Metrologic IS1000 Series User manual

Category
Bar code readers
Type
User manual

This manual is also suitable for

IS1000 Series
Radio Frequency Bar Code Reader
Configuration Guide
Metrologic Instruments GmbH
Dornierstrasse 2
82178 Puchheim
GERMANY
Tel. : +49 (0) 89 890 19 0
Fax : +49 (0) 89 890 19 200
IS1000 – Configuration Guide
i
Metrologic Instruments GmbH makes no guaranteed declaration or offer concerning the contents
or use of this manual, and notably refutes any express or implicit liability as regards the
merchandisable quality or suitability for a particular use of the product.
In addition, Metrologic Instruments GmbH reserves the right to update this publication and to
make changes at any time without notice.
Metrologic Instruments GmbH refutes any liability concerning any modifications that might be
made to the commodities supplied.
You use this equipment at your own risks and perils.
Metrologic Instruments GmbH will not be held liable for any direct or indirect losses or damage
resulting from its use.
Moreover, Metrologic Instruments GmbH reserves the right to modify its products, entirely or in
part, at any time without notice.
This hardware is guaranteed by Metrologic Instruments GmbH for one year from the date of
delivery. During this period, any defective equipment item will be repaired or replaced without
charge.
Copyright ï›™ 2001 Metrologic Instruments GmbH. All rights reserved.
This manual is intended for the private use of the recipient, whether supplied on paper or in
electronic form.
It may not be modified or copied by any means whatsoever without written authorization from
Metrologic Instruments GmbH.
All names of products mentioned in this documentation are registered trademarks of their
respective manufacturers.
MLPN XX-XXXXX
January 2002
IS1000 – Configuration Guide
ii
Metrologic Instruments GmbH
Donierstrasse 2
82178 Puchheim
GERMANY
Tel.: +49 (0)89 890 190 Fax: +49 (0)89 890 19 200
Metrologic Instruments Italia S.r.L.
Via Emilia 70
40064 Ozzano Dell'Emilia (BO)
ITALY
Tel.: +39 051 651 19 78 Fax: +39 051 652 13 37
Metrologic Eria Ibérica S.A.
Julian Camarillo 29, D1 Bajo
28037 Madrid
SPAIN
Tel.: +34 91 327 24 00 Fax: +34 91 327 38 29
Metrologic Eria Ibérica S.A.
Consell de Cent 106 – 108 – 3° 3a
08015 Barcelona
SPAIN
Tel.: +34 93 423 11 10 Fax: +34 93 423 14 76
Metrologic Eria France S.A.
Z.I. Paris Nord II, 69, rue de la Belle Etoile, Bât. E – B.P. 50057
95947 Roissy CDG Cedex
FRANCE
Tel.: +33 (0)1 48 63 78 78 Fax: +33 (0)1 48 63 24 94
Metrologic Instruments U.K., Ltd.
58 Tempus Business Centre, Kingsclere Road
Basingstoke, Hampshire RG21 6XG
UNITED KINGDOM
Tel.: +44 (0) 1256 365 900 Fax: +44 (0) 1256 365 955
IS1000 – Configuration Guide
iii
TABLE OF CONTENTS
1. INTRODUCTION............................................................................................................. 1
1.1. Default Configuration (factory setting)..............................................................3
2. COMMUNICATION MODES........................................................................................... 5
2.1. RS232.................................................................................................................... 6
2.1.1. Baud Rate..................................................................................................6
2.1.2. Data Bits ....................................................................................................7
2.1.3. Parity.......................................................................................................... 7
2.1.4. Stop Bits ....................................................................................................7
2.1.5. End of Message Character ........................................................................ 8
2.1.6. Time-Out Between Characters ..................................................................9
2.1.7. ACK/NAK Protocol...................................................................................10
2.1.8. XON/XOFF Protocol ................................................................................ 10
2.1.9. RTS/CTS Protocol ................................................................................... 10
2.1.10. PC-Term Mode ........................................................................................ 11
2.2. Keyboard-Wedge ............................................................................................... 12
2.2.1. End of Message Character ...................................................................... 14
2.2.2. Upper / Lower Case Options ................................................................... 14
2.2.3. Types of Numeric Characters .................................................................. 15
2.2.4. Time-Out Between Characters ................................................................15
2.2.5. "WYSE" Time-Out....................................................................................16
2.3. P.O.S. (Point Of Sale) Systems......................................................................... 17
2.4. Wand Emulation................................................................................................. 18
2.4.1. Transmission Speed ................................................................................ 18
2.4.2. Bar/Space Polarity ................................................................................... 19
2.4.3. Idle State.................................................................................................. 19
2.5. Laser Emulation................................................................................................. 20
3. SYMBOLOGIES ...........................................................................................................21
3.1. Symbology Selection ........................................................................................22
3.2. Code 39............................................................................................................... 24
3.2.1. Standard/Full ASCII ................................................................................. 24
3.2.2. Full ASCII Extended ................................................................................ 24
3.2.3. Multiread .................................................................................................. 25
3.2.4. Modulo 43 Check Character .................................................................... 25
3.2.5. Pharmacode or Pharma 32/39................................................................. 26
3.2.6. CIP Code 39 ............................................................................................ 26
3.2.7. Start/Stop.................................................................................................27
3.2.8. Modulo 43 Algorithm................................................................................27
3.3. Interleaved 2/5.................................................................................................... 28
3.3.1. Fixed Length(s) Authorized and Set Upon First Reading(s) .................... 28
3.3.2. Fixed Length(s) Authorized and Set Using the Numeric Pad .................. 29
3.3.3. Variable Lengths Authorized.................................................................... 30
3.4. UPC/EAN............................................................................................................. 31
IS1000 – Configuration Guide
iv
3.4.1. Types of UPC/EAN Authorized................................................................ 31
3.4.2. Transformations.......................................................................................31
3.4.3. Add-On Options ....................................................................................... 32
3.4.4. Leading Prefixes for P.O.S. Systems ...................................................... 33
3.4.5. Flag Option ..............................................................................................33
3.4.6. Check Digit Options ................................................................................. 34
3.4.7. Product Code...........................................................................................34
3.4.8. ISBN Conversion ..................................................................................... 34
3.5. Monarch/Codabar .............................................................................................. 35
3.5.1. Start/Stop.................................................................................................35
3.5.2. Concatenation.......................................................................................... 35
3.6. Code 128............................................................................................................. 36
3.6.1. Check Character......................................................................................36
3.6.2. FNC2 Function......................................................................................... 36
3.7. UCC/EAN 128 .....................................................................................................37
3.8. Standard 2/5 ....................................................................................................... 38
3.8.1. Number of Lengths Authorized ................................................................ 38
3.8.2. Start/Stop Types ...................................................................................... 38
3.9. MSI ...................................................................................................................... 39
3.9.1. Variable or Fix Lengths............................................................................ 39
3.9.2. Double Check Digit (Modulo 10).............................................................. 39
3.9.3. Single Check Digit (Modulo 10) ............................................................... 39
3.10. Plessey ...............................................................................................................40
3.11. Telepen ............................................................................................................... 40
3.12. Code 93............................................................................................................... 40
3.13. Matrix 2/5 ............................................................................................................ 41
3.13.1. Types of Start/Stop ..................................................................................41
3.13.2. Check Digit ..............................................................................................41
3.13.3. Fixed or Variable Lengths........................................................................ 41
3.13.4. Setting the Authorized Lengths................................................................42
3.14. IATA ....................................................................................................................43
3.15. BC 412................................................................................................................. 43
3.16. 3W7 .....................................................................................................................43
3.17. Leading Identifiers............................................................................................. 44
3.17.1. Identifier with One Character ...................................................................44
3.17.2. Identifier with Three Characters............................................................... 44
3.18. Decoding Selectivity.......................................................................................... 45
4. OPERATING MODES................................................................................................... 47
4.1. Simple Acknowledgment ..................................................................................47
4.2. Host System Acknowledgment ........................................................................ 48
4.3. On File / Not On File ..........................................................................................48
4.3.1. Setting the On File Character .................................................................. 49
4.3.2. Setting the Not On File Character............................................................ 49
4.4. Bell ...................................................................................................................... 50
IS1000 – Configuration Guide
v
4.5. Setting the Timers .............................................................................................51
4.5.1. Timer T1 ..................................................................................................51
4.5.2. Timer T2 ..................................................................................................52
4.5.3. Timer T3 ..................................................................................................52
5. EDITING MODE............................................................................................................ 53
6. APPENDIXES...............................................................................................................55
6.1. Radio Parameters .............................................................................................. 55
6.1.1. Radio Channel ......................................................................................... 55
6.1.2. Number of Re-transmissions ................................................................... 56
6.2. Adjustment of the Beep Sound ........................................................................ 57
6.2.1. Laser Reader ........................................................................................... 57
6.2.2. Radio Base ..............................................................................................57
6.3. Preamble / Postamble .......................................................................................58
6.3.1. Preamble Character................................................................................. 58
6.3.2. Postamble Character ............................................................................... 58
6.3.3. Clear Buffer.............................................................................................. 58
6.4. Conversion of Characters................................................................................. 59
6.4.1. First Character ......................................................................................... 59
6.4.2. Second Character....................................................................................61
6.5. Rolling Buffer Mode........................................................................................... 62
6.6. Transmission of the Full ASCII Character Set ................................................ 63
6.7. Displaying the Firmware Level ......................................................................... 64
6.8. Code 39 Full ASCII Extended Table .................................................................65
6.9. Multiread character Table .................................................................................67
6.10. Code 39 Full ASCII Table ..................................................................................70
6.11. Numeric Pad....................................................................................................... 81
6.12. Samples of Bar Codes.......................................................................................82
IS1000 – Configuration Guide
vi
Page intentionally left blank
IS1000 – Configuration Guide
1
1. INTRODUCTION
This manual contains information about configuration IS1000 laser reader and decoder present
in the radio base.
The installation procedures and technical description are described in the IS1000 Installation
and User’s Guide.
The IS1000 Connection List contains the connection numbers (or ID) and the cable references
to be used for Keyboard-Wedge communication on PCs and terminals, for communication with
P.O.S. systems and Notebooks. For other types of connections see chapter 2, Communication
Modes.
IS1000 – Configuration Guide
2
Once the radio base is powered on, each parameter value can be changed simply by scanning,
with the laser reader, the codes appearing in this manual with respect to configuration sequence.
Chapter 2 Page 5
Chapter 3 Page 21
Chapter 4 Page 47
Chapter 5 Page 53
Chapter 6 Page 55
There is no need to adjust all the parameters. Change only the ones concerning your application.
Unchanged parameters will keep their previous value.
The parameter values are stored in a non-volatile memory called EEPROM and are saved when
the radio base is turned off.
SYMBOLOGIES
Selection and adjustment of options
START OF CONFIGURATION
bottom left of each page
END OF CONFIGURATION
bottom right of each page
COMMUNICATION MODES
Selection of the communication mode and adjustment of the transmission parameters
! Note:
OPERATING MODES
Selection of the operating mode and adjustment of options
EDITING MODE
Adjustment of data formats
APPENDIXES
Adjustment of data formats
IS1000 – Configuration Guide
3
1.1. Default Configuration (factory setting)
When shipped from the factory, each IS1000 is configured with default parameter values
as follows:
Default Configuration
Communication Mode
RS232 mode:
- 9600 bps
- Even parity
- 7 data bits
- 1 stop bit
- CR/LF end of message characters
Symbology
Code 39, Code 128, EAN 128, UPC/EAN, Interleaved 2/5,
Monarch/Codabar
Radio 433 MHz – Channel 3
Operating Mode
- Simple acknowledgment mode
- Timer 1 = 200 ms
- Timer 2 = 3 s
- Timer 3 = 2 s
- Number of re-transmissions = 3
Buzzer High volume
These are the main parameters, please check the sections of this manual which concern
your application.
The default value of each parameter appears like this:
The text below the code is framed and ended by the sign * to indicate the default value.
At any time, the default values of all the parameters can be set by scanning this code:
The reading of this code will turn all parameters to their default value.
FUNCTION X ACTIVATED *
3 to 5 characters
Code 39
! Caution:
DEFAULT CONFIGURATION
IS1000 – Configuration Guide
4
Page intentionally left blank
IS1000 – Configuration Guide
5
START OF CONFIGURATION END OF CONFIGURATION
2. COMMUNICATION MODES
The radio base is equipped with a decoder offering a multi-interface communication port.
The default communication mode is RS232 (9600 baud, 7 data bits, parity even, 1 stop bit, end
message: CR LF).
Other communication modes can be selected by using the following sequence:
Read the code Start of Configuration
bottom left of each page
Read the code End of Configuration
bottom right of each page
Select the mode of communication
Adjust the transmission parameters
IS1000 – Configuration Guide
6
START OF CONFIGURATION END OF CONFIGURATION
2.1. RS232
Use the codes on this page through to page 11 to activate and adjust the RS232
parameters.
2.1.1. Baud Rate
RS232 MODE ACTIVATED *
38400
2400
19200
1200
9600 *
600
4800
300
IS1000 – Configuration Guide
7
START OF CONFIGURATION END OF CONFIGURATION
2.1.2. Data Bits
2.1.3. Parity
2.1.4. Stop Bits
7 *
8
EVEN *
MARK
ODD SPACE
1 *
2
IS1000 – Configuration Guide
8
START OF CONFIGURATION END OF CONFIGURATION
2.1.5. End of Message Character
One character can be systematically transmitted with each code to indicate the
end of message:
Other characters or complete fields can be added to the message using the
Preamble / Postamble function (see appendix 6.3, page 58) or the Editing Mode
(see chapter 5, page 53).
CR/LF *
STX…ETX
HT SUITE (MINITEL)
NONE LF
CR EOT
IS1000 – Configuration Guide
9
START OF CONFIGURATION END OF CONFIGURATION
2.1.6. Time-Out Between Characters
In case that errors are detected using high speed transmissions such as 19200 or
38400 baud and if two stop bits are already set, a time-out can be inserted
between each character for a better synchronization:
100 ms
0 ms *
10 ms
20 ms 50 ms
IS1000 – Configuration Guide
10
START OF CONFIGURATION END OF CONFIGURATION
2.1.7. ACK/NAK Protocol
Once this protocol is activated, the decoder waits for an acknowledgment from the
host system:
• ACK (06 hexa) means: message correctly received by the host system.
• NAK (15 hexa) means: message incorrectly received by the host, upon
reception of this character the decoder resends the
message.
2.1.8. XON/XOFF Protocol
Using this protocol, the host system can control the data flow coming from the
decoder:
• XON (11 hexa) means: host system ready to receive data.
• XOFF (13 hexa) means: host system busy, the decoder stops the transmission
and waits for an XON.
2.1.9. RTS/CTS Protocol
This protocol is a hardware "handshake" between the decoder and the host
system. Before transmitting data, the decoder rises its RTS signal (pin 4) to +10
volt and waits for a +10 volt signal on its CTS (pin 5) from the host. The rest
position of the two pins is -10 volt.
ACK/NAK DISACTIVATED *
ACK/NAK ACTIVATED
XON/XOFF DISACTIVATED *
XON/XOFF ACTIVATED
RTS/CTS PROTOCOL DISACTIVATED *
RTS/CTS PROTOCOL ACTIVATED
IS1000 – Configuration Guide
11
START OF CONFIGURATION END OF CONFIGURATION
2.1.10. PC-Term Mode
Some applications use several RS232 terminals connected to a PC host system
configured in PC-Term mode. When a character is typed on a keyboard of a
terminal, its scan code value is transmitted to the PC instead of its ASCII value.
Then, upon reception, the PC sends back the corresponding ASCII character to
display on the screen.
Therefore, once this mode is activated, the decoder sends the scan code value of
each character read.
To activate the PC-Term mode, read this code and adjust the RS232 parameters
using page 6 to 10. It is advised to insert a time-out of 50 ms between each
character when baud rate is over 9600 baud (see page 9).
Upper/lower case characters and the type of numeric characters can be adjusted
using page 14 and 15.
Keyboard layout style can be selected using the Bar Code Pad page 12, without
reading the code Keyboard-Wedge Mode Activated.
PC-TERM MODE ACTIVATED
IS1000 – Configuration Guide
12
START OF CONFIGURATION END OF CONFIGURATION
2.2. Keyboard-Wedge
In this mode the radio base is connected between the keyboard and the computer (or
terminal). Data is emulated by the decoder as if it was typed on the keyboard.
The default communication mode (factory setting) is RS232, use the codes on this page to
activate the Keyboard-Wedge mode and to select the ID corresponding to your computer
or terminal:
Consult the IS1000 Connection List and enter the ID
corresponding to your computer or terminal using this Bar Code Pad
KEYBOARD-WEDGE MODE ACTIVATED
0 1
2 3
4 5
6 7
8 9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

Metrologic IS1000 Series User manual

Category
Bar code readers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI