Inhalt
6.6 Alarm buffering.................................................................................................... 33
6.7 Event delay.......................................................................................................... 33
6.8 Virtual inputs and outputs.................................................................................... 33
6.9 Changing ÜE assignment by command (from V3.2) ........................................... 34
6.10 Switching detector algorithms by command (from V3.2)..................................... 34
6.11 Time synchronisation .......................................................................................... 35
6.12 Variable SIGMALOOP cycle time........................................................................ 35
6.13 BMT/IMT mixed mode ......................................................................................... 35
6.14 Alarm counters .................................................................................................... 35
7 Control unit connections.................................................................................. 37
7.1 Local alarm (LA).................................................................................................. 38
7.2 Alarm transceiver (AT) ........................................................................................ 38
7.3 Key depot (KD).................................................................................................... 38
7.4 Fire brigade operating panel (FBF) ..................................................................... 38
8 Transponders and loop elements.................................................................... 41
8.1 General................................................................................................................ 42
8.2 Loop elements..................................................................................................... 42
8.2.1 Maxitransponder SPF 3500, 4STE control module ............................................. 42
8.2.2 Input/output module FDCIO222 (FDCI222)......................................................... 44
8.2.3 Fdnet Transponder FDCIO223 (from mid-2006) ................................................. 45
8.2.4 Contact coupler SPF 5300 .................................................................................. 47
8.2.5 SIGMASPACE gateway ...................................................................................... 48
8.2.6 Zone operating panel SPF 3300 ......................................................................... 48
8.3 Outputs................................................................................................................ 49
8.3.1 Indicator panel control facility SPF 3200............................................................. 49
8.3.2 Control module SPF 5100................................................................................... 49
8.3.3 Multiple control facility SPF 5200 ........................................................................ 50
8.3.4 External alarm display module SPF 3110 ........................................................... 50
8.3.5 SIGMALOOP Splitter (V2.6)................................................................................ 50
8.4 Technical data, voltage, current, dimensions...................................................... 52
8.5 Cycle time for signals from transponders and contact couplers.......................... 53
9 Special control facilities ................................................................................... 55
9.1 Extinguishing control module .............................................................................. 56
9.1.1 Gas extinguishing systems.................................................................................. 57
9.1.2 Preaction sprinkler extinguishing control module................................................ 57
9.1.3 SIGMALOOP extinguishing interface.................................................................. 58
9.1.4 FDnet extinguishing interface.............................................................................. 59
9.2 Close-and-retain systems (FSA) ......................................................................... 59
9.2.1 List of approved power supply units.................................................................... 60
10 Programming of control facilities .................................................................... 61
10.1 Description of control pattern .............................................................................. 62
10.1.1 AL/LA – Alerting facilities..................................................................................... 62
10.1.2 EV – Evacuation alarm (internal alarm)............................................................... 63
10.1.3 Control facility (ST).............................................................................................. 63
10.1.4 Monitored control lines according to VdS via transponder SPF 3500 ................. 63
10.1.5 Display (ANZ)...................................................................................................... 64
10.1.6 Close-and-retain system (FSA) control facility and fire section control facility.... 64
10.1.7 Detector display and event display control pattern.............................................. 64
10.2 Freely configurable control parameters from V3.2 .............................................. 65
10.3 Overviev of control criteria................................................................................... 66
10.3.1 Control Pattern AL (alerting facility), EV (evacuation alarm, ANZ (display) ........ 67
10.3.2 Control Pattern ST (control facility) ..................................................................... 68
BMT Project Planning Guidelines
Best.Nr. A24205-A337-B970 – Edition 12 (03/07)