MULTISPAN LC-1046D Owner's manual

Type
Owner's manual
LC-1046D
AUXILIARY SUPPLY:
LENGTH COUNTER
Supply voltage
Power consumption
(VA RATING) Approx 4 VA @ 230V AC MAX
ENVIRONMENT CONDITION:
Relative Humidity
Protection Level
(AS Per Request)
Operating Temp. 0°C to 55°C
UP to 95% RH
(non-condensing)
IP-65 (Front side) As per IS/IEC
60529 : 2001
230V AC, 50Hz
Input (Start Pulse)
Display
Memory
Size
Keys
Counting Direction
Panel Cutout
Upper: 6 digit, 7 segment, 0.56” Red
Nonvolatile
Lower: 4 digit, 7 segment, 0.40” Green
96 (H) x 96 (W) x 43 (D) mm
SET/ENT, SHIFT, INC, RESET
92 (H) x 92 (W) mm
TECHNICAL SPECIFICATION
GENERAL SPECIFICATION:
DISPLAY AND KEYS:
DIMENSION:
MECHANICAL INSTALLATION
TERMINAL CONNECTION
NPN/PNP Proximity
Micro Switch
UP/ DOWN
Reset Option Front Panel Reset
Terminal Reset
96
92
92
96
Outline Dimension (mm) Panel Cutout
Dimension (mm)
INPUT SPECIFICATION:
OUTPUT SPECIFICATION:
Relay
Relay Type
Rating
1 nos.
1 C/O (NO-C-NC)
5A, 230V AC
Relay Output
43
3
PROXY COLOR CODE
+12V OUTPUT GND
Brown Black Blue
Red Green Black
LC 1046D
TOTAL
BATCH
1 2 3 4 78910
56
L N
www.multispanindia.com
MICRO SWITCH:- M/S Connection 7 & 9
230V AC
50Hz, 4VA
!
Made in India
RST
NCCNO
RELAY
+12V
I/P I/P
NPN PNP GND
LC 1046D-B1-00
MECHANICAL INSTALLATION GUIDELINES
1. Prepare the panel cutout with proper dimensions as shown
above.
2. Fit the unit into the panel with the help of clamp given.
3. The equipment in its installed state must not come in close
proximity to any heating source, caustic vapors, oils steam,
or other unwanted process byproducts.
4. Use the specified size of crimp terminal (M3.5 screws) to
wire the terminal block. Tightening the screws on the
terminal block using the tightening torque of the range of
1.2 N.m.
5. Do not connect anything to unused terminals.
INSTALLATION GUIDELINES
1. This equipment, being built-in-type, normally becomes a
part of main control panel and in such case the terminals
do not remain accessible to the end user after installation
and internal wiring.
2. Do not allow pieces of metal, wire clippings, or fine metallic
fillings from installation to enter the product or else it may
lead to a safety hazard that may in turn endanger life or
cause electrical shock to the operator.
3. Circuit breaker or mains switch must be installed between
power source and supply terminal to facilitate power ‘ON’ or
‘OFF’ function. However this mains switch or circuit breaker
must be installed at convenient place normally accessible to
the operator.
4. Use and store the instrument within the specified ambient
temperature and humidity ranges as mentioned in this
manual.
MAINTENANCE
1. The equipment should be cleaned regularly to avoid
blockage of ventilating parts.
2. Clean the equipment with a clean soft cloth. Do not use
isopropyl alcohol or any other cleaning agent.
3. Fusible resistor must not be replaced by operator.
Read complete instructions prior to installation
and operation of the unit.
WARNING : Risk of electric shock.
SAFETY PRECAUTION
!
All safety related codifications, symbols and instructions
that appear in this operating manual or on the equipment
must be strictly followed to ensure the safety of the operating
personnel as well as the instrument.
If all the equipment is not handled in a manner specified
by the manufacturer, it might impair the protection provided
by the equipment.
WARNING GUIDELINES
WARNING : Risk of electric shock.
1. To prevent the risk of electric shock, power supply to the
equipment must be kept OFF while doing the wiring
arrangement. Do not touch the terminals while power is
being supplied.
2. To reduce electro magnetic interference, use wire with
adequate rating and twists of the same of equal size shall
be made with shortest connection.
3. Cable used for connection to power source, must have a
cross section of 1mm or greater. These wires should have
insulations capacity made of at least 1.5kV.
4. A better anti-noise effect can be expected by using
standard power supply cable for the instrument.
1 - Total Length in meter
2 - Length Counting Speed (Meter/Min)
FRONT PANEL DESCRIPTION
To enter in parameter setting
mode
To reset total Length
To view batch count
PRESS KEYFUNCTION
OPERATOR MODE
PARAMETER SETTING MODE
Edited parameter value to be set,
And move to the next parameter
It will select the digit to modify,
When value is edited
It will change the Value of
selected digit
Press Key
RESET
01 2 3 4.5
01 2 3
1
2
To view grand total
KEY OPERATION
PARAMETER SETTING
1 2 3 4 5. 6
9 9 9 9 9. 9
9 9 9 9. 9 9
D O W N
e n a b L e
9 9 . 9
9 9 9 9 9 9
m e d I u m
9 9 9 9
S E C O N D
1 2 3. 4
s e t
d I a
C O N T
p a s s
t I m e
D P
p u L S
P P R
P A S S
Change by
& Key
Change by
& Key
Change by
& Key
Change by
Key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
Press key
SET
ENT
SET
ENT
SET
ENT
SET
ENT
SET
ENT
SET
ENT
SET
ENT
SET
ENT
Total Length in Mtr.
Speed in Mtr/Min
Set Length Value
Set Diameter Value
Set Count Direction
Enable Mode : Password
will show on display
Disable Mode : Password
will not show on display
direct show set point
(UP & Down)
Set Time Value
Set Decimal Point
Set Speed Selection
Set PPR Selection
First : First it will show
password then it will
show the set point
Second : First it will show
set point it will show the
password
Press key for save & exit
SET
ENT
NOTE
1). The proximity switch give pulse to counter everytime the
metal on the roller is sensed.
2). Length of Material ( in meter ) for one revolution
= 3.14 X Diameter (mm)
3). Total length
= { 3.14 X Diameter (mm) X Number of Revolutions } / 1000
4). Total Meters/Minute
= { 3.14 X Diameter (mm) X RPM } / 1000 X PPR
WORKING
1). When proxy pulse comes, upper display indicates increment
in ‘Total Length’ in Meter, Lower Display indicates‘Speed’
in Meter/Min according to Diameter and PPR set.
2). For Manual Reset Mode, Set time = 00.0 sec &
For Auto Reset Mode, Set time = 00.1 to 99.9 sec.
3). When Total Length = Set Length, Then Relay will energies ,
and remains ON till Set Auto Reset Time. Relay will turn off
after completion of time.
If time is set = 00.0 sec. then relay remains ON until key
is pressed.
4). If there is a power failure, the last reading is stored in the
memory and Counter starts resume counting from the last
stored value, when power ON.
5). No. of bolts inserted in a roller should be the same as that
of PPR.
Dia mm
20mm Minimum
4mm Distance
Proximity
Note:
PROXY ALIGEMENT
1). Please consult support engineers for sensing area size for
proxy to sense.
2). Please ensure proper sensing area size before installing
proxy sensor in your equipment.
3). Sensing area must be equal or more than the proxy
head size.
NOTE
Slow ( Max. RPM 500)
Medium ( Max. RPM 5000)
Fast ( Max. RPM 15000)
Change by
Key
Change by
Key
Change by
Key
Change by
Key
Change by
Key
Range :- 000.001
to 99999 mtr
Range :- 00.0
to 99.9 sec
Range :- 0000.01
to 9999.99 mm
Range :-
999.999,
9999.99, 99999.9
& 999999
Pulse per revolution
2 5
p a s s
Change by
& Key
Press key
SET
ENT
Password 25 Fix
  • Page 1 1
  • Page 2 2
  • Page 3 3

MULTISPAN LC-1046D Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI