Robinair High Performance Vacuum Pump 15401 User manual

Type
User manual

Robinair High Performance Vacuum Pump 15401 is a high-quality vacuum pump engineered specifically for air conditioning and refrigeration service. It features an offset rotary vane design, which provides powerful, quiet, high vacuum capability and ensures moisture removal. The pump also has a high pumping capacity, which reduces evacuation time.

Some of the key features of the Robinair High Performance Vacuum Pump 15401 include:

  • Iso-ValveTM: Allows the pump to be shut off while still connected to the A/C-R system, which is handy for checking rate of rise.
  • High vacuum rating: The two-stage, offset rotary vane design provides powerful, quiet, high vacuum capability and ensures moisture removal.

Robinair High Performance Vacuum Pump 15401 is a high-quality vacuum pump engineered specifically for air conditioning and refrigeration service. It features an offset rotary vane design, which provides powerful, quiet, high vacuum capability and ensures moisture removal. The pump also has a high pumping capacity, which reduces evacuation time.

Some of the key features of the Robinair High Performance Vacuum Pump 15401 include:

  • Iso-ValveTM: Allows the pump to be shut off while still connected to the A/C-R system, which is handy for checking rate of rise.
  • High vacuum rating: The two-stage, offset rotary vane design provides powerful, quiet, high vacuum capability and ensures moisture removal.
High Performance Vacuum Pump
Model 15401/15601/15603/15605
Operating Manual .........................................2
Bombas de Vacío de Alto Rendimiento
Modelo 15401/15601/15603
Manuel del Operador ....................................8
Pompe à Vide à Haut Rendement
Modèle 15401/15601/15603
Manuel d’utilisation .....................................16
Hochleistungs-Vakuumpumpe
Modelle 15401/15601/15603
Bedienungsanleitung ..................................24
Table of contents
Robinair® high performance
vacuum pumps .....................................................2
Pump components................................................3
Warnings .............................................................3
Before using your vacuum pump ..........................4
To use the gas ballast feature...............................5
To shut down your pump after use .......................5
To maintain your high vacuum pump ....................5
Vacuum pump oil .............................................5
Oil change procedure ......................................5
Cleaning your pump.........................................5
Motor lubrication .............................................5
Troubleshooting guide ..........................................6
Failure to start.......................................................6
Oil leakage .......................................................6
Failure to pull a good vacuum..........................6
Pump specications..............................................6
Replacement parts ...............................................7
Warranty coverage ...............................................7
Out of warranty ................................................7
Operating Manual
2
Robinair® high performance
vacuum pumps
Congratulations on purchasing one of Robinair’s
top quality vacuum pumps. Your pump has been
engineered specically for air conditioning and
refrigeration service, and is built with Robinair’s
proven offset rotary vane for fast, thorough
evacuation.
You’ll appreciate these key features . . .
Iso-Valve
TM
Allows the pump to be shut off while still connected to
the A/C-R system, which is handy for checking rate
of rise. With the valve handle in the OPEN position,
the pump is open to the system being evacuated.
In the CLOSE position, the pump is isolated from
the system. This minimizes pump oil pulled into
the pumping module, making start-up easier and
reducing wear and tear on the pump components.
High vacuum rating
The two-stage, offset rotary vane design provides
powerful, quiet, high vacuum capability and ensures
moisture removal, while the high pumping capacity
reduces evacuation time.
Lifetime ltration
The intake lter prevents foreign matter from entering
the pumping chamber, and an internal exhaust lter
separates oil vapor from the exhaust ow.
Directed exhaust
The exhaust is expelled through the handle to direct it
away from the service technician.
Gas ballast
A precise amount of atmospheric air is introduced
into the pump, preventing condensation of moisture
vapor and helping maintain the purity of the pump oil.
By using the gas ballast, the pump operates more
efciently and pump life is extended.
Sure-grip handle
The one-piece, molded handle makes it easy to carry
the pump to and from job sites, and the handle stays
cool to the touch during operation.
Compact design
The pump measures approximately 40 cm long, while
aluminum housing and offset rotary vanes keep the
pump weight low, making it easy to carry.
For use on A/C-R systems
using CFCs, HCFCs and HFCs
in conjunction with mineral oil,
ester oil, alkylbenzene oil and
PAG oil as lubricants. Not for
use with ammonia or lithium
bromide systems. Not for use
with ammable refrigerants.
Operating Manual
3
Pump Components
1.IntakeFitting
2.GasBallastValve
(locatedbesidehandlebase)
3.OilFillPort
4.SightGlass
5.Die-CastAluminumHousing
6.OilDrain
7.MoldedPolycarbonateBase
8.Iso-Valve
TM
(isolatesthepumpfromthesystem)
9.HighTorqueMotor
10.PowerSwitch
11.Through-the-HandleExhaust
12.Sure-GripHandle
Warnings
Wear goggles when working with
refrigerants. Contact with refrigerants
may cause injury.
Incorrect use or connections may
cause electrical shock. Study and
follow the instructions carefully. and
take precautions to avoid electrical
shock hazards. All associated devices
must be grounded before energizing
circuits.
The normal operating temperature
will cause certain external portions of
the pump to be hot to the touch. Do
not touch the pump housing or motor
during operation.
NOTICE: Airborne Noise Emissions
This equipment has been tested for airborne noise emission per
the Council Directive for Machinery (89/392/EEC) Section 1.7.4
Instructions — Essential Health and Safety Requirements.
Sound levels do not exceed 80dB(A) actual value.
1
2
3
4
5
6
7
8
9
10
11
12
116292Rev.FJune18,2013
Inallcases,motorsaredesignedforoperating
voltagesplusorminus10%ofthenormalrating
(seeSPECIFICATIONS).
1.Verifythevoltageandfrequencyattheoutlet
matchthespecicationsonthepumpmotor
decal.VerifytheON/OFFswitchisinthe
OFFpositionbeforeyouplugthepump
intoanoutlet.Verifythegasballastvalveis
closed.Removeanddiscardtheexhaustplug
fromtheendofthepump’shandle.
2.Thepumpisshippedwithoutoilinthe
reservoir.Beforestartingthepump,llwith
oil.RemovetheOILFILLcap(blackplastic
plugdirectlyinfrontofthehandle),andadd
oiluntiltheoiljustshowsinthebottomofthe
sightglass.Theapproximateoilcapacityof
thepumpis375milliliters.
3.ReplacetheOILFILLcapandremovethecap
fromoneoftheinletports.TurntheIso-Valve
toOPEN.TurnthemotorswitchON.When
thepumprunssmoothly,turntheIso-Valve
toCLOSEDandreplacethecapontheinlet
port.Thismaytakefromtwoto30seconds,
dependingontheambienttemperature.After
thepumprunsforapproximatelyoneminute,
checkthesightglassforcorrectoillevel—
oilshouldbeevenwiththesightglassOIL
LEVELline.Addmoreoilifnecessary.
Whenthepumpisrunning,theoillevel
shouldbeevenwiththelineonthesight
glass.Underllingwillresultinpoorvacuum
performance.Overllingcanresultinoil
blowingfromtheexhaust.
Yourpumpisnowreadytoevacuateair
conditioningandrefrigerationsystems.Follow
normalserviceproceduresandtheA/C-R
manufacturer’sinstructionsforconnectionstothe
system.
Before using your vacuum pump
Operating Manual
4
Emerson MotorsGeneral Electric Motors
CAUTION! Before connecting the vacuum pump
to an A/C-R system, remove refrigerant from the
system in an accepted manner. Damage to the
pump may occur if evacuation is started while
the system is under high pressure. Robinair
recommends use of our Refrigerant Recovery
and Recycling equipment.
Wiring Instructions:
Thisvacuumpumpfeaturesdualvoltageranges.
Beforeoperatingthepump,readandfollowthese
rewiringinstructions(ifnecessary)tobesureyour
pumpiswiredfortheappropriatevoltage.
CAUTION! Unplug the unit before
beginning any service work. Incorrect
use or connections can cause electrical
shock. Only qualied personnel should
perform service work.
Thisvacuumpumpisfactorywiredforahigh
voltagerangeof220to250volts.Towirethe
switchforalowvoltagerangeof110voltsto115
volts,followthesesteps:
1.
DisconnecttheunitfromtheACpowersource.
2.Loosenthescrewsontheplateattherearof
themotor,andcarefullymovetheplateaside
tocleartheopening.
3.Disconnecttheleadsandreconnectforlow
voltage,followingthediagramandchart.
(Highvoltageconnectionsarealsoshownif
youwanttorewireinthefuture.)
4.Verifyconnectionsaresecureandthere
arenoshortcircuits.Verifythegrounding
connectoriscorrectlyconnected.
5.Re-installtheplateontherearofmotorwith
thescrewswhichwereloosenedinStep2.
IMPORTANT: Checkforshortcircuitsusinga
continuitytesterbeforereconnectingtotheAC
powersource.
— EMERSON —
INTERNAL VOLTAGE CONNECTION
MOTOR LOW HIGH
LEAD VOLTAGE VOLTAGE
BROWN 3 6
WHITE 4 3
BLACK 2 3
INST0350
NOTE: EXTERNAL POWER LEADS ARE ALWAYS
CONNECTED TO TERMINALS 1 AND 4.
Operating Manual
To use the gas
ballast feature
MoisturefromtheA/C-Rsystemthatiscarried
intothepumpasavaportendstocondenseinto
aliquidandcombinewiththevacuumpumpoil.
Whenmoisturecontaminatesthepumpoil,it
reducesthepump’sabilitytoreachitsultimate
deepvacuumlevel.
Thegasballastvalvepurgesasmallamountof
atmosphericairthroughtheexhaustchamber.
Thisextravolumeofairmixeswiththevaporfrom
therefrigerantsystemtopreventcondensation
andtohelpexhaustmoistureintheformofvapor
fromthepump.
Tousethegasballast,startthepumpandopen
thegasballastvalveuntilthesystemhasreached
approximately1000-3000microns.Closethe
valvetoallowthepumptopulldowntoitsultimate
vacuumlevel.(Thegasballastvalveislocated
besidethehandle,oppositetheinlettting.)
Thegasballastvalvemaybeopenedorclosedat
anytimeduringpumpoperation.Itisfullyopenat
twoturnscounterclockwise.
NOTE: Robinair recommends the use of a
thermistor vacuum gauge to most accurately
measure vacuum levels.
5
To maintain the high vacuum
pump
Formaximumperformance,Robinairrecommends
changingvacuumpumpoilaftereachuse.
Vacuum pump oil
Theconditionandtypeofoilusedinanyhighvacuum
pump are extremely important in determining the
ultimateattainablevacuum.Robinairrecommends
the use ofour Premium High Vacuum PumpOil.
Thisoilhasbeenspecicallyblendedtomaintain
maximumviscosityatnormalrunningtemperatures
andtoimprovecoldweatherstarts.
OurPremiumHighVacuumPumpOilisavailable
inquartorgalloncontainers.Orderbypart
number:
13203—Quart(shipped12quartspercase)
13204—Gallon(shipped4gallonspercase)
Oil change procedure
1.Besurethepumpiswarmedup.
2.RemovetheOILDRAINcap.Drain
contaminatedoilintoasuitablecontainerand
disposeofcorrectly.Oilcanbeforcedfrom
thepumpbyopeningtheinletandpartially
blockingtheexhaustwithaclothwhilethe
pumpisrunning.Donotoperatethepumpfor
morethan20secondsusingthismethod.
3.Whentheowofoilhasstopped,tiltthe
pumpforwardtodrainresidualoil.
4.ReplacetheOILDRAINcap.Removethe
OILFILLcap,andllthereservoirwithnew
vacuumpumpoiluntiltheoiljustshowsatthe
bottomofthesightglass.Theapproximateoil
capacityofthepumpis375milliliters.
5.Verifytheinletportsarecapped.TurnON
thepump,andallowittorunforoneminute.
Checktheoillevel.Iftheoilisbelowthesight
glassOILLEVELline,addoilslowly(withthe
pumprunning)untiltheoilreachestheOIL
LEVELline.ReplacetheOILFILLcap,cap
theinlet,andtightenthedraincap.
6.Iftheoilisbadlycontaminated,youmayneed
toushthepump.Toush,removethepump
draincapandstartthepump.Slowlypoura
smallquantityofnewpumpoilthroughtheoil
llinlet.
Repeatthisprocedureasrequireduntilthe
contaminationisremoved.ReplacetheOIL
DRAINcapandrellthereservoirtothe
correctlevelusingfreshpumpoil(Step4).
Cleaning the pump
Useonlysoapandwatertocleanthe
pump.Donotusecommercialcleanersthat
containdegreasingagentsthatcandamage
polycarbonates.Thepumphandleandbaseare
madeofLexan,oneofthetoughestpolycarbonate
plasticsavailable.However,itissensitiveto
degreasingagents.
*Lexan is a registered trademark of General
Electric
Motor lubrication
Afterthreeyearsofnormalserviceoroneyear
ofheavy-dutyservice,addmotoroil.Useelectric
motoroilorSAE10oil.
To shut down the
pump after use
Tohelpprolongpumplifeandpromoteeasystart-
ing,followtheseproceduresforshutdown:
1.Closethemanifoldvalvebetweenthepump
andthesystem.
2.TurntheIso-ValvetotheCLOSEDposition.
3.Removethehosefromthepumpinlet.
4.TurnthepumppowerswitchtoOFF,then
returntheIso-ValvetotheOPENpositionfor
afewsecondstorelieveanyvacuuminside
thepump.
5.Captheinletporttopreventanycontamina-
tionorlooseparticlesfromenteringtheport.
Troubleshooting guide
Thispumphasbeendesignedfordependable
useandlonglife.Ifsomethingshouldgowrong,
however,thefollowingguidewillhelpyougetthe
pumpbackintoserviceasquicklyaspossible.
Ifdisassemblyofthepumpisrequired,please
checkyourwarranty.Thewarrantymaybevoided
bymisuseorcustomertamperingthatresultsin
thepumpbeinginoperable.
Failure to start
Checklinevoltage.Robinairpumpsaredesigned
tostartat+10%linevoltage(loaded)at0
o
C.At
extremes,however,switchingbetweenthestart
andrunwindingsmayoccur.Whenstartingthe
pumpincoldtemperatures,verifytheIso-Valve
andinletportareopentofreeair.
Oilleakage
1.Verifytheoilisnotaresidualaccumulation
fromspillage,etc.
2.Ifleakageexists,themodulecovergasket
ortheshaftsealmayneedreplacing.
Followtheinstructionssuppliedwiththe
sealreplacementkit,partnumber15367.If
leakageexistsintheareaofthedrainplug,
resealtheplugusingacommercialpipe
threadsealer.
Failure to pull a good vacuum
1.VerifytheIso-Valveonthepumpisinthe
OPENposition,andthegasballastknobis
tightlysealed.
2.Verifythevacuumgaugeandallconnections
areingoodconditonandleak-free.Conrm
leakagebymonitoringthevacuumwitha
thermistorgaugewhileapplyingvacuum
pumpoilatconnectionsorsuspectedleak
points.Vacuumwillimprovebrieywhilethe
oilissealingtheleak.
3.Besurethepumpoilisclean.Abadly
contaminatedpumpmayrequireseveraloil
ushes.SeeOILCHANGEPROCEDURE.
4.Verifytheoilisatthecorrectlevel.For
maximumpumpoperation,theoilmustbe
evenwiththeOILLEVELlineonthesight
glasswhenthepumpisrunning.SeeOIL
CHANGEPROCEDURE.Donotoverll.
Operatingtemperaturescausetheoilto
expand,soitwillappearatahigherlevelthan
whenthepumpisnotrunning.Tocheckthe
oillevel,startthepumpwiththeinletcapped.
Checktheoillevelinthesightglass.Addoilif
necessary.
Pump Specications
Model 15401
FrequencyRange.................................... 50-60Hz
FreeAirDisplacement.........................4cfm/60Hz
.................................................. 94l/m@50Hz
................................................ 113l/m@60Hz
Stages..................................................................2
MotorSpeed.............................1425rpm@50Hz
.............................................1725rpm@60Hz
VoltageRange......................................110V–115V
........................................................ 220V–250V
FactoryMicronRating.......................... 15microns
ApproximateOilCapacity............................400ml
Weight........................................................... 13kg
Width....................................................... 14.29cm
Height........................................................ 24.6cm
Length........................................................... 40cm
Intake....................................
1
/4"and
1
/2"SAEMFL
Min.StartingTemp.(at90%voltage)...............0
o
C
MotorSize............0.25kW(
1
/3HP)CapacitorStart
OperatingTemp.............................................. 68
o
C
Models 15601/15603/15605
FrequencyRange.................................... 50-60Hz
FreeAirDisplacement.........................6cfm/60Hz
................................................142l/m@50Hz
................................................170l/m@60Hz
Stages..................................................................2
MotorSpeed.............................1425rpm@50Hz
.............................................1725rpm@60Hz
VoltageRange......................................110V–115V
........................................................ 220V–250V
FactoryMicronRating.......................... 15microns
ApproximateOilCapacity............................400ml
Weight........................................................... 13kg
Width....................................................... 14.29cm
Height........................................................ 24.6cm
Length........................................................... 42cm
Intake.............................
1
/4",
3
/8",and
1
/2"SAEMFL
Min.StartingTemp.(at90%voltage)...............0
o
C
MotorSize...........0.25kW(
1
/3HP)CapacitorStart
OperatingTemp.............................................. 68
o
C
Notes:
1. All motors are internally protected (automatic
reset).
2. Operating temperatures are typical for normal
operating conditions.
3. Model 15603 has a bipolar side grounded plug.
4. Models 15405 & 15605 have Australian plugs.
Because of ongoing product improvements, we reserve the right to
change design, specications, or materials without notice.
Operating Manual
6
Operating Manual
7
INST0026
1
2
3
4
5
6
7
9
8
9
11
12
13
14
16
15
17
Replacement parts
15605/
15601/
Part Item 15401 15603
OilDrainCap(6) 1 40572 40572
OilDrainKit
(includesItemNo.1) 2 13193 13193
ModuleCoverKit
(includesNos.2,4,and5) 3 15337 15337
OilFillCap
(includesNo.7) 4 15371 15371
IntakeFitting
(includesNo.9) 8 15364 555124
IntakeCap(1ea.)
1
/4",
3
/8",
1
/2"SAEMFL 9 555133 555133
VentBolt
(includeso-rings) 11 15338 15338
Handle,PowerCord
andSwitchAssembly 12 15466 15466
Motor 13 15465 15465
Coupling 14 13192 13192
Iso-Valve
TM
Assembly 15 15368 15368
BaseandFootAssembly 16 15369 15369
PumpAssembly,lessmotor
(includesNo.3and6) 17 15547 15548
SealReplacementKit
(notshown) -- 15367 15367
Warranty coverage
Robinairvacuumpumpsarewarrantedagainst
defectsinmaterialandworkmanshipforoneyear
ofnormalusefromthedateofpurchase.Seeyour
distributorforwarrantydetails.
Out of warranty
Apumpwhichisnolongercoveredbytheone-
yearwarrantyperiodandwhichfailstooperate
properlyshouldbereturnedtothedistributor
withafullwrittenexplanationoftheproblem.The
distributormaysuggestreturningthepumptothe
factory.Beforereturninganout-of-warrantypump,
reviewallmaintenanceprocedurestoavoidanun-
necessaryreturn.Replacementpartsareavailable
fordoingyourownservice.
9
116292 Rev. F June 18, 2013 © Bosch Automotive Service Solutions
BOSCH AUTOMOTIVE SERVICE SOLUTIONS
655 EISENHOWER DRIVE
OWATONNA, MN 55060 USA
TECHNICAL SERVICES: 1-800-822-5561
FAX: 1-866-259-1241
CUSTOMER SERVICE: 1-800-533-6127
FAX: 1-800-283-8665
WEB SITE: WWW.ROBINAIR.COM
Call our Toll-Free
Technical Support Line at
800-822-5561
in the continental U.S. and Canada
or visit our website
www.robinair.com
In all other locations, contact your local distributor. To help us serve you better,
be prepared to provide the model number, serial number, and date of purchase of
your unit.
To validate your warranty, complete the warranty card attached to your unit and
return it within ten days from date of purchase.
NATIONWIDE NETWORK OF AUTHORIZED SERVICE CENTERS
If your unit needs repairs or replacement parts, contact the service center in your
area. For help in locating a service center, call the toll-free technical support line,
or visit our website.
Due to ongoing product improvements, we reserve the right
to change design, specications, and materials without notice.
%
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Robinair High Performance Vacuum Pump 15401 User manual

Type
User manual

Robinair High Performance Vacuum Pump 15401 is a high-quality vacuum pump engineered specifically for air conditioning and refrigeration service. It features an offset rotary vane design, which provides powerful, quiet, high vacuum capability and ensures moisture removal. The pump also has a high pumping capacity, which reduces evacuation time.

Some of the key features of the Robinair High Performance Vacuum Pump 15401 include:

  • Iso-ValveTM: Allows the pump to be shut off while still connected to the A/C-R system, which is handy for checking rate of rise.
  • High vacuum rating: The two-stage, offset rotary vane design provides powerful, quiet, high vacuum capability and ensures moisture removal.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI