Failure to follow these instructions could cause
damage to the compressor.
NOTE
Be certain to save any literature that is packed inside the
cabinet, or separate boxes.
2-3. ELECTRICAL The Blast Chiller/Freezer is available as a 208, 230, or 200
VAC, 50 or 60 Hz., single phase unit, both for domestic and
international use. The data plate, located on the left side of the
unit, will specify the correct electrical supply. The BCF-24 and 65,
are shipped with a 6 foot, 7 inch (2 m.) cord and plug, and requires
a grounded receptacle with a separate electrical line protected
by a fuse or circuit breaker of the proper rating.
The cabinet must be adequately and safely grounded
according to local electrical codes to prevent the possibil-
ity of electrical shock.
Refer to the table below for electrical ratings:
Model No. Volts Watts Amps Freq. Phase
BCF-24 208 2300 4.3 60 1
230 1800 9 50 1
200 1800 11 50 1
BCF-65 208 3000 7 60 1
230 2900 13 50 1
200 2500 12 50 1
BCF-110/ 208-240 4600 17 60 3
BCM-110 400 3100 9 50 3
200 3800 17 50-60 3
(Continued)
2-2 1000
Henny Penny Model BCF-24/65, BCF/BCM-110
2-4. LOCATION The BCF-24, BCF-65, and BCF/BCM-110 should be placed in
an area where the doors can be opened, for loading and unloading,
without interruption. For proper operation, the cabinet must be
level, and can be leveled by means of the adjustable legs.
For maximum efficiency, if the air temperature of the premises
is more than 100° F (38° C), the room should have adequate
ventilation, taking into account for the heat emitted by the unit.
Minimum clearances around the unit, especially from sources
of heat, are shown in the diagrams below:
900 2-3
Henny Penny Model BCF-24/65, BCF/BCM-110
2-5. REFRIGERANT Design Pressure
INFORMATION High Low
BCF-65 R404A 5.8 lbs (2.6 kg) 345 psig 190psig
(23.8 bar) (13.1 bar)
BCF-24 R404A 2.4 lbs (1.1 kg) 335 psig 195 psig
(23.1 bar) (13.4 bar)
BCF-110/ R404A 3.3 lbs (1.5 kg) 425 psig 174 psig
BCM-110 (29.3 bar) (12.0 bar)
2-6. COMPRESSOR SIZE BCF-24
.75 Horsepower
BCF-65
1.5 Horsepower
BCF/BCM-110
2.5 Horsepower
2-4 900
Refrigerant Type Amount of Refrig.
2-4. LOCATION (Continued)
BCF/BCM-110
Henny Penny Model BCF-24/65, BCF/BCM-110
SECTION 3. OPERATION
3-1. INTRODUCTION This section provides operating procedures for the Blast Chillers.
Sections 1, 2, and 3 should be read, and all instructions should be
followed before operating the cabinet.
This section also contains an explanation of all controls and compo-
nents and information on operating procedures and daily
maintenance.
If the blast chiller/freezer has been laid on its side, the unit
must be sitting upright for at least an hour before applying
power to the unit. Check all components for signs of being
loose or damaged, and make sure the system has refrigerant.
Failure to follow these instructions may cause damage to the
components. Failure to follow these instructions could cause
damage to the compressor.
3-2. OPERATING CONTROLS Pages 3-1 to 3-4 identifies and describes the function of all the
operating controls.
Fig. Item Description Function
No. No.
3-1 1 On/Off Button The On/Off button, when pressed, is a button on the
control panel that starts a chilling or freezing cycle. It
also must be pressed before any changes to the controls
can be made, and to start and stop the De-ice cycle.
3-1 2 Digital Display The Digital Display shows the temperatures, the time
(in a timing cycle), and the information in the technical
mode.
3-1 3 Up and Down The Up and Down Arrows are used when changing
Arrows times or settings.
3-1 4 Alarm Button The Alarm button is used to stop the optional alarm buzzer
and to enter the technical mode.
3-1 5 Temp Button The Temp button is used to select either the chilling
mode or the freezing mode.
3-1 6 De-ice Button The De-ice button is used to remove ice that may have
formed on the evaporator during a chilling or freezing
cycle.
800 3-1
Henny Penny Model BCF-24/65, BCF/BCM-110
3-2. OPERATING CONTROLS
(Continued)
Fig. Item Description Function
No. No.
3-1 7 Select Button The Select button is used to choose between a timing
cycle or a cycle using the food probe.
3-1 8 Fan LED The Fan LED is a green light which illuminates when
the fan is running.
3-1 9 Compressor LED The Compressor LED is a green light which illuminates
when the compressor is running.
3-1 10 End-of-Cycle LED The End-of-Cycle LED is a green light which illumi-
nates at the end of a timing cycle, or food probe cycle.
3-1 11 Alarm LED The Alarm LED is a red light which illuminates when
the unit senses a fault in the system. (Ex: AL 1, AL 2,
etc.).
3-1 12 Chill LED The Chill LED is a green light which illuminates when
the chilling mode is selected.
3-1 13 Freeze LED The Freeze LED is a green light which illuminates
when the freezing mode is selected.
3-1 14 De-ice LED The De-ice LED is a green light which illuminates
when the de-ice button is pressed.
3-1 15 Timer LED The Timer LED is a green light which illuminates when
the timing cycle is selected.
3-1 16 Frigiprobe LED The Frigiprobe LED is a green light which illuminates
when the food probe mode is selected.
3-2 298
Henny Penny Model BCF-24/65, BCF/BCM-110
997 3-3
Henny Penny Model BCF-24/65, BCF/BCM-110
3-3. BASIC OPERATION The Henny Penny Blast Chillers chills food products with a core
temperature of 149ºF (65ºC), down to 40ºF (4ºC) within 4 hours.
They also freeze food products with a core temperature of 149ºF
(65ºC), down to 0ºF (-18ºC) within 4 hours and 30 minutes, (room
ambiant temperature may impact time it takes to reach the desired
temperature). But, for the above statements to be accurate, the
following conditions must be met:
a. The food product must not be thicker than 1¾ to 2 inches
(40 to 50 mm.)
b. Meats should be placed directly onto the racks, but prod-
ucts in pans should be covered if possible. The steam from
the product can form ice on the evaporator, which will
increase the chilling or freezing time.
c. A minimum clearance of 1 inch (25 mm) between pans.
d. The best dishes or pans to use are stainless steel or alumi-
num. Do not use polycarbonate (plastic) pans. The poly-
carbonate acts as an insulator around the food product and
makes it hard to chill.
e. Do not exceed the product weight capacity specified by the
particular model of blast chiller.
MODEL Chill Capacity Freeze Capacity
BCF-24 24 lb. (10.8 kg) 16 lb. (7 kg)
BCF-65 65 lb. (28.8 kg) 32 lb. (15 kg)
BCF/BCM-110 110 lb. (50.0 kg) 55 lb. (24.75 kg)
Start-up
1. Load all the product at one time, so the door does not need
to be opened while in operation.
2. If using the food probe, place probe into product that is
located on the left side, middle of the unit.
3. Press the ON/OFF button to turn unit on. The fan and
compressor LEDs should come on after 25 seconds.
4. Press the Temp button to select the chilling mode or the
freezing mode.
NOTE
The chilling or freezing LEDs, and the timing or food
probe LEDs will stay on with the power switch turned to
the OFF position.
3-4 1000
Henny Penny Model BCF-24/65, BCF/BCM-110
3-3. BASIC OPERATION 5. Press the Select button to choose the food probe mode or
the timing mode. With the Frigiprobe mode selected, the
digital display will alternately show the core temperature of
the product, and the elapsed time of the cycle. If the timing
mode is selected, the digital display will alternately show
the air temperature and the time (hours and minutes) remain-
ing in the cycle.
NOTE
The buzzer will sound in 15 seconds after the food probe
mode is selected, unless the temperature is above 140ºF
(60ºC). Then the buzzer will sound when 140ºF (60ºC) is
reached.
6. Set the time in the timing cycle, if necessary, using the Up
and Down buttons. The time is affected by the thickness of
the food product, weight, food loading temperature, and
food’s packaging. The buzzer will sound 15 seconds into
the timing cycle.
NOTE
Avoid opening the door once the cycle has started. This
will lengthen the time it takes to reach the desired tempera-
ture.
7. At the end of the cycle (40ºF (4ºC) in the food probe mode)
the buzzer will sound and the unit will automatically start
the hold cycle. The buzzer will sound for 30 seconds, or
press the Alarm button to stop it. In the hold cycle, the
product will be held at 37ºF (3ºC) in the chilling mode, or
at -0.4ºF (-18ºC) in the freezing mode.
8. The product can remain in the unit for up to 12 hours, or
can be removed from the unit and placed in a cold storage
case.
(Continued)
298 3-5
Henny Penny Model BCF-24/65, BCF/BCM-110
3-3. BASIC OPERATION A temperature conversion chart is provided for your
(Continued) convenience:
3-6 498
Henny Penny Model BCF-24/65, BCF/BCM-110
3-4. DE-ICING Henny Penny recommends to perform the de-icing process after
every 3 cycles, and at the end of each day. This will eliminate any
ice that may have formed around the evaporator during the chilling
or freezing cycles. Failure the follow this procedure will increase
the time it takes to cool the product and may lead to unsafe prod-
uct.
1. Remove all product from the unit.
2. Open the door.
3. Press the ON/OFF button to turn the unit on.
4. Press the De-ice button. The digital display will now show
“d. 01”. The compressor will not come on, but the evapo-
rator fan will come on and pull room temperature air across
the evaporator.
5. Allow the de-ice cycle to run for a minimum of 10 minutes
and a maximum of 25 minutes. The unit will automatically
turn off when the evaporator has been de-iced, and reached
a temperature of 50ºF (10ºC).
NOTE
If the above procedures does not remove all the ice from
the evaporator, the length of time, and the temperature at
which the de-ice cycle turns the unit off, can be adjusted.
See the Programming section.
498 3-7
Henny Penny Model BCF-24/65, BCF/BCM-110
3-5. CLEANING Daily:
1. Remove all electrical power supplied to the unit by unplug-
ging the power cord from the wall, or by turning off the
wall circuit breaker.
2. Remove all product from the unit.
3. Remove the racks and pans from the unit and clean with
soap and water at a sink.
4. Clean all surfaces with a soft cloth, soap and water. DO
NOT USE ABRASIVE CLEANSERS.
DO NOT use abrasives, such a steel wool, or abrasive
cleaners, such as, chlorine, bromine, iodine, or ammonia
chemicals to clean the unit. These will deteriorate the
stainless steel and greatly reduce the life of the unit.
5. Clean around the electronic controls and the door seal with
a soft, damp cloth.
DO NOT use large quantities of water, or a spray hose to
clean the unit. Damage to the components could result.
6. Reconnect the electrical power to the unit and unit is now
ready for operation.
Monthly:
At least once a month the air condenser needs to be cleaned of
dust or obstructions for the unit to run effeciently and to reduce
energy use of the unit.
1. Remove all electrical power supplied to the unit by unplug-
ging the power cord from the wall, or by turning off the
wall circuit breaker.
2. Using a flathead screwdriver, remove the screws from the
front panel of the unit. Pull panel down and press in on the
side of the panel to release the tabs, and remove the panel
from the unit.
3-8 498
Henny Penny Model BCF-24/65, BCF/BCM-110
3-5. CLEANING (Continued) 3. Use a vacuum cleaner, or soft brush to remove the dust, or
other obstructions from the condenser.
4. Finish cleaning with compressed air if possible.
DO NOT use a wire brush to clean the condenser, or
damage to the condenser could result.
5. Replace the front panel, and reconnect the electrical supply,
and unit is now ready for use.
3-6. SEASONAL OR 1. Remove all electrical power supplied to the unit by un-
plugging the power cord from the wall, or by turning off
the wall circuit breaker.
2. Make sure the inside of the unit is clean and completely
dry.
3. Leave the door slightly ajar to prevent smells from devel-
oping inside the unit.
PROLONGED SHUTDOWN
498 3-9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Henny Penny BCF-65 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI