Cisco Network Convergence System 540 Series Routers Installation guide

Type
Installation guide
Cisco Network Convergence System 540 Small Density Routers
Hardware Installation Guide
First Published: 2021-02-17
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS,
INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND,
EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH
THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY,
CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB's public domain version of
the UNIX operating system. All rights reserved. Copyright ©1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS" WITH ALL FAULTS.
CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT
LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network
topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional
and coincidental.
All printed copies and duplicate soft copies of this document are considered uncontrolled. See the current online version for the latest version.
Cisco has more than 200 offices worldwide. Addresses and phone numbers are listed on the Cisco website at www.cisco.com/go/offices.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL:
https://www.cisco.com/c/en/us/about/legal/trademarks.html. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a
partnership relationship between Cisco and any other company. (1721R)
©2018–2020 Cisco Systems, Inc. All rights reserved.
CONTENTS
Safety Warnings 1
CHAPTER 1
Standard Warning Statements 1
Safety Guidelines for Personal Safety and Equipment Protection 2
Safety Precautions for Module Installation and Removal 2
Safety with Electricity 3
Power Supply Considerations 5
Power Connection Guidelines 5
Guidelines for DC-Powered Systems 5
Guidelines for AC-Powered Systems 6
Prevent Power Loss 6
Preventing ESD Damage 6
Cisco NCS 540 Small Density Routers Overview 9
CHAPTER 2
Network Interfaces 9
Cisco NCS 540 Small Density Router Features 11
Specification 12
Interface Naming 12
External Alarm Inputs 13
Console 13
USB Console 14
Online Insertion and Removal 14
Supported Transceiver Modules 14
Prepare for Installation 15
CHAPTER 3
General Precautions 15
Site Planning Checklist 16
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
iii
Environmental Requirements 16
Airflow Guidelines 16
Site Power Guidelines 20
Site Cabling Guidelines 21
Tools and Equipment 21
Prepare Your Location 22
Prepare Yourself 23
Prepare Rack for Router Installation 24
Cabinet Selection Guidelines 25
Unpack the Cisco NCS 540 Small Density Router 26
Install the Device 29
CHAPTER 4
Rack Compatibility 29
Rack Types 29
Set up Device on Rack or Wall 31
Rack Mount 31
Wall Mount 36
Ground the Device 36
Install the AC Power Cables 37
Activate an AC Power Supply Module 38
Install the DC Power Cables 39
Activate a DC Power Supply Module 41
Port Connection Guidelines 42
Connect to the Console Port 43
Connect to the Management Ethernet Port 45
Connecting Timing Cables 46
Connecting Cables to a GPS Interface 46
Install and Remove Transceiver Modules 47
Install and Remove SFP Modules 47
Connect Interface Ports 52
Maintain Transceivers and Optical Cables 52
Appendix 53
CHAPTER 5
LEDs 53
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
iv
Contents
Router LEDs 53
Fan Assembly LEDs 55
Power Status LEDs 55
Combination of LEDs 55
SFP SFP+ Port LED 56
Management Port LEDs 56
System Specifications 56
Weight and Power Consumption 56
Environmental Specifications 56
RJ-45 Connectors 57
Transceiver and Cable Specifications 57
RJ-45 ToD or 1-PPS Port Pinouts 57
Console Port Pinouts 58
Alarm Port Pinouts 58
USB Port Console Pinouts 59
USB Port Memory Pinouts 59
Management Ethernet Port Pinouts 60
GPS Port Pinouts 60
AC Power Cord Specifications 60
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
v
Contents
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
vi
Contents
CHAPTER 1
Safety Warnings
This handout lists the safety warnings necessary for handling this chassis. Before you install or service the
chassis, review these safety warnings to avoid injuring yourself or damaging the equipment.
For a complete list of translated safety warnings, see the Regulatory Compliance and Safety Information —
Cisco NCS 500 Series Routers document.
The safety warnings are grouped under the following sections:
Standard Warning Statements, on page 1
Safety Guidelines for Personal Safety and Equipment Protection, on page 2
Safety Precautions for Module Installation and Removal, on page 2
Safety with Electricity, on page 3
Power Supply Considerations, on page 5
Preventing ESD Damage, on page 6
Standard Warning Statements
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work
on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard
practices for preventing accidents. Use the statement number provided at the end of each warning to locate
its translation in the translated safety warnings that accompanied this device. Statement 1071
SAVE THESE INSTRUCTIONS
Warning
This unit is intended for installation in restricted access areas. A restricted access area can be accessed only
by using a special tool, lock and key, or other means of security. Statement 1017
Warning
Ultimate disposal of this product must be handled according to all national laws and regulations. Statement
1040
Warning
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
1
To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended
ambient temperature of: –40 to 149°F (–40 to 65°C). Statement 1047
Warning
Mount the device on a rack that is permanently affixed to the building. Statement 1049
Warning
This device is a Class A Device and is registered for EMC requirements for industrial use. You must be aware.
If sold or purchased by mistake, do replace with a residential-use type. Statement 294
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement
1030
Warning
SafetyGuidelines forPersonalSafety andEquipmentProtection
The following guidelines ensure your safety and protect the equipment. This list does not include all the
potentially hazardous situations. Therefore, you must be alert.
Before moving the system, always disconnect all power cords and interface cables.
Never assume that power is disconnected from a circuit; always check.
Before and after installation, keep the chassis area clean and dust free.
Keep tools and assembly components away from walk areas where you or others can trip over them.
Do not work alone if potentially hazardous conditions exist.
Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.
Do not wear loose clothing that may get caught in the chassis.
When working under conditions that may be hazardous to your eyes, wear safety glasses.
Safety Precautions for Module Installation and Removal
Be sure to observe the following safety precautions when you work on the chassis.
Class 1 laser product. Statement 1008
Warning
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
2
Safety Warnings
Safety Guidelines for Personal Safety and Equipment Protection
Do not stare into the beam or view it directly with optical instruments. Statement 1011
Warning
Invisible laser radiations present. Statement 1016
Warning
Safety with Electricity
Before working on a chassis or with power supplies, unplug the power cord on AC units. Disconnect the
power at the circuit breaker on DC units. Statement 12
Warning
Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces,
and watches). Metal objects heat up when connected to power and ground and can cause serious burns or
weld the metal object to the terminals. Statement 43
Warning
Avoid using or servicing any equipment that has outdoor connections during an electrical storm. There may
be a risk of electric shock from lightning. Statement 1088
Warning
Read the installation instructions before connecting the system to the power source. Statement 1004
Warning
When you connect or disconnect the power and relay connector with power applied, an electrical arc can
occur. This action can cause an explosion in hazardous area installations. Be sure that power is removed from
the switch and alarm circuit. Be sure that power cannot be accidentally turned on or verify that the area is
nonhazardous before proceeding. Failure to securely tighten the power and relay connector captive screws
can result in an electrical arc if the connector is accidentally removed. Statement 1058
Warning
The plug-socket combination must be accessible always, because it serves as the main disconnecting device.
Statement 1019
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence
of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician
if you are uncertain that suitable grounding is available. Statement 1024
Warning
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
3
Safety Warnings
Safety with Electricity
This unit may have more than one power supply connection. All connections must be removed to de-energize
the unit. Statement 1028
Warning
This product requires short-circuit (overturned) protection, to be provided as part of the building installation.
Install only in accordance with national and local wiring regulations. Statement 1045
Warning
When installing or replacing the unit, ensure the ground connection first and disconnected last. Statement
1046
Warning
When you connect or disconnect the power and/or alarm connector with power applied, an electrical arc can
occur. This could cause an explosion in hazardous area installations. Be sure that all power is removed from
the switch and any other circuits. Be sure that power cannot be accidentally turned on or verify that the area
is nonhazardous before proceeding. Statement 1058
Warning
This equipment is intended to be grounded to comply with emission and immunity requirements. Ensure that
the switch functional ground lug is connected to earth ground during normal use. Statement 1064
Warning
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Warning
When working on equipment that is powered by electricity, follow these guidelines:
Locate the room’s emergency power-off switch. If an electrical accident occurs, you know where to
quickly turn off the power.
Before starting work on the system, turn off the DC main circuit breaker and disconnect the power
terminal block cable.
Disconnect all power when:
Working on or near power supplies
Installing or removing a device chassis or network processor module
Performing most hardware upgrades
Never install equipment that appears damaged.
Carefully examine your work area for possible hazards, such as moist floors, ungrounded power extension
cables, and missing safety grounds.
Never assume that power is disconnected from a circuit; always check.
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
4
Safety Warnings
Safety with Electricity
Never perform any action that creates a potential hazard to people or makes the equipment unsafe.
If an electrical accident occurs and you are uninjured:
Use caution to avoid injuring yourself.
Turn off power to the device.
Seek medical attention, if necessary.
Use the following guidelines when working with any equipment that is disconnected from a power source,
but connected to telephone wiring or network cabling:
When installing or modifying telephone lines, use caution.
Never install telephone jacks in wet locations unless the jack is designed to handle such locations.
Never install telephone wiring during a lightning storm.
Power Supply Considerations
Check the power at your site to ensure that you are receiving clean power (free of spikes and noise). If
necessary, install a power conditioner.
Power Connection Guidelines
This section provides guidelines for connecting the device power supplies to the site power source.
Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground
conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that
suitable grounding is available. Statement 1024
Warning
The plug-socket combination must be accessible always because it serves as the main disconnecting device.
Statement 1019
Warning
This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation.
Install only in accordance with national and local wiring regulations. Statement 1045
Warning
Guidelines for DC-Powered Systems
Basic guidelines for DC-powered systems include the following:
Each chassis power supply has its own dedicated input power source. The source must comply with the
safety extra-low voltage (SELV) requirements in the UL 60950, CSA 60950, EN 60950, and IEC 60950
standards.
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
5
Safety Warnings
Power Supply Considerations
Protect the circuit by a dedicated two-pole circuit breaker. Ensure that the circuit breaker is sized according
to the power supply input rating and local or national code requirements.
The circuit breaker is considered as the disconnect device and is easily accessible.
The system ground is the power supply and chassis ground.
Use the grounding lug to attach a wrist strap for ESD protection during servicing.
Do not connect the DC return wire to the system frame or to the system-grounding equipment.
Ensure that the DC return is grounded at the source side.
Guidelines for AC-Powered Systems
Basic guidelines for AC-powered systems include the following:
Each chassis power supply has its own dedicated branch circuit.
Ensure that the circuit breaker is sized according to the power supply input rating and local or national
code requirements.
The AC power receptacles that are used to plug in the chassis must be the grounding type. The grounding
conductors that connect to the receptacles must connect to protective earth ground at the service equipment.
Prevent Power Loss
Use the following guidelines to prevent power loss to the device:
To prevent input power loss, ensure that the maximum load on each circuit supplying the power is within
the current ratings of the wiring and breakers.
In some systems, you can use an UPS to protect against power failures at your site. Avoid UPS types
that use ferroresonant technology. These UPS types can become unstable with systems such as the device,
which can have substantial current-draw fluctuations due to bursty data traffic patterns.
Determining power requirements is useful for planning the power distribution system to support the device.
Preventing ESD Damage
Ground this equipment. Use a green and yellow 6-AWG ground wire to connect the host to earth ground
during normal use. Statement 383
Warning
Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. ESD may occur when
electronic printed circuit cards are improperly handled and can cause complete or intermittent failures. When
removing and replacing modules, always follow these ESD prevention procedures:
Ensure that the device chassis is electrically connected to earth ground.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. To channel unwanted
ESD voltages safely to ground, connect the clip to an unpainted surface of the chassis frame. To guard
against ESD damage and shocks, the wrist strap and cord must operate effectively.
If no wrist strap is available, ground yourself by touching a metal part of the chassis.
When installing a component, use any available ejector levers or captive installation screws to properly
seat the bus connectors in the backplane or midplane. These devices prevent accidental removal, provide
proper grounding for the system, and help to ensure that bus connectors are properly seated.
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
6
Safety Warnings
Guidelines for AC-Powered Systems
When removing a component, use available ejector levers or captive installation screws, if any, to release
the bus connectors from the backplane or midplane.
Handle components by only their handles or edges; do not touch the printed circuit boards or connectors.
Place a removed component board side up on an antistatic surface or in a static-shielding container. If
you plan to return the component to the factory, immediately place it in a static-shielding container.
Avoid contact between the printed circuit boards and clothing. The wrist strap only protects components
from ESD voltages on the body; ESD voltages on clothing can still cause damage.
Never attempt to remove the printed circuit board from the metal carrier.
For the safety of your equipment, periodically check the resistance value of the antistatic wrist strap. Maintain
the value between 1 and 10 Mohm.
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
7
Safety Warnings
Preventing ESD Damage
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
8
Safety Warnings
Preventing ESD Damage
CHAPTER 2
Cisco NCS 540 Small Density Routers Overview
The Cisco NCS 540 Small Density Router is temperature-hardened, fixed port, one rack unit form-factor
router. An IOS XR based cell site router, the router extends Cisco’s 5G Converged SDN Transport to edge
of the networks as a CSR/NID/CPE, with the smallest footprint, ever.
The Cisco N540X-6Z18G-SYS-A, N540X-6Z18G-SYS-D, N540X-8Z16G-SYS-A, and N540X-8Z16G-SYS-D
routers have parity with Cisco IOS XR Release 7.2.1 with the rest of the NCS 540 variants.
The Cisco N540X-6Z18G-SYS-A/D and Cisco N540X-8Z16G-SYS-A/D routers include the following
conformal coating:
The PSU is conformal coated.
The PSU is fixed and non-removable. The dual power supply (AC and DC) are installed inside the router.
The mother board has no conformal coating.
For more information about its features and benefits, see the Cisco Network Convergence System 540 Small
Density Router Data Sheet.
Network Interfaces, on page 9
Cisco NCS 540 Small Density Router Features, on page 11
Specification, on page 12
Interface Naming, on page 12
External Alarm Inputs, on page 13
Console, on page 13
Online Insertion and Removal, on page 14
Supported Transceiver Modules, on page 14
Network Interfaces
The Cisco N540X-6Z18G-SYS-A/D router has the following hardware features:
18 X 1G SFP+ ports
6 X 1G/10G SFP+ ports
The Cisco N540X-8Z16G-SYS-A/D router has the following hardware features:
8 CSFP ports
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
9
4 SFP ports
4 Copper ports
8 X 1/10GSFP+ ports
Figure 1: Cisco N540X-6Z18G-SYS-A
Figure 2: Cisco N540X-6Z18G-SYS-D
Figure 3: Cisco N540X-8Z16G-SYS - A
Figure 4: Cisco N540X-8Z16G-SYS - D
All ports are color coded in the chassis for ease of access; for example, the 10G SFP+ ports are in pink, the
1G SFP ports are in blue.
Note
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
10
Cisco NCS 540 Small Density Routers Overview
Network Interfaces
Cisco NCS 540 Small Density Router Features
Figure 5: Cisco N540X-6Z18G-SYS-A/D Ports
10 MHz Input or Output2AC Power Input1
USB 2.0 MEM port4USB Console3
Alarm Port6Management Port5
LED Port8Console Port7
1 PPS Input or Output
Port
10Time of Day (TOD) Port9
Figure 6: N540X-8Z16G-SYS-A/D Ports
10 MHz Input or Output
1 PPS Input or Output
Port
2AC Power Input1
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
11
Cisco NCS 540 Small Density Routers Overview
Cisco NCS 540 Small Density Router Features
Management Port
Alarm Port
4USB Console
USB 2.0 MEM port
3
4 - 1G SFP ports (ports 4
to 7)
64 - Cu ports (ports 0 to 3)5
8 - 1/10G SFP+ ports
(ports 24 to 31)
88 - 1G SFP ports (ports 8
to 23)
For these cages, each cage
opening has two port
names, hence total
number of ports 8X2 =16
( port 8 to 23).
You can also use CSFPfor
these cages.
7
Specification
For information on physical specification, temperature, and other details for all variants, see Cisco NCS 540
chassis specification in the Cisco Network Convergence System 540 Small Density Router Data Sheet.
Interface Naming
The following table shows the interface naming of the Cisco N540X-6Z18G-SYS-A/D router:
Table 1: Port Numbering
1G/10G Dual rate ports
(SFP+)
1G ports
(SFP)
0/23to0/180/17to0/0
The interface-path-id is rack /slot /module /port. The slashes between values are required as part of the
notation.
GigE — 0/0/0/0 - 0/0/0/17
TenGigE — 0/0/0/18 - 0/0/0/23
Dual-Rate functionality is supported only with the supported SFP.
Note
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
12
Cisco NCS 540 Small Density Routers Overview
Specification
Table 2: Maximum Number of Ports
Port
Number
Maximum Number of
Ports
Category
0/0 - 23241GE
0/18 - 23610GE
The following table shows the interface naming of the N540X-8Z16G-SYS-A/D router:
Table 3: Port Numbering
1G/10G Dual rate SFP+
ports
1G SFP ports (Including
CSFP)
1G SFP ports1G Copper ports
0/24-0/310/8 to 0/23*0/4 to 0/70/0 to 0/3
* ports 8, 11, 12, 15, 16, 19, 20, and 23 are enabled only with CSFP optical modules.
The interface-path-id is rack/slot/module/port. The slash between values is required as part of the notation.
GigE — 0/0/0/0 to 0/0/0/23 (ports 8, 11, 12, 15, 16, 19, 20, and 23 are enabled only with CSFP optics)
TenGigE — 0/0/0/24- 0/0/0/31
Table 4: Maximum Number of Ports
Port
Number
Maximum Number of
Ports
Category
0/0 – 0/341GE
copper
0/4-0/2320 (including CSFP ports)1GE SFP
0/24-0/31810GE
External Alarm Inputs
The router supports four dry contact alarm inputs through an RJ-45 jack at the front panel.
Normally Open—indicates that no current flows through the alarm circuit and the alarm is generated
when the current is flowing.
Each alarm input can be provisioned as critical, major, or minor.
Console
The RS232 console port provides transmission (Tx), reception (Rx), and ground (Gnd).
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
13
Cisco NCS 540 Small Density Routers Overview
External Alarm Inputs
USB Console
A single USB 2.0 Type-A receptacle on the front panel of the router provides console access to ROMMON,
Cisco IOS-XR and diagnostics. While it uses the Type-A connector, it operates as a USB peripheral only for
connection to an external host computer. This interface requires the use of a Type-A to Type-A connector
instead of a standard USB cable.
Use of the USB console is mutually exclusive of the RS232 console port. This interface requires the use of a
Type-A to Type-A USB cable. If you insert the USB cable and connect to the host computer, then you can
only enter the commands using the USB.
Note
Online Insertion and Removal
The router supports the following Online Insertion and Removal (OIR) operations:
When an SFP is removed, there is no effect on traffic flowing on other ports.
When an SFP is installed, the system initializes that port for operation based on the current configuration.
If the inserted SFP is incompatible with the current configuration of that port, the port does not become
operational until the configuration is updated.
When both power supplies are installed and active, the load may be shared between them or a single
PSU supports the whole load. When a power supply is not working or the input cable is removed, the
remaining power supply takes the entire load without disruption.
Both the power supply modules are fixed and cannot be removed.
Supported Transceiver Modules
For more information on the supported transceiver modules, see Transceiver Module Group (TMG)
Compatibility Matrix. In the Begin your Search search box, enter the keyword and click Enter.
Cisco Network Convergence System 540 Small Density Routers Hardware Installation Guide
14
Cisco NCS 540 Small Density Routers Overview
USB Console
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66